Skip to contentSkip to conversation

Time for cell code reshuffle?

DISCUSSION Arnd Bergmann 9 participants 14 messages Dec 21, 2007 – Dec 26, 2007

lore
Share & tools
lore
#0 lore raw

We've been discussing in the past a few times where we should best put the spufs code, and when to do it. Since Jeremy and I now have all the current patches in powerpc.git, maybe we should do it now.

To the question, where what it should go, I'd leave the decision to Jeremy, but my current idea would be:

arch/powerpc/platforms/cell/spufs -> arch/powerpc/spufs arch/powerpc/platforms/cell/spu_{callbacks,base,syscalls,fault,notify}.[co]
-> arch/powerpc/spufs/{callbacks,base,syscalls,fault,notify}.[co]

If we do it in git now, that should result in a minimal breakage of patches.

A related question is what to do about the location of the other cell related files. platforms/ps3 is already pretty self-contained once we have spufs outside of platforms/cell, but there is still some code shared between platforms/cell and platforms/celleb, and each of these directories also contains code that is only relevant for a subset of the platforms.

My position on these files is that while I find the current state a little bit confusing, I don't have an idea how to do it better either, and I think we should just leave the platform files where they are.

	Arnd <><
#1 lore raw
Quoted 10 lines · Arnd Bergmann

We've been discussing in the past a few times where we should best put the spufs code, and when to do it. Since Jeremy and I now have all the current patches in powerpc.git, maybe we should do it now.

To the question, where what it should go, I'd leave the decision to Jeremy, but my current idea would be:

arch/powerpc/platforms/cell/spufs -> arch/powerpc/spufs arch/powerpc/platforms/cell/spu_{callbacks,base,syscalls,fault,notify}.[co]
-> arch/powerpc/spufs/{callbacks,base,syscalls,fault,notify}.[co]

I think we should consider support for SpursEngine. At the moment I have no idea of what it needs, and if no one else does we need to find out.

Quoted 7 lines

If we do it in git now, that should result in a minimal breakage of patches.

A related question is what to do about the location of the other cell related files. platforms/ps3 is already pretty self-contained once we have spufs outside of platforms/cell, but there is still some code shared between platforms/cell and platforms/celleb, and each of these directories also contains code that is only relevant for a subset of the platforms.

It seems platforms/cell should have the shared and/or generic code, and the other stuff moved into a new platform directory, but is it worth the effort?

-Geoff

#2 lore raw
Quoted 9 lines · Geoff Levand
Quoted 3 lines · Arnd Bergmann

arch/powerpc/platforms/cell/spufs -> arch/powerpc/spufs arch/powerpc/platforms/cell/spu_{callbacks,base,syscalls,fault,notify}.[co]
-> arch/powerpc/spufs/{callbacks,base,syscalls,fault,notify}.[co]

I think we should consider support for SpursEngine. At the moment I have no idea of what it needs, and if no one else does we need to find out.

Hmm, since there is not much documentation available for SpursEngine, it's rather hard to tell what needs to be done for it.

If we think that it will hit the kernel anytime soon, we could use fs/spufs instead of arch/powerpc/spufs right away. Interestingly, this is where it was initially, but got moved to arch/powerpc/platforms/cell/spufs after a lot of discussion ;-).

Quoted 2 lines

It seems platforms/cell should have the shared and/or generic code, and the other stuff moved into a new platform directory, but is it worth the effort?

There is very little code in platforms/cell that can not be generic, so I think it's not worth splitting it. The only IBM blade specific files are cbe_cpufreq_pmi.c and parts of setup.c and pervasive.c. Everything else could be shared by about any generic implementation without a hypervisor.

	Arnd <><
#3 lore raw
Quoted 11 lines · Arnd Bergmann
Quoted 1 line

It seems platforms/cell should have the shared and/or generic code,

and the other

Quoted 1 line

stuff moved into a new platform directory, but is it worth the

effort?

