fsl_esdhc: Correcting esdhc timeout counter calculation
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
From: Priyanka Jain <[email protected]>
- Timeout counter value is set as DTOCV bits in SYSCTL register For counter value set as x,
Timeout period = (2^(13+x))/SD_CLOCK
- As per 4.6.2.2 section of SD Card specification v2.00, host should cofigure timeout period value to minimum 250 msec.
- SD_CLOCK = mmc->trans_speed
- Calculating x based on
250 msec = (2^(13+x))/mmc->trans_speed
--- drivers/mmc/fsl_esdhc.c | 5 ++++- 1 files changed, 4 insertions(+), 1 deletions(-)
drivers/mmc/fsl_esdhc.c +4 -1
@@ -210,7 +210,10 @@ static int esdhc_setup_data(struct mmc *mmc, struct mmc_data *data)esdhc_write32 (®s->blkattr, data->blocks <<16 | data->blocksize);/* Calculate the timeout period for data transactions */ - timeout =fls (mmc->tran_speed/10 ) -1 ; +/* Timeout period = (2^(13+timeout))/mmc->trans_speed +* Timeout period should be minimum 250msec as per SD Card spec +*/ + timeout =fls (mmc->tran_speed/4 ); timeout -=13 ;if (timeout >14 )
Signature · 1 line
1.7.2.3
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Dear Kumar Gala,
Quoted 5 lines · In message <[email protected]> you…
- Timeout counter value is set as DTOCV bits in SYSCTL register For counter value set as x,
Timeout period = (2^(13+x))/SD_CLOCK
Quoted 7 lines
- As per 4.6.2.2 section of SD Card specification v2.00, host should cofigure timeout period value to minimum 250 msec.
-
SD_CLOCK=mmc->trans_speed- Calculating x based on
250 msec = (2^(13+x))/mmc->trans_speed
OK, here the theory is given...
drivers/mmc/fsl_esdhc.c static int esdhc_setup_data(struct mmc *mmc, struct mmc_data *data) · line 217
Quoted 5 lines
drivers/mmc/fsl_esdhc.c +4
-0+/* Timeout period = (2^(13+timeout))/mmc->trans_speed +* Timeout period should be minimum 250msec as per SD Card spec +*/ + timeout =fls (mmc->tran_speed/4 ); timeout -=13 ;
But how does this translate intothis formula? I think there must be missing something.
Also, should there not be some checking for valid input data ranges?
Nitpick: incorrect multi-line comment style.
Best regards,
Wolfgang Denk
Signature · 7 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de "There's always been Tower of Babel sort of bickering inside Unix, but this is the most extreme form ever. This means at least several years of confusion." - Bill Gates, founder and chairman of Microsoft, about the Open Systems Foundation
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Quoted 18 lines · Wolfgang Denk
Dear Kumar Gala,
Quoted 5 lines · In message <[email protected]> you…
- Timeout counter value is set as DTOCV bits in SYSCTL register ? For counter value set as x,
? Timeout period = (2^(13+x))/SD_CLOCKQuoted 7 lines
- As per 4.6.2.2 section of SD Card specification v2.00, host should ? cofigure timeout period value to minimum 250 msec.
-
SD_CLOCK=mmc->trans_speed- Calculating x based on
? 250 msec = (2^(13+x))/mmc->trans_speedOK, here the theory is given...
Quoted 8 lines
Quoted 5 lines
+ ? ? /* Timeout period = (2^(13+timeout))/mmc->trans_speed
+ ? ? ?* Timeout period should be minimum 250msec as per SD Card spec
+ ? ? ?*/
+ ? ? timeout =fls(mmc->tran_speed/4);
? ? ? timeout -= 13;But how does this translate intothis formula? ?I think there must be missing something.
Yeah, that took me a while, too. Maybe we should update it to make clear:
1) The formula ends up being (2^(13 + timeout))/mmc->trans_speed = (1/4) seconds --> 2^(13 + timeout) = mmc->trans_speed/4
--> 13 + timeout = log2(mmc->trans_speed/4)
...etc
2) We are effectively rounding up to the next highest power of 2 to make sure the timeout is *at least* 250ms
Andy
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Dear Andy Fleming,
Quoted 7 lines · In message <[email protected]> you…
Yeah, that took me a while, too. Maybe we should update it to make clear:
1) The formula ends up being (2^(13 + timeout))/mmc->trans_speed = (1/4) seconds --> 2^(13 + timeout) = mmc->trans_speed/4
--> 13 + timeout =log2(mmc->trans_speed/4)
...etc
Does this not depend on the units used for speed, and thus in the end on CONFIC_SYS_HZ ?
