rteval: Add measurement and load location to run report

PATCH Superseded Leah Leshchinsky 2 participants 6 messages Aug 4, 2022 – Aug 5, 2022

v2 of 4 Superseded Latest is v4 →

lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 rteval: Add measurement and load location to run report

The run report produced at the end of a run does not contain information on load and measurement thread locations.

Adjust MakeReport() functions of LoadModules and MeasurementModules class so that new properties with number of loads and cpu information are added to the XML report and can be read by rteval_text.xsl.

rteval/modules/loads/__init__.py +7 -0
index 2c2105efa964..5e5a5d85b616 100644
@@ -30,6 +30,7 @@ import libxml2
 from rteval.Log import Log
 from rteval.rtevalConfig import rtevalCfgSection
 from rteval.modules import RtEvalModules, rtevalModulePrototype
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class LoadThread(rtevalModulePrototype):
     def __init__(self, name, config, logger=None):
@@ -131,6 +132,12 @@ class LoadModules(RtEvalModules):
     def MakeReport(self):
         rep_n = RtEvalModules.MakeReport(self)
         rep_n.newProp("load_average", str(self.GetLoadAvg()))
+        rep_n.newProp("loads", str(self.ModulesLoaded()))
+        cpulist = self._cfg.GetSection(self._module_config).cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("loadcpus", cpulist)
 
         return rep_n
 
rteval/modules/measurement/__init__.py +7 -1
index 318248bd7e35..371fc5d08f44 100644
@@ -24,7 +24,7 @@
 
 import libxml2
 from rteval.modules import RtEvalModules, ModuleContainer
-
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class MeasurementProfile(RtEvalModules):
     """Keeps and controls all the measurement modules with the same measurement profile"""
@@ -189,6 +189,12 @@ measurement profiles, based on their characteristics"""
 
         # Get the reports from all meaurement modules in all measurement profiles
         rep_n = libxml2.newNode("Measurements")
+        cpulist = self.__cfg.GetSection("measurement").cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("measurecpus", cpulist)
+
         for mp in self.__measureprofiles:
             mprep_n = mp.MakeReport()
             if mprep_n:
rteval/rteval_text.xsl +8 -0
index c40063e3dd19..7ecfac6b6140 100644
@@ -13,6 +13,14 @@
     <xsl:value-of select="run_info/date"/><xsl:text> </xsl:text><xsl:value-of select="run_info/time"/>
     <xsl:text>&#10;</xsl:text>
 
+    <xsl:text>   Loads:        </xsl:text>
+    <xsl:value-of select="loads/@loads"/><xsl:text> loads run on cores </xsl:text><xsl:value-of select="loads/@loadcpus"/>
+    <xsl:text>&#10;</xsl:text>
+
+    <xsl:text>   Measurement:  </xsl:text>
+    <xsl:text>measurement threads run on cores </xsl:text><xsl:value-of select="Measurements/@measurecpus"/>
+    <xsl:text>&#10;</xsl:text>
+
     <xsl:text>   Run time:     </xsl:text>
     <xsl:value-of select="run_info/@days"/><xsl:text> days </xsl:text>
     <xsl:value-of select="run_info/@hours"/><xsl:text>h </xsl:text>
Signature · 1 line
2.31.1
#1 lore raw
Quoted 14 lines · Leah Leshchinsky

The run report produced at the end of a run does not contain information on load and measurement thread locations.

Adjust MakeReport() functions of LoadModules and MeasurementModules class so that new properties with number of loads and cpu information are added to the XML report and can be read by rteval_text.xsl.

