Health Thermometer Profile (HTP)
This is a new set of patches to enhance thermometer plugin fuctionality. These patches enable watchers to receiave final/intermediate measurements from thermometers devices.
[PATCH 1/6] Manage GATT attribute indications in handle callback. [PATCH 2/6] Parse final measurement indication
[PATCH 3/6] Add org.bluez.ThermometerWatcher interface to default [PATCH 4/6] Implement EnableIntermediateMeasurement D-Bus method [PATCH 5/6] Implement DisableIntermediateMeasurement D-Bus method [PATCH 6/6] Notify intermediate measurements
PATCH 1/6 Manage GATT attribute indications in handle callback.
--- thermometer/thermometer.c | 57 ++++++++++++++++++++++++++++++++++++++++++++- 1 files changed, 56 insertions(+), 1 deletions(-)
thermometer/thermometer.c +56 -1
@@ -163,6 +163,17 @@ static gint cmp_char_uuid(gconstpointer a, gconstpointer b)return g_strcmp0 (ch->attr.uuid, uuid); } +static gint cmp_char_val_handle (gconstpointer a,gconstpointer b) +{ +const struct characteristic *ch = a; +const uint16_t *handle = b; + +if (ch->attr.value_handle == *handle) +return 0 ; + +return -1 ; +} +static gint cmp_descriptor (gconstpointer a,gconstpointer b) {const struct descriptor *desc = a;
@@ -703,9 +714,53 @@ static GDBusSignalTable thermometer_signals[] = { { } }; +static void proc_measurement (struct thermometer *t,const uint8_t *pdu, +uint16_t len,gboolean final) +{ +DBG ("TODO: Process measurement indication" ); +} + +static void proc_measurement_interval (struct thermometer *t,const uint8_t *pdu, +uint16_t len) +{ +DBG ("TODO: Process measurements interval indication" ); +} +static void ind_handler (const uint8_t *pdu,uint16_t len,gpointer user_data) { -/* TODO: Process indication */ +struct thermometer *t = user_data; +const struct characteristic *ch; +uint8_t opdu[ATT_MAX_MTU ]; +uint16_t handle, olen; +GSList *l; + +if (len <3 ) { +DBG ("Bad pdu received" ); + goto done; + } + +if (pdu[0 ] !=ATT_OP_HANDLE_IND ) { +DBG ("Not indication received" ); +return ; + } + + handle =att_get_u16 (&pdu[1 ]); + l =g_slist_find_custom (t->chars, &handle, cmp_char_val_handle); +if (l ==NULL ) + goto done; + + ch = l->data; +if (g_strcmp0 (ch->attr.uuid,TEMPERATURE_MEASUREMENT_UUID ) ==0 ) +proc_measurement (t, pdu, len, TRUE); +else if (g_strcmp0 (ch->attr.uuid,MEASUREMENT_INTERVAL_UUID ) ==0 ) +proc_measurement_interval (t, pdu, len); + +done: + olen =enc_confirmation (opdu,sizeof (opdu)); + +if (olen >0 ) +g_attrib_send (t->attrib,0 , opdu[0 ], opdu, olen,NULL ,NULL , +NULL ); }static void attio_connected_cb (GAttrib *attrib,gpointer user_data)
Signature · 1 line
1.7.7.2
PATCH 2/6 Parse final measurement indication
--- thermometer/thermometer.c | 154 ++++++++++++++++++++++++++++++++++++++++++++- 1 files changed, 153 insertions(+), 1 deletions(-)
thermometer/thermometer.c +153 -1
@@ -47,6 +47,13 @@#define INTERMEDIATE_TEMPERATURE_UUID "00002a1e-0000-1000-8000-00805f9b34fb"#define MEASUREMENT_INTERVAL_UUID "00002a21-0000-1000-8000-00805f9b34fb" +/* Temperature measurement flag fields */ +#define TEMP_UNITS 0x01 +#define TEMP_TIME_STAMP 0x02 +#define TEMP_TYPE 0x04 + +#define FLOAT_MAX_MANTISSA 16777216/* 2^24 */ +struct thermometer {DBusConnection *conn;/* The connection to the bus */ struct btd_device *dev;/* Device reference */
@@ -84,8 +91,36 @@ struct watcher {gchar *path; }; +struct measurement { +gint16 exp; +gint32 mant; +guint64 time; +gboolean suptime; +gchar *unit; +gchar *type; +gchar *msmnt; +}; +static GSList *thermometers =NULL ; +static gchar *temptype2str (uint8_t value) +{ +switch (value) { +case 1 :return "Armpit" ; +case 2 :return "Body" ; +case 3 :return "Ear" ; +case 4 :return "Finger" ; +case 5 :return "Intestines" ; +case 6 :return "Mouth" ; +case 7 :return "Rectum" ; +case 8 :return "Toe" ; +case 9 :return "Tympanum" ; +default : +error ("Temperature type %d reserved for future use" , value); +return NULL ; + }; +} +static void destroy_watcher (gpointer user_data) {struct watcher *watcher = user_data;
