staging: comedi: fix signess bug
Subsystems (2)
PATCH 1/1 staging: comedi: fix signess bug
ai_count and ao_counter are unsigned, check for < 0 doesn't make sense. Cast them to int.
Signed-off-by Vasiliy Kulikov <[email protected]>
---
Compile tested.
drivers/staging/comedi/drivers/cb_pcidas64.c | 2 +- drivers/staging/comedi/drivers/usbdux.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)
drivers/staging/comedi/drivers/cb_pcidas64.c +1 -1
@@ -3078,7 +3078,7 @@ static void handle_ai_interrupt(struct comedi_device *dev,spin_unlock_irqrestore (&dev->spinlock, flags); }/* if we are have all the data, then quit */ -if ((cmd->stop_src =TRIG_COUNT &&priv (dev)->ai_count <=0 ) || +if ((cmd->stop_src =TRIG_COUNT && (int )priv (dev)->ai_count <=0 ) || (cmd->stop_src =TRIG_EXT && (status &ADC_STOP_BIT ))) { async->events |=COMEDI_CB_EOA ; }
drivers/staging/comedi/drivers/usbdux.c +1 -1
@@ -649,7 +649,7 @@ static void usbduxsub_ao_IsocIrq(struct urb *urb)/* normal operation: executing a command in this subdevice */ this_usbduxsub->ao_counter--; -if (this_usbduxsub->ao_counter <=0 ) { +if ((int )this_usbduxsub->ao_counter <=0 ) {/* timer zero */ this_usbduxsub->ao_counter = this_usbduxsub->ao_timer;
Signature · 1 line
1.7.0.4