Sun StorageTek 2530 and dm?
Hi!
I have StorageTek 2530 storage, which has two controllers. On host side I have LSI LOGIC two SAS port cards. I've connected one cable from LSI port1 to StorageTek ControllerA, and second SAS cable from LSI port2 to StorageTek ControllerB.
On storage, I've set up initiators type to Linux.
But, I just can't get multipath working. For example:
# multipath -ll sdc: checker msg is "readsector0 checker reports path is down" sde: checker msg is "readsector0 checker reports path is down" sdg: checker msg is "readsector0 checker reports path is down" sas-mysql (3600a0b80003abc5c00000b654a916617) dm-1 SUN,LCSM100_S [size=115G][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 1:0:0:1 sdc 8:32 [failed][faulty] \_ 1:0:1:1 sdf 8:80 [active][ready] sas-xen (3600a0b80002fcd18000014544a9166fb) dm-2 SUN,LCSM100_S [size=21G][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ 1:0:1:2 sdg 8:96 [failed][faulty] quorum (3600a0b80002fcd18000014514a9165b4) dm-0 SUN,LCSM100_S [size=100M][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:1:0 sde 8:64 [failed][faulty]
So, all paths on my second controller are failed/faulty....
Here is my multipath.conf:
defaults {
udev_dir /dev
polling_interval 10
selector "round-robin 0"
path_grouping_policy multibus
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
prio_callout /bin/true
path_checker readsector0
rr_min_io 100
max_fds 8192
rr_weight priorities
failback immediate
no_path_retry fail
user_friendly_names yes
}
blacklist {
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
devnode "^hd[a-z]"
}
multipaths {
multipath {
wwid
3600a0b80002fcd18000014544a9166fb
alias sas-xen
path_grouping_policy group_by_prio
path_checker tur
prio_callout "/sbin/mpath_prio_tpc.static /dev/%n"
}
multipath {
wwid
3600a0b80003abc5c00000b654a916617
alias sas-mysql
path_grouping_policy group_by_prio
path_checker tur
prio_callout "/sbin/mpath_prio_tpc.static /dev/%n"
}
multipath {
wwid
3600a0b80002fcd18000014514a9165b4
alias quorum
path_grouping_policy group_by_prio
path_checker tur
prio_callout "/sbin/mpath_prio_tpc.static /dev/%n"
}
}I've also tried:
multipath {
wwid
alias
path_grouping_policy failover
path_checker readsector0
path_selector "round-robin 0"
failback immediate
no_path_retry queue
}for those 3 wwid's...
I'm kinda lost... I've found this, but it is for FC storage, and mine is SAS type...
http://osdir.com/ml/linux.kernel.device-mapper.devel/2007-02/msg00033.html
Thank you...
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 6 lines · On Sun, 23 Aug 2009 21:05:36 +0200 Jakov Sosic <[email protected]> wrote:
Hi!
I have StorageTek 2530 storage, which has two controllers. On host side I have LSI LOGIC two SAS port cards. I've connected one cable from LSI port1 to StorageTek ControllerA, and second SAS cable from LSI port2 to StorageTek ControllerB.
OK. I've solved it - it seems that Linux host type in initiator configuration is not turning on AVT on controllers. Instead, I had to choose "Solaris (with Veritas DMP or other)", and now everything works!
Thank you, and hope this helps to others too.
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 10 lines · Jakov Sosic
Quoted 6 lines · On Sun, 23 Aug 2009 21:05:36 +0200 Jakov Sosic <[email protected]> wrote:
Hi!
I have StorageTek 2530 storage, which has two controllers. On host side I have LSI LOGIC two SAS port cards. I've connected one cable from LSI port1 to StorageTek ControllerA, and second SAS cable from LSI port2 to StorageTek ControllerB.
Quoted 5 lines
OK. I've solved it - it seems that Linux host type in initiator configuration is not turning on AVT on controllers. Instead, I had to choose "Solaris (with Veritas DMP or other)", and now everything works!
Thank you, and hope this helps to others too.
I know that other people here will know more detail, but I think you have another alternative which might be superior.
Instead of changing the initiator configuration to use AVT, you should tune the device mapper to use RDAC.
To do that, I think you will need to adjust both the multipathd configuration and recompile the scsi_dh_rdac kernel module after adding support for "SUN"/"LCSM100_S".
Here's the RDAC multipath.conf I am using with a StorageTek 2510:
Quoted 6 lines · On Mon, 24 Aug 2009 11:41:34 -0400 (EDT) Charlie Brady…
I know that other people here will know more detail, but I think you have another alternative which might be superior.
Instead of changing the initiator configuration to use AVT, you should tune the device mapper to use RDAC.
Quoted 7 lines
To do that, I think you will need to adjust both the multipathd configuration and recompile the
scsi_dh_rdackernel module after adding support for "SUN"/"LCSM100_S".Here's the RDAC multipath.conf I am using with a StorageTek 2510:
Thank you!
The problem is I use XEN kernel from CentOS and I really don't want to mess up with manual compilation of every new kernel that comes out...
Do you know if RedHat incorporated this patch already?
If not, I'll keep up with AVT - it seems that works OK. Some paths fail every now and then but are back online in just a couple of seconds, and that is currently OK.
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
On Mon, 24 Aug 2009 17:48:34 +0200
Jakov Sosic <[email protected]> wrote:
I have this occuring in logs, I presume it is ok?
Aug 24 17:58:43 node01 multipathd: sdc: readsector0 checker reports path is down Aug 24 17:58:43 node01 multipathd: checker failed path 8:32 in map sas-mysql Aug 24 17:58:43 node01 multipathd: sas-mysql: remaining active paths: 1 Aug 24 17:58:43 node01 kernel: device-mapper: multipath: Failing path 8:32. Aug 24 17:58:43 node01 multipathd: dm-1: add map (uevent) Aug 24 17:58:43 node01 multipathd: dm-1: devmap already registered Aug 24 17:58:53 node01 multipathd: sdc: readsector0 checker reports path is up Aug 24 17:58:53 node01 multipathd: 8:32: reinstated Aug 24 17:58:53 node01 multipathd: sas-mysql: remaining active paths: 2 Aug 24 17:58:53 node01 multipathd: dm-1: add map (uevent) Aug 24 17:58:53 node01 multipathd: dm-1: devmap already registered
Because multipath -ll says:
# multipath -ll sas-mysql sas-mysql (3600a0b80003abc5c00000b654a916617) dm-1 SUN,LCSM100_S [size=115G][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 1:0:1:1 sdf 8:80 [active][ready]
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
You need to have a stanza similar to following one for your device in /etc/multipath.conf
--------------------
devices {
device {
vendor "IBM"
product "1815"
path_grouping_policy group_by_prio
hardware_handler "1 rdac"
path_checker rdac
failback immediate
no_path_retry queue
prio_callout "/sbin/mpath_prio_tpc /dev/%n"
}
}
---------------------
Quoted 34 lines · Jakov Sosic
On Mon, 24 Aug 2009 17:48:34 +0200
Jakov Sosic <[email protected]> wrote:I have this occuring in logs, I presume it is ok?
Aug 24 17:58:43 node01 multipathd: sdc: readsector0 checker reports path is down Aug 24 17:58:43 node01 multipathd: checker failed path 8:32 in map sas-mysql Aug 24 17:58:43 node01 multipathd: sas-mysql: remaining active paths: 1 Aug 24 17:58:43 node01 kernel: device-mapper: multipath: Failing path 8:32. Aug 24 17:58:43 node01 multipathd: dm-1: add map (uevent) Aug 24 17:58:43 node01 multipathd: dm-1: devmap already registered Aug 24 17:58:53 node01 multipathd: sdc: readsector0 checker reports path is up Aug 24 17:58:53 node01 multipathd: 8:32: reinstated Aug 24 17:58:53 node01 multipathd: sas-mysql: remaining active paths: 2 Aug 24 17:58:53 node01 multipathd: dm-1: add map (uevent) Aug 24 17:58:53 node01 multipathd: dm-1: devmap already registeredBecause multipath -ll says:
# multipath -ll sas-mysql sas-mysql (3600a0b80003abc5c00000b654a916617) dm-1 SUN,LCSM100_S [size=115G][features=0][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 1:0:1:1 sdf 8:80 [active][ready]
Quoted 17 lines · On Mon, 24 Aug 2009 11:38:18 -0700 Chandra Seetharaman <[email protected]>…
You need to have a stanza similar to following one for your device in
/etc/multipath.conf
--------------------
devices {
device {
vendor "IBM"
product "1815"
path_grouping_policygroup_by_prio
hardware_handler"1 rdac"
path_checkerrdac
failback immediate
no_path_retryqueue
prio_callout"/sbin/mpath_prio_tpc/dev/%n"
}
}
---------------------
Hi!
Yes, I've added that section, and still I get these:
Aug 24 20:47:38 node03 multipathd: 8:16: reinstated Aug 24 20:47:38 node03 multipathd: 8:64: reinstated Aug 24 20:47:38 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:47:38 node03 multipathd: qd: switch to path group #2 Aug 24 20:47:38 node03 multipathd: qd: switch to path group #2 Aug 24 20:47:38 node03 multipathd: dm-0: add map (uevent) Aug 24 20:47:38 node03 multipathd: dm-0: devmap already registered Aug 24 20:47:47 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:47:48 node03 openais[5236]: [CMAN ] lost contact with quorum device Aug 24 20:47:58 node03 multipathd: dm-0: add map (uevent) Aug 24 20:47:58 node03 multipathd: dm-0: devmap already registered Aug 24 20:47:58 node03 multipathd: 8:64: mark as failed Aug 24 20:47:58 node03 kernel: end_request: I/O error, dev sde, sector 8 Aug 24 20:47:58 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:47:58 node03 kernel: device-mapper: multipath: Failing path 8:64. Aug 24 20:47:58 node03 kernel: sd 1:0:0:0: queueing MODE_SELECT command. Aug 24 20:48:07 node03 multipathd: 8:64: reinstated Aug 24 20:48:07 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:48:07 node03 multipathd: qd: switch to path group #2 Aug 24 20:48:07 node03 multipathd: qd: switch to path group #2 Aug 24 20:48:07 node03 multipathd: dm-0: add map (uevent) Aug 24 20:48:07 node03 multipathd: dm-0: devmap already registered Aug 24 20:48:07 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:48:17 node03 multipathd: 8:64: reinstated
So it does not work ok :(
So far I've tried:
1. defaults with initiators set to "Linux"
one path constantly failed
2. AVT with initiators set to "Solaris (with Veritas DMP or other)" multipath flopping constantly - every 20 minutes there is enter in main log about path failing
3. RDAC with initiators set to "Linux"
logs filled with messages like these show up in the message, constantly flip/flopping
I haven't patch scsi_dh_rdac because I don't know how to add support for "SUN"/"LCSM100_S", and although I could figure it out, I'm not really a fan of compiling the kernel if it is not absolutely necessary.
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
I do not think adding that patch would not resolve the=problem you are seeing.