@@ -714,10 +749,127 @@ static GDBusSignalTable thermometer_signals[] = { { } }; +static void update_watcher (struct watcher *w,struct measurement *m) +{ +DBusConnection *conn = w->t->conn; +DBusMessageIter iter; +DBusMessageIter dict; +DBusMessage *msg; + + msg =dbus_message_new_method_call (w->srv, w->path, +"org.bluez.ThermometerWatcher" , +"MeasurementReceived" ); +if (msg ==NULL ) +return ; + +dbus_message_iter_init_append (msg, &iter); + +dbus_message_iter_open_container (&iter,DBUS_TYPE_ARRAY , +DBUS_DICT_ENTRY_BEGIN_CHAR_AS_STRING + DBUS_TYPE_STRING_AS_STRING DBUS_TYPE_VARIANT_AS_STRING + DBUS_DICT_ENTRY_END_CHAR_AS_STRING, &dict); + +dict_append_entry (&dict,"Exponent" ,DBUS_TYPE_INT16 , &m->exp); +dict_append_entry (&dict,"Mantissa" ,DBUS_TYPE_INT32 , &m->mant); +dict_append_entry (&dict,"Unit" ,DBUS_TYPE_STRING , &m->unit); + +if (m->suptime) +dict_append_entry (&dict,"Time" ,DBUS_TYPE_UINT64 , &m->time); + +dict_append_entry (&dict,"Type" ,DBUS_TYPE_STRING , &m->type); +dict_append_entry (&dict,"Measurement" ,DBUS_TYPE_STRING , &m->msmnt); + +dbus_message_iter_close_container (&iter, &dict); + +dbus_message_set_no_reply (msg, TRUE); +g_dbus_send_message (conn, msg); +} + +static void recv_measurement (struct thermometer *t,struct measurement *msmt) +{ +GSList *l; + +if (g_strcmp0 (msmt->msmnt,"Intermediate" ) ==0 ) { +DBG ("Notification of intermediate measurement not implemented" ); +return ; + } + +for (l = t->fwatchers; l; l = l->next) +update_watcher (l->data, msmt); +} +static void proc_measurement (struct thermometer *t,const uint8_t *pdu,uint16_t len,gboolean final) { -DBG ("TODO: Process measurement indication" ); +struct measurement msmt; +uint8_t flags; +uint32_t raw; + +if (len <4 ) { +DBG ("Mandatory flags are not provided" ); +return ; + } + + flags = pdu[3 ]; +if (flags &TEMP_UNITS ) + msmt.unit ="Fahrenheit" ; +else + msmt.unit ="Celsius" ; + +if (len <8 ) { +DBG ("Temperature measurement value is not provided" ); +return ; + } + + raw =att_get_u32 (&pdu[4 ]); + msmt.mant = raw &0x00FFFFFF ; + msmt.exp = ((gint32 ) raw) >>24 ; + +if (msmt.mant &0x00800000 ) { +/* convert to C2 negative value */ + msmt.mant = msmt.mant -FLOAT_MAX_MANTISSA ; + } + +if (flags &TEMP_TIME_STAMP ) { +struct tm ts; +time_t time; + +if (len <15 ) { +DBG ("Can't get time stamp value" ); +return ; + } + + ts.tm_year =att_get_u16 (&pdu[8 ]) -1900 ; + ts.tm_mon = pdu[10 ]; + ts.tm_mday = pdu[11 ]; + ts.tm_hour = pdu[12 ]; + ts.tm_min = pdu[13 ]; + ts.tm_sec = pdu[14 ]; + ts.tm_isdst =-1 ; + + time =mktime (&ts); + msmt.time = (guint64 ) time; + msmt.suptime = TRUE; + }else + msmt.suptime = FALSE; + +if (flags &TEMP_TYPE ) { +if (len <16 ) { +DBG ("Can't get temperature type" ); +return ; + } + + msmt.type =temptype2str (pdu[15 ]); + }else if (t->has_type) + msmt.type =temptype2str (t->type); +else { +DBG ("Can't get temperature type" ); +return ; + } + + msmt.msmnt = final ?"Final" :"Intermediate" ; + +recv_measurement (t, &msmt); } static void proc_measurement_interval(struct thermometer *t, const uint8_t *pdu,
Signature · 1 line
1.7.7.2
PATCH 3/6 Add org.bluez.ThermometerWatcher interface to default policy
--- src/bluetooth.conf | 1 + 1 files changed, 1 insertions(+), 0 deletions(-)
src/bluetooth.conf +1 -0
@@ -15,6 +15,7 @@ <allow send_interface="org.bluez.MediaEndpoint"/> <allow send_interface="org.bluez.MediaPlayer"/> <allow send_interface="org.bluez.Watcher"/> + <allow send_interface="org.bluez.ThermometerWatcher"/> </policy> <policy at_console="true">
Signature · 1 line
1.7.7.2
PATCH 4/6 Implement EnableIntermediateMeasurement D-Bus method
--- thermometer/thermometer.c | 74 +++++++++++++++++++++++++++++++++++++------- 1 files changed, 62 insertions(+), 12 deletions(-)
thermometer/thermometer.c +62 -12
@@ -63,6 +63,7 @@ struct thermometer {guint attindid;/* Att incications id */ GSList *chars;/* Characteristics */ GSList *fwatchers;/* Final measurements */ +GSList *iwatchers;/* Intermediate measurements */ gboolean intermediate;guint8 type;guint16 interval;
@@ -557,7 +558,7 @@ static struct descriptor *get_descriptor(struct characteristic *ch,return l->data; } -static void final_measurement_cb (guint8 status,const guint8 *pdu, +static void measurement_cb (guint8 status,const guint8 *pdu,guint16 len,gpointer user_data) {gchar *msg = user_data;
