GFS2: Don't try and dealloc own inode
When searching for unlinked, but still allocated inodes during block allocation, avoid the block relating to the inode that is doing the allocation. This fixes a hang caused when an unlinked, but still open, inode tries to allocate some more blocks and lands up finding itself during the search for deallocatable inodes.
Signed-off-by Steven Whitehouse <[email protected]>
fs/gfs2/rgrp.c +6 -3
@@ -961,7 +961,8 @@ static int try_rgrp_fit(struct gfs2_rgrpd *rgd, struct gfs2_alloc *al)* Returns: The inode, if one has been found */ -static struct inode *try_rgrp_unlink (struct gfs2_rgrpd *rgd,u64 *last_unlinked) +static struct inode *try_rgrp_unlink (struct gfs2_rgrpd *rgd,u64 *last_unlinked, +u64 skip) {struct inode *inode;u32 goal =0 , block;
@@ -985,6 +986,8 @@ static struct inode *try_rgrp_unlink(struct gfs2_rgrpd *rgd, u64 *last_unlinked) goal++;if (*last_unlinked !=NO_BLOCK && no_addr <= *last_unlinked)continue ; +if (no_addr == skip) +continue ; *last_unlinked = no_addr; inode =gfs2_inode_lookup (rgd->rd_sbd->sd_vfs,DT_UNKNOWN , no_addr,-1 ,1 );
@@ -1104,7 +1107,7 @@ static struct inode *get_local_rgrp(struct gfs2_inode *ip, u64 *last_unlinked)if (try_rgrp_fit (rgd, al)) goto out;if (rgd->rd_flags &GFS2_RDF_CHECK ) - inode =try_rgrp_unlink (rgd, last_unlinked); + inode =try_rgrp_unlink (rgd, last_unlinked, ip->i_no_addr);if (!rg_locked)gfs2_glock_dq_uninit (&al->al_rgd_gh);if (inode)
@@ -1138,7 +1141,7 @@ static struct inode *get_local_rgrp(struct gfs2_inode *ip, u64 *last_unlinked)if (try_rgrp_fit (rgd, al)) goto out;if (rgd->rd_flags &GFS2_RDF_CHECK ) - inode =try_rgrp_unlink (rgd, last_unlinked); + inode =try_rgrp_unlink (rgd, last_unlinked, ip->i_no_addr);if (!rg_locked)gfs2_glock_dq_uninit (&al->al_rgd_gh);if (inode)