Quoted 74 lines · Jakov Sosic
Quoted 17 lines · On Mon, 24 Aug 2009 11:38:18 -0700 Chandra Seetharaman <[email protected]>…
You need to have a stanza similar to following one for your device in
/etc/multipath.conf
--------------------
devices {
device {
vendor "IBM"
product "1815"
path_grouping_policygroup_by_prio
hardware_handler"1 rdac"
path_checkerrdac
failback immediate
no_path_retryqueue
prio_callout"/sbin/mpath_prio_tpc/dev/%n"
}
}
---------------------Hi!
Yes, I've added that section, and still I get these:
Aug 24 20:47:38 node03 multipathd: 8:16: reinstated Aug 24 20:47:38 node03 multipathd: 8:64: reinstated Aug 24 20:47:38 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:47:38 node03 multipathd: qd: switch to path group #2 Aug 24 20:47:38 node03 multipathd: qd: switch to path group #2 Aug 24 20:47:38 node03 multipathd: dm-0: add map (uevent) Aug 24 20:47:38 node03 multipathd: dm-0: devmap already registered Aug 24 20:47:47 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:47:48 node03 openais[5236]: [CMAN ] lost contact with quorum device Aug 24 20:47:58 node03 multipathd: dm-0: add map (uevent) Aug 24 20:47:58 node03 multipathd: dm-0: devmap already registered Aug 24 20:47:58 node03 multipathd: 8:64: mark as failed Aug 24 20:47:58 node03 kernel: end_request: I/O error, dev sde, sector 8 Aug 24 20:47:58 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:47:58 node03 kernel: device-mapper: multipath: Failing path 8:64. Aug 24 20:47:58 node03 kernel: sd 1:0:0:0: queueing MODE_SELECT command. Aug 24 20:48:07 node03 multipathd: 8:64: reinstated Aug 24 20:48:07 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:48:07 node03 multipathd: qd: switch to path group #2 Aug 24 20:48:07 node03 multipathd: qd: switch to path group #2 Aug 24 20:48:07 node03 multipathd: dm-0: add map (uevent) Aug 24 20:48:07 node03 multipathd: dm-0: devmap already registered Aug 24 20:48:07 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:48:17 node03 multipathd: 8:64: reinstatedSo it does not work ok :(
So far I've tried:
1. defaults with initiators set to "Linux"
one path constantly failed
2. AVT with initiators set to "Solaris (with Veritas DMP or other)" multipath flopping constantly - every 20 minutes there is enter in main log about path failing
3. RDAC with initiators set to "Linux"
logs filled with messages like these show up in the message, constantly flip/floppingI haven't patch
scsi_dh_rdacbecause I don't know how to add support for "SUN"/"LCSM100_S", and although I could figure it out, I'm not really a fan of compiling the kernel if it is not absolutely necessary.
Quoted 2 lines · On Mon, 24 Aug 2009 13:24:16 -0700 Chandra Seetharaman <[email protected]>…
I do not think adding that patch would not resolve the=problem you are seeing.
Too many negations in one sentence - you got me scratching my head on this one :)
Anyway, I'm building the f*** module :( I'm really pissed of :(
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 8 lines · Jakov Sosic
Quoted 2 lines · On Mon, 24 Aug 2009 13:24:16 -0700 Chandra Seetharaman <[email protected]>…
I do not think adding that patch would not resolve the=problem you are seeing.
Too many negations in one sentence - you got me scratching my head on this one :)
ok.. simple words; That patch won't help you.
Quoted 2 lines
Anyway, I'm building the f*** module :( I'm really pissed of :(
This is uncalled for!!
Quoted 3 lines
Quoted 1 line · On Mon, 24 Aug 2009 13:44:34 -0700 Chandra Seetharaman <[email protected]>…
ok.. simple words; That patch won't help you.
hm :( so defining "SUN" "LCMS100_S" won't help? Although in scsi_dh_rdac only "SUN" "LCMS100_F" is defined. And that stands for Fiber, while mine is SAS cabling...
I've recompiled RPM with added patch, then extracted single module (scsi_dh_rdac.ko), and put it in place of the original module...
FATAL: Error inserting scsi_dh_rdac (/lib/modules/2.6.18-128.4.1.el5xen/kernel/drivers/scsi/device_handler/scsi_dh_rdac.ko):
Invalid module format
I guess I'll have to build the whole kernel just because of this :(
Quoted 1 line
This is uncalled for!!
Sorry, I'm easily flammable...
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 8 lines · Jakov Sosic
Quoted 1 line · On Mon, 24 Aug 2009 13:44:34 -0700 Chandra Seetharaman <[email protected]>…
ok.. simple words; That patch won't help you.
hm :( so defining "SUN" "
LCMS100_S" won't help? Although inscsi_dh_rdaconly "SUN" "LCMS100_F" is defined. And that stands for Fiber, while mine is SAS cabling...
Adding this to scsi_dh_rdac makes sure that the module recognizes your device at boot time itself (provided you have it in your initrd image).
Quoted 7 lines
I've recompiled RPM with added patch, then extracted single module (scsi_dh_rdac.ko), and put it in place of the original module...
FATAL: Error inserting
scsi_dh_rdac(/lib/modules/2.6.18-128.4.1.el5xen/kernel/drivers/scsi/device_handler/scsi_dh_rdac.ko):
Invalid module format
Hmm, just that change should cause this. BTW, can you provide the patch you are trying to add.
Can you also provide the (current) o/p of "multipath -ll" and current /etc/multipath.conf.
Quoted 8 lines
I guess I'll have to build the whole kernel just because of this :(
Quoted 1 line
This is uncalled for!!
Sorry, I'm easily flammable...
but doesn't help the cause :).. lets stay objective here :)
Quoted 4 lines
Quoted 3 lines · On Mon, 24 Aug 2009 14:06:01 -0700 Chandra Seetharaman <[email protected]>…
Adding this to
scsi_dh_rdacmakes sure that the module recognizes your device at boot time itself (provided you have it in your initrd image).
Whole kernel rpm didn't help, my patch is obviously failing somewhere, so I'm stuck with that solution.
Should scsi_dh_rdac be in initrd image?
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 9 lines · Jakov Sosic
Quoted 3 lines · On Mon, 24 Aug 2009 14:06:01 -0700 Chandra Seetharaman <[email protected]>…
Adding this to
scsi_dh_rdacmakes sure that the module recognizes your device at boot time itself (provided you have it in your initrd image).Whole kernel rpm didn't help, my patch is obviously failing somewhere, so I'm stuck with that solution.
What is the problem you are seeing ?
Quoted 2 lines
Should
scsi_dh_rdacbe in initrd image?
You need it in initrd image only to get rid of the boottime messages. It is useful only after you add your device to the rdac's devlist.
Quoted 2 lines
Quoted 8 lines · Jakov Sosic
Quoted 1 line · On Mon, 24 Aug 2009 13:44:34 -0700 Chandra Seetharaman <[email protected]>…
ok.. simple words; That patch won't help you.
hm :( so defining "SUN" "
LCMS100_S" won't help? Although inscsi_dh_rdaconly "SUN" "LCMS100_F" is defined. And that stands for Fiber, while mine is SAS cabling...
Chandra says that the patch won't help you. Perhaps he can clarify. My understanding is that if you configure multipath to use RDAC that the driver does have to be patched so that the RDAC handler will be used. I did find that to be the case with the StorageTek 2510 "LCMS100_I").
My understanding also is that RDAC is superior, so RDAC hander support is desirable.
Quoted 8 lines
I've recompiled RPM with added patch, then extracted single module (scsi_dh_rdac.ko), and put it in place of the original module...
FATAL: Error inserting
scsi_dh_rdac(/lib/modules/2.6.18-128.4.1.el5xen/kernel/drivers/scsi/device_handler/scsi_dh_rdac.ko):
Invalid module formatI guess I'll have to build the whole kernel just because of this :(
No, it is certainly possible to build an RPM which contains just the module that you need. But you do need to build correctly.
I did make the suggestion earlier that it would be useful if the module could take load-time parameters to add support for additional devices. I think it was Chandra who agreed that was a good idea and he would add it to the TODO list, but neither he nor I has done that yet.
Quoted 3 lines
Quoted 1 line
This is uncalled for!!
Sorry, I'm easily flammable...
You would be wise to control your urges, if you wish people to help you.
Quoted 8 lines · On Mon, 24 Aug 2009 18:58:24 -0400 (EDT) Charlie Brady…
Chandra says that the patch won't help you. Perhaps he can clarify. My understanding is that if you configure multipath to use RDAC that the driver does have to be patched so that the RDAC handler will be used. I did find that to be the case with the StorageTek 2510 "
LCMS100_I").My understanding also is that RDAC is superior, so RDAC hander support is desirable.
Is it enough to just add a new line to the list of the devices? For example:
const struct scsi_dh_devlist rdac_dev_list[] = {
{"IBM", "1722"},
{"IBM", "1724"},
{"IBM", "1726"},
{"IBM", "1742"},
{"IBM", "1814"},
{"IBM", "1815"},
{"IBM", "1818"},
{"IBM", "3526"},
{"SGI", "TP9400"},
{"SGI", "TP9500"},
{"SGI", "IS"},
{"STK", "OPENstorage D280"},
{"SUN", "CSM200_R"},
{"SUN", "LCSM100_F"},
{"SUN", "LCSM100_I"},
{"SUN", "LCSM100_S"},
{NULL, NULL},
};?
Quoted 4 lines
Quoted 1 line
Sorry, I'm easily flammable...
You would be wise to control your urges, if you wish people to help you.
Well you misunderstood me both - I was just bashing around, and nothing was said at neither yours neither his account. It was just because this project I'm working on is taking so so so long :( This is like 10th problem I've encountered that is out of my order, and the amount of user-hours has already 3-4x exceeded the amount of money project brings :( So I'm really really... angry :-/
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 9 lines · Jakov Sosic
Quoted 6 lines · On Mon, 24 Aug 2009 18:58:24 -0400 (EDT) Charlie Brady…
Chandra says that the patch won't help you. Perhaps he can clarify. My understanding is that if you configure multipath to use RDAC that the driver does have to be patched so that the RDAC handler will be used. I did find that to be the case with the StorageTek 2510 "
LCMS100_I").
Quoted 5 lines
Quoted 2 lines
My understanding also is that RDAC is superior, so RDAC hander support is desirable.
Is it enough to just add a new line to the list of the devices? For example:
yup. But, I mentioned earlier, this _won't_ solve the problem you are seeing.
Quoted 37 lines
const struct scsi_dh_devlist rdac_dev_list[] = { {"IBM", "1722"}, {"IBM", "1724"}, {"IBM", "1726"}, {"IBM", "1742"}, {"IBM", "1814"}, {"IBM", "1815"}, {"IBM", "1818"}, {"IBM", "3526"}, {"SGI", "TP9400"}, {"SGI", "TP9500"}, {"SGI", "IS"}, {"STK", "OPENstorage D280"}, {"SUN", "CSM200_R"}, {"SUN", "LCSM100_F"}, {"SUN", "LCSM100_I"}, {"SUN", "LCSM100_S"}, {NULL, NULL}, };?
Quoted 4 lines
Quoted 1 line
Sorry, I'm easily flammable...
You would be wise to control your urges, if you wish people to help you.