rteval/modules/loads/__init__.py +0 -0
index 2c2105efa964..5e5a5d85b616 100644

rteval/modules/loads/__init__.py import libxml2 · line 33

Quoted 4 lines
rteval/modules/loads/__init__.py +1 -0
@@ -30,6 +30,7 @@ import libxml2
 from rteval.Log import Log
 from rteval.rtevalConfig import rtevalCfgSection
 from rteval.modules import RtEvalModules, rtevalModulePrototype
+from rteval.systopology import collapse_cpulist, SysTopology

add CpuList, and you might not need collapse_cpulist, and SysTopology

rteval/modules/loads/__init__.py class LoadModules(RtEvalModules): · line 136

Quoted 9 lines
rteval/modules/loads/__init__.py +2 -0
 class LoadThread(rtevalModulePrototype):
     def __init__(self, name, config, logger=None):
@@ -131,6 +132,12 @@ class LoadModules(RtEvalModules):
     def MakeReport(self):
         rep_n = RtEvalModules.MakeReport(self)
         rep_n.newProp("load_average", str(self.GetLoadAvg()))
+        rep_n.newProp("loads", str(self.ModulesLoaded()))
+        cpulist = self._cfg.GetSection(self._module_config).cpulist

The above value is either going to be all cpus, or the value of --loads-cpulist=LIST or the inverse of --measurement-cpulist=LIST I don't think it can be empty, so the following code after if not cpulist is deadcode

rteval/modules/loads/__init__.py class LoadModules(RtEvalModules): · line 139

Quoted 3 lines
rteval/modules/loads/__init__.py +3 -0
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())

If the above code were to run it would just be a list of all online cpus

Admitedly the systopology api is a bit confusing but since it does a lot, I think all you really need is
cpulist = CpuList(self._cfg.GetSection(self._module_config).cpulist)
rep_n.newProp("loadcpus", str(cpulist))

And that's it. You need to do something similar to the measurement section too.

Quoted 53 lines
rteval/modules/loads/__init__.py +1 -0
+        rep_n.newProp("loadcpus", cpulist)
 
         return rep_n
 
rteval/modules/measurement/__init__.py +7 -1
index 318248bd7e35..371fc5d08f44 100644
@@ -24,7 +24,7 @@
 
 import libxml2
 from rteval.modules import RtEvalModules, ModuleContainer
-
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class MeasurementProfile(RtEvalModules):
     """Keeps and controls all the measurement modules with the same measurement profile"""
@@ -189,6 +189,12 @@ measurement profiles, based on their characteristics"""
 
         # Get the reports from all meaurement modules in all measurement profiles
         rep_n = libxml2.newNode("Measurements")
+        cpulist = self.__cfg.GetSection("measurement").cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("measurecpus", cpulist)
+
         for mp in self.__measureprofiles:
             mprep_n = mp.MakeReport()
             if mprep_n:
rteval/rteval_text.xsl +8 -0
index c40063e3dd19..7ecfac6b6140 100644
@@ -13,6 +13,14 @@
     <xsl:value-of select="run_info/date"/><xsl:text> </xsl:text><xsl:value-of select="run_info/time"/>
     <xsl:text>&#10;</xsl:text>
 
+    <xsl:text>   Loads:        </xsl:text>
+    <xsl:value-of select="loads/@loads"/><xsl:text> loads run on cores </xsl:text><xsl:value-of select="loads/@loadcpus"/>
+    <xsl:text>&#10;</xsl:text>
+
+    <xsl:text>   Measurement:  </xsl:text>
+    <xsl:text>measurement threads run on cores </xsl:text><xsl:value-of select="Measurements/@measurecpus"/>
+    <xsl:text>&#10;</xsl:text>
+
     <xsl:text>   Run time:     </xsl:text>
     <xsl:value-of select="run_info/@days"/><xsl:text> days </xsl:text>
     <xsl:value-of select="run_info/@hours"/><xsl:text>h </xsl:text>
Signature · 1 line
2.31.1

Something in the xsl code is not working, I'm not picking up any values in the reports for "Measurements/@measurecpus" for example.

Thanks

#2 lore raw
In reply to Leah Leshchinsky
Quoted 82 lines · Leah Leshchinsky

The run report produced at the end of a run does not contain information on load and measurement thread locations.

