Hi,
This is version 3 of the patch-set that adds support for the latest pressure sensors from Bosch Sensortec.
Changes from last version:
- Dropped the platform data in favor of devicetree properties.
- Use regmap as communication layer.
- Changed Kconfig logic.
- Keep the original bmp085 file name.
- Use EXPORT_SYMBOL_GPL.
--
Best regards,
Eric
Eric Andersson (3):
misc: clean up bmp085 driver
misc: bmp085: add device tree properties
misc: add support for bmp18x chips to the bmp085 driver
Documentation/devicetree/bindings/misc/bmp085.txt | 20 ++ drivers/misc/Kconfig | 26 ++- drivers/misc/Makefile | 2 + drivers/misc/bmp085-i2c.c | 87 +++++ drivers/misc/bmp085-spi.c | 89 +++++ drivers/misc/bmp085.c | 356 +++++++++++---------- drivers/misc/bmp085.h | 33 ++ 7 files changed, 434 insertions(+), 179 deletions(-) create mode 100644 Documentation/devicetree/bindings/misc/bmp085.txt create mode 100644 drivers/misc/bmp085-i2c.c create mode 100644 drivers/misc/bmp085-spi.c create mode 100644 drivers/misc/bmp085.h
Signature · 1 line
1.7.3.4
PATCH v3 1/3 misc: clean up bmp085 driver
This patch includes various cleaning of the bmp085 driver including:
- Whitespaces and alignment fixes
- Minor typos
- Consistency fixes
--- drivers/misc/bmp085.c | 204 ++++++++++++++++++++++++------------------------ 1 files changed, 102 insertions(+), 102 deletions(-)
drivers/misc/bmp085.c +102 -102
@@ -1,62 +1,63 @@/* Copyright (c) 2010 Christoph Mair <[email protected]> - -This driver supports the bmp085 digital barometric pressure -and temperature sensor from Bosch Sensortec. The datasheet -is available from their website: -http://www.bosch-sensortec.com/content/language1/downloads/BST-BMP085-DS000-05.pdf - -A pressure measurement is issued by reading from pressure0_input. -The return value ranges from 30000 to 110000 pascal with a resulution -of 1 pascal (0.01 millibar) which enables measurements from 9000m above -to 500m below sea level. - -The temperature can be read from temp0_input. Values range from --400 to 850 representing the ambient temperature in degree celsius -multiplied by 10.The resolution is 0.1 celsius. - -Because ambient pressure is temperature dependent, a temperature -measurement will be executed automatically even if the user is reading -from pressure0_input. This happens if the last temperature measurement -has been executed more then one second ago. - -To decrease RMS noise from pressure measurements, the bmp085 can -autonomously calculate the average of up to eight samples. This is -set up by writing to the oversampling sysfs file. Accepted values -are 0, 1, 2 and 3. 2^x when x is the value written to this file -specifies the number of samples used to calculate the ambient pressure. -RMS noise is specified with six pascal (without averaging) and decreases -down to 3 pascal when using an oversampling setting of 3. - -This program is free software; you can redistribute it and/or modify -it under the terms of the GNU General Public License as published by -the Free Software Foundation; either version 2 of the License, or -(at your option) any later version. - -This program is distributed in the hope that it will be useful, -but WITHOUT ANY WARRANTY; without even the implied warranty of -MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the -GNU General Public License for more details. - -You should have received a copy of the GNU General Public License -along with this program; if not, write to the Free Software -Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA. -*/ - +* Copyright (c) 2012 Bosch Sensortec GmbH +* Copyright (c) 2012 Unixphere AB +* +* This driver supports the bmp085 digital barometric pressure +* and temperature sensor from Bosch Sensortec. The