There is very little code in platforms/cell that can not be generic, so I think
it's not worth splitting it. The only IBM blade specific files are cbe_cpufreq_pmi.c and parts of setup.c and pervasive.c. Everything else could
be shared by about any generic implementation without a hypervisor.

Another option is to have:

platforms/celleb -> platforms/beat

and withing platforms/cell, rename blade specific files to something (can't find what, works on CAB too) and add celleb "bare metal" files.

A platform directly doesn't have to deal with one platform. For example, platforms/44x contains a lot of board support.

Now, one question is how far can we merge celleb support with the common blade/CAB code...

Cheers,
Ben.

#4 lore raw
Quoted 21 lines · Benjamin Herrenschmidt
Quoted 11 lines · Arnd Bergmann
Quoted 1 line

It seems platforms/cell should have the shared and/or generic code,

and the other

Quoted 1 line

stuff moved into a new platform directory, but is it worth the

effort?

There is very little code in platforms/cell that can not be generic, so I think
it's not worth splitting it. The only IBM blade specific files are cbe_cpufreq_pmi.c and parts of setup.c and pervasive.c. Everything else could
be shared by about any generic implementation without a hypervisor.

Another option is to have:

platforms/celleb -> platforms/beat

and withing platforms/cell, rename blade specific files to something (can't find what, works on CAB too) and add celleb "bare metal" files.

Quoted 5 lines

A platform directly doesn't have to deal with one platform. For example, platforms/44x contains a lot of board support.

Now, one question is how far can we merge celleb support with the common blade/CAB code...

Celleb-native needs own machine definition and setup code due to HW and FW deferences between CellBlade and Celleb. Of course, because Celleb-native and Celleb-Beat use some codes commonly, we need a place to put Celleb common codes.

But I don't know your idea is better or not.

Best regards,
Kou Ishizaki

#5 lore raw
Quoted 6 lines · Ishizaki Kou

Celleb-native needs own machine definition and setup code due to HW and FW deferences between CellBlade and Celleb. Of course, because Celleb-native and Celleb-Beat use some codes commonly, we need a place to put Celleb common codes.

But I don't know your idea is better or not.

The two more sensible options I can see are

* leave everything where it is, live with the problem that the separation between celleb-native, celleb-beat and ibm-native is unclear.
* put both celleb and the ibm blades into the cell subdirectory, now with three different machine descriptions in there and only make sure that platforms/cell doesn't share any code with ps3, which is more clearly separated already (once we move spufs out).

I'm fine either way, and will accept patches from Toshiba to merge the two directories if you prefer that, but I won't do it myself.

	Arnd <><
#6 lore raw
In reply to Geoff Levand
Quoted 5 lines · Geoff Levand

It seems platforms/cell should have the shared and/or generic code, and the other
stuff moved into a new platform directory, but is it worth the effort?

No, platforms/xxx isn't supposed to be shared code. That's was syslib is for.

Ben.

#7 lore raw
Quoted 10 lines · On Sun, 23 Dec 2007 07:58:02 +1100 Benjamin Herrenschmidt…
Quoted 5 lines · Geoff Levand

It seems platforms/cell should have the shared and/or generic code, and the other
stuff moved into a new platform directory, but is it worth the effort?

No, platforms/xxx isn't supposed to be shared code. That's was syslib is for.

I think you mean sysdev?

josh

#8 lore raw
Quoted 6 lines · Josh Boyer
Quoted 2 lines

No, platforms/xxx isn't supposed to be shared code. That's was

syslib is

Quoted 1 line

for.

I think you mean sysdev?

Yeah, whatever the name of the day for that thing is.

(It's syslib in arch/ppc ?)

Ben.

#9 lore raw
In reply to Arnd Bergmann
Quoted 10 lines

A related question is what to do about the location of the other cell related files. platforms/ps3 is already pretty self-contained once we have spufs outside of platforms/cell, but there is still some code shared between platforms/cell and platforms/celleb, and each of these directories also contains code that is only relevant for a subset of the platforms.