Adjust MakeReport() functions of LoadModules and MeasurementModules class so that new properties with number of loads and cpu information are added to the XML report and can be read by rteval_text.xsl.

rteval/modules/loads/__init__.py +7 -0
index 2c2105efa964..5e5a5d85b616 100644
@@ -30,6 +30,7 @@ import libxml2
 from rteval.Log import Log
 from rteval.rtevalConfig import rtevalCfgSection
 from rteval.modules import RtEvalModules, rtevalModulePrototype
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class LoadThread(rtevalModulePrototype):
     def __init__(self, name, config, logger=None):
@@ -131,6 +132,12 @@ class LoadModules(RtEvalModules):
     def MakeReport(self):
         rep_n = RtEvalModules.MakeReport(self)
         rep_n.newProp("load_average", str(self.GetLoadAvg()))
+        rep_n.newProp("loads", str(self.ModulesLoaded()))
+        cpulist = self._cfg.GetSection(self._module_config).cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("loadcpus", cpulist)
 
         return rep_n
 
rteval/modules/measurement/__init__.py +7 -1
index 318248bd7e35..371fc5d08f44 100644
@@ -24,7 +24,7 @@
 
 import libxml2
 from rteval.modules import RtEvalModules, ModuleContainer
-
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class MeasurementProfile(RtEvalModules):
     """Keeps and controls all the measurement modules with the same measurement profile"""
@@ -189,6 +189,12 @@ measurement profiles, based on their characteristics"""
 
         # Get the reports from all meaurement modules in all measurement profiles
         rep_n = libxml2.newNode("Measurements")
+        cpulist = self.__cfg.GetSection("measurement").cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("measurecpus", cpulist)
+
         for mp in self.__measureprofiles:
             mprep_n = mp.MakeReport()
             if mprep_n:
rteval/rteval_text.xsl +8 -0
index c40063e3dd19..7ecfac6b6140 100644
@@ -13,6 +13,14 @@
     <xsl:value-of select="run_info/date"/><xsl:text> </xsl:text><xsl:value-of select="run_info/time"/>
     <xsl:text>&#10;</xsl:text>
 
+    <xsl:text>   Loads:        </xsl:text>
+    <xsl:value-of select="loads/@loads"/><xsl:text> loads run on cores </xsl:text><xsl:value-of select="loads/@loadcpus"/>
+    <xsl:text>&#10;</xsl:text>
+
+    <xsl:text>   Measurement:  </xsl:text>
+    <xsl:text>measurement threads run on cores </xsl:text><xsl:value-of select="Measurements/@measurecpus"/>
+    <xsl:text>&#10;</xsl:text>
+
     <xsl:text>   Run time:     </xsl:text>
     <xsl:value-of select="run_info/@days"/><xsl:text> days </xsl:text>
     <xsl:value-of select="run_info/@hours"/><xsl:text>h </xsl:text>
Signature · 1 line
2.31.1

Hi John,

I do believe the cpulist variable can be empty. I was able to test this by running rteval without specifying and load and measurement cpus.

This patch is attempting to replicate the behavior found in rteval/__init.py lines 187-201, which also finds the cpulist using
cpulist = self._loadmods._cfg.GetSection("loads").cpulist
and if the cpulist is empty, defaults to reporting the online cpus. I assume this is because the rteval program uses all available cpus to run measurement and load threads if no specific cpus are specified.

Please let me know if I am misunderstanding any of the above.

I will investigate why the xsl code is not working for you. It seems to be working for me at the moment.

Thank you for the review,
Leah

#3 lore raw
Quoted 86 lines · Leah Leshchinsky
Quoted 82 lines · Leah Leshchinsky

The run report produced at the end of a run does not contain information on load and measurement thread locations.