@@ -592,8 +593,34 @@ static void enable_final_measurement(struct thermometer *t) atval[0 ] =0x02 ; atval[1 ] =0x00 ; msg =g_strdup ("Enable final measurement" ); -gatt_write_char (t->attrib, desc->handle, atval,2 , - final_measurement_cb, msg); +gatt_write_char (t->attrib, desc->handle, atval,2 , measurement_cb, msg); +} + +static void enable_intermediate_measurement (struct thermometer *t) +{ +struct characteristic *ch; +struct descriptor *desc; +bt_uuid_t btuuid; +uint8_t atval[2 ]; +gchar *msg; + + ch =get_characteristic (t,INTERMEDIATE_TEMPERATURE_UUID ); +if (ch ==NULL ) { +DBG ("Intermediate measurement characteristic not found" ); +return ; + } + +bt_uuid16_create (&btuuid,GATT_CLIENT_CHARAC_CFG_UUID ); + desc =get_descriptor (ch, &btuuid); +if (desc ==NULL ) { +DBG ("Client characteristic configuration descriptor not found" ); +return ; + } + + atval[0 ] =0x01 ; + atval[1 ] =0x00 ; + msg =g_strdup ("Enable intermediate measurement" ); +gatt_write_char (t->attrib, desc->handle, atval,2 , measurement_cb, msg); }static void disable_final_measurement (struct thermometer *t)
@@ -620,8 +647,7 @@ static void disable_final_measurement(struct thermometer *t) atval[0 ] =0x00 ; atval[1 ] =0x00 ; msg =g_strdup ("Disable final measurement" ); -gatt_write_char (t->attrib, desc->handle, atval,2 , - final_measurement_cb, msg); +gatt_write_char (t->attrib, desc->handle, atval,2 , measurement_cb, msg); }static void watcher_exit (DBusConnection *conn,void *user_data)
@@ -638,7 +664,7 @@ static void watcher_exit(DBusConnection *conn, void *user_data)disable_final_measurement (t); } -static struct watcher *find_watcher (struct thermometer *t,const gchar *sender, +static struct watcher *find_watcher (GSList *list,const gchar *sender,const gchar *path) {struct watcher *match;
@@ -648,7 +674,7 @@ static struct watcher *find_watcher(struct thermometer *t, const gchar *sender, match->srv =g_strdup (sender); match->path =g_strdup (path); - l =g_slist_find_custom (t->fwatchers, match, cmp_watcher); + l =g_slist_find_custom (list, match, cmp_watcher);destroy_watcher (match);if (l !=NULL )
@@ -669,7 +695,7 @@ static DBusMessage *register_watcher(DBusConnection *conn, DBusMessage *msg, DBUS_TYPE_INVALID))return btd_error_invalid_args (msg); - watcher =find_watcher (t, sender, path); + watcher =find_watcher (t->fwatchers, sender, path);if (watcher !=NULL )return btd_error_already_exists (msg);
@@ -702,7 +728,7 @@ static DBusMessage *unregister_watcher(DBusConnection *conn, DBusMessage *msg, DBUS_TYPE_INVALID))return btd_error_invalid_args (msg); - watcher =find_watcher (t, sender, path); + watcher =find_watcher (t->fwatchers, sender, path);if (watcher ==NULL )return btd_error_does_not_exist (msg);
@@ -720,9 +746,33 @@ static DBusMessage *unregister_watcher(DBusConnection *conn, DBusMessage *msg,static DBusMessage *enable_intermediate (DBusConnection *conn,DBusMessage *msg,void *data) { -/* TODO: */ -return g_dbus_create_error (msg,ERROR_INTERFACE ".ThermometerError" , -"Function not implemented." ); +const gchar *sender =dbus_message_get_sender (msg); +struct thermometer *t = data; +struct watcher *watcher; +gchar *path; + +if (!t->intermediate) +return btd_error_not_supported (msg); + +if (!dbus_message_get_args (msg,NULL ,DBUS_TYPE_OBJECT_PATH , &path, +DBUS_TYPE_INVALID )) +return btd_error_invalid_args (msg); + + watcher =find_watcher (t->fwatchers, sender, path); +if (watcher ==NULL ) +return btd_error_does_not_exist (msg); + +if (find_watcher (t->iwatchers, sender, path)) +return btd_error_already_exists (msg); + +DBG ("Intermediate measurement watcher %s registered" , path); + +if (g_slist_length (t->iwatchers) ==0 ) +enable_intermediate_measurement (t); + + t->iwatchers =g_slist_prepend (t->iwatchers, watcher); + +return dbus_message_new_method_return (msg); } static DBusMessage *disable_intermediate(DBusConnection *conn, DBusMessage *msg,
Signature · 1 line
1.7.7.2
PATCH 5/6 Implement DisableIntermediateMeasurement D-Bus method
--- thermometer/thermometer.c | 63 ++++++++++++++++++++++++++++++++++++++++++-- 1 files changed, 60 insertions(+), 3 deletions(-)
thermometer/thermometer.c +60 -3
