power_supply: charger-manager: Clean up for better readability
PATCH 1/1 power_supply: charger-manager: Clean up for better readability
This patch includes below changes:
* Some code change for better readability.
* Current code in probe already ensures desc->charger_regulators is not NULL. No need to check if it is NULL or not before calling regulator_bulk_free().
* Use dev_get_drvdata() in cm_suspend_prepare() and cm_suspend_complete()
--- drivers/power/charger-manager.c | 61 ++++++++++++++++---------------------- 1 files changed, 26 insertions(+), 35 deletions(-)
drivers/power/charger-manager.c +26 -35
@@ -134,12 +134,11 @@ static int get_batt_uV(struct charger_manager *cm, int *uV)union power_supply_propval val;int ret; -if (cm->fuel_gauge) - ret = cm->fuel_gauge->get_property (cm->fuel_gauge, -POWER_SUPPLY_PROP_VOLTAGE_NOW , &val); -else +if (!cm->fuel_gauge)return -ENODEV ; + ret = cm->fuel_gauge->get_property (cm->fuel_gauge, +POWER_SUPPLY_PROP_VOLTAGE_NOW , &val);if (ret)return ret;
@@ -245,9 +244,7 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)struct charger_desc *desc = cm->desc;/* Ignore if it's redundent command */ -if (enable && cm->charger_enabled) -return 0 ; -if (!enable && !cm->charger_enabled) +if (enable == cm->charger_enabled)return 0 ;if (enable) {
@@ -309,9 +306,7 @@ static void uevent_notify(struct charger_manager *cm, const char *event)if (!strncmp (env_str_save, event,UEVENT_BUF_SIZE ))return ;/* Duplicated. */ -else -strncpy (env_str_save, event,UEVENT_BUF_SIZE ); - +strncpy (env_str_save, event,UEVENT_BUF_SIZE );return ; }
@@ -387,8 +382,10 @@ static bool cm_monitor(void)mutex_lock (&cm_list_mtx); -list_for_each_entry (cm, &cm_list, entry) - stop = stop ||_cm_monitor (cm); +list_for_each_entry (cm, &cm_list, entry) { +if (_cm_monitor (cm)) + stop = true; + }mutex_unlock (&cm_list_mtx);
@@ -697,8 +694,10 @@ bool cm_suspend_again(void)mutex_lock (&cm_list_mtx);list_for_each_entry (cm, &cm_list, entry) {if (cm->status_save_ext_pwr_inserted !=is_ext_pwr_online (cm) || - cm->status_save_batt !=is_batt_present (cm)) + cm->status_save_batt !=is_batt_present (cm)) { ret = false; +break ; + } }mutex_unlock (&cm_list_mtx);
@@ -855,11 +854,10 @@ static int charger_manager_probe(struct platform_device *pdev)platform_set_drvdata (pdev, cm); -memcpy (&cm->charger_psy, &psy_default, -sizeof (psy_default)); +memcpy (&cm->charger_psy, &psy_default,sizeof (psy_default)); +if (!desc->psy_name) { -strncpy (cm->psy_name_buf, psy_default.name, -PSY_NAME_MAX ); +strncpy (cm->psy_name_buf, psy_default.name,PSY_NAME_MAX ); }else {strncpy (cm->psy_name_buf, desc->psy_name,PSY_NAME_MAX ); }
@@ -894,15 +892,15 @@ static int charger_manager_probe(struct platform_device *pdev)POWER_SUPPLY_PROP_CURRENT_NOW ; cm->charger_psy.num_properties++; } -if (!desc->measure_battery_temp) { - cm->charger_psy.properties[cm->charger_psy.num_properties] = -POWER_SUPPLY_PROP_TEMP_AMBIENT ; - cm->charger_psy.num_properties++; - } +if (desc->measure_battery_temp) { cm->charger_psy.properties[cm->charger_psy.num_properties] =POWER_SUPPLY_PROP_TEMP ; cm->charger_psy.num_properties++; + }else { + cm->charger_psy.properties[cm->charger_psy.num_properties] = +POWER_SUPPLY_PROP_TEMP_AMBIENT ; + cm->charger_psy.num_properties++; } ret =power_supply_register (NULL , &cm->charger_psy);