Adjust MakeReport() functions of LoadModules and MeasurementModules class so that new properties with number of loads and cpu information are added to the XML report and can be read by rteval_text.xsl.

rteval/modules/loads/__init__.py +7 -0
index 2c2105efa964..5e5a5d85b616 100644
@@ -30,6 +30,7 @@ import libxml2
 from rteval.Log import Log
 from rteval.rtevalConfig import rtevalCfgSection
 from rteval.modules import RtEvalModules, rtevalModulePrototype
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class LoadThread(rtevalModulePrototype):
     def __init__(self, name, config, logger=None):
@@ -131,6 +132,12 @@ class LoadModules(RtEvalModules):
     def MakeReport(self):
         rep_n = RtEvalModules.MakeReport(self)
         rep_n.newProp("load_average", str(self.GetLoadAvg()))
+        rep_n.newProp("loads", str(self.ModulesLoaded()))
+        cpulist = self._cfg.GetSection(self._module_config).cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("loadcpus", cpulist)
 
         return rep_n
 
rteval/modules/measurement/__init__.py +7 -1
index 318248bd7e35..371fc5d08f44 100644
@@ -24,7 +24,7 @@
 
 import libxml2
 from rteval.modules import RtEvalModules, ModuleContainer
-
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class MeasurementProfile(RtEvalModules):
     """Keeps and controls all the measurement modules with the same measurement profile"""
@@ -189,6 +189,12 @@ measurement profiles, based on their characteristics"""
 
         # Get the reports from all meaurement modules in all measurement profiles
         rep_n = libxml2.newNode("Measurements")
+        cpulist = self.__cfg.GetSection("measurement").cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("measurecpus", cpulist)
+
         for mp in self.__measureprofiles:
             mprep_n = mp.MakeReport()
             if mprep_n:
rteval/rteval_text.xsl +8 -0
index c40063e3dd19..7ecfac6b6140 100644
@@ -13,6 +13,14 @@
     <xsl:value-of select="run_info/date"/><xsl:text> </xsl:text><xsl:value-of select="run_info/time"/>
     <xsl:text>&#10;</xsl:text>
 
+    <xsl:text>   Loads:        </xsl:text>
+    <xsl:value-of select="loads/@loads"/><xsl:text> loads run on cores </xsl:text><xsl:value-of select="loads/@loadcpus"/>
+    <xsl:text>&#10;</xsl:text>
+
+    <xsl:text>   Measurement:  </xsl:text>
+    <xsl:text>measurement threads run on cores </xsl:text><xsl:value-of select="Measurements/@measurecpus"/>
+    <xsl:text>&#10;</xsl:text>
+
     <xsl:text>   Run time:     </xsl:text>
     <xsl:value-of select="run_info/@days"/><xsl:text> days </xsl:text>
     <xsl:value-of select="run_info/@hours"/><xsl:text>h </xsl:text>
Signature · 1 line
2.31.1

Hi John,

Quoted 1 line

I do believe the cpulist variable can be empty. I was able to test this by running rteval without specifying and load and measurement cpus.

Ok, you are correct, cpulist can be empty if the following are not set --loads-cpulist=LIST
--measurement-cpulist=LIST

So you do need some code to initialize the list of it is empty. But there are still problems

For example if you shut off cpu 3
su -c 'echo 0 > /sys/devices/system/cpu/cpu3/online '

And then request measurement on cpus 0-5
su -c './rteval-cmd -d5s --measurement-cpulist=0-5'

The report should say

Measurement:  measurement threads run on cores  0-2,4,5
Loads:        3 loads run on cores 6-11 (the inverse)
but instead with your patch it says
Loads:        3 loads run on cores 1,2,4,6,7,8,9,10,11
Measurement:  measurement threads run on cores 0-5

Now there are problems that exist even before your patch, so for example, the initial info to the screen not included in the report doesn't consider offline cpus. (We should fix that too of course, but we can do this stepwise)

And it's also possible that I have introduced some new problems with the changes to systopology that will hopefully make things simpler in the long run but may be interferring with your code. So, there are many things to untangle here.

Quoted 6 lines

This patch is attempting to replicate the behavior found in rteval/__init.py lines 187-201, which also finds the cpulist using
cpulist = self._loadmods._cfg.GetSection("loads").cpulist
and if the cpulist is empty, defaults to reporting the online cpus. I assume this is because the rteval program uses all available cpus to run measurement and load threads if no specific cpus are specified.

Quoted 10 lines

Please let me know if I am misunderstanding any of the above.

I will investigate why the xsl code is not working for you. It seems to be working for me at the moment.