Well you misunderstood me both - I was just bashing around, and nothing was said at neither yours neither his account. It was just because this project I'm working on is taking so so so long :( This is like 10th problem I've encountered that is out of my order, and the amount of user-hours has already 3-4x exceeded the amount of money project brings :( So I'm really really... angry :-/
Quoted 2 lines · On Mon, 24 Aug 2009 16:18:15 -0700 Chandra Seetharaman <[email protected]>…
yup. But, I mentioned earlier, this _won't_ solve the problem you are seeing.
Thank you... I'll try other things then.
The interesting part is, while I was connected only to one controller, and didn't have the multipath, there wasn't any dropouts of that single path.
Now, with multipath, being AVT or RDAC, it works much worse... I just don't get it, why all those flopping is going around :(
And I waited a month to get new SAS cables shipped in - so that a SAS controler would't be a SPOF in my RHCS installation :)
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 7 lines · Charlie Brady
Quoted 5 lines · Jakov Sosic
Quoted 1 line · On Mon, 24 Aug 2009 13:44:34 -0700 Chandra Seetharaman <[email protected]>…
ok.. simple words; That patch won't help you.
Quoted 8 lines
Quoted 3 lines
hm :( so defining "SUN" "
LCMS100_S" won't help? Although inscsi_dh_rdaconly "SUN" "LCMS100_F" is defined. And that stands for Fiber, while mine is SAS cabling...Chandra says that the patch won't help you. Perhaps he can clarify. My understanding is that if you configure multipath to use RDAC that the driver does have to be patched so that the RDAC handler will be used. I did find that to be the case with the StorageTek 2510 "
LCMS100_I").
I didn't mean that scsi_dh_rdac module won't help him. It would.
His device is being handled by the scsi_dh_rdac module once he added the stanza to /etc/multipath.conf file.
But, the problem he is seeing is different and adding this device to the devlist in scsi_dh_rdac wouldn't solve his problem.
Hope it is clear now.
Quoted 31 lines
My understanding also is that RDAC is superior, so RDAC hander support is desirable.
Quoted 8 lines
I've recompiled RPM with added patch, then extracted single module (scsi_dh_rdac.ko), and put it in place of the original module...
FATAL: Error inserting
scsi_dh_rdac(/lib/modules/2.6.18-128.4.1.el5xen/kernel/drivers/scsi/device_handler/scsi_dh_rdac.ko):
Invalid module formatI guess I'll have to build the whole kernel just because of this :(
No, it is certainly possible to build an RPM which contains just the module that you need. But you do need to build correctly.
I did make the suggestion earlier that it would be useful if the module could take load-time parameters to add support for additional devices. I think it was Chandra who agreed that was a good idea and he would add it to the TODO list, but neither he nor I has done that yet.
Quoted 3 lines
Quoted 1 line
This is uncalled for!!
Sorry, I'm easily flammable...
You would be wise to control your urges, if you wish people to help you.
--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Quoted 2 lines · On Mon, 24 Aug 2009 18:58:24 -0400 (EDT) Charlie Brady…
My understanding also is that RDAC is superior, so RDAC hander support is desirable.
PS I don't mind if it is called 'G%#SGA' - as long as it works... I switched to RDAC because apparently AVT is giving me headaches too :( It looses paths every 20 minutes, and with RDAC things are even more problematic so far.
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 6 lines · On Mon, 24 Aug 2009 11:41:34 -0400 (EDT) Charlie Brady…
I know that other people here will know more detail, but I think you have another alternative which might be superior.
Instead of changing the initiator configuration to use AVT, you should tune the device mapper to use RDAC.
Quoted 7 lines
To do that, I think you will need to adjust both the multipathd configuration and recompile the
scsi_dh_rdackernel module after adding support for "SUN"/"LCSM100_S".Here's the RDAC multipath.conf I am using with a StorageTek 2510:
Aug 24 20:25:55 node03 kernel: device-mapper: multipath: Failing path 8:16. Aug 24 20:25:55 node03 multipathd: 8:16: mark as failed Aug 24 20:25:55 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:25:55 node03 multipathd: dm-0: add map (uevent) Aug 24 20:25:55 node03 multipathd: dm-0: devmap already registered Aug 24 20:25:55 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:25:56 node03 qdiskd[5325]: <notice> Score sufficient for master operation (1/1; required=1); upgrading Aug 24 20:26:02 node03 multipathd: 8:16: reinstated Aug 24 20:26:02 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:26:02 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:02 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:02 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:02 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:05 node03 kernel: device-mapper: multipath: Failing path 8:16. Aug 24 20:26:05 node03 multipathd: 8:16: mark as failed Aug 24 20:26:05 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:26:05 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:05 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:05 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:26:12 node03 multipathd: 8:16: reinstated Aug 24 20:26:12 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:26:12 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:12 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:12 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:12 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:15 node03 kernel: device-mapper: multipath: Failing path 8:16. Aug 24 20:26:15 node03 multipathd: 8:16: mark as failed Aug 24 20:26:15 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:26:15 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:15 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:15 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command.
So, your configuration fills my logs too :( I don't know if this is supposed to behave this way or not...
I'm lost now :(
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
This is the expected behavior, when IOs on the active path fails, the hardware handler will activate the passive path and make it active and start sending IOs thru that newly activated path.
Send MODE_SELECT is how the hardware handler makes the passive path active.
Quoted 60 lines · Jakov Sosic
Quoted 6 lines · On Mon, 24 Aug 2009 11:41:34 -0400 (EDT) Charlie Brady…
I know that other people here will know more detail, but I think you have another alternative which might be superior.
Instead of changing the initiator configuration to use AVT, you should tune the device mapper to use RDAC.
Quoted 7 lines
To do that, I think you will need to adjust both the multipathd configuration and recompile the
scsi_dh_rdackernel module after adding support for "SUN"/"LCSM100_S".Here's the RDAC multipath.conf I am using with a StorageTek 2510:
Aug 24 20:25:55 node03 kernel: device-mapper: multipath: Failing path 8:16. Aug 24 20:25:55 node03 multipathd: 8:16: mark as failed Aug 24 20:25:55 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:25:55 node03 multipathd: dm-0: add map (uevent) Aug 24 20:25:55 node03 multipathd: dm-0: devmap already registered Aug 24 20:25:55 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:25:56 node03 qdiskd[5325]: <notice> Score sufficient for master operation (1/1; required=1); upgrading Aug 24 20:26:02 node03 multipathd: 8:16: reinstated Aug 24 20:26:02 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:26:02 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:02 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:02 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:02 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:05 node03 kernel: device-mapper: multipath: Failing path 8:16. Aug 24 20:26:05 node03 multipathd: 8:16: mark as failed Aug 24 20:26:05 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:26:05 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:05 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:05 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:26:12 node03 multipathd: 8:16: reinstated Aug 24 20:26:12 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:26:12 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:12 node03 multipathd: qd: switch to path group #1 Aug 24 20:26:12 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:12 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:15 node03 kernel: device-mapper: multipath: Failing path 8:16. Aug 24 20:26:15 node03 multipathd: 8:16: mark as failed Aug 24 20:26:15 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:26:15 node03 multipathd: dm-0: add map (uevent) Aug 24 20:26:15 node03 multipathd: dm-0: devmap already registered Aug 24 20:26:15 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command.So, your configuration fills my logs too :( I don't know if this is supposed to behave this way or not...
I'm lost now :(
Quoted 6 lines · On Mon, 24 Aug 2009 11:48:36 -0700 Chandra Seetharaman <[email protected]>…
This is the expected behavior, when IOs on the active path fails, the hardware handler will activate the passive path and make it active and start sending IOs thru that newly activated path.
Send
MODE_SELECTis how the hardware handler makes the passive path active.
Yes, I am aware of the multipathing and switching in case of failure - but what is bugging me is why is it happening so often? Or can I be more precise - why is it happening CONSTANTLY?
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Have you verified there is no physical issues with the path ?
Quoted 16 lines · Jakov Sosic
Quoted 6 lines · On Mon, 24 Aug 2009 11:48:36 -0700 Chandra Seetharaman <[email protected]>…
This is the expected behavior, when IOs on the active path fails, the hardware handler will activate the passive path and make it active and start sending IOs thru that newly activated path.
Send
MODE_SELECTis how the hardware handler makes the passive path active.Yes, I am aware of the multipathing and switching in case of failure - but what is bugging me is why is it happening so often? Or can I be more precise - why is it happening CONSTANTLY?
Quoted 1 line · On Mon, 24 Aug 2009 13:24:57 -0700 Chandra Seetharaman <[email protected]>…
Have you verified there is no physical issues with the path ?
Yes, because both paths are flopping, and other LUN's on the same path's are not flopping as much - but are not written as much. This is a quorum disk for RHEL cluster that is flopping constantly.
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 9 lines · Jakov Sosic
Quoted 1 line · On Mon, 24 Aug 2009 13:24:57 -0700 Chandra Seetharaman <[email protected]>…
Have you verified there is no physical issues with the path ?
Yes, because both paths are flopping, and other LUN's on the same path's are not flopping as much - but are not written as much. This is a quorum disk for RHEL cluster that is flopping constantly.
Quoted 13 lines
Aug 24 20:47:38 node03 multipathd: 8:16: reinstated Aug 24 20:47:38 node03 multipathd: 8:64: reinstated Aug 24 20:47:38 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:47:38 node03 multipathd: qd: switch to path group #2 Aug 24 20:47:38 node03 multipathd: qd: switch to path group #2 Aug 24 20:47:38 node03 multipathd: dm-0: add map (uevent) Aug 24 20:47:38 node03 multipathd: dm-0: devmap already registered Aug 24 20:47:47 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:47:48 node03 openais[5236]: [CMAN ] lost contact with quorum device Aug 24 20:47:58 node03 multipathd: dm-0: add map (uevent) Aug 24 20:47:58 node03 multipathd: dm-0: devmap already registered Aug 24 20:47:58 node03 multipathd: 8:64: mark as failed Aug 24 20:47:58 node03 kernel: end_request: I/O error, dev sde, sector 8
This does mean that the IO had really failed in that path....
Quoted 2 lines
Aug 24 20:47:58 node03 multipathd: qd: remaining active paths: 1 Aug 24 20:47:58 node03 kernel: device-mapper: multipath: Failing path 8:64.
... based on which the kernel failed the path....
Quoted 2 lines
Aug 24 20:47:58 node03 kernel: sd 1:0:0:0: queueing MODE_SELECT command. Aug 24 20:48:07 node03 multipathd: 8:64: reinstated
... only after 10 seconds the path is back.
If you are up for debugging, we can try putting some debug to see if we are getting any sense information along with the IO failure.
Quoted 8 lines
Aug 24 20:48:07 node03 multipathd: qd: remaining active paths: 2 Aug 24 20:48:07 node03 multipathd: qd: switch to path group #2 Aug 24 20:48:07 node03 multipathd: qd: switch to path group #2 Aug 24 20:48:07 node03 multipathd: dm-0: add map (uevent) Aug 24 20:48:07 node03 multipathd: dm-0: devmap already registered Aug 24 20:48:07 node03 kernel: sd 1:0:1:0: queueing MODE_SELECT command. Aug 24 20:48:17 node03 multipathd: 8:64: reinstated
Quoted 2 lines · On Mon, 24 Aug 2009 13:57:31 -0700 Chandra Seetharaman <[email protected]>…
If you are up for debugging, we can try putting some debug to see if we are getting any sense information along with the IO failure.
