Skip to contentSkip to conversation

Raid 1, new disk can't be added after replacing faulty disk

DISCUSSION Radu Rendec 4 participants 6 messages Jan 7, 2008 – Jan 15, 2009 MD RAID

lore
Share & tools
lore
#0 lore raw

I'm experiencing trouble when trying to add a new disk to a raid 1 array after having replaced a faulty disk.

A few details about my configuration:

# cat /proc/mdstat 
Personalities : [raid1] [raid6] [raid5] [raid4] 
md1 : active raid1 sdb3[1]
      151388452 blocks super 1.0 [2/1] [_U]

md0 : active raid1 sdb2[1]

      3911816 blocks super 1.0 [2/1] [_U]

unused devices: <none>

# uname -a
Linux i.ines.ro 2.6.23.8-63.fc8 #1 SMP Wed Nov 21 18:51:08 EST 2007 i686
i686 i386 GNU/Linux
# mdadm --version
mdadm - v2.6.2 - 21st May 2007

So the story is this: disk sda failed and was physically replaced with a new one. The new disk is identical and was partitioned exactly the same way (as the old one and sdb). Getting sda2 (from the fresh empty disk) to the array does not work. This is what happens:

# mdadm /dev/md0 -a /dev/sda2
mdadm: add new device failed for /dev/sda2 as 2: Invalid argument

Kernel messages follow:
md: sda2 does not have a valid v1.0 superblock, not importing!
md: md_import_device returned -22

It's obvious that sda2 does not have a superblock (at all) since it's a fresh empty disk. But I expected mdadm to create the superblock and start rebuilding the array immediately.

However, this happens with both mdadm 2.6.2 and 2.6.4. I downgraded to 2.5.4 and it works like a charm.

If you reply, please add me to cc - I am not subscribed to the list. Should I provide you further details or any kind of assistance for testing, please let me know.

Thanks,

Radu Rendec

#1 lore raw
Quoted 3 lines · Radu Rendec

I'm experiencing trouble when trying to add a new disk to a raid 1 array after having replaced a faulty disk.

[..]

Quoted 3 lines
# mdadm --version
mdadm - v2.6.2 - 21st May 2007

[..]

Quoted 2 lines

However, this happens with both mdadm 2.6.2 and 2.6.4. I downgraded to 2.5.4 and it works like a charm.

Looks like you are running into the issue described here:
http://marc.info/?l=linux-raid&m=119892098129022&w=2

#2 lore raw
Quoted 8 lines · On Monday January 7, [email protected] wrote:
Quoted 3 lines · Radu Rendec

I'm experiencing trouble when trying to add a new disk to a raid 1 array after having replaced a faulty disk.

[..]

Quoted 3 lines
# mdadm --version
mdadm - v2.6.2 - 21st May 2007
Quoted 6 lines

[..]

Quoted 2 lines

However, this happens with both mdadm 2.6.2 and 2.6.4. I downgraded to 2.5.4 and it works like a charm.

Looks like you are running into the issue described here:
http://marc.info/?l=linux-raid&m=119892098129022&w=2

I cannot easily reproduce this. I suspect it is sensitive to the exact size of the devices involved.

Please test this patch and see if it fixes the problem. If not, please tell me the exact sizes of the partition being used (e.g. cat /proc/partitions) and I will try harder to reproduce it.

Thanks,
NeilBrown

super1.c +3 -1
index 2b096d3..9eec460 100644
@@ -903,7 +903,7 @@ static int write_init_super1(struct supertype *st, void *sbv,
 	 * for a bitmap.
 	 */
 	array_size = __le64_to_cpu(sb->size);
-	/* work out how much space we left of a bitmap */
+	/* work out how much space we left for a bitmap */
 	bm_space = choose_bm_space(array_size);
 
 	switch(st->minor_version) {
@@ -913,6 +913,8 @@ static int write_init_super1(struct supertype *st, void *sbv,
 		sb_offset &= ~(4*2-1);
 		sb->super_offset = __cpu_to_le64(sb_offset);
 		sb->data_offset = __cpu_to_le64(0);
+		if (sb_offset - bm_space < array_size)
+			bm_space = sb_offset - array_size;
 		sb->data_size = __cpu_to_le64(sb_offset - bm_space);
 		break;
 	case 1:
#3 lore raw
Quoted 3 lines · Neil Brown
Quoted 2 lines · On Monday January 7, [email protected] wrote:

Looks like you are running into the issue described here:
http://marc.info/?l=linux-raid&m=119892098129022&w=2

Dan, thanks for your quick reply. It's exactly the same issue: the array was created with mdadm 2.5.6.

Quoted 2 lines

I cannot easily reproduce this. I suspect it is sensitive to the exact size of the devices involved.

I reproduced this with 3 different device sizes: 518160384 bytes, 4005711360 bytes and 155021851648 bytes. Is it possible that I hit the "wrong" size every time? Maybe it's related to the disk geometry (because all partitions lay on exact cylinder boundaries, and thus all partitions sizes are multiples of the same cylinder size).

Quoted 3 lines

Please test this patch and see if it fixes the problem. If not, please tell me the exact sizes of the partition being used (e.g. cat /proc/partitions) and I will try harder to reproduce it.

I'll test the patch and get back to you soon.

Thanks,

Radu Rendec

#4 lore raw
In reply to Neil Brown
Quoted 9 lines · Neil Brown
Quoted 3 lines · On Monday January 7, [email protected] wrote:
Quoted 2 lines · Radu Rendec

I'm experiencing trouble when trying to add a new disk to a raid 1 array after having replaced a faulty disk.

I cannot easily reproduce this. I suspect it is sensitive to the exact size of the devices involved.

Please test this patch and see if it fixes the problem.

I successfully applied the patch to v2.6.2 and it fixes the problem. Many thanks for taking the time to look into this issue.

Radu Rendec