@@ -650,6 +650,44 @@ static void disable_final_measurement(struct thermometer *t)gatt_write_char (t->attrib, desc->handle, atval,2 , measurement_cb, msg); } +static void disable_intermediate_measurement (struct thermometer *t) +{ +struct characteristic *ch; +struct descriptor *desc; +bt_uuid_t btuuid; +uint8_t atval[2 ]; +gchar *msg; + + ch =get_characteristic (t,INTERMEDIATE_TEMPERATURE_UUID ); +if (ch ==NULL ) { +DBG ("Intermediate measurement characteristic not found" ); +return ; + } + +bt_uuid16_create (&btuuid,GATT_CLIENT_CHARAC_CFG_UUID ); + desc =get_descriptor (ch, &btuuid); +if (desc ==NULL ) { +DBG ("Client characteristic configuration descriptor not found" ); +return ; + } + + atval[0 ] =0x00 ; + atval[1 ] =0x00 ; + msg =g_strdup ("Disable intermediate measurement" ); +gatt_write_char (t->attrib, desc->handle, atval,2 , measurement_cb, msg); +} + +static void remove_int_watcher (struct thermometer *t,struct watcher *w) +{ +if (!g_slist_find (t->iwatchers, w)) +return ; + + t->iwatchers =g_slist_remove (t->iwatchers, w); + +if (g_slist_length (t->iwatchers) ==0 ) +disable_intermediate_measurement (t); +} +static void watcher_exit (DBusConnection *conn,void *user_data) {struct watcher *watcher = user_data;
@@ -657,6 +695,8 @@ static void watcher_exit(DBusConnection *conn, void *user_data)DBG ("Thermometer watcher %s disconnected" , watcher->path); +remove_int_watcher (t, watcher); + t->fwatchers =g_slist_remove (t->fwatchers, watcher); watcher->id =0 ;
@@ -734,6 +774,8 @@ static DBusMessage *unregister_watcher(DBusConnection *conn, DBusMessage *msg,DBG ("Thermometer watcher %s unregistered" , path); +remove_int_watcher (t, watcher); + t->fwatchers =g_slist_remove (t->fwatchers, watcher);destroy_watcher (watcher);
@@ -778,9 +820,24 @@ static DBusMessage *enable_intermediate(DBusConnection *conn, DBusMessage *msg,static DBusMessage *disable_intermediate (DBusConnection *conn,DBusMessage *msg,void *data) { -/* TODO: */ -return g_dbus_create_error (msg,ERROR_INTERFACE ".ThermometerError" , -"Function not implemented." ); +const gchar *sender =dbus_message_get_sender (msg); +struct thermometer *t = data; +struct watcher *watcher; +gchar *path; + +if (!dbus_message_get_args (msg,NULL ,DBUS_TYPE_OBJECT_PATH , &path, +DBUS_TYPE_INVALID )) +return btd_error_invalid_args (msg); + + watcher =find_watcher (t->iwatchers, sender, path); +if (watcher ==NULL ) +return btd_error_does_not_exist (msg); + +DBG ("Intermediate measurement %s unregistered" , path); + +remove_int_watcher (t, watcher); + +return dbus_message_new_method_return (msg); }static GDBusMethodTable thermometer_methods[] = {
Signature · 1 line
1.7.7.2
PATCH 6/6 Notify intermediate measurements
--- thermometer/thermometer.c | 50 +++++++++++++++++++++++++++++++++++++++----- 1 files changed, 44 insertions(+), 6 deletions(-)
thermometer/thermometer.c +44 -6
@@ -61,6 +61,7 @@ struct thermometer {struct att_range *svc_range;/* Thermometer range */ guint attioid;/* Att watcher id */ guint attindid;/* Att incications id */ +guint attnotid;/* Att notifications id */ GSList *chars;/* Characteristics */ GSList *fwatchers;/* Final measurements */ GSList *iwatchers;/* Intermediate measurements */
@@ -152,6 +153,9 @@ static void destroy_thermometer(gpointer user_data)if (t->attindid >0 )g_attrib_unregister (t->attrib, t->attindid); +if (t->attnotid >0 ) +g_attrib_unregister (t->attrib, t->attnotid); +if (t->attrib !=NULL )g_attrib_unref (t->attrib);
@@ -894,14 +898,14 @@ static void update_watcher(struct watcher *w, struct measurement *m)static void recv_measurement (struct thermometer *t,struct measurement *msmt) { -GSList *l; +GSList *l, *ll; -if (g_strcmp0 (msmt->msmnt,"Intermediate" ) ==0 ) { -DBG ("Notification of intermediate measurement not implemented" ); -return ; - } +if (g_strcmp0 (msmt->msmnt,"Intermediate" ) ==0 ) + ll = t->iwatchers; +else + ll = t->fwatchers; -for (l = t->fwatchers; l; l = l->next) +for (l = ll; l; l = l->next)update_watcher (l->data, msmt); }