Thank you for the review,
Leah

Thanks Leah

John

#4 lore raw
Quoted 134 lines · John Kacur
Quoted 86 lines · Leah Leshchinsky
Quoted 82 lines · Leah Leshchinsky

The run report produced at the end of a run does not contain information on load and measurement thread locations.

Adjust MakeReport() functions of LoadModules and MeasurementModules class so that new properties with number of loads and cpu information are added to the XML report and can be read by rteval_text.xsl.

rteval/modules/loads/__init__.py +7 -0
index 2c2105efa964..5e5a5d85b616 100644
@@ -30,6 +30,7 @@ import libxml2
 from rteval.Log import Log
 from rteval.rtevalConfig import rtevalCfgSection
 from rteval.modules import RtEvalModules, rtevalModulePrototype
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class LoadThread(rtevalModulePrototype):
     def __init__(self, name, config, logger=None):
@@ -131,6 +132,12 @@ class LoadModules(RtEvalModules):
     def MakeReport(self):
         rep_n = RtEvalModules.MakeReport(self)
         rep_n.newProp("load_average", str(self.GetLoadAvg()))
+        rep_n.newProp("loads", str(self.ModulesLoaded()))
+        cpulist = self._cfg.GetSection(self._module_config).cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("loadcpus", cpulist)
 
         return rep_n
 
rteval/modules/measurement/__init__.py +7 -1
index 318248bd7e35..371fc5d08f44 100644
@@ -24,7 +24,7 @@
 
 import libxml2
 from rteval.modules import RtEvalModules, ModuleContainer
-
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class MeasurementProfile(RtEvalModules):
     """Keeps and controls all the measurement modules with the same measurement profile"""
@@ -189,6 +189,12 @@ measurement profiles, based on their characteristics"""
 
         # Get the reports from all meaurement modules in all measurement profiles
         rep_n = libxml2.newNode("Measurements")
+        cpulist = self.__cfg.GetSection("measurement").cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("measurecpus", cpulist)
+
         for mp in self.__measureprofiles:
             mprep_n = mp.MakeReport()
             if mprep_n:
rteval/rteval_text.xsl +8 -0
index c40063e3dd19..7ecfac6b6140 100644
@@ -13,6 +13,14 @@
     <xsl:value-of select="run_info/date"/><xsl:text> </xsl:text><xsl:value-of select="run_info/time"/>
     <xsl:text>&#10;</xsl:text>
 
+    <xsl:text>   Loads:        </xsl:text>
+    <xsl:value-of select="loads/@loads"/><xsl:text> loads run on cores </xsl:text><xsl:value-of select="loads/@loadcpus"/>
+    <xsl:text>&#10;</xsl:text>
+
+    <xsl:text>   Measurement:  </xsl:text>
+    <xsl:text>measurement threads run on cores </xsl:text><xsl:value-of select="Measurements/@measurecpus"/>
+    <xsl:text>&#10;</xsl:text>
+
     <xsl:text>   Run time:     </xsl:text>
     <xsl:value-of select="run_info/@days"/><xsl:text> days </xsl:text>
     <xsl:value-of select="run_info/@hours"/><xsl:text>h </xsl:text>
Signature · 1 line
2.31.1

Hi John,

Quoted 1 line

I do believe the cpulist variable can be empty. I was able to test this by running rteval without specifying and load and measurement cpus.

Ok, you are correct, cpulist can be empty if the following are not set --loads-cpulist=LIST
--measurement-cpulist=LIST

So you do need some code to initialize the list of it is empty. But there are still problems

For example if you shut off cpu 3
su -c 'echo 0 > /sys/devices/system/cpu/cpu3/online '

And then request measurement on cpus 0-5
su -c './rteval-cmd -d5s --measurement-cpulist=0-5'

The report should say

Measurement:  measurement threads run on cores  0-2,4,5
Loads:        3 loads run on cores 6-11 (the inverse)
but instead with your patch it says
Loads:        3 loads run on cores 1,2,4,6,7,8,9,10,11
Measurement:  measurement threads run on cores 0-5

Now there are problems that exist even before your patch, so for example, the initial info to the screen not included in the report doesn't consider offline cpus. (We should fix that too of course, but we can do this stepwise)

And it's also possible that I have introduced some new problems with the changes to systopology that will hopefully make things simpler in the long run but may be interferring with your code. So, there are many things to untangle here.