datasheet +* is available from their website: +* http://www.bosch-sensortec.com/content/language1/downloads/BST-BMP085-DS000-05.pdf +* +* A pressure measurement is issued by reading from pressure0_input. +* The return value ranges from 30000 to 110000 pascal with a resulution +* of 1 pascal (0.01 millibar) which enables measurements from 9000m above +* to 500m below sea level. +* +* The temperature can be read from temp0_input. Values range from +* -400 to 850 representing the ambient temperature in degree celsius +* multiplied by 10.The resolution is 0.1 celsius. +* +* Because ambient pressure is temperature dependent, a temperature +* measurement will be executed automatically even if the user is reading +* from pressure0_input. This happens if the last temperature measurement +* has been executed more then one second ago. +* +* To decrease RMS noise from pressure measurements, the bmp085 can +* autonomously calculate the average of up to eight samples. This is +* set up by writing to the oversampling sysfs file. Accepted values +* are 0, 1, 2 and 3. 2^x when x is the value written to this file +* specifies the number of samples used to calculate the ambient pressure. +* RMS noise is specified with six pascal (without averaging) and decreases +* down to 3 pascal when using an oversampling setting of 3. +* +* This program is free software; you can redistribute it and/or modify +* it under the terms of the GNU General Public License as published by +* the Free Software Foundation; either version 2 of the License, or +* (at your option) any later version. +* +* This program is distributed in the hope that it will be useful, +* but WITHOUT ANY WARRANTY; without even the implied warranty of +* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the +* GNU General Public License for more details. +* +* You should have received a copy of the GNU General Public License +* along with this program; if not, write to the Free Software +* Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA. +*/ #include <linux/module.h> +#include <linux/device.h> #include <linux/init.h> #include <linux/i2c.h> #include <linux/slab.h> #include <linux/delay.h> - +#define BMP085_NAME "bmp085"#define BMP085_I2C_ADDRESS 0x77#define BMP085_CHIP_ID 0x55#define BMP085_CALIBRATION_DATA_START 0xAA#define BMP085_CALIBRATION_DATA_LENGTH 11/* 16 bit values */ #define BMP085_CHIP_ID_REG 0xD0 -#define BMP085_VERSION_REG 0xD1#define BMP085_CTRL_REG 0xF4#define BMP085_TEMP_MEASUREMENT 0x2E#define BMP085_PRESSURE_MEASUREMENT 0x34
@@ -65,9 +66,6 @@#define BMP085_CONVERSION_REGISTER_XLSB 0xF8#define BMP085_TEMP_CONVERSION_TIME 5 -#define BMP085_CLIENT_NAME "bmp085" - -static const unsigned short normal_i2c[] = {BMP085_I2C_ADDRESS ,I2C_CLIENT_END };
@@ -78,20 +76,18 @@ struct bmp085_calibration_data {s16 MB ,MC ,MD ; }; - -/* Each client has this additional data */ struct bmp085_data { -struct i2c_client *client; -struct mutex lock; -struct bmp085_calibration_data calibration; -u32 raw_temperature; -u32 raw_pressure; -unsigned char oversampling_setting; +struct i2c_client *client; +struct mutex lock; +struct bmp085_calibration_data calibration; +u8 oversampling_setting; +u32 raw_temperature; +u32 raw_pressure; +u32 temp_measurement_period;unsigned long last_temp_measurement; -s32 b6;/* calculated temperature correction coefficient */ +s32 b6;/* calculated temperature correction coefficient */ }; -static s32 bmp085_read_calibration_data (struct i2c_client *client) {u16 tmp[BMP085_CALIBRATION_DATA_LENGTH ];