OK, here is the dmesg from last reboot, only things that are of importance to this case:
SCSI subsystem initialized
Fusion MPT base driver 3.04.07
Copyright (c) 1999-2008 LSI Corporation
Fusion MPT SAS Host driver 3.04.07
ACPI: PCI Interrupt 0000:07:00.0[A] -> GSI 17 (level, low) -> IRQ 17
mptbase: ioc0: Initiating bringup
...
mptbase: ioc1: Initiating bringup
ioc1: LSISAS1068E B3: Capabilities={Initiator}
PCI: Setting latency timer of device 0000:09:00.0 to 64 scsi1 : ioc1: LSISAS1068E B3, FwRev=011704dbh, Ports=1, MaxQ=829, IRQ=22
Vendor: SUN Model: LCSM100_S Rev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdb: 204800 512-byte hdwr sectors (105 MB)
sdb: Write Protect is off
sdb: Mode Sense: 77 00 10 08
SCSI device sdb: drive cache: write back w/ FUA
SCSI device sdb: 204800 512-byte hdwr sectors (105 MB)
sdb: Write Protect is off
sdb: Mode Sense: 77 00 10 08
SCSI device sdb: drive cache: write back w/ FUA
sdb:end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0
Dev sdb: unable to read RDB block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0
unable to read partition table
sd 1:0:0:0: Attached scsi disk sdb
Vendor: SUN Model: LCSM100_S Rev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdc: 241172480 512-byte hdwr sectors (123480 MB)
sdc: Write Protect is off
sdc: Mode Sense: 77 00 10 08
SCSI device sdc: drive cache: write back w/ FUA
SCSI device sdc: 241172480 512-byte hdwr sectors (123480 MB)
sdc: Write Protect is off
sdc: Mode Sense: 77 00 10 08
SCSI device sdc: drive cache: write back w/ FUA
sdc:end_request: I/O error, dev sdc, sector 0
Buffer I/O error on device sdc, logical block 0end_request: I/O error, dev sdc, sector 0
Buffer I/O error on device sdc, logical block 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0
Dev sdc: unable to read RDB block 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0
unable to read partition table
sd 1:0:0:1: Attached scsi disk sdc
Vendor: SUN Model: LCSM100_S Rev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdd: 43274240 512-byte hdwr sectors (22156 MB)
sdd: Write Protect is off
sdd: Mode Sense: 77 00 10 08
SCSI device sdd: drive cache: write back w/ FUA
SCSI device sdd: 43274240 512-byte hdwr sectors (22156 MB)
sdd: Write Protect is off
sdd: Mode Sense: 77 00 10 08
SCSI device sdd: drive cache: write back w/ FUA
sdd: unknown partition table
sd 1:0:0:2: Attached scsi disk sdd
Vendor: SUN Model: LCSM100_S Rev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sde: 204800 512-byte hdwr sectors (105 MB)
sde: Write Protect is off
sde: Mode Sense: 77 00 10 08
SCSI device sde: drive cache: write back w/ FUA
SCSI device sde: 204800 512-byte hdwr sectors (105 MB)
sde: Write Protect is off
sde: Mode Sense: 77 00 10 08
SCSI device sde: drive cache: write back w/ FUA
sde:end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0
printk: 8 messages suppressed.
Buffer I/O error on device sde, logical block 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0
Dev sde: unable to read RDB block 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0
unable to read partition table
sd 1:0:1:0: Attached scsi disk sde
Vendor: SUN Model: LCSM100_S Rev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdf: 241172480 512-byte hdwr sectors (123480 MB)
sdf: Write Protect is off
sdf: Mode Sense: 77 00 10 08
SCSI device sdf: drive cache: write back w/ FUA
SCSI device sdf: 241172480 512-byte hdwr sectors (123480 MB)
sdf: Write Protect is off
sdf: Mode Sense: 77 00 10 08
SCSI device sdf: drive cache: write back w/ FUA
sdf: unknown partition table
sd 1:0:1:1: Attached scsi disk sdf
Vendor: SUN Model: LCSM100_S Rev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdg: 43274240 512-byte hdwr sectors (22156 MB)
sdg: Write Protect is off
sdg: Mode Sense: 77 00 10 08
SCSI device sdg: drive cache: write back w/ FUA
SCSI device sdg: 43274240 512-byte hdwr sectors (22156 MB)
sdg: Write Protect is off
sdg: Mode Sense: 77 00 10 08
SCSI device sdg: drive cache: write back w/ FUA
sdg:end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0
printk: 8 messages suppressed.
Buffer I/O error on device sdg, logical block 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0
Dev sdg: unable to read RDB block 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0
unable to read partition table
sd 1:0:1:2: Attached scsi disk sdg
shpchp: Standard Hot Plug PCI Controller Driver version: 0.4 libata version 3.00 loaded.
Now, this seems like some kind of a problem on the LCMS100_S driver side? MPT_SAS?
Very strange...
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
These messages are seen because there is no support for this device in-built in the scsi_dh_rdac module.
These will disappear when youadded the device support to scsi_dh_rdac module and include the module in your initrd image.
Quoted 162 lines · Jakov Sosic
Quoted 2 lines · On Mon, 24 Aug 2009 13:57:31 -0700 Chandra Seetharaman <[email protected]>…
If you are up for debugging, we can try putting some debug to see if we are getting any sense information along with the IO failure.
OK, here is the dmesg from last reboot, only things that are of importance to this case:
SCSI subsystem initialized
Fusion MPT base driver 3.04.07
Copyright (c) 1999-2008 LSI Corporation
Fusion MPT SAS Host driver 3.04.07
ACPI: PCI Interrupt 0000:07:00.0[A] -> GSI 17 (level, low) -> IRQ 17
mptbase: ioc0: Initiating bringup...
mptbase: ioc1: Initiating bringup
ioc1: LSISAS1068E B3: Capabilities={Initiator}
PCI: Setting latency timer of device 0000:09:00.0 to 64 scsi1 : ioc1: LSISAS1068E B3, FwRev=011704dbh, Ports=1, MaxQ=829, IRQ=22
Vendor: SUN Model:LCSM100_SRev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdb: 204800 512-byte hdwr sectors (105 MB)
sdb: Write Protect is off
sdb: Mode Sense: 77 00 10 08
SCSI device sdb: drive cache: write back w/ FUA
SCSI device sdb: 204800 512-byte hdwr sectors (105 MB)
sdb: Write Protect is off
sdb: Mode Sense: 77 00 10 08
SCSI device sdb: drive cache: write back w/ FUA
sdb:end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0
Dev sdb: unable to read RDB block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0
unable to read partition table
sd 1:0:0:0: Attached scsi disk sdb
Vendor: SUN Model:LCSM100_SRev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdc: 241172480 512-byte hdwr sectors (123480 MB)
sdc: Write Protect is off
sdc: Mode Sense: 77 00 10 08
SCSI device sdc: drive cache: write back w/ FUA
SCSI device sdc: 241172480 512-byte hdwr sectors (123480 MB)
sdc: Write Protect is off
sdc: Mode Sense: 77 00 10 08
SCSI device sdc: drive cache: write back w/ FUA
sdc:end_request: I/O error, dev sdc, sector 0
Buffer I/O error on device sdc, logical block 0end_request: I/O error, dev sdc, sector 0
Buffer I/O error on device sdc, logical block 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0
Dev sdc: unable to read RDB block 0end_request: I/O error, dev sdc, sector 0end_request: I/O error, dev sdc, sector 0
unable to read partition table
sd 1:0:0:1: Attached scsi disk sdc
Vendor: SUN Model:LCSM100_SRev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdd: 43274240 512-byte hdwr sectors (22156 MB)
sdd: Write Protect is off
sdd: Mode Sense: 77 00 10 08
SCSI device sdd: drive cache: write back w/ FUA
SCSI device sdd: 43274240 512-byte hdwr sectors (22156 MB)
sdd: Write Protect is off
sdd: Mode Sense: 77 00 10 08
SCSI device sdd: drive cache: write back w/ FUA
sdd: unknown partition table
sd 1:0:0:2: Attached scsi disk sdd
Vendor: SUN Model:LCSM100_SRev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sde: 204800 512-byte hdwr sectors (105 MB)
sde: Write Protect is off
sde: Mode Sense: 77 00 10 08
SCSI device sde: drive cache: write back w/ FUA
SCSI device sde: 204800 512-byte hdwr sectors (105 MB)
sde: Write Protect is off
sde: Mode Sense: 77 00 10 08
SCSI device sde: drive cache: write back w/ FUA
sde:end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0
printk: 8 messages suppressed.
Buffer I/O error on device sde, logical block 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0
Dev sde: unable to read RDB block 0end_request: I/O error, dev sde, sector 0end_request: I/O error, dev sde, sector 0
unable to read partition table
sd 1:0:1:0: Attached scsi disk sde
Vendor: SUN Model:LCSM100_SRev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdf: 241172480 512-byte hdwr sectors (123480 MB)
sdf: Write Protect is off
sdf: Mode Sense: 77 00 10 08
SCSI device sdf: drive cache: write back w/ FUA
SCSI device sdf: 241172480 512-byte hdwr sectors (123480 MB)
sdf: Write Protect is off
sdf: Mode Sense: 77 00 10 08
SCSI device sdf: drive cache: write back w/ FUA
sdf: unknown partition table
sd 1:0:1:1: Attached scsi disk sdf
Vendor: SUN Model:LCSM100_SRev: 0735
Type: Direct-Access ANSI SCSI revision: 05
SCSI device sdg: 43274240 512-byte hdwr sectors (22156 MB)
sdg: Write Protect is off
sdg: Mode Sense: 77 00 10 08
SCSI device sdg: drive cache: write back w/ FUA
SCSI device sdg: 43274240 512-byte hdwr sectors (22156 MB)
sdg: Write Protect is off
sdg: Mode Sense: 77 00 10 08
SCSI device sdg: drive cache: write back w/ FUA
sdg:end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0
printk: 8 messages suppressed.
Buffer I/O error on device sdg, logical block 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0
Dev sdg: unable to read RDB block 0end_request: I/O error, dev sdg, sector 0end_request: I/O error, dev sdg, sector 0
unable to read partition table
sd 1:0:1:2: Attached scsi disk sdg
shpchp: Standard Hot Plug PCI Controller Driver version: 0.4 libata version 3.00 loaded.Now, this seems like some kind of a problem on the
LCMS100_Sdriver side?MPT_SAS?Very strange...
Quoted 5 lines · On Mon, 24 Aug 2009 14:41:56 -0700 Chandra Seetharaman <[email protected]>…
These messages are seen because there is no support for this device in-built in the
scsi_dh_rdacmodule.These will disappear when youadded the device support to
scsi_dh_rdacmodule and include the module in your initrd image.
Now if I understand correctly - because my device is not supported by scsi_dh_rdac - RDAC is not functional at all? Because later in the dmesg, it shows
sd 1:0:1:0: rdac: LUN 0 (owned)
sd 1:0:0:0: rdac: LUN 0 (unowned)
which suggests that RDAC is working after all?