Best regards,
Wolfgang Denk
Signature · 6 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
The use of COBOL cripples the mind; its teaching should, therefore,
be regarded as a criminal offence.
-- Edsger W. Dijkstra, SIGPLAN Notices, Volume 17, Number 5PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Dear Wolgang Denk
Quoted 17 lines
-----Original Message-----
From: Wolfgang Denk [mailto:wd at denx.de]
Sent: Friday, February 25, 2011 11:06 AM
To: Andy Fleming
Cc: Kumar Gala; u-boot at lists.denx.de; Fleming Andy-AFLEMING; Jain Priyanka-B32167
Subject: Re: [U-Boot] [PATCH]fsl_esdhc: Correcting esdhc timeout counter calculationDear Andy Fleming,
In message <[email protected]>
Quoted 2 lines · you
Yeah, that took me a while, too. Maybe we should update it to make
clear:
Quoted 1 line
Quoted 9 lines
Quoted 5 lines
1) The formula ends up being (2^(13 + timeout))/mmc->trans_speed = (1/4) seconds
--> 2^(13 + timeout) = mmc->trans_speed/4
--> 13 + timeout =log2(mmc->trans_speed/4)
...etcDoes this not depend on the units used for speed, and thus in the end on
CONFIC_SYS_HZ?
We are using absolute figures. So this code is independent of units of speed. For standard speed cards, mmc->tran_speed is 25000000.
Code snippet(mmc.c) of setting tran_speed is:
/* divide frequency by 10, since the mults are 10x bigger */
freq = fbase[(cmd.response[0] & 0x7)];
mult = multipliers[((cmd.response[0] >> 3) & 0xf)];
mmc->tran_speed = freq * mult;Quoted 11 lines
Best regards,
Wolfgang Denk
--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de The use of COBOL cripples the mind; its teaching should, therefore, be regarded as a criminal offence.
-- Edsger W. Dijkstra, SIGPLAN Notices, Volume 17, Number 5
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Dear Jain Priyanka-B32167,
Quoted 11 lines · In message <470DB7CE2CD0944E9436E7ADEFC02FE3138B4C@039-SN1MPN1-003.039d.mgd.msf…
Quoted 10 lines
Quoted 6 lines
1) The formula ends up being (2^(13 + timeout))/mmc->trans_speed =3D (1/4) seconds
--> 2^(13 + timeout) = mmc->trans_speed/4
--> 13 + timeout =log2(mmc->trans_speed/4)
...etcDoes this not depend on the units used for speed, and thus in the end on
CONFIC_SYS_HZ?We are using absolute figures. So this code is independent of units of speed.
Funny you should say that.
Quoted 1 line
For standard speed cards,
mmc->tran_speedis 25000000.
"Speed" is always some unit per time. Your 'absolute" number 25000000 here makes no sense if you cannot tell what it means. Is it bits per millisecond? Bytes per week? Nibbles per year?
Quoted 4 lines
/* divide frequency by 10, since the mults are 10x bigger */
freq = fbase[(cmd.response[0] & 0x7)];
mult = multipliers[((cmd.response[0] >> 3) & 0xf)];
mmc->tran_speed = freq * mult;You don't have any "absolute figures" here. A frequency is defined to measure events per time, so it is important to give the unit used. Is frequency in Hz, or in kHz, or in MHz, or what?
It is impossible for the reader to verify the correctness of the code if you don't provide such information, so please document your code in a way that makes it possible to check it.
Best regards,
Wolfgang Denk
Signature · 4 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de "I haven't lost my mind - it's backed up on tape somewhere."
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
In reply to Wolfgang DenkQuoted 6 lines · Wolfgang Denk
Dear Andy Fleming,
Quoted 3 lines · In message <[email protected]> you…
Yeah, that took me a while, too. Maybe we should update it to make clear:
Quoted 7 lines
Quoted 4 lines
1) The formula ends up being (2^(13 + timeout))/mmc->trans_speed = (1/4) seconds --> 2^(13 + timeout) = mmc->trans_speed/4
--> 13 + timeout =log2(mmc->trans_speed/4)
...etcDoes this not depend on the units used for speed, and thus in the end on
CONFIC_SYS_HZ?