@@ -99,12 +95,12 @@ static s32 bmp085_read_calibration_data(struct i2c_client *client)struct bmp085_calibration_data *cali = &(data->calibration);s32 status =i2c_smbus_read_i2c_block_data (client,BMP085_CALIBRATION_DATA_START , -BMP085_CALIBRATION_DATA_LENGTH *sizeof (u16), + (BMP085_CALIBRATION_DATA_LENGTH <<1 ), (u8 *)tmp);if (status <0 )return status; -if (status !=BMP085_CALIBRATION_DATA_LENGTH *sizeof (u16)) +if (status != (BMP085_CALIBRATION_DATA_LENGTH <<1 ))return -EIO ; cali->AC1 =be16_to_cpu (tmp[0 ]);
@@ -121,7 +117,6 @@ static s32 bmp085_read_calibration_data(struct i2c_client *client)return 0 ; } -static s32 bmp085_update_raw_temperature (struct bmp085_data *data) {u16 tmp;
@@ -130,7 +125,7 @@ static s32 bmp085_update_raw_temperature(struct bmp085_data *data)mutex_lock (&data->lock); status =i2c_smbus_write_byte_data (data->client,BMP085_CTRL_REG ,BMP085_TEMP_MEASUREMENT ); -if (status !=0 ) { +if (status <0 ) {dev_err (&data->client->dev,"Error while requesting temperature measurement.\n" ); goto exit;
@@ -163,8 +158,9 @@ static s32 bmp085_update_raw_pressure(struct bmp085_data *data)mutex_lock (&data->lock); status =i2c_smbus_write_byte_data (data->client,BMP085_CTRL_REG , -BMP085_PRESSURE_MEASUREMENT + (data->oversampling_setting<<6 )); -if (status !=0 ) { +BMP085_PRESSURE_MEASUREMENT + + (data->oversampling_setting <<6 )); +if (status <0 ) {dev_err (&data->client->dev,"Error while requesting pressure measurement.\n" ); goto exit;
@@ -193,7 +189,6 @@ exit:return status; } -/* * This function starts the temperature measurement and returns the value * in tenth of a degree celsius.
@@ -205,7 +200,7 @@ static s32 bmp085_get_temperature(struct bmp085_data *data, int *temperature)int status; status =bmp085_update_raw_temperature (data); -if (status !=0 ) +if (status <0 ) goto exit; x1 = ((data->raw_temperature - cali->AC6) * cali->AC5) >>15 ;
@@ -222,8 +217,10 @@ exit:/* * This function starts the pressure measurement and returns the value * in millibar. Since the pressure depends on the ambient temperature, -* a temperature measurement is executed if the last known value is older -* than one second. +* a temperature measurement is executed according to the given temperature +* measurememt period (default is 1 sec boundary). This period could vary +* and needs to be adjusted according to the sensor environment, i.e. if big +* temperature variations then the temperature needs to be read out often. */ static s32 bmp085_get_pressure (struct bmp085_data *data,int *pressure) {
@@ -234,16 +231,16 @@ static s32 bmp085_get_pressure(struct bmp085_data *data, int *pressure)int status;/* alt least every second force an update of the ambient temperature */ -if (data->last_temp_measurement ==0 || -time_is_before_jiffies (data->last_temp_measurement +1 *HZ )) { +if ((data->last_temp_measurement ==0 ) || +time_is_before_jiffies (data->last_temp_measurement +1 *HZ )) { status =bmp085_get_temperature (data,NULL ); -if (status !=0 ) - goto exit; +if (status <0 ) +return status; } status =bmp085_update_raw_pressure (data); -if (status !=0 ) - goto exit; +if (status <0 ) +return status; x1 = (data->b6 * data->b6) >>12 ; x1 *= cali->B2;
@@ -274,15 +271,14 @@ static s32 bmp085_get_pressure(struct bmp085_data *data, int *pressure) *pressure = p; -exit: -return status; +return 0 ; }/* * This function sets the chip-internal oversampling. Valid values are 0..3. * The chip will use 2^oversampling samples for internal averaging. * This influences the measurement time and the accuracy; larger values -* increase both. The datasheet gives on overview on how measurement time, +* increase both. The datasheet gives an overview on how measurement time, * accuracy and noise correlate. */ static void bmp085_set_oversampling(struct bmp085_data *data,