Here is my current multipath.conf (Sbeaf_11 and Sbeaf_21 are iSCSI targets that work flawlessly):
defaults {
user_friendly_names yes
}
defaults {
udev_dir /dev
polling_interval 10
selector "round-robin 0"
path_grouping_policy multibus
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
prio_callout /bin/true
path_checker readsector0
rr_min_io 100
max_fds 8192
rr_weight priorities
failback immediate
no_path_retry fail
user_friendly_names yes
}
blacklist {
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
devnode "^hd[a-z]"
}
multipaths {
multipath {
wwid S_beaf11
alias controller0
path_grouping_policy failover
path_checker readsector0
path_selector "round-robin 0"
failback immediate
no_path_retry queue
}
multipath {
wwid S_beaf21
alias controller1
path_grouping_policy failover
path_checker readsector0
path_selector "round-robin 0"
failback immediate
no_path_retry queue
}
multipath {
wwid
3600a0b80002fcd18000014544a9166fb
alias sas-xen
}
multipath {
wwid
3600a0b80003abc5c00000b654a916617
alias sas-mysql
}
multipath {
wwid
3600a0b80002fcd18000014514a9165b4
alias qd
}
}devices {
device {
vendor "SUN"
product "LCSM100_S"
getuid_callout "/sbin/scsi_id -g -u
-s /block/%n"
prio_callout "/sbin/mpath_prio_tpc /dev/%n"
hardware_handler "1 rdac"
path_grouping_policy group_by_prio
path_checker rdac
failback immediate
rr_weight uniform
no_path_retry queue
rr_min_io 1000
}
}And here is the multipath -ll:
# multipath -ll qd (3600a0b80002fcd18000014514a9165b4) dm-0 SUN,LCSM100_S [size=100M][features=1 queue_if_no_path][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=3][active] \_ 1:0:1:0 sde 8:64 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:0:0 sdb 8:16 [active][ghost] controller1 (S_beaf21) dm-4 IET,VIRTUAL-DISK [size=3.4T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 8:0:0:1 sdk 8:160 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 9:0:0:1 sdj 8:144 [active][ready] controller0 (S_beaf11) dm-3 IET,VIRTUAL-DISK [size=3.4T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 10:0:0:1 sdh 8:112 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 11:0:0:1 sdi 8:128 [active][ready] sas-mysql (3600a0b80003abc5c00000b654a916617) dm-1 SUN,LCSM100_S [size=115G][features=1 queue_if_no_path][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=3][active] \_ 1:0:1:1 sdf 8:80 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:0:1 sdc 8:32 [active][ghost] sas-xen (3600a0b80002fcd18000014544a9166fb) dm-2 SUN,LCSM100_S [size=21G][features=1 queue_if_no_path][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=3][active] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:1:2 sdg 8:96 [active][ghost]
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 11 lines · Jakov Sosic
Quoted 5 lines · On Mon, 24 Aug 2009 14:41:56 -0700 Chandra Seetharaman <[email protected]>…
These messages are seen because there is no support for this device in-built in the
scsi_dh_rdacmodule.These will disappear when youadded the device support to
scsi_dh_rdacmodule and include the module in your initrd image.Now if I understand correctly - because my device is not supported by
scsi_dh_rdac- RDAC is not functional at all? Because
If your device was in the list, then you wouldn't seen multiples of those error messages and would have seen the following message at boot time itself.
Quoted 4 lines
later in the dmesg, it shows
sd 1:0:1:0: rdac: LUN 0 (owned)
sd 1:0:0:0: rdac: LUN 0 (unowned)
scsi_dh_rdac modules is insmodded by multipath when multipathd is started (by virtue of you having hardware_handler "1 rdac" in your /etc/muliutpath.conf file.
So, it is effective when multipath starts.
Quoted 130 lines
which suggests that RDAC is working after all?
Here is my current multipath.conf (
Sbeaf_11andSbeaf_21are iSCSI targets that work flawlessly):defaults {
user_friendly_namesyes
}defaults { udev_dir /dev polling_interval 10 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout /bin/true path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes } blacklist { devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" } multipaths { multipath { wwid S_beaf11 alias controller0 path_grouping_policy failover path_checker readsector0 path_selector "round-robin 0" failback immediate no_path_retry queue } multipath { wwid S_beaf21 alias controller1 path_grouping_policy failover path_checker readsector0 path_selector "round-robin 0" failback immediate no_path_retry queue } multipath { wwid 3600a0b80002fcd18000014544a9166fb alias sas-xen } multipath { wwid 3600a0b80003abc5c00000b654a916617 alias sas-mysql } multipath { wwid 3600a0b80002fcd18000014514a9165b4 alias qd } }devices { device { vendor "SUN" product "LCSM100_S" getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout "/sbin/mpath_prio_tpc /dev/%n" hardware_handler "1 rdac" path_grouping_policy group_by_prio path_checker rdac failback immediate rr_weight uniform no_path_retry queue rr_min_io 1000 } }And here is the multipath -ll:
# multipath -ll qd (3600a0b80002fcd18000014514a9165b4) dm-0 SUN,LCSM100_S [size=100M][features=1 queue_if_no_path][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=3][active] \_ 1:0:1:0 sde 8:64 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:0:0 sdb 8:16 [active][ghost] controller1 (S_beaf21) dm-4 IET,VIRTUAL-DISK [size=3.4T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 8:0:0:1 sdk 8:160 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 9:0:0:1 sdj 8:144 [active][ready] controller0 (S_beaf11) dm-3 IET,VIRTUAL-DISK [size=3.4T][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=0][active] \_ 10:0:0:1 sdh 8:112 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 11:0:0:1 sdi 8:128 [active][ready] sas-mysql (3600a0b80003abc5c00000b654a916617) dm-1 SUN,LCSM100_S [size=115G][features=1 queue_if_no_path][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=3][active] \_ 1:0:1:1 sdf 8:80 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:0:1 sdc 8:32 [active][ghost] sas-xen (3600a0b80002fcd18000014544a9166fb) dm-2 SUN,LCSM100_S [size=21G][features=1 queue_if_no_path][hwhandler=1 rdac][rw] \_ round-robin 0 [prio=3][active] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:1:2 sdg 8:96 [active][ghost]
Quoted 5 lines · On Mon, 24 Aug 2009 16:07:22 -0700 Chandra Seetharaman <[email protected]>…
scsi_dh_rdacmodules is insmodded by multipath when multipathd is started (by virtue of you havinghardware_handler"1 rdac" in your/etc/muliutpath.conffile.So, it is effective when multipath starts.
If it is effective, I don't need to patch it... Thank you very much.
You were saying that you could provide some debugging code if I'm interested? Well it seems that I don't have a choice... So please do so :)
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 3 lines · On Tue, 25 Aug 2009 01:13:40 +0200 Jakov Sosic <[email protected]> wrote:
You were saying that you could provide some debugging code if I'm interested? Well it seems that I don't have a choice... So please do so :)
Also, I've found that Sun provides RDAC driver for 2.6 kernels... I brings whole framework, with config files and additional commands...
I don't like the idea, but because neither the AVT neither the RDAC on dm-multipath are working correctly, I'll try the Sun RDAC solution tommorow and post the results.
Here is the explanation (and link to source is within the document):
http://dlc.sun.com/pdf/820-4738-12/820-4738-12.pdf
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 7 lines · Jakov Sosic
Quoted 4 lines · On Mon, 24 Aug 2009 16:07:22 -0700 Chandra Seetharaman <[email protected]>…
scsi_dh_rdacmodules is insmodded by multipath when multipathd is started (by virtue of you havinghardware_handler"1 rdac" in your/etc/muliutpath.conffile.
Quoted 8 lines
Quoted 1 line
So, it is effective when multipath starts.
If it is effective, I don't need to patch it... Thank you very much.
You were saying that you could provide some debugging code if I'm interested? Well it seems that I don't have a choice... So please do so :)
Basically I want to find out if we are getting and sense codes that we are not handling. To that effect, andd the following line at the top of the function rdac_check_sense()
--------
sdev_printk(KERN_ERR, sdev, "I/O returned with sense %02x/%02x/%02x",
sense_hdr->sense_key, sense_hdr->asc, sense_hdr->ascq);
---------
compile the module, run your tests and get me /var/log/messages.
Quoted 2 lines
Quoted 21 lines · Chandra Seetharaman
Quoted 7 lines · Jakov Sosic
Quoted 4 lines · On Mon, 24 Aug 2009 16:07:22 -0700 Chandra Seetharaman <[email protected]>…
scsi_dh_rdacmodules is insmodded by multipath when multipathd is started (by virtue of you havinghardware_handler"1 rdac" in your/etc/muliutpath.conffile.Quoted 8 lines
Quoted 1 line
So, it is effective when multipath starts.
If it is effective, I don't need to patch it... Thank you very much.
You were saying that you could provide some debugging code if I'm interested? Well it seems that I don't have a choice... So please do so :)
Basically I want to find out if we are getting and sense codes that we are not handling. To that effect, andd the following line at the top of the function
rdac_check_sense()
--------
sdev_printk(KERN_ERR, sdev, "I/O returned with sense %02x/%02x/%02x",
Quoted 4 lines
sense_hdr->sense_key, sense_hdr->asc, sense_hdr->ascq);---------
compile the module, run your tests and get me
/var/log/messages.
Might this be the same issue as you worked through with Babu last October?
http://kerneltrap.org/mailarchive/linux-scsi/2008/10/24/3803244
Hopefully not :)... it has been fixed for a while.
Jacov, Can you send me the scsi_dh_rdac.c file. I want to make sure you are running the latest code.
Quoted 36 lines · Charlie Brady
Quoted 21 lines · Chandra Seetharaman
Quoted 7 lines · Jakov Sosic
Quoted 4 lines · On Mon, 24 Aug 2009 16:07:22 -0700 Chandra Seetharaman <[email protected]>…
scsi_dh_rdacmodules is insmodded by multipath when multipathd is started (by virtue of you havinghardware_handler"1 rdac" in your/etc/muliutpath.conffile.Quoted 8 lines
Quoted 1 line
So, it is effective when multipath starts.
If it is effective, I don't need to patch it... Thank you very much.
You were saying that you could provide some debugging code if I'm interested? Well it seems that I don't have a choice... So please do so :)
Basically I want to find out if we are getting and sense codes that we are not handling. To that effect, andd the following line at the top of the function
rdac_check_sense()
--------
sdev_printk(KERN_ERR, sdev, "I/O returned with sense %02x/%02x/%02x",Quoted 4 lines
sense_hdr->sense_key, sense_hdr->asc, sense_hdr->ascq);---------
compile the module, run your tests and get me
/var/log/messages.Might this be the same issue as you worked through with Babu last October?
http://kerneltrap.org/mailarchive/linux-scsi/2008/10/24/3803244
--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Quoted 4 lines · Chandra Seetharaman
Hopefully not :)... it has been fixed for a while.
Jacov, Can you send me the
scsi_dh_rdac.cfile. I want to make sure you are running the latest code.
Jacov told us that he was running 2.6.18-128.4.1.el5xen, which certainly isn't the latest code. It's the latest Red Hat RHEL5 code (or rather, was until yesterday).