@@ -1022,6 +1026,33 @@ done: NULL); } +static void notif_handler (const uint8_t *pdu,uint16_t len,gpointer user_data) +{ +struct thermometer *t = user_data; +const struct characteristic *ch; +uint16_t handle; +GSList *l; + +if (len <3 ) { +DBG ("Bad pdu received" ); +return ; + } + +if (pdu[0 ] !=ATT_OP_HANDLE_NOTIFY ) { +DBG ("Not notification received" ); +return ; + } + + handle =att_get_u16 (&pdu[1 ]); + l =g_slist_find_custom (t->chars, &handle, cmp_char_val_handle); +if (l ==NULL ) +return ; + + ch = l->data; +if (g_strcmp0 (ch->attr.uuid,INTERMEDIATE_TEMPERATURE_UUID ) ==0 ) +proc_measurement (t, pdu, len, FALSE); +} +static void attio_connected_cb (GAttrib *attrib,gpointer user_data) {struct thermometer *t = user_data;
@@ -1030,6 +1061,8 @@ static void attio_connected_cb(GAttrib *attrib, gpointer user_data) t->attindid =g_attrib_register (t->attrib,ATT_OP_HANDLE_IND , ind_handler, t,NULL ); + t->attnotid =g_attrib_register (t->attrib,ATT_OP_HANDLE_NOTIFY , + notif_handler, t,NULL );gatt_discover_char (t->attrib, t->svc_range->start, t->svc_range->end,NULL , configure_thermometer_cb, t); }
@@ -1045,6 +1078,11 @@ static void attio_disconnected_cb(gpointer user_data) t->attindid =0 ; } +if (t->attnotid >0 ) { +g_attrib_unregister (t->attrib, t->attnotid); + t->attnotid =0 ; + } +g_attrib_unref (t->attrib); t->attrib =NULL ; }
Signature · 1 line
1.7.7.2
Re: [PATCH 6/6] Notify intermediate measurements
Hi Santiago,
Quoted 14 lines · Santiago Carot-Nemesio
static void
recv_measurement(struct thermometer *t, struct measurement *msmt){
- GSList *l;
+ GSList *l, *ll;- if (
g_strcmp0(msmt->msmnt, "Intermediate")== 0) {
-DBG("Notification of intermediate measurement not implemented");
- return;
- }
+ if (g_strcmp0(msmt->msmnt, "Intermediate")== 0)
+ ll =t->iwatchers;
+ else
+ ll =t->fwatchers;
Quoted 4 lines
- for (l =
t->fwatchers; l; l =l->next)
+ for (l = ll; l; l =l->next)
update_watcher(l->data, msmt);
}
What about using g_slist_foreach() above? Also "ll" seems too generic, what about "wlist".
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Re: [PATCH 6/6] Notify intermediate measurements
Hi Anderson,
2011/11/9 Anderson Lizardo <[email protected]>:
Quoted 18 lines
Hi Santiago,
Quoted 14 lines · Santiago Carot-Nemesio
static void
recv_measurement(struct thermometer *t, struct measurement *msmt){
- GSList *l;
+ GSList *l, *ll;- if (
g_strcmp0(msmt->msmnt, "Intermediate")== 0) {
-DBG("Notification of intermediate measurement not implemented");
- return;
- }
+ if (g_strcmp0(msmt->msmnt, "Intermediate")== 0)
+ ll =t->iwatchers;
+ else
+ ll =t->fwatchers;
Quoted 7 lines
Quoted 4 lines
- for (l =
t->fwatchers; l; l =l->next)
+ for (l = ll; l; l =l->next)
update_watcher(l->data, msmt);
}What about using
g_slist_foreach()above? Also "ll" seems too generic, what about "wlist".
Ok, I'll prepare a new set of patches, but I would rather wait to get comments and advices to the question regarding to how we should manage GATT attribute indications.
Thank you very much for your comments.
Santiago
Quoted 7 lines
Regards,
--
Anderson Lizardo
Instituto Nokia de Tecnologia - INdT
Manaus - Brazil
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
In reply to Santiago Carot-NemesioHi Santiago,
thermometer/thermometer.c static gint cmp_char_uuid(gconstpointer a, gconstpointer b) · line 175
Quoted 10 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +10
-0+static gint cmp_char_val_handle (gconstpointer a,gconstpointer b) +{ + const struct characteristic *ch = a; + const uint16_t *handle = b; + + if (ch->attr.value_handle == *handle) + return 0; + + return -1; +}
Usually we implement the function above as:
return ch->attr.value_handle - *handle;
It will work exactly as your code.
thermometer/thermometer.c static GDBusSignalTable thermometer_signals[] = { · line 740
Quoted 13 lines
static void
ind_handler(const uint8_t *pdu, uint16_t len, gpointer user_data){thermometer/thermometer.c +10
-1-/* TODO: Process indication */ +struct thermometer *t = user_data; +const struct characteristic *ch; +uint8_t opdu[ATT_MAX_MTU ]; +uint16_t handle, olen; +GSList *l; + + if (len < 3) { + DBG("Bad pdu received"); + goto done; + }
Are you sure we should send a confirmation even if the PDU received is invalid? What if it is not even an indication (you only check below)?