@@ -309,12 +305,16 @@ static ssize_t set_oversampling(struct device *dev,struct i2c_client *client =to_i2c_client (dev);struct bmp085_data *data =i2c_get_clientdata (client);unsigned long oversampling; -int success =strict_strtoul (buf,10 , &oversampling); -if (success ==0 ) { +int err =kstrtoul (buf,10 , &oversampling); + +if (err ==0 ) { +mutex_lock (&data->lock);bmp085_set_oversampling (data, oversampling); +mutex_unlock (&data->lock);return count; } -return success; + +return err; } static ssize_t show_oversampling(struct device *dev,
@@ -322,6 +322,7 @@ static ssize_t show_oversampling(struct device *dev, {struct i2c_client *client =to_i2c_client (dev);struct bmp085_data *data =i2c_get_clientdata (client); +return sprintf (buf,"%u\n" ,bmp085_get_oversampling (data)); } static DEVICE_ATTR(oversampling, S_IWUSR | S_IRUGO,
@@ -337,7 +338,7 @@ static ssize_t show_temperature(struct device *dev,struct bmp085_data *data =i2c_get_clientdata (client); status =bmp085_get_temperature (data, &temperature); -if (status !=0 ) +if (status <0 )return status;else return sprintf (buf,"%d\n" , temperature);
@@ -354,7 +355,7 @@ static ssize_t show_pressure(struct device *dev,struct bmp085_data *data =i2c_get_clientdata (client); status =bmp085_get_pressure (data, &pressure); -if (status !=0 ) +if (status <0 )return status;else return sprintf (buf,"%d\n" , pressure);
@@ -386,25 +387,23 @@ static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info)static int bmp085_init_client (struct i2c_client *client) { -unsigned char version; -int status;struct bmp085_data *data =i2c_get_clientdata (client); +int status =bmp085_read_calibration_data (client); + +if (status <0 ) +return status; + data->client = client; - status =bmp085_read_calibration_data (client); -if (status !=0 ) - goto exit; - version =i2c_smbus_read_byte_data (client,BMP085_VERSION_REG ); data->last_temp_measurement =0 ; + data->temp_measurement_period =1 *HZ ; data->oversampling_setting =3 ;mutex_init (&data->lock); -dev_info (&data->client->dev,"BMP085 ver. %d.%d found.\n" , - (version &0x0F ), (version &0xF0 ) >>4 ); -exit: -return status; + +return 0 ; }static int __devinit bmp085_probe (struct i2c_client *client, -const struct i2c_device_id *id) +const struct i2c_device_id *id) {struct bmp085_data *data;int err =0 ;
@@ -415,14 +414,11 @@ static int __devinit bmp085_probe(struct i2c_client *client, goto exit; } -/* default settings after POR */ - data->oversampling_setting =0x00 ; -i2c_set_clientdata (client, data);/* Initialize the BMP085 chip */ err =bmp085_init_client (client); -if (err !=0 ) +if (err <0 ) goto exit_free;/* Register sysfs hooks */
@@ -430,8 +426,9 @@ static int __devinit bmp085_probe(struct i2c_client *client,if (err) goto exit_free; -dev_info (&data->client->dev,"Successfully initialized bmp085!\n" ); - goto exit; +dev_info (&client->dev,"Succesfully initialized %s!\n" ,BMP085_NAME ); + +return 0 ; exit_free:kfree (data);
@@ -441,13 +438,16 @@ exit: static int __devexit bmp085_remove(struct i2c_client *client) { +struct bmp085_data *data =i2c_get_clientdata (client); +sysfs_remove_group (&client->dev.kobj, &bmp085_attr_group); -kfree (i2c_get_clientdata (client)); +kfree (data); +return 0 ; }static const struct i2c_device_id bmp085_id[] = { - {"bmp085" ,0 }, + {BMP085_NAME ,0 }, { } };MODULE_DEVICE_TABLE (i2c, bmp085_id);
@@ -455,7 +455,7 @@ MODULE_DEVICE_TABLE(i2c, bmp085_id);static struct i2c_driver bmp085_driver = { .driver = { .owner =THIS_MODULE , - .name ="bmp085" + .name =BMP085_NAME }, .id_table = bmp085_id, .probe = bmp085_probe,
Signature · 1 line
1.7.3.4
Re: [PATCHv3 1/3] misc: clean up bmp085 driver
Quoted 4 lines · Eric Andersson
This patch includes various cleaning of the bmp085 driver including:
- Whitespaces and alignment fixes
- Minor typos
- Consistency fixes
just some more trivial things:
drivers/misc/bmp085.c
Quoted 1 line