Quoted 12 lines

This patch is attempting to replicate the behavior found in rteval/__init.py lines 187-201, which also finds the cpulist using
cpulist = self._loadmods._cfg.GetSection("loads").cpulist
and if the cpulist is empty, defaults to reporting the online cpus. I assume this is because the rteval program uses all available cpus to run measurement and load threads if no specific cpus are specified.

Please let me know if I am misunderstanding any of the above.

I will investigate why the xsl code is not working for you. It seems to be working for me at the moment.

Quoted 8 lines
Quoted 4 lines

Thank you for the review,
Leah

Thanks Leah

John

Hi John,

Quoted 6 lines

The report should say

Measurement:  measurement threads run on cores  0-2,4,5
Loads:        3 loads run on cores 6-11 (the inverse)
but instead with your patch it says
Loads:        3 loads run on cores 1,2,4,6,7,8,9,10,11
Measurement:  measurement threads run on cores 0-5

Now that I'm looking at the rteval program prior to my changes, I see that this issue existed in the initial pre-report posted to stdout. This seems to be a separate bug in the way that 'self._loadmods._cfg.GetSection("loads").cpulist' and self.__cfg.GetSection("measurement").cpulist are calculated.

When I test your example on the rteval main branch, this is the result:

su -c 'echo 0 > /sys/devices/system/cpu/cpu3/online ' su -c './rteval-cmd -d5s --measurement-cpulist=0-5'

started 3 loads on cores 1,2,4,6,7
started measurement threads on cores 0-5

Should we file this as a separate bug, since the scope of it goes beyond my current patch?

Thanks,
Leah

#5 lore raw
Quoted 161 lines · Leah Leshchinsky
Quoted 134 lines · John Kacur
Quoted 86 lines · Leah Leshchinsky
Quoted 82 lines · Leah Leshchinsky

The run report produced at the end of a run does not contain information on load and measurement thread locations.

Adjust MakeReport() functions of LoadModules and MeasurementModules class so that new properties with number of loads and cpu information are added to the XML report and can be read by rteval_text.xsl.

rteval/modules/loads/__init__.py +7 -0
index 2c2105efa964..5e5a5d85b616 100644
@@ -30,6 +30,7 @@ import libxml2
 from rteval.Log import Log
 from rteval.rtevalConfig import rtevalCfgSection
 from rteval.modules import RtEvalModules, rtevalModulePrototype
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class LoadThread(rtevalModulePrototype):
     def __init__(self, name, config, logger=None):
@@ -131,6 +132,12 @@ class LoadModules(RtEvalModules):
     def MakeReport(self):
         rep_n = RtEvalModules.MakeReport(self)
         rep_n.newProp("load_average", str(self.GetLoadAvg()))
+        rep_n.newProp("loads", str(self.ModulesLoaded()))
+        cpulist = self._cfg.GetSection(self._module_config).cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("loadcpus", cpulist)
 
         return rep_n
 
rteval/modules/measurement/__init__.py +7 -1
index 318248bd7e35..371fc5d08f44 100644
@@ -24,7 +24,7 @@
 
 import libxml2
 from rteval.modules import RtEvalModules, ModuleContainer
-
+from rteval.systopology import collapse_cpulist, SysTopology
 
 class MeasurementProfile(RtEvalModules):
     """Keeps and controls all the measurement modules with the same measurement profile"""
@@ -189,6 +189,12 @@ measurement profiles, based on their characteristics"""
 