Below are the diffs from linus's git repo. I'd guess that there would be minor changes needed before the current code would compile and run with the RHEL5 kernel.
Chandra, can you spot any one or two patches that would be most important to back-port to RHEL5?
home/speech/bradyc/scsi_dh_rdac.c renamed from linux-2.6.18.i386/drivers/scsi/device_handler/scsi_dh_rdac.c +87 -46
@@ -19,14 +19,12 @@* Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA. * */ -#include <linux/list.h> #include <scsi/scsi.h> #include <scsi/scsi_eh.h> -#include <scsi/scsi_cmnd.h> #include <scsi/scsi_dh.h> -#include "../scsi_priv.h" #define RDAC_NAME "rdac" +#define RDAC_RETRY_COUNT 5/* * LSI mode page stuff
@@ -202,7 +200,7 @@static inline struct rdac_dh_data *get_rdac_data (struct scsi_device *sdev) { -struct scsi_dh_data *scsi_dh_data =retrieve_scsi_dh_data (sdev); +struct scsi_dh_data *scsi_dh_data = sdev->scsi_dh_data;BUG_ON (scsi_dh_data ==NULL );return ((struct rdac_dh_data *) scsi_dh_data->buf); }
@@ -228,10 +226,9 @@return NULL ; } -memset (rq->cmd,0 ,BLK_MAX_CDB ); - - rq->flags |=REQ_FAILFAST_DEV |REQ_FAILFAST_TRANSPORT | -REQ_FAILFAST_DRIVER |REQ_NOMERGE |REQ_BLOCK_PC ; + rq->cmd_type =REQ_TYPE_BLOCK_PC ; + rq->cmd_flags |=REQ_FAILFAST_DEV |REQ_FAILFAST_TRANSPORT | +REQ_FAILFAST_DRIVER ; rq->retries =RDAC_RETRIES ; rq->timeout =RDAC_TIMEOUT ;
@@ -390,6 +387,7 @@struct c9_inquiry *inqp; h->lun_state =RDAC_LUN_UNOWNED ; + h->state =RDAC_STATE_ACTIVE ; err =submit_inquiry (sdev,0xC9 ,sizeof (struct c9_inquiry ), h);if (err ==SCSI_DH_OK ) { inqp = &h->inq.c9;
@@ -407,6 +405,7 @@if (h->lun_state ==RDAC_LUN_UNOWNED ) h->state =RDAC_STATE_PASSIVE ; +return err; }
@@ -450,28 +449,40 @@ unsigned char *sensebuf) {struct scsi_sense_hdr sense_hdr; -int sense, err =SCSI_DH_IO , ret; +int err =SCSI_DH_IO , ret; ret =scsi_normalize_sense (sensebuf,SCSI_SENSE_BUFFERSIZE , &sense_hdr);if (!ret) goto done; err =SCSI_DH_OK ; - sense = (sense_hdr.sense_key <<16 ) | (sense_hdr.asc <<8 ) | - sense_hdr.ascq; -/* If it is retryable failure, submit the c9 inquiry again */ -if (sense ==0x59136 || sense ==0x68b02 || sense ==0xb8b02 || - sense ==0x62900 ) { -/* 0x59136 - Command lock contention -* 0x[6b]8b02 - Quiesense in progress or achieved -* 0x62900 - Power On, Reset, or Bus Device Reset -*/ + +switch (sense_hdr.sense_key) { +case NO_SENSE : +case ABORTED_COMMAND : +case UNIT_ATTENTION : err =SCSI_DH_RETRY ; +break ; +case NOT_READY : +if (sense_hdr.asc ==0x04 && sense_hdr.ascq ==0x01 ) +/* LUN Not Ready and is in the Process of Becoming +* Ready +*/ + err =SCSI_DH_RETRY ; +break ; +case ILLEGAL_REQUEST : +if (sense_hdr.asc ==0x91 && sense_hdr.ascq ==0x36 ) +/* +* Command Lock contention +*/ + err =SCSI_DH_RETRY ; +break ; +default : +sdev_printk (KERN_INFO , sdev, +"MODE_SELECT failed with sense %02x/%02x/%02x.\n" , + sense_hdr.sense_key, sense_hdr.asc, sense_hdr.ascq); } -if (sense) -sdev_printk (KERN_INFO , sdev, -"MODE_SELECT failed with sense 0x%x.\n" , sense); done:return err; }
@@ -480,21 +491,27 @@ {struct request *rq;struct request_queue *q = sdev->request_queue; -int err =SCSI_DH_RES_TEMP_UNAVAIL ; +int err, retry_cnt =RDAC_RETRY_COUNT ; +retry: + err =SCSI_DH_RES_TEMP_UNAVAIL ; rq =rdac_failover_get (sdev, h);if (!rq) goto done; -sdev_printk (KERN_INFO , sdev,"queueing MODE_SELECT command.\n" ); +sdev_printk (KERN_INFO , sdev,"%s MODE_SELECT command.\n" , + (retry_cnt ==RDAC_RETRY_COUNT ) ?"queueing" :"retrying" ); err =blk_execute_rq (q,NULL , rq,1 ); -if (err !=SCSI_DH_OK ) +blk_put_request (rq); +if (err !=SCSI_DH_OK ) { err =mode_select_handle_sense (sdev, h->sense); +if (err ==SCSI_DH_RETRY && retry_cnt--) + goto retry; + }if (err ==SCSI_DH_OK ) h->state =RDAC_STATE_ACTIVE ; -blk_put_request (rq); done:return err; }
@@ -532,7 +549,7 @@if (h->state !=RDAC_STATE_ACTIVE ) { ret =BLKPREP_KILL ; - req->flags |=REQ_QUIET ; + req->cmd_flags |=REQ_QUIET ; }return ret;
@@ -544,19 +561,31 @@struct rdac_dh_data *h =get_rdac_data (sdev);switch (sense_hdr->sense_key) {case NOT_READY : +if (sense_hdr->asc ==0x04 && sense_hdr->ascq ==0x01 ) +/* LUN Not Ready - Logical Unit Not Ready and is in +* the process of becoming ready +* Just retry. +*/ +return ADD_TO_MLQUEUE ;if (sense_hdr->asc ==0x04 && sense_hdr->ascq ==0x81 )/* LUN Not Ready - Storage firmware incompatible * Manual code synchonisation required. * * Nothing we can do here. Try to bypass the path. */ -return SCSI_MLQUEUE_DIS_FINISH ; +return SUCCESS ;if (sense_hdr->asc ==0x04 && sense_hdr->ascq ==0xA1 )/* LUN Not Ready - Quiescense in progress * * Just retry and wait. */ -return SCSI_MLQUEUE_IMM_RETRY ; +return ADD_TO_MLQUEUE ; +if (sense_hdr->asc ==0xA1 && sense_hdr->ascq ==0x02 ) +/* LUN Not Ready - Quiescense in progress +* or has been achieved +* Just retry. +*/ +return ADD_TO_MLQUEUE ;break ;case ILLEGAL_REQUEST :if (sense_hdr->asc ==0x94 && sense_hdr->ascq ==0x01 ) {
@@ -565,7 +594,7 @@* Fail the path, so that the other path be used. */ h->state =RDAC_STATE_PASSIVE ; -return SCSI_MLQUEUE_DIS_FINISH ; +return SUCCESS ; }break ;case UNIT_ATTENTION :
@@ -573,14 +602,19 @@/* * Power On, Reset, or Bus Device Reset, just retry. */ -return SCSI_MLQUEUE_IMM_RETRY ; +return ADD_TO_MLQUEUE ; +if (sense_hdr->asc ==0x8b && sense_hdr->ascq ==0x02 ) +/* +* Quiescence in progress , just retry. +*/ +return ADD_TO_MLQUEUE ;break ; }/* success just means we do not care what scsi-ml does */ -return 0 ; +return SCSI_RETURN_NOT_HANDLED ; } -const struct scsi_dh_devlist rdac_dev_list[] = { +static const struct scsi_dh_devlist rdac_dev_list[] = { {"IBM" ,"1722" }, {"IBM" ,"1724" }, {"IBM" ,"1726" },
@@ -595,6 +629,10 @@ {"STK", "OPENstorage D280"}, {"SUN", "CSM200_R"}, {"SUN", "LCSM100_F"}, + {"DELL", "MD3000"}, + {"DELL", "MD3000i"}, + {"LSI", "INF-01-00"}, + {"ENGENIO", "INF-01-00"}, {NULL, NULL}, };
@@ -612,9 +650,6 @@ .activate = rdac_activate, }; -/* -* TODO: need some interface so we can set trespass values -*/ static int rdac_bus_attach (struct scsi_device *sdev) {struct scsi_dh_data *scsi_dh_data;
@@ -623,10 +658,11 @@int err; scsi_dh_data =kzalloc (sizeof (struct scsi_device_handler *) - +sizeof (*h) ,GFP_KERNEL ); + +sizeof (*h) ,GFP_KERNEL );if (!scsi_dh_data) { -sdev_printk (KERN_ERR , sdev,"%s: Attach failed\n" ,RDAC_NAME ); -return -ENOMEM ; +sdev_printk (KERN_ERR , sdev,"%s: Attach failed\n" , +RDAC_NAME ); +return 0 ; } scsi_dh_data->scsi_dh = &rdac_dh;
@@ -646,28 +682,31 @@ goto failed;spin_lock_irqsave (sdev->request_queue->queue_lock, flags); -store_scsi_dh_data (sdev, scsi_dh_data); + sdev->scsi_dh_data = scsi_dh_data;spin_unlock_irqrestore (sdev->request_queue->queue_lock, flags); -sdev_printk (KERN_NOTICE , sdev,"%s: LUN %d (%s)\n" , -RDAC_NAME , h->lun, lun_state[(int )h->lun_state]); +sdev_printk (KERN_NOTICE , sdev, +"%s: LUN %d (%s)\n" , +RDAC_NAME , h->lun, lun_state[(int )h->lun_state]); +return 0 ; failed:kfree (scsi_dh_data); -sdev_printk (KERN_ERR , sdev,"%s: not attached\n" ,RDAC_NAME ); +sdev_printk (KERN_ERR , sdev,"%s: not attached\n" , +RDAC_NAME );return -EINVAL ; } -static void rdac_bus_detach (struct scsi_device *sdev) +static void rdac_bus_detach (struct scsi_device *sdev ) {struct scsi_dh_data *scsi_dh_data;struct rdac_dh_data *h;unsigned long flags;spin_lock_irqsave (sdev->request_queue->queue_lock, flags); - scsi_dh_data =retrieve_scsi_dh_data (sdev); -store_scsi_dh_data (sdev,NULL ); + scsi_dh_data = sdev->scsi_dh_data; + sdev->scsi_dh_data =NULL ;spin_unlock_irqrestore (sdev->request_queue->queue_lock, flags); h = (struct rdac_dh_data *) scsi_dh_data->buf;
@@ -675,9 +714,11 @@kref_put (&h->ctlr->kref, release_controller);kfree (scsi_dh_data);module_put (THIS_MODULE ); -sdev_printk (KERN_NOTICE , sdev,"%s Dettached\n" ,RDAC_NAME ); +sdev_printk (KERN_NOTICE , sdev,"%s: Detached\n" ,RDAC_NAME ); } + +static int __init rdac_init (void ) {int r;
I try to keep the latest releases of RHEL and SLES by porting and test them.