drivers/misc/bmp085.c +0
-0
[]
drivers/misc/bmp085.c exit: · line 221
Quoted 8 lines
drivers/misc/bmp085.c +2
-2@@ -222,8 +217,10 @@ exit:/* * This function starts the pressure measurement and returns the value * in millibar. Since the pressure depends on the ambient temperature, -* a temperature measurement is executed if the last known value is older -* than one second. +* a temperature measurement is executed according to the given temperature +* measurememt period (default is 1 sec boundary). This period could vary
typo: measurement
drivers/misc/bmp085.c static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info) · line 388
Quoted 6 lines
drivers/misc/bmp085.c +2
-0+* and needs to be adjusted according to the sensor environment, i.e. if big +* temperature variations then the temperature needs to be read out often. @@ -386,25 +387,23 @@ static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info)static int bmp085_init_client (struct i2c_client *client)
[]
drivers/misc/bmp085.c static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info) · line 401
Quoted 2 lines
drivers/misc/bmp085.c +0
-2-dev_info (&data->client->dev,"BMP085 ver. %d.%d found.\n" , - (version &0x0F ), (version &0xF0 ) >>4 );
Why remove the "version" output?
[]
drivers/misc/bmp085.c static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info) · line 406
Quoted 3 lines
drivers/misc/bmp085.c +1
-1static int __devinit bmp085_probe (struct i2c_client *client, -const struct i2c_device_id *id) +const struct i2c_device_id *id)
[]
drivers/misc/bmp085.c static int __devinit bmp085_probe(struct i2c_client *client, · line 429
Quoted 7 lines
drivers/misc/bmp085.c +1
-2@@ -430,8 +426,9 @@ static int __devinit bmp085_probe(struct i2c_client *client,if (err) goto exit_free; -dev_info (&data->client->dev,"Successfully initialized bmp085!\n" ); - goto exit; +dev_info (&client->dev,"Succesfully initialized %s!\n" ,BMP085_NAME );
typo: successfully
Re: [PATCHv3 1/3] misc: clean up bmp085 driver
Hi Joe,
Quoted 24 lines · Joe Perches
Quoted 4 lines · Eric Andersson
This patch includes various cleaning of the bmp085 driver including:
- Whitespaces and alignment fixes
- Minor typos
- Consistency fixesjust some more trivial things:
drivers/misc/bmp085.c
Quoted 1 line
drivers/misc/bmp085.c +0
-0[]
drivers/misc/bmp085.c exit: · line 221
Quoted 8 lines
drivers/misc/bmp085.c +2
-2@@ -222,8 +217,10 @@ exit:/* * This function starts the pressure measurement and returns the value * in millibar. Since the pressure depends on the ambient temperature, -* a temperature measurement is executed if the last known value is older -* than one second. +* a temperature measurement is executed according to the given temperature +* measurememt period (default is 1 sec boundary). This period could vary typo: measurement
Quoted 2 lines
drivers/misc/bmp085.c +2
-0+* and needs to be adjusted according to the sensor environment, i.e. if big +* temperature variations then the temperature needs to be read out often.
Quoted 8 lines
drivers/misc/bmp085.c static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info) · line 388
Quoted 3 lines
drivers/misc/bmp085.c +0
-0@@ -386,25 +387,23 @@ static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info)static int bmp085_init_client (struct i2c_client *client)[]
drivers/misc/bmp085.c static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info) · line 401
Quoted 2 lines
drivers/misc/bmp085.c +0
-2-dev_info (&data->client->dev,"BMP085 ver. %d.%d found.\n" , - (version &0x0F ), (version &0xF0 ) >>4 );Why remove the "version" output?
The version register is actually not an official register and is subject to change in the future.
I'll fix the typos in next version!
Thanks!