Quoted 5 lines
+
+ if (pdu[0] !=ATT_OP_HANDLE_IND) {
+DBG("Not indication received");
+ return;
+ }
I suggest a more descriptive debug message here, something like:
DBG("Unexpected ATT opcode: 0x%02x", pdu[0]);
Quoted 5 lines
+
+ handle =att_get_u16(&pdu[1]);
+ l =g_slist_find_custom(t->chars, &handle, cmp_char_val_handle);
+ if (l == NULL)
+ goto done;
Again, should we send a confirmation to the thermometer even if the indication's handle does not match any characteristic value?
(note I didn't read the thermometer profile spec carefully yet. Not sure if it covers invalid PDUs.)
Quoted 13 lines
thermometer/thermometer.c +13
-0+ + ch = l->data; + if (g_strcmp0(ch->attr.uuid, TEMPERATURE_MEASUREMENT_UUID) == 0) + proc_measurement(t, pdu, len, TRUE); + else if (g_strcmp0(ch->attr.uuid, MEASUREMENT_INTERVAL_UUID) == 0) + proc_measurement_interval(t, pdu, len); + +done: + olen = enc_confirmation(opdu, sizeof(opdu)); + + if (olen > 0) + g_attrib_send(t->attrib, 0, opdu[0], opdu, olen, NULL, NULL, + NULL);
Quoted 1 line
}
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
Am 09.11.2011 13:00, schrieb Anderson Lizardo:
Quoted 17 lines
Hi Santiago,
thermometer/thermometer.c static gint cmp_char_uuid(gconstpointer a, gconstpointer b) · line 175
Quoted 10 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +10
-0+static gint cmp_char_val_handle (gconstpointer a,gconstpointer b) +{ + const struct characteristic *ch = a; + const uint16_t *handle = b; + + if (ch->attr.value_handle == *handle) + return 0; + + return -1; +}Usually we implement the function above as:
Quoted 3 lines
return
ch->attr.value_handle- *handle;It will work exactly as your code.
You can do it this way with signed integers but not with unsigned integers, unless you cast both to signed first. Still, the above code completely misses the +1 case.
HS
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
Hi Hendrik,
Quoted 20 lines · Hendrik Sattler
Am 09.11.2011 13:00, schrieb Anderson Lizardo:
Quoted 19 lines
Hi Santiago,
thermometer/thermometer.c static gint cmp_char_uuid(gconstpointer a, gconstpointer b) · line 175
Quoted 11 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +10
-0+static gint cmp_char_val_handle (gconstpointer a,gconstpointer b) +{ + const struct characteristic *ch = a; + const uint16_t *handle = b; + + if (ch->attr.value_handle == *handle) + return 0; + + return -1; +}Usually we implement the function above as:
Quoted 7 lines
Quoted 3 lines
return
ch->attr.value_handle- *handle;It will work exactly as your code.
You can do it this way with signed integers but not with unsigned integers, unless you cast both to signed first.
Still, the above code completely misses the +1 case.
The idea here is to return 0 if they are same or non zero if they are not same. The actual sign is not relevant because the comparison is for finding items, not sorting them (in this case).
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
Am 09.11.2011 14:30, schrieb Anderson Lizardo:
Quoted 28 lines
Hi Hendrik,
Quoted 24 lines · Hendrik Sattler
Am 09.11.2011 13:00, schrieb Anderson Lizardo:
Quoted 22 lines
Hi Santiago,
thermometer/thermometer.c static gint cmp_char_uuid(gconstpointer a, gconstpointer b) · line 175
Quoted 11 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +10
-0+static gint cmp_char_val_handle (gconstpointer a,gconstpointer b) +{ + const struct characteristic *ch = a; + const uint16_t *handle = b; + + if (ch->attr.value_handle == *handle) + return 0; + + return -1; +}Usually we implement the function above as:
return
ch->attr.value_handle- *handle;It will work exactly as your code.
Quoted 7 lines
Quoted 3 lines
You can do it this way with signed integers but not with unsigned integers, unless you cast both to signed first.
Still, the above code completely misses the +1 case.The idea here is to return 0 if they are same or non zero if they are not same. The actual sign is not relevant because the comparison is for finding items, not sorting them (in this case).
Kind of a lazy approach, no?
Ah well...
HS
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
Hi Hendrik,
Quoted 6 lines · Hendrik Sattler
Quoted 3 lines
The idea here is to return 0 if they are same or non zero if they are not same. The actual sign is not relevant because the comparison is for finding items, not sorting them (in this case).
Kind of a lazy approach, no?
Ah well...
I agree with you, and maybe it is even risky if soneone reuses these functions for list sorting as well without extending them, but this is the current procedure on BlueZ as a whole:
$ grep -R 'return.*handle - ' src/ attrib/ src/sdpd-database.c: return rec1->handle - rec2->handle; src/sdpd-database.c: return rec1->handle - rec2->handle; src/device.c: return r1->handle - r2->handle; src/attrib-server.c: return attrib->handle - handle; src/attrib-server.c: return attrib1->handle - attrib2->handle; attrib/client.c: return chr->handle - handle;
(all these handles are unsigned.)