         # Get the reports from all meaurement modules in all measurement profiles
         rep_n = libxml2.newNode("Measurements")
+        cpulist = self.__cfg.GetSection("measurement").cpulist
+        if not cpulist:
+            st = SysTopology()
+            cpulist = collapse_cpulist(st.online_cpus())
+        rep_n.newProp("measurecpus", cpulist)
+
         for mp in self.__measureprofiles:
             mprep_n = mp.MakeReport()
             if mprep_n:
rteval/rteval_text.xsl +8 -0
index c40063e3dd19..7ecfac6b6140 100644
@@ -13,6 +13,14 @@
     <xsl:value-of select="run_info/date"/><xsl:text> </xsl:text><xsl:value-of select="run_info/time"/>
     <xsl:text>&#10;</xsl:text>
 
+    <xsl:text>   Loads:        </xsl:text>
+    <xsl:value-of select="loads/@loads"/><xsl:text> loads run on cores </xsl:text><xsl:value-of select="loads/@loadcpus"/>
+    <xsl:text>&#10;</xsl:text>
+
+    <xsl:text>   Measurement:  </xsl:text>
+    <xsl:text>measurement threads run on cores </xsl:text><xsl:value-of select="Measurements/@measurecpus"/>
+    <xsl:text>&#10;</xsl:text>
+
     <xsl:text>   Run time:     </xsl:text>
     <xsl:value-of select="run_info/@days"/><xsl:text> days </xsl:text>
     <xsl:value-of select="run_info/@hours"/><xsl:text>h </xsl:text>
Signature · 1 line
2.31.1

Hi John,

Quoted 1 line

I do believe the cpulist variable can be empty. I was able to test this by running rteval without specifying and load and measurement cpus.

Ok, you are correct, cpulist can be empty if the following are not set --loads-cpulist=LIST
--measurement-cpulist=LIST

So you do need some code to initialize the list of it is empty. But there are still problems

For example if you shut off cpu 3
su -c 'echo 0 > /sys/devices/system/cpu/cpu3/online '

And then request measurement on cpus 0-5
su -c './rteval-cmd -d5s --measurement-cpulist=0-5'

The report should say

Measurement:  measurement threads run on cores  0-2,4,5
Loads:        3 loads run on cores 6-11 (the inverse)
but instead with your patch it says
Loads:        3 loads run on cores 1,2,4,6,7,8,9,10,11
Measurement:  measurement threads run on cores 0-5

Now there are problems that exist even before your patch, so for example, the initial info to the screen not included in the report doesn't consider offline cpus. (We should fix that too of course, but we can do this stepwise)

And it's also possible that I have introduced some new problems with the changes to systopology that will hopefully make things simpler in the long run but may be interferring with your code. So, there are many things to untangle here.

Quoted 12 lines

This patch is attempting to replicate the behavior found in rteval/__init.py lines 187-201, which also finds the cpulist using
cpulist = self._loadmods._cfg.GetSection("loads").cpulist
and if the cpulist is empty, defaults to reporting the online cpus. I assume this is because the rteval program uses all available cpus to run measurement and load threads if no specific cpus are specified.

Please let me know if I am misunderstanding any of the above.

I will investigate why the xsl code is not working for you. It seems to be working for me at the moment.

Quoted 8 lines
Quoted 4 lines

Thank you for the review,
Leah

Thanks Leah

John

Hi John,

Quoted 6 lines

The report should say

Measurement:  measurement threads run on cores  0-2,4,5
Loads:        3 loads run on cores 6-11 (the inverse)
but instead with your patch it says
Loads:        3 loads run on cores 1,2,4,6,7,8,9,10,11
Measurement:  measurement threads run on cores 0-5

Now that I'm looking at the rteval program prior to my changes, I see that this issue existed in the initial pre-report posted to stdout. This seems to be a separate bug in the way that 'self._loadmods._cfg.GetSection("loads").cpulist' and self.__cfg.GetSection("measurement").cpulist are calculated.

When I test your example on the rteval main branch, this is the result:

su -c 'echo 0 > /sys/devices/system/cpu/cpu3/online ' su -c './rteval-cmd -d5s --measurement-cpulist=0-5'

Quoted 8 lines

started 3 loads on cores 1,2,4,6,7
started measurement threads on cores 0-5

Should we file this as a separate bug, since the scope of it goes beyond my current patch?

Thanks,
Leah

Please send a separate patch to fix this.

John