Hello list,

I'm having a strange error condition I'm hoping someone here might be able to help me get to the bottom of. I've got a HP blade enclosure with a Nortel switch module, and one of the blades are running VMWare ESX. When I turn on this blade (or enable its switch port), the entire network stops working after a short while. Other server blades can no longer communicate, for instance. The only clue I've found so far is the following error message from one of the other blades that's running CentOS 5.4:

[bnx2x_hw_stats_update:3701(eth0)]NIG timer max (426)

The line is logged every two seconds and the number in parenthesis is incrementing each time. Once I disable the port to the ESX server, the network instantly recovers.

I have no reason to believe the Linux kernel/bnx2x is doing anything wrong here, but I'm wondering if anybody has any idea on what this error message means and what could be causing it? I can't see anything unusual going on with tcpdump, and the error counters in "ip -s -s link show eth0" are all zero.

Best regards,

Signature · 3 lines
Tore Anderson
Redpill Linpro AS - http://www.redpill-linpro.com/
Tel: +47 21 54 41 27
#1 lore raw
Quoted 17 lines · Tore Anderson

Hello list,

I'm having a strange error condition I'm hoping someone here might be able to help me get to the bottom of. I've got a HP blade enclosure with a Nortel switch module, and one of the blades are running VMWare ESX. When I turn on this blade (or enable its switch port), the entire network stops working after a short while. Other server blades can no longer communicate, for instance. The only clue I've found so far is the following error message from one of the other blades that's running CentOS 5.4:

[bnx2x_hw_stats_update:3701(eth0)]NIG timer max (426)

The line is logged every two seconds and the number in parenthesis is incrementing each time. Once I disable the port to the ESX server, the network instantly recovers.

Quoted 5 lines

I have no reason to believe the Linux kernel/bnx2x is doing anything wrong here, but I'm wondering if anybody has any idea on what this error message means and what could be causing it? I can't see anything unusual going on with tcpdump, and the error counters in "ip -s -s link show eth0" are all zero.

This message indicates that for over 1 second, the device could not transmit anything to the network (the same packet was not transmitted for over one second) - this usually happens when the network is in fatal condition - usually because some device is sending constant pause stream that halts all traffic. In this case, the device is incrementing the counter and drains outgoing traffic - without this action, the device will not be able to unload since even the commands from the driver will not be processed due to this excessive back pressure.

As you indicated - once you remove the server that halts all other traffic, everything else resumes - that indicates that this server is sending constant pause that ultimately halts the entire switch.

Regards,
Eilon

#2 lore raw

* Eilon Greenstein

Quoted 10 lines

This message indicates that for over 1 second, the device could not transmit anything to the network (the same packet was not transmitted for over one second) - this usually happens when the network is in fatal condition - usually because some device is sending constant pause stream that halts all traffic. In this case, the device is incrementing the counter and drains outgoing traffic - without this action, the device will not be able to unload since even the commands from the driver will not be processed due to this excessive back pressure.

Quoted 3 lines

As you indicated - once you remove the server that halts all other traffic, everything else resumes - that indicates that this server is sending constant pause that ultimately halts the entire switch.

Thank you very much for your input Elion, you've definetively helped me look in the right place. I do see a constant stream of pause frames being sent by the switch module to a F5 BIG-IP box that's connected to external ports of the switch. The stream appears instantly when the ESX server is connected and vanishes just as fast when it's been disconnected. I haven't been able to verify what the ESX server is doing to the switch yet, but your assumption that it too is spewing out pause frames sounds very likely to me.

However I'm still a bit confused on why this is triggering the "NIG timer max" message on the Linux blade. It would have made perfect sense to me for the bnx2x driver/NIC to stop transmitting outbound frames if it was the recipient of an inbound pause frame flood, but tcpdump does not show any such frames being received. Yet it stalls all outbound traffic. Any idea why?

Best regards,

Signature · 3 lines
Tore Anderson
Redpill Linpro AS - http://www.redpill-linpro.com/
Tel: +47 21 54 41 27
#3 lore raw
Quoted 7 lines · Tore Anderson

However I'm still a bit confused on why this is triggering the "NIG timer max" message on the Linux blade. It would have made perfect sense to me for the bnx2x driver/NIC to stop transmitting outbound frames if it was the recipient of an inbound pause frame flood, but tcpdump does not show any such frames being received. Yet it stalls all outbound traffic. Any idea why?

The pause frames are processed in the HW and therefore not visible to tcpdump. You should be able to see the pause counter increases in "ethtool -S".

Regards,