Note that I'm not defending the current usage, but then it would need be "fixed" in a separate commit to fix all cases and maintain consistency.
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
In reply to Anderson LizardoHi Anderson,
Please, see coments below,
2011/11/9 Anderson Lizardo <[email protected]>:
Quoted 17 lines
Hi Santiago,
thermometer/thermometer.c static gint cmp_char_uuid(gconstpointer a, gconstpointer b) · line 175
Quoted 10 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +10
-0+static gint cmp_char_val_handle (gconstpointer a,gconstpointer b) +{ + const struct characteristic *ch = a; + const uint16_t *handle = b; + + if (ch->attr.value_handle == *handle) + return 0; + + return -1; +}Usually we implement the function above as:
Quoted 4 lines
return
ch->attr.value_handle- *handle;It will work exactly as your code.
ok, that's only a nitpick.
Quoted 14 lines
Quoted 5 lines
static void
ind_handler(const uint8_t *pdu, uint16_t len, gpointer user_data){
- /* TODO: Process indication */
+ struct thermometer *t =user_data;
+ const struct characteristic *ch;Quoted 8 lines
+
uint8_topdu[ATT_MAX_MTU];
+uint16_thandle, olen;
+ GSList *l;
+
+ if (len < 3) {
+DBG("Bad pdu received");
+ goto done;
+ }
Quoted 2 lines
Are you sure we should send a confirmation even if the PDU received is invalid? What if it is not even an indication (you only check below)?
This callback is supposed only to manage indications not notifications:
in the code:
...
g_attrib_register(t->attrib, ATT_OP_HANDLE_IND,
ind_handler, t, NULL);
Shall I expect another kind of notifications even if I have not indicated it when I registered the callback?
Quoted 11 lines
Quoted 6 lines
+
+ if (pdu[0] !=ATT_OP_HANDLE_IND) {
+DBG("Not indication received");
+ return;
+ }I suggest a more descriptive debug message here, something like:
DBG("Unexpected ATT opcode: 0x%02x", pdu[0]);
OK, no problem.
Quoted 6 lines
Quoted 5 lines
+
+ handle =att_get_u16(&pdu[1]);
+ l =g_slist_find_custom(t->chars, &handle, cmp_char_val_handle);
+ if (l == NULL)
+ goto done;
Quoted 6 lines
Again, should we send a confirmation to the thermometer even if the indication's handle does not match any characteristic value?
(note I didn't read the thermometer profile spec carefully yet. Not sure if it covers invalid PDUs.)
As far as I know, the thermometer spec is not focused in such kind of GATT details, so I guess it will depend of the implementation. If we don't send a reply to that indication the remote side will close the connection when the timeout expired. So here is the question: what would we rather do, to keep the connection alive or to let the remote side to close it?
Waiting comments.
Regards
Santiago
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
Hi Santiago,
Quoted 17 lines · Santiago Carot
Quoted 14 lines
Quoted 5 lines
static void
ind_handler(const uint8_t *pdu, uint16_t len, gpointer user_data){
- /* TODO: Process indication */
+ struct thermometer *t =user_data;
+ const struct characteristic *ch;Quoted 8 lines
+
uint8_topdu[ATT_MAX_MTU];
+uint16_thandle, olen;
+ GSList *l;
+
+ if (len < 3) {
+DBG("Bad pdu received");
+ goto done;
+ }Quoted 2 lines
Are you sure we should send a confirmation even if the PDU received is invalid? What if it is not even an indication (you only check below)?
Quoted 8 lines
This callback is supposed only to manage indications not notifications:
in the code:
...
g_attrib_register(t->attrib,ATT_OP_HANDLE_IND,
ind_handler, t, NULL);Shall I expect another kind of notifications even if I have not indicated it when I registered the callback?
I only made this comment because you do this check on the function:
+ if (pdu[0] != ATT_OP_HANDLE_IND) {
+ DBG("Not indication received");
+ return;
+ }
I think you can simply drop this check, as you mentioned it will only be called for indications.
About the PDU size check, I think it is important to have it (to avoid memory corruption on invalid PDU), but then the peer device is bogus, so I think you should not send a confirmation for it, because you did not receive a valid indication in the first place.
Quoted 13 lines
Quoted 6 lines
Quoted 5 lines
+
+ handle =att_get_u16(&pdu[1]);
+ l =g_slist_find_custom(t->chars, &handle, cmp_char_val_handle);
+ if (l == NULL)
+ goto done;Quoted 6 lines
Again, should we send a confirmation to the thermometer even if the indication's handle does not match any characteristic value?
(note I didn't read the thermometer profile spec carefully yet. Not sure if it covers invalid PDUs.)
Quoted 6 lines
As far as I know, the thermometer spec is not focused in such kind of GATT details, so I guess it will depend of the implementation. If we don't send a reply to that indication the remote side will close the connection when the timeout expired. So here is the question: what would we rather do, to keep the connection alive or to let the remote side to close it?
I believe that in general, if the peer device sends a bogus indication (or if the communication channel was corrupted somehow), we should *not* confirm it. I see confirmations as an "ack" that the indication was received, processed and validated by BlueZ. If it is somehow invalid (PDU size incorrect, invalid handle), we should not confirm it.
