p4080ds: add README.p4080ds which documents the "serdes" hwconfig option
PATCH 1/2 p4080ds: add README.p4080ds which documents the "serdes" hwconfig option
From: Timur Tabi <[email protected]>
Add documentation for the "serdes" hwconfig option, which is used to specify the status of SerDes banks two and three for the SERDES8 erratum work-around.
Signed-off-by Timur Tabi <[email protected]>
Signed-off-by Kumar Gala <[email protected]>
--- doc/README.p4080ds | 32 ++++++++++++++++++++++++++++++++ 1 files changed, 32 insertions(+), 0 deletions(-) create mode 100644 doc/README.p4080ds
doc/README.p4080ds new file +32 -0
@@ -0,0 +1,32 @@ +Overview +-------- +The P4080DS is a Freescale reference board that hosts the eight-core P4080 SOC. + +SerDes hwconfig configuration +----------------------------- +The P4080 RCW includes three sets of bits the specify which SerDes lanes +should be powered down: SRDS_LPD_B1 (for bank one), SRDS_LPD_B2 (for bank two), +and SRDS_LPD_B3 (for bank three). Each of these contains four bits, one for +each lane in the bank. SerDes Erratum SERDES8 requires that SRDS_LPD_B2 and +SRDS_LPD_B3 be set to 0b1111. This forces banks two and three to be powered +down at reset. + +To re-enable these banks in U-Boot, two hwconfig are available: +"fsl_srds_lpd_b2" and "fsl_srds_lpd_b3". The value passed via fsl_srds_lpd_b2 +is written into SRDS_LPD_B2, and the value passed via fsl_srds_lpd_b3 is into +SRDS_LPD_B3. Each bit represents one of each bank, and a value of '1' +indicates that the lane should be powered down. + +For example, to indicate that both SerDes banks 2 and 3 are powered down, add +the following to hwconfig: + + serdes:fsl_srds_lpd_b2=0xf,fsl_srds_lpd_b3=0xf + +The "0xf" is a mask that corresponds to the 4 lanes A-D. The most significant +bit corresponds to lane A. To indicate that just lane A of bank 3 is to be +powered down, use: + + serdes:fsl_srds_lpd_b3=8 + +These options should be specified only if U-Boot does not automatically power +on the correct lanes.
Signature · 1 line
1.7.3.4
PATCH 2/2 p4080ds: remove rev1-specific code for the SERDES8 erratum
From: Timur Tabi <[email protected]>
Remove the SERDES8 erratum work-around code that only applied to P4080 rev1, which is not supported by this version of U-Boot.
Signed-off-by Timur Tabi <[email protected]>
Signed-off-by Kumar Gala <[email protected]>
--- arch/powerpc/cpu/mpc85xx/fsl_corenet_serdes.c | 106 +++++++++++-------------- 1 files changed, 47 insertions(+), 59 deletions(-)
arch/powerpc/cpu/mpc85xx/fsl_corenet_serdes.c +47 -59
@@ -109,10 +109,13 @@ int serdes_lane_enabled(int lane)return 0 ;#ifdef CONFIG_SYS_P4080_ERRATUM_SERDES8 -if (!IS_SVR_REV (get_svr (),1 ,0 )) -if (bank >0 ) -return !(srds_lpd_b[bank] & - (8 >> (lane - (6 +4 * bank)))); +/* +* For banks two and three, use the srds_lpd_b[] array instead of the +* RCW, because this array contains the real values of SRDS_LPD_B2 and +* SRDS_LPD_B3. +*/ +if (bank >0 ) +return !(srds_lpd_b[bank] & (8 >> (lane - (6 +4 * bank))));#endif return !(in_be32 (&gur->rcwsr[word]) & (0x80000000 >> bit));