These changes are ported to RHEL 5.4, and will be available.
Do you still want to know which of these you might need (for your system)
chandra
Quoted 330 lines · Charlie Brady
Quoted 4 lines · Chandra Seetharaman
Hopefully not :)... it has been fixed for a while.
Jacov, Can you send me the
scsi_dh_rdac.cfile. I want to make sure you are running the latest code.Jacov told us that he was running 2.6.18-128.4.1.el5xen, which certainly isn't the latest code. It's the latest Red Hat RHEL5 code (or rather, was until yesterday).
Below are the diffs from linus's git repo. I'd guess that there would be minor changes needed before the current code would compile and run with the RHEL5 kernel.
Chandra, can you spot any one or two patches that would be most important to back-port to RHEL5?
home/speech/bradyc/scsi_dh_rdac.c renamed from linux-2.6.18.i386/drivers/scsi/device_handler/scsi_dh_rdac.c +87
-48-0400 @@ -19,14 +19,12 @@* Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA. * */ -#include <linux/list.h> #include <scsi/scsi.h> #include <scsi/scsi_eh.h> -#include <scsi/scsi_cmnd.h> #include <scsi/scsi_dh.h> -#include "../scsi_priv.h" #define RDAC_NAME "rdac" +#define RDAC_RETRY_COUNT 5/* * LSI mode page stuff @@ -202,7 +200,7 @@static inline struct rdac_dh_data *get_rdac_data (struct scsi_device *sdev) { -struct scsi_dh_data *scsi_dh_data =retrieve_scsi_dh_data (sdev); +struct scsi_dh_data *scsi_dh_data = sdev->scsi_dh_data;BUG_ON (scsi_dh_data ==NULL );return ((struct rdac_dh_data *) scsi_dh_data->buf); }@@ -228,10 +226,9 @@return NULL ; } -memset (rq->cmd,0 ,BLK_MAX_CDB ); - - rq->flags |=REQ_FAILFAST_DEV |REQ_FAILFAST_TRANSPORT | -REQ_FAILFAST_DRIVER |REQ_NOMERGE |REQ_BLOCK_PC ; + rq->cmd_type =REQ_TYPE_BLOCK_PC ; + rq->cmd_flags |=REQ_FAILFAST_DEV |REQ_FAILFAST_TRANSPORT | +REQ_FAILFAST_DRIVER ; rq->retries =RDAC_RETRIES ; rq->timeout =RDAC_TIMEOUT ;@@ -390,6 +387,7 @@struct c9_inquiry *inqp; h->lun_state =RDAC_LUN_UNOWNED ; + h->state =RDAC_STATE_ACTIVE ; err =submit_inquiry (sdev,0xC9 ,sizeof (struct c9_inquiry ), h);if (err ==SCSI_DH_OK ) { inqp = &h->inq.c9;@@ -407,6 +405,7 @@if (h->lun_state ==RDAC_LUN_UNOWNED ) h->state =RDAC_STATE_PASSIVE ; +return err; }@@ -450,28 +449,40 @@ unsigned char *sensebuf) {struct scsi_sense_hdr sense_hdr; -int sense, err =SCSI_DH_IO , ret; +int err =SCSI_DH_IO , ret; ret =scsi_normalize_sense (sensebuf,SCSI_SENSE_BUFFERSIZE , &sense_hdr);if (!ret) goto done; err =SCSI_DH_OK ; - sense = (sense_hdr.sense_key <<16 ) | (sense_hdr.asc <<8 ) | - sense_hdr.ascq; -/* If it is retryable failure, submit the c9 inquiry again */ -if (sense ==0x59136 || sense ==0x68b02 || sense ==0xb8b02 || - sense ==0x62900 ) { -/* 0x59136 - Command lock contention -* 0x[6b]8b02 - Quiesense in progress or achieved -* 0x62900 - Power On, Reset, or Bus Device Reset -*/ + +switch (sense_hdr.sense_key) { +case NO_SENSE : +case ABORTED_COMMAND : +case UNIT_ATTENTION : err =SCSI_DH_RETRY ; +break ; +case NOT_READY : +if (sense_hdr.asc ==0x04 && sense_hdr.ascq ==0x01 ) +/* LUN Not Ready and is in the Process of Becoming +* Ready +*/ + err =SCSI_DH_RETRY ; +break ; +case ILLEGAL_REQUEST : +if (sense_hdr.asc ==0x91 && sense_hdr.ascq ==0x36 ) +/* +* Command Lock contention +*/ + err =SCSI_DH_RETRY ; +break ; +default : +sdev_printk (KERN_INFO , sdev, +"MODE_SELECT failed with sense %02x/%02x/%02x.\n" , + sense_hdr.sense_key, sense_hdr.asc, sense_hdr.ascq); } -if (sense) -sdev_printk (KERN_INFO , sdev, -"MODE_SELECT failed with sense 0x%x.\n" , sense); done:return err; }@@ -480,21 +491,27 @@ {struct request *rq;struct request_queue *q = sdev->request_queue; -int err =SCSI_DH_RES_TEMP_UNAVAIL ; +int err, retry_cnt =RDAC_RETRY_COUNT ; +retry: + err =SCSI_DH_RES_TEMP_UNAVAIL ; rq =rdac_failover_get (sdev, h);if (!rq) goto done; -sdev_printk (KERN_INFO , sdev,"queueing MODE_SELECT command.\n" ); +sdev_printk (KERN_INFO , sdev,"%s MODE_SELECT command.\n" , + (retry_cnt ==RDAC_RETRY_COUNT ) ?"queueing" :"retrying" ); err =blk_execute_rq (q,NULL , rq,1 ); -if (err !=SCSI_DH_OK ) +blk_put_request (rq); +if (err !=SCSI_DH_OK ) { err =mode_select_handle_sense (sdev, h->sense); +if (err ==SCSI_DH_RETRY && retry_cnt--) + goto retry; + }if (err ==SCSI_DH_OK ) h->state =RDAC_STATE_ACTIVE ; -blk_put_request (rq); done:return err; }@@ -532,7 +549,7 @@if (h->state !=RDAC_STATE_ACTIVE ) { ret =BLKPREP_KILL ; - req->flags |=REQ_QUIET ; + req->cmd_flags |=REQ_QUIET ; }return ret;@@ -544,19 +561,31 @@struct rdac_dh_data *h =get_rdac_data (sdev);switch (sense_hdr->sense_key) {case NOT_READY : +if (sense_hdr->asc ==0x04 && sense_hdr->ascq ==0x01 ) +/* LUN Not Ready - Logical Unit Not Ready and is in +* the process of becoming ready +* Just retry. +*/ +return ADD_TO_MLQUEUE ;if (sense_hdr->asc ==0x04 && sense_hdr->ascq ==0x81 )/* LUN Not Ready - Storage firmware incompatible * Manual code synchonisation required. * * Nothing we can do here. Try to bypass the path. */ -return SCSI_MLQUEUE_DIS_FINISH ; +return SUCCESS ;if (sense_hdr->asc ==0x04 && sense_hdr->ascq ==0xA1 )/* LUN Not Ready - Quiescense in progress * * Just retry and wait. */ -return SCSI_MLQUEUE_IMM_RETRY ; +return ADD_TO_MLQUEUE ; +if (sense_hdr->asc ==0xA1 && sense_hdr->ascq ==0x02 ) +/* LUN Not Ready - Quiescense in progress +* or has been achieved +* Just retry. +*/ +return ADD_TO_MLQUEUE ;break ;case ILLEGAL_REQUEST :if (sense_hdr->asc ==0x94 && sense_hdr->ascq ==0x01 ) {@@ -565,7 +594,7 @@* Fail the path, so that the other path be used. */ h->state =RDAC_STATE_PASSIVE ; -return SCSI_MLQUEUE_DIS_FINISH ; +return SUCCESS ; }break ;case UNIT_ATTENTION :@@ -573,14 +602,19 @@/* * Power On, Reset, or Bus Device Reset, just retry. */ -return SCSI_MLQUEUE_IMM_RETRY ; +return ADD_TO_MLQUEUE ; +if (sense_hdr->asc ==0x8b && sense_hdr->ascq ==0x02 ) +/* +* Quiescence in progress , just retry. +*/ +return ADD_TO_MLQUEUE ;break ; }/* success just means we do not care what scsi-ml does */ -return 0 ; +return SCSI_RETURN_NOT_HANDLED ; } -const struct scsi_dh_devlist rdac_dev_list[] = { +static const struct scsi_dh_devlist rdac_dev_list[] = { {"IBM" ,"1722" }, {"IBM" ,"1724" }, {"IBM" ,"1726" },@@ -595,6 +629,10 @@ {"STK", "OPENstorage D280"}, {"SUN", "CSM200_R"}, {"SUN", "LCSM100_F"}, + {"DELL", "MD3000"}, + {"DELL", "MD3000i"}, + {"LSI", "INF-01-00"}, + {"ENGENIO", "INF-01-00"}, {NULL, NULL}, };@@ -612,9 +650,6 @@ .activate = rdac_activate, }; -/* -* TODO: need some interface so we can set trespass values -*/ static int rdac_bus_attach (struct scsi_device *sdev) {struct scsi_dh_data *scsi_dh_data;@@ -623,10 +658,11 @@int err; scsi_dh_data =kzalloc (sizeof (struct scsi_device_handler *) - +sizeof (*h) ,GFP_KERNEL ); + +sizeof (*h) ,GFP_KERNEL );if (!scsi_dh_data) { -sdev_printk (KERN_ERR , sdev,"%s: Attach failed\n" ,RDAC_NAME ); -return -ENOMEM ; +sdev_printk (KERN_ERR , sdev,"%s: Attach failed\n" , +RDAC_NAME ); +return 0 ; } scsi_dh_data->scsi_dh = &rdac_dh;@@ -646,28 +682,31 @@ goto failed;spin_lock_irqsave (sdev->request_queue->queue_lock, flags); -store_scsi_dh_data (sdev, scsi_dh_data); + sdev->scsi_dh_data = scsi_dh_data;spin_unlock_irqrestore (sdev->request_queue->queue_lock, flags); -sdev_printk (KERN_NOTICE , sdev,"%s: LUN %d (%s)\n" , -RDAC_NAME , h->lun, lun_state[(int )h->lun_state]); +sdev_printk (KERN_NOTICE , sdev, +"%s: LUN %d (%s)\n" , +RDAC_NAME , h->lun, lun_state[(int )h->lun_state]); +return 0 ; failed:kfree (scsi_dh_data); -sdev_printk (KERN_ERR , sdev,"%s: not attached\n" ,RDAC_NAME ); +sdev_printk (KERN_ERR , sdev,"%s: not attached\n" , +RDAC_NAME );return -EINVAL ; } -static void rdac_bus_detach (struct scsi_device *sdev) +static void rdac_bus_detach (struct scsi_device *sdev ) {struct scsi_dh_data *scsi_dh_data;struct rdac_dh_data *h;unsigned long flags;spin_lock_irqsave (sdev->request_queue->queue_lock, flags); - scsi_dh_data =retrieve_scsi_dh_data (sdev); -store_scsi_dh_data (sdev,NULL ); + scsi_dh_data = sdev->scsi_dh_data; + sdev->scsi_dh_data =NULL ;spin_unlock_irqrestore (sdev->request_queue->queue_lock, flags); h = (struct rdac_dh_data *) scsi_dh_data->buf;@@ -675,9 +714,11 @@kref_put (&h->ctlr->kref, release_controller);kfree (scsi_dh_data);module_put (THIS_MODULE ); -sdev_printk (KERN_NOTICE , sdev,"%s Dettached\n" ,RDAC_NAME ); +sdev_printk (KERN_NOTICE , sdev,"%s: Detached\n" ,RDAC_NAME ); } + +static int __init rdac_init (void ) {int r; --dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Quoted 4 lines · Chandra Seetharaman
I try to keep the latest releases of RHEL and SLES by porting and test them.