Signature · 4 lines
Best regards, Eric http://www.unixphere.com
PATCH v3 2/3 misc: bmp085: add device tree properties
In reply to Eric Andersson--- Documentation/devicetree/bindings/misc/bmp085.txt | 20 +++++++++++ drivers/misc/bmp085.c | 37 ++++++++++++++++++++- 2 files changed, 56 insertions(+), 1 deletions(-) create mode 100644 Documentation/devicetree/bindings/misc/bmp085.txt
Documentation/devicetree/bindings/misc/bmp085.txt new file +20 -0
@@ -0,0 +1,20 @@ +BMP085/BMP18x digital pressure sensors + +Required properties: +- compatible: bosch-sensortec,bmp085 + +Optional properties: +- chip-id: configurable chip id for non-default chip revisions +- temp-measurement-period: temperature measurement period (milliseconds) +- default-oversampling: default oversampling value to be used at startup, + value range is 0-3 with rising sensitivity. + +Example: + +pressure@77 { + compatible = "bosch-sensortec,bmp085"; + reg = <0x77>; + chip-id = <10>; + temp-measurement-period = <10>; + default-oversampling = <2>; +};
drivers/misc/bmp085.c +36 -1
@@ -50,6 +50,7 @@#include <linux/i2c.h> #include <linux/slab.h> #include <linux/delay.h> +#include <linux/of.h> #define BMP085_NAME "bmp085"#define BMP085_I2C_ADDRESS 0x77
@@ -85,6 +86,7 @@ struct bmp085_data {u32 raw_pressure;u32 temp_measurement_period;unsigned long last_temp_measurement; +u8 chip_id;s32 b6;/* calculated temperature correction coefficient */ };
@@ -385,6 +387,27 @@ static int bmp085_detect(struct i2c_client *client, struct i2c_board_info *info)return 0 ; } +static void __init bmp085_get_of_properties (struct i2c_client *client, +struct bmp085_data *data) +{ +#ifdef CONFIG_OF +struct device_node *np = client->dev.of_node; +u32 prop; + +if (!np) +return ; + +if (!of_property_read_u32 (np,"chip-id" , &prop)) + data->chip_id = prop &0xff ; + +if (!of_property_read_u32 (np,"temp-measurement-period" , &prop)) + data->temp_measurement_period = (prop/100 )*HZ ; + +if (!of_property_read_u32 (np,"default-oversampling" , &prop)) + data->oversampling_setting = prop &0xff ; +#endif +} +static int bmp085_init_client (struct i2c_client *client) {struct bmp085_data *data =i2c_get_clientdata (client);
@@ -393,10 +416,15 @@ static int bmp085_init_client(struct i2c_client *client)if (status <0 )return status; +/* default settings */ data->client = client; + data->chip_id =BMP085_CHIP_ID ; data->last_temp_measurement =0 ; data->temp_measurement_period =1 *HZ ; data->oversampling_setting =3 ; + +bmp085_get_of_properties (client, data); +mutex_init (&data->lock);return 0 ;
@@ -446,6 +474,12 @@ static int __devexit bmp085_remove(struct i2c_client *client)return 0 ; } +static const struct of_device_id bmp085_of_match[] = { + { .compatible ="bosch-sensortec,bmp085" , }, + { }, +}; +MODULE_DEVICE_TABLE (of, bmp085_of_match); +static const struct i2c_device_id bmp085_id[] = { {BMP085_NAME ,0 }, { }
@@ -455,7 +489,8 @@ MODULE_DEVICE_TABLE(i2c, bmp085_id);static struct i2c_driver bmp085_driver = { .driver = { .owner =THIS_MODULE , - .name =BMP085_NAME + .name =BMP085_NAME , + .of_match_table = bmp085_of_match }, .id_table = bmp085_id, .probe = bmp085_probe,
Signature · 1 line
1.7.3.4
PATCH v3 3/3 misc: add support for bmp18x chips to the bmp085 driver
In reply to Eric AnderssonThe bmp18x chip family comes in an I2C respectively SPI variant. Hence, the bmp085 driver was split to support both buses.
--- drivers/misc/Kconfig | 26 ++++++- drivers/misc/Makefile | 2 