@@ -303,15 +306,19 @@ void fsl_serdes_init(void) }#ifdef CONFIG_SYS_P4080_ERRATUM_SERDES8 -if (!IS_SVR_REV (get_svr (),1 ,0 )) -for (bank =1 ; bank <ARRAY_SIZE (srds_lpd_b); bank++) { -sprintf (srds_lpd_opt,"fsl_srds_lpd_b%u" , bank +1 ); - srds_lpd_arg =hwconfig_subarg_f ("serdes" , srds_lpd_opt, - &arglen, buf); -if (srds_lpd_arg) - srds_lpd_b[bank] =simple_strtoul (srds_lpd_arg, -NULL ,0 ); - } +/* +* Store the values of the fsl_srds_lpd_b2 and fsl_srds_lpd_b3 +* hwconfig options into the srds_lpd_b[] array. See README.p4080ds +* for a description of these options. +*/ +for (bank =1 ; bank <ARRAY_SIZE (srds_lpd_b); bank++) { +sprintf (srds_lpd_opt,"fsl_srds_lpd_b%u" , bank +1 ); + srds_lpd_arg = +hwconfig_subarg_f ("serdes" , srds_lpd_opt, &arglen, buf); +if (srds_lpd_arg) + srds_lpd_b[bank] = +simple_strtoul (srds_lpd_arg,NULL ,0 ) &0xf ; + }#endif /* Look for banks with all lanes disabled, and power down the bank. */
@@ -324,32 +331,12 @@ void fsl_serdes_init(void) }#ifdef CONFIG_SYS_P4080_ERRATUM_SERDES8 -if (IS_SVR_REV (get_svr (),1 ,0 )) { -/* At least one bank must be disabled due to SERDES8. If -* no bank is found to be disabled based on lane -* disables, disable bank 3 because we can't turn off its -* lanes in the RCW without disabling MDIO due to erratum -* GEN8. -* -* This means that if you are relying on bank 3 being -* disabled to avoid SERDES8, in some cases you cannot -* also disable all lanes of another bank, or else bank -* 3 won't be disabled, leaving you with a configuration -* that isn't valid according to SERDES8 (e.g. if banks -* 2 and 3 have the same clock, and bank 1 is disabled -* instead of 3). -*/ -for (bank =0 ; bank <SRDS_MAX_BANK ; bank++) { -if (!have_bank[bank]) -break ; - } - -if (bank ==SRDS_MAX_BANK ) - have_bank[FSL_SRDS_BANK_3 ] =0 ; - }else { -if (have_bank[FSL_SRDS_BANK_2 ]) - have_bank[FSL_SRDS_BANK_3 ] =1 ; - } +/* +* Bank two uses the clock from bank three, so if bank two is enabled, +* then bank three must also be enabled. +*/ +if (have_bank[FSL_SRDS_BANK_2 ]) + have_bank[FSL_SRDS_BANK_3 ] =1 ;#endif for (bank =0 ; bank <SRDS_MAX_BANK ; bank++) {
@@ -455,19 +442,16 @@ void fsl_serdes_init(void) bank = idx;#ifdef CONFIG_SYS_P4080_ERRATUM_SERDES8 -if (!IS_SVR_REV (get_svr (),1 ,0 )) { -/* -* Change bank init order to 0, 2, 1, so that the -* third bank's PLL is established before we -* start the second bank which shares the third -* bank's PLL. -*/ +/* +* Change bank init order to 0, 2, 1, so that the third bank's +* PLL is established before we start the second bank. The +* second bank uses the third bank's PLL. +*/ -if (idx ==1 ) - bank =FSL_SRDS_BANK_3 ; -else if (idx ==2 ) - bank =FSL_SRDS_BANK_2 ; - } +if (idx ==1 ) + bank =FSL_SRDS_BANK_3 ; +else if (idx ==2 ) + bank =FSL_SRDS_BANK_2 ;#endif /* Skip disabled banks */
@@ -475,14 +459,18 @@ void fsl_serdes_init(void)continue ;#ifdef CONFIG_SYS_P4080_ERRATUM_SERDES8 -if (!IS_SVR_REV (get_svr (),1 ,0 )) { -if (idx ==1 ) { -p4080_erratum_serdes8 (srds_regs, gur, - serdes8_devdisr, - serdes8_devdisr2, cfg); - }else if (idx ==2 ) { -enable_bank (gur,FSL_SRDS_BANK_2 ); - } +if (idx ==1 ) { +/* +* Re-enable devices on banks two and three that were +* disabled by the RCW, and then enable bank three. The +* devices need to be enabled before either bank is +* powered up. +*/ +p4080_erratum_serdes8 (srds_regs, gur, serdes8_devdisr, + serdes8_devdisr2, cfg); + }else if (idx ==2 ) { +/* Eable bank two now that bank three is enabled. */ +enable_bank (gur,FSL_SRDS_BANK_2 ); }#endif
Signature · 1 line
1.7.3.4