These changes are ported to RHEL 5.4, and will be available.
They appear not to be in RHEL5.3. The only mention of rdac I see in the changelog of 2.6.18-128.4.1.el5 is this one:
* Fri Sep 12 2008 Don Zickus <[email protected]> [2.6.18-112.el5]
...
- [scsi] scsi_dh: add rdac handler ([email protected] ) [438761]
...
https://bugzilla.redhat.com/show_bug.cgi?id=438761
I did look at the RHEL 5.4 beta, and there are other updates mentioned in changelog there:
* Wed May 20 2009 Don Zickus <[email protected]> [2.6.18-150.el5]
...
- [scsi] Retry mode select in rdac device handler (Jesse Larrew ) [489582]
...
* Fri May 01 2009 Don Zickus <[email protected]> [2.6.18-143.el5]
...
- [scsi] add md3000 and md3000i entries to rdac_dev_list (John Feeney ) [487293]
...
https://bugzilla.redhat.com/show_bug.cgi?id=487293
Jacov, you might want to look at the above bugzilla. There is some discussion of failover behaviour which might be useful to you.
Quoted 1 line
Do you still want to know which of these you might need (for your system)
Yes I would. Or better, if you see any required patches which are not included in RHEL5.4, please let RedHat know (via Bugzilla). I will ask them to add support for the StorageTek 2510 and 2530 arrays.
---
Charlie
Quoted 13 lines · On Tue, 25 Aug 2009 16:51:34 -0400 (EDT) Charlie Brady…
I did look at the RHEL 5.4 beta, and there are other updates mentioned in changelog there:
* Wed May 20 2009 Don Zickus <[email protected]> [2.6.18-150.el5]
...
- [scsi] Retry mode select in rdac device handler (Jesse Larrew ) [489582] ...
* Fri May 01 2009 Don Zickus <[email protected]> [2.6.18-143.el5]
...
- [scsi] add md3000 and md3000i entries tordac_dev_list(John Feeney ) [487293]
...
Quoted 4 lines
https://bugzilla.redhat.com/show_bug.cgi?id=487293
Jacov, you might want to look at the above bugzilla. There is some discussion of failover behaviour which might be useful to you.
Thank you, I'll take a look...
OK, I've noticed the following:
Feb 25 11:29:55 rhel5r300 multipathd: 8:16: reinstated Feb 25 11:29:55 rhel5r300 multipathd: 8:32: reinstated Feb 25 11:29:55 rhel5r300 multipathd: 8:48: reinstated Feb 25 11:29:55 rhel5r300 multipathd: 8:64: reinstated
How often are these messages supposed to repeat? Because I've succeded with one combination of HostType in StorageTek 2530 configuration for initiators, and RDAC on the Linux side. But I had messages like these every few minutes in /var/log/messages.
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 7 lines · Chandra Seetharaman
I try to keep the latest releases of RHEL and SLES by porting and test them.
These changes are ported to RHEL 5.4, and will be available.
Do you still want to know which of these you might need (for your system)
I notice that this patch doesn't seem to have been merged by Red Hat:
http://kerneltrap.org/mailarchive/linux-scsi/2008/10/30/3873414
That's this one:
Quoted 8 lines
Quoted 8 lines
home/speech/bradyc/scsi_dh_rdac.c renamed from linux-2.6.18.i386/drivers/scsi/device_handler/scsi_dh_rdac.c +1
-0@@ -390,6 +387,7 @@struct c9_inquiry *inqp; h->lun_state =RDAC_LUN_UNOWNED ; + h->state =RDAC_STATE_ACTIVE ; err =submit_inquiry (sdev,0xC9 ,sizeof (struct c9_inquiry ), h);if (err ==SCSI_DH_OK ) { inqp = &h->inq.c9;
Quoted 6 lines · Charlie Brady
Quoted 3 lines · Chandra Seetharaman
I try to keep the latest releases of RHEL and SLES by porting and test them.
Quoted 8 lines
Quoted 4 lines
These changes are ported to RHEL 5.4, and will be available.
Do you still want to know which of these you might need (for your system)
I notice that this patch doesn't seem to have been merged by Red Hat:
http://kerneltrap.org/mailarchive/linux-scsi/2008/10/30/3873414
Hmm, I see it in my RHEL 5.4.
what is the RedHat kernel version you are looking at (in RHEL 5.4) ?
Quoted 12 lines
That's this one:
Quoted 8 lines
Quoted 8 lines
home/speech/bradyc/scsi_dh_rdac.c renamed from linux-2.6.18.i386/drivers/scsi/device_handler/scsi_dh_rdac.c +1
-0@@ -390,6 +387,7 @@struct c9_inquiry *inqp; h->lun_state =RDAC_LUN_UNOWNED ; + h->state =RDAC_STATE_ACTIVE ; err =submit_inquiry (sdev,0xC9 ,sizeof (struct c9_inquiry ), h);if (err ==SCSI_DH_OK ) { inqp = &h->inq.c9;
Quoted 7 lines · Chandra Seetharaman
Quoted 3 lines
I notice that this patch doesn't seem to have been merged by Red Hat:
http://kerneltrap.org/mailarchive/linux-scsi/2008/10/30/3873414
Hmm, I see it in my RHEL 5.4.
what is the RedHat kernel version you are looking at (in RHEL 5.4) ?
My mistake, sorry. I was looking at 5.3.
RHEL 5.4 does contain these:
[email protected] 20090514045648.10947.8280.sendpatchset@squad5-lp1.lab.bos.redhat.com
Quoted 6 lines · On Wed, 26 Aug 2009 19:01:36 -0400 (EDT) Charlie Brady…
My mistake, sorry. I was looking at 5.3.
RHEL 5.4 does contain these:
[email protected] 20090514045648.10947.8280.sendpatchset@squad5-lp1.lab.bos.redhat.com
Can I just try the multipath with kernel from 5.4 beta on 5.3? Is there a need to upgrade the device-mapper-multipath too, or are these kernel patches enough to test if this is going to work in my case?
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 11 lines · Jakov Sosic
Quoted 6 lines · On Wed, 26 Aug 2009 19:01:36 -0400 (EDT) Charlie Brady…
My mistake, sorry. I was looking at 5.3.
RHEL 5.4 does contain these:
[email protected] 20090514045648.10947.8280.sendpatchset@squad5-lp1.lab.bos.redhat.com
Can I just try the multipath with kernel from 5.4 beta on 5.3?
You can use the 5.4beta kernel with 5.3. However, that kernel does not contain support for the 2530 in the scsi_dh_rdac module. You would need to patch the module. However, I have a src rpm which updates just that module. I will send it to you, with rebuild instructions.
Quoted 1 line
Is there a need to upgrade the device-mapper-multipath too, or are these kernel patches enough to test if this is going to work in my case?
You don't need to upgrade device-mapper-multipath to include a default configuration for the 2530, but you would need to add a device stanza in multipath.conf. There might be other reasons to upgrade device-mapper-multipath to the RH5.4 version - I haven't checked the changelog.
---
Charlie
Quoted 5 lines · Jakov Sosic
Quoted 2 lines · On Wed, 26 Aug 2009 19:01:36 -0400 (EDT) Charlie Brady…
My mistake, sorry. I was looking at 5.3.
Quoted 8 lines
Quoted 4 lines
RHEL 5.4 does contain these:
[email protected] 20090514045648.10947.8280.sendpatchset@squad5-lp1.lab.bos.redhat.com
Can I just try the multipath with kernel from 5.4 beta on 5.3? Is there a need to upgrade the device-mapper-multipath too, or are these kernel patches enough to test if this is going to work in my case?
If it is a production system I would suggest you to update the tools also.
Quoted 2 lines
On Mon, 24 Aug 2009 13:57:31 -0700
Chandra Seetharaman <[email protected]> wrote:
Also from the dmesg - if it helps:
device-mapper: table: 253:0: multipath: error getting device
device-mapper: ioctl: error adding target to table
device-mapper: table: 253:0: multipath: error getting device
device-mapper: ioctl: error adding target to table
rdac: device handler registered
device-mapper: multipath: Using scsi_dh module scsi_dh_rdac for failover/failback and device management.
sd 1:0:1:0: rdac: LUN 0 (owned)
sd 1:0:0:0: rdac: LUN 0 (unowned)
device-mapper: multipath: Using scsi_dh module scsi_dh_rdac for failover/failback and device management.
sd 1:0:1:1: rdac: LUN 1 (owned)
sd 1:0:0:1: rdac: LUN 1 (unowned)
device-mapper: multipath: Using scsi_dh module scsi_dh_rdac for failover/failback and device management.
sd 1:0:0:2: rdac: LUN 2 (owned)
sd 1:0:1:2: rdac: LUN 2 (unowned)
Signature · 3 lines
| Jakov Sosic | ICQ: 28410271 | PGP: 0x965CAE2D | ================================================================= | start fighting cancer -> http://www.worldcommunitygrid.org/ |
Quoted 10 lines · Jakov Sosic
On Mon, 24 Aug 2009 13:57:31 -0700
Chandra Seetharaman <[email protected]> wrote:Also from the dmesg - if it helps:
device-mapper: table: 253:0: multipath: error getting device
device-mapper: ioctl: error adding target to table
device-mapper: table: 253:0: multipath: error getting device
device-mapper: ioctl: error adding target to table
Above message is most likely from your root disk (it is a scsi disk, right ?).
You can avoid getting this by adding a blacklist in your multipath.conf file.
Quoted 5 lines
rdac: device handler registered
device-mapper: multipath: Usingscsi_dhmodulescsi_dh_rdacfor failover/failback and device management.
sd 1:0:1:0: rdac: LUN 0 (owned)
sd 1:0:0:0: rdac: LUN 0 (unowned)
Quoted 8 lines
device-mapper: multipath: Using
scsi_dhmodulescsi_dh_rdacfor failover/failback and device management.
sd 1:0:1:1: rdac: LUN 1 (owned)
sd 1:0:0:1: rdac: LUN 1 (unowned)
device-mapper: multipath: Usingscsi_dhmodulescsi_dh_rdacfor failover/failback and device management.
sd 1:0:0:2: rdac: LUN 2 (owned)
sd 1:0:1:2: rdac: LUN 2 (unowned)
These are good.