My position on these files is that while I find the current state a little bit confusing, I don't have an idea how to do it better either, and I think we should just leave the platform files where they are.

Some of these files could do to syslib, like the io workarounds, rename them spider-io-hacks :-)

Ben.

#10 lore raw
In reply to Arnd Bergmann

Hi all,

Quoted 4 lines

To the question, where what it should go, I'd leave the decision to Jeremy, but my current idea would be:

arch/powerpc/platforms/cell/spufs -> arch/powerpc/spufs

I'd suggest arch/powerpc/sysdev/spufs to keep arch/powerpc clean.

However, this may also depend on the (intended) structure of SPURSEngine support, which may mean that fs/spufs might be a better place. It would suck to have to move things twice, so maybe someone from Tosihba could provide some input? Would the powerpc spufs code be suitable for SPURSEngine?

As thers have posted earlier, i gthink that arch/powerpc/sysdev/cell would be good for the generic cell support, then we could have arch/powerpc/platforms/{cell,ps3,beat} containing only the individual platform code.

Cheers,

Jeremy

#11 lore raw
Quoted 7 lines · Jeremy Kerr

Hi all,

Quoted 4 lines

To the question, where what it should go, I'd leave the decision to Jeremy, but my current idea would be:

arch/powerpc/platforms/cell/spufs -> arch/powerpc/spufs

Quoted 7 lines

I'd suggest arch/powerpc/sysdev/spufs to keep arch/powerpc clean.

However, this may also depend on the (intended) structure of SPURSEngine support, which may mean that fs/spufs might be a better place. It would suck to have to move things twice, so maybe someone from Tosihba could provide some input? Would the powerpc spufs code be suitable for SPURSEngine?

Strong NACK for fs/spufs/ fs code is the smallest part of the spu support, and all this nasty lowlevel code doesn't belong into fs/ at all.

#12 lore raw
Quoted 14 lines · Christoph Hellwig
Quoted 5 lines · Jeremy Kerr
Quoted 4 lines

To the question, where what it should go, I'd leave the decision to Jeremy, but my current idea would be:

arch/powerpc/platforms/cell/spufs -> arch/powerpc/spufs

Quoted 7 lines

I'd suggest arch/powerpc/sysdev/spufs to keep arch/powerpc clean.

However, this may also depend on the (intended) structure of SPURSEngine support, which may mean that fs/spufs might be a better place. It would suck to have to move things twice, so maybe someone from Tosihba could provide some input? Would the powerpc spufs code be suitable for SPURSEngine?

Quoted 3 lines

Strong NACK for fs/spufs/ fs code is the smallest part of the spu support, and all this nasty lowlevel code doesn't belong into fs/ at all.

drivers/spu/?

With kind regards,

Geert Uytterhoeven
Software Architect

Sony Network and Software Technology Center Europe
The Corporate Village · Da Vincilaan 7-D1 · B-1935 Zaventem · Belgium

Phone:    +32 (0)2 700 8453	
Fax:      +32 (0)2 700 8622	
E-mail:   [email protected]	
Internet: http://www.sony-europe.com/

Sony Network and Software Technology Center Europe
A division of Sony Service Centre (Europe) N.V. Registered office: Technologielaan 7 · B-1840 Londerzeel · Belgium VAT BE 0413.825.160 · RPR Brussels
Fortis Bank Zaventem · Swift GEBABEBB08A · IBAN BE39001382358619

#13 lore raw
Quoted 7 lines · Geert Uytterhoeven
Quoted 3 lines · Christoph Hellwig

Strong NACK for fs/spufs/ fs code is the smallest part of the spu support, and all this nasty lowlevel code doesn't belong into fs/ at all.

drivers/spu/?

arch/spu/?

Signature · 4 lines
Luca Barbato
Gentoo Council Member
Gentoo/linux Gentoo/PPC
http://dev.gentoo.org/~lu_zero