virtio: Avoid virtio_net TX queue over run

PATCH In review Shirley Ma 3 participants 7 messages Mar 17, 2011

Subsystems (3)
lore
Share & tools
lore

Shirley Ma

author
#0 lore raw

PATCH 1/1 virtio: Avoid virtio_net TX queue over run

This patch addresses small message size performance in a situation the KVM guest virtio_net TX queue overrun. This patch adds a new API in virtio_ring for ring capacity check; and remove KVM guest virtio_net TX queue send completion interrupts completely. The test has shown that whenever the queue is overrun, it's much better to drop a few packets than stopping TX queue and waiting for host to notify the guest to wake up the TX queue again, the small messages size performance gain for single TCP_STREAM BW could be up to 200%-300% and better than bare metal, and no regression has been found in other situation.

Performance data for 10GbE,

KVM guest to local host:
------------------------
Message size 2.6.38-rc8 2.6.38-rc8+patch
1024 1770.61 4528.37
2048 2702.30 7110.95
4096 5256.84 10104.76
8192 7543.66 10945.93
16K 10500.47 10783.50
64K 13718.62 13640.80

KVM guest to remote host:
--------------------------
Message size Bare Metal 2.6.38-rc8 2.6.38-rc8+patch
1024 1802.67 2381.41 5599.15
2048 4317.87 4094.12 9241.86
4096 6266.15 5231.24 9321.87
8192 8409.17 7952.74 9265.45
16K 9351.63 8260.68 8310.29
64K 9347.94 9103.75 9094.38

Thanks
Shirley

#1 lore raw
Quoted 32 lines · Shirley Ma

This patch addresses small message size performance in a situation the KVM guest virtio_net TX queue overrun. This patch adds a new API in virtio_ring for ring capacity check; and remove KVM guest virtio_net TX queue send completion interrupts completely. The test has shown that whenever the queue is overrun, it's much better to drop a few packets than stopping TX queue and waiting for host to notify the guest to wake up the TX queue again, the small messages size performance gain for single TCP_STREAM BW could be up to 200%-300% and better than bare metal, and no regression has been found in other situation.

Performance data for 10GbE,

KVM guest to local host:
------------------------
Message size 2.6.38-rc8 2.6.38-rc8+patch
1024 1770.61 4528.37
2048 2702.30 7110.95
4096 5256.84 10104.76
8192 7543.66 10945.93
16K 10500.47 10783.50
64K 13718.62 13640.80

KVM guest to remote host:
--------------------------
Message size Bare Metal 2.6.38-rc8 2.6.38-rc8+patch
1024 1802.67 2381.41 5599.15
2048 4317.87 4094.12 9241.86
4096 6266.15 5231.24 9321.87
8192 8409.17 7952.74 9265.45
16K 9351.63 8260.68 8310.29
64K 9347.94 9103.75 9094.38

Quoted 2 lines

Thanks
Shirley

Could you add CPU utilization data pls? I also wonder what does this do to UDP? Won't a lot of packets be dropped?

Signature · 1 line
MST
author
#2 lore raw
Quoted 3 lines · Michael S. Tsirkin

Could you add CPU utilization data pls? I also wonder what does this do
to UDP? Won't a lot of packets be dropped?

Guest CPU utilization slightly increased a few %.

UDP performance send rate increased 200% - 400%, recv rate increased from 10% to around 40% w/i recv errors. I will tune the buffers to see any better.

I am putting all data together and post the results here soon.

Thanks
Shirley

#3 lore raw
Quoted 5 lines · Shirley Ma
Quoted 3 lines · Michael S. Tsirkin

Could you add CPU utilization data pls? I also wonder what does this do
to UDP? Won't a lot of packets be dropped?

Quoted 7 lines

Guest CPU utilization slightly increased a few %.

UDP performance send rate increased 200% - 400%, recv rate increased from 10% to around 40% w/i recv errors. I will tune the buffers to see any better.

I am putting all data together and post the results here soon.

Could you run your tests with only one cpu ?
(offline all cpus but cpu0 on your hypervisor)

Dropping packets is fine, unless consumer cant run ;)

author
#4 lore raw
Quoted 4 lines · Eric Dumazet

Could you run your tests with only one cpu ?
(offline all cpus but cpu0 on your hypervisor)

Dropping packets is fine, unless consumer cant run ;)

Sure, will report the data soon.

Thanks
Shirley

author
#5 lore raw
Quoted 7 lines · Shirley Ma
Quoted 4 lines · Eric Dumazet

Could you run your tests with only one cpu ?
(offline all cpus but cpu0 on your hypervisor)

Dropping packets is fine, unless consumer cant run ;)

Sure, will report the data soon.

With a single CPU, before/after with this patch the performance has no difference for both UDP and TCP, and it seems hitting TX overrun, CPU is 100% used.

Thanks
Shirley

author
#6 lore raw
Quoted 4 lines · Shirley Ma

With a single CPU, before/after with this patch the performance has no difference for both UDP and TCP, and it seems hitting TX overrun, CPU is
100% used.

Sorry, should be: it seems never hitting TX overrun.

Shirley