No, but that wasn't apparent because I didn't mention the units of 2^(13+timeout). It is in units of sd clocks.
So: num sd clocks = (sd clocks per sec) * 0.25 sec = mmc->tran_speed/4 = 2^(13+regval).
Now, it is true that the actual speed of the sd clock is going to depend on CONFIG_SYS_HZ, in that a tran_speed of 25MHz may not be perfectly achievable with available dividers, but this code is not taking that into account, and the fact that it's rounding up to the next power of two should take care of that.
Andy
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Dear Fleming Andy-AFLEMING,
Quoted 7 lines · In message <[email protected]> you wrote:
Quoted 3 lines
Does this not depend on the units used for speed, and thus in the end on
CONFIC_SYS_HZ?No, but that wasn't apparent because I didn't mention the units of 2^(13+timeout). It is in units of sd clocks.
Quoted 8 lines
So: num sd clocks = (sd clocks per sec) * 0.25 sec = mmc->tran_speed/4 = 2^(13+regval).
Now, it is true that the actual speed of the sd clock is going to depend on
CONFIG_SYS_HZ, in that atran_speedof 25MHz may not be perfectly achievable with available dividers, but this code is not taking that into account, and the fact that it's rounding up to the next power of two should take care of that.
Fine. Can we please add such explanation to the code?
Thanks.
Best regards,
Wolfgang Denk
Signature · 6 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
The use of COBOL cripples the mind; its teaching should, therefore,
be regarded as a criminal offence.
-- Edsger W. Dijkstra, SIGPLAN Notices, Volume 17, Number 5PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
In reply to Kumar GalaQuoted 14 lines · Kumar Gala
From: Priyanka Jain <[email protected]>
- Timeout counter value is set as DTOCV bits in SYSCTL register For counter value set as x,
Timeout period = (2^(13+x))/SD_CLOCK- As per 4.6.2.2 section of SD Card specification v2.00, host should cofigure timeout period value to minimum 250 msec.
-
SD_CLOCK=mmc->trans_speed- Calculating x based on
250 msec = (2^(13+x))/mmc->trans_speed
Quoted 6 lines
Signed-off-by Priyanka Jain <[email protected]>Signed-off-by Andy Fleming <[email protected]>Signed-off-by Kumar Gala <[email protected]>---
drivers/mmc/fsl_esdhc.c| 5 ++++-1 files changed, 4 insertions(+), 1 deletions(-)
Stefano,
Can you test this on iMX to make sure we didnt break anything there.
Quoted 24 lines
drivers/mmc/fsl_esdhc.c +4
-1@@ -210,7 +210,10 @@ static int esdhc_setup_data(struct mmc *mmc, struct mmc_data *data)esdhc_write32 (®s->blkattr, data->blocks <<16 | data->blocksize);/* Calculate the timeout period for data transactions */ - timeout =fls (mmc->tran_speed/10 ) -1 ; +/* Timeout period = (2^(13+timeout))/mmc->trans_speed +* Timeout period should be minimum 250msec as per SD Card spec +*/ + timeout =fls (mmc->tran_speed/4 ); timeout -=13 ;if (timeout >14 )Signature · 6 lines
1.7.2.3 _______________________________________________ U-Boot mailing list U-Boot at lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot
PATCH 1/1 fsl_esdhc: Correcting esdhc timeout counter calculation
Quoted 24 lines · Kumar Gala
Quoted 14 lines · Kumar Gala
From: Priyanka Jain <[email protected]>
- Timeout counter value is set as DTOCV bits in SYSCTL register For counter value set as x,
Timeout period = (2^(13+x))/SD_CLOCK- As per 4.6.2.2 section of SD Card specification v2.00, host should cofigure timeout period value to minimum 250 msec.
-
SD_CLOCK=mmc->trans_speed- Calculating x based on
250 msec = (2^(13+x))/mmc->trans_speedQuoted 6 lines
Signed-off-by Priyanka Jain <[email protected]>Signed-off-by Andy Fleming <[email protected]>Signed-off-by Kumar Gala <[email protected]>---
drivers/mmc/fsl_esdhc.c| 5 ++++-1 files changed, 4 insertions(+), 1 deletions(-)
Quoted 3 lines
Stefano,
Can you test this on iMX to make sure we didnt break anything there.
Yes, I will test it and I will send my tested-by if everything is ok.
Stefano
Signature · 5 lines
===================================================================== DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office at denx.de =====================================================================