@@ -933,9 +931,8 @@ static int charger_manager_probe(struct platform_device *pdev)return 0 ; err_chg_enable: -if (desc->charger_regulators) -regulator_bulk_free (desc->num_charger_regulators, - desc->charger_regulators); +regulator_bulk_free (desc->num_charger_regulators, + desc->charger_regulators); err_bulk_get:power_supply_unregister (&cm->charger_psy); err_register:
@@ -961,10 +958,8 @@ static int __devexit charger_manager_remove(struct platform_device *pdev)list_del (&cm->entry);mutex_unlock (&cm_list_mtx); -if (desc->charger_regulators) -regulator_bulk_free (desc->num_charger_regulators, - desc->charger_regulators); - +regulator_bulk_free (desc->num_charger_regulators, + desc->charger_regulators);power_supply_unregister (&cm->charger_psy);kfree (cm->charger_psy.properties);kfree (cm->charger_stat);
@@ -982,9 +977,7 @@ MODULE_DEVICE_TABLE(platform, charger_manager_id);static int cm_suspend_prepare (struct device *dev) { - struct platform_device *pdev = container_of(dev, struct platform_device, - dev); -struct charger_manager *cm =platform_get_drvdata (pdev); +struct charger_manager *cm =dev_get_drvdata (dev);if (!cm_suspended) {if (rtc_dev) {
@@ -1020,9 +1013,7 @@ static int cm_suspend_prepare(struct device *dev)static void cm_suspend_complete (struct device *dev) { - struct platform_device *pdev = container_of(dev, struct platform_device, - dev); -struct charger_manager *cm =platform_get_drvdata (pdev); +struct charger_manager *cm =dev_get_drvdata (dev);if (cm_suspended) {if (rtc_dev) {
Signature · 1 line
1.7.5.4
Anton Vorontsov
AppliedQuoted 9 lines · Axel Lin
This patch includes below changes:
* Some code change for better readability.
* Current code in probe already ensuresdesc->charger_regulatorsis not NULL. No need to check if it is NULL or not before callingregulator_bulk_free().
* Usedev_get_drvdata()incm_suspend_prepare()andcm_suspend_complete()Signed-off-by Axel Lin <[email protected]>---
Applied, thanks a lot!
FWIW, I also applied the following patch:
commit f304f0a31442f4c8b98208acedc3da2f6c60a771
Author: Anton Vorontsov <[email protected]> Date: Thu Mar 15 21:01:28 2012 +0400
charger-manager: Simplify charger_get_property(), get rid of a warning
This patch fixes the following warning and makes the code a little bit more simpler:
CC drivers/power/charger-manager.o
charger-manager.c: In function 'charger_get_property':
charger-manager.c:429:15: warning: 'i' may be used uninitialized in this function [-Wuninitialized]
drivers/power/charger-manager.c +3 -3
@@ -399,7 +399,8 @@ static int charger_get_property(struct power_supply *psy,struct charger_manager *cm =container_of (psy, struct charger_manager, charger_psy);struct charger_desc *desc = cm->desc; -int i, ret =0 , uV; +int ret =0 ; +int uV;switch (psp) {case POWER_SUPPLY_PROP_STATUS :
@@ -425,8 +426,7 @@ static int charger_get_property(struct power_supply *psy, val->intval =0 ;break ;case POWER_SUPPLY_PROP_VOLTAGE_NOW : - ret =get_batt_uV (cm, &i); - val->intval = i; + ret =get_batt_uV (cm, &val->intval);break ;case POWER_SUPPLY_PROP_CURRENT_NOW : ret = cm->fuel_gauge->get_property(cm->fuel_gauge,