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Re: [PATCH 1/6] Manage GATT attribute indications in handle callback.
Hi Anderson,
2011/11/9 Anderson Lizardo <[email protected]>:
Quoted 64 lines
Hi Santiago,
Quoted 17 lines · Santiago Carot
Quoted 14 lines
Quoted 5 lines
static void
ind_handler(const uint8_t *pdu, uint16_t len, gpointer user_data){
- /* TODO: Process indication */
+ struct thermometer *t =user_data;
+ const struct characteristic *ch;Quoted 8 lines
+
uint8_topdu[ATT_MAX_MTU];
+uint16_thandle, olen;
+ GSList *l;
+
+ if (len < 3) {
+DBG("Bad pdu received");
+ goto done;
+ }Quoted 2 lines
Are you sure we should send a confirmation even if the PDU received is invalid? What if it is not even an indication (you only check below)?
Quoted 8 lines
This callback is supposed only to manage indications not notifications:
in the code:
...
g_attrib_register(t->attrib,ATT_OP_HANDLE_IND,
ind_handler, t, NULL);Shall I expect another kind of notifications even if I have not indicated it when I registered the callback?
I only made this comment because you do this check on the function:
+ if (pdu[0] !=
ATT_OP_HANDLE_IND) {
+DBG("Not indication received");
+ return;
+ }I think you can simply drop this check, as you mentioned it will only be called for indications.
About the PDU size check, I think it is important to have it (to avoid memory corruption on invalid PDU), but then the peer device is bogus, so I think you should not send a confirmation for it, because you did not receive a valid indication in the first place.
Quoted 13 lines
Quoted 6 lines
Quoted 5 lines
+
+ handle =att_get_u16(&pdu[1]);
+ l =g_slist_find_custom(t->chars, &handle, cmp_char_val_handle);
+ if (l == NULL)
+ goto done;Quoted 6 lines
Again, should we send a confirmation to the thermometer even if the indication's handle does not match any characteristic value?
(note I didn't read the thermometer profile spec carefully yet. Not sure if it covers invalid PDUs.)
Quoted 6 lines
As far as I know, the thermometer spec is not focused in such kind of GATT details, so I guess it will depend of the implementation. If we don't send a reply to that indication the remote side will close the connection when the timeout expired. So here is the question: what would we rather do, to keep the connection alive or to let the remote side to close it?
Quoted 6 lines
I believe that in general, if the peer device sends a bogus indication (or if the communication channel was corrupted somehow), we should *not* confirm it. I see confirmations as an "ack" that the indication was received, processed and validated by BlueZ. If it is somehow invalid (PDU size incorrect, invalid handle), we should not confirm it.
It makes sense for me, I'll send a new set of patches with the changes you have suggested.
Thanks.
Hi Santiago,
Quoted 3 lines · Santiago Carot-Nemesio
This is a new set of patches to enhance thermometer plugin fuctionality. These patches enable watchers to receiave final/intermediate measurements from thermometers devices.
Out of curiosity, with this latest series, will we be able to use LE Health Thermometers? Or do you still have pending items?
It would be nice if you share your TODO list regarding this profile, or current limitations (if any), on each series you send.
Quoted 6 lines
[PATCH 1/6] Manage GATT attribute indications in handle callback. [PATCH 2/6] Parse final measurement indication
[PATCH 3/6] Add org.bluez.ThermometerWatcher interface to default [PATCH 4/6] Implement EnableIntermediateMeasurement D-Bus method [PATCH 5/6] Implement DisableIntermediateMeasurement D-Bus method [PATCH 6/6] Notify intermediate measurements
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Hi Anderson
2011/11/9 Anderson Lizardo <[email protected]>:
Quoted 11 lines
Hi Santiago,
Quoted 3 lines · Santiago Carot-Nemesio
This is a new set of patches to enhance thermometer plugin fuctionality. These patches enable watchers to receiave final/intermediate measurements from thermometers devices.
Out of curiosity, with this latest series, will we be able to use LE Health Thermometers? Or do you still have pending items?
Yes, of course, with these set of patches you should able to use a Thermometer.
Quoted 2 lines
It would be nice if you share your TODO list regarding this profile, or current limitations (if any), on each series you send.
Ok,
At present, I'm working on this repository:
https://github.com/sancane/BlueZ
There you will able to see the current status of the plugin implementation, there you can also find some pending patches wich I've not yet submited to the list and so on.
On the other hand, there is nothing left more in my TODO list than finishing the HTP implementation :-P
Regards.
Quoted 14 lines
Quoted 7 lines
[PATCH 1/6] Manage GATT attribute indications in handle callback. [PATCH 2/6] Parse final measurement indication
[PATCH 3/6] Add org.bluez.ThermometerWatcher interface to default [PATCH 4/6] Implement EnableIntermediateMeasurement D-Bus method [PATCH 5/6] Implement DisableIntermediateMeasurement D-Bus method [PATCH 6/6] Notify intermediate measurementsRegards,
--
Anderson Lizardo
Instituto Nokia de Tecnologia - INdT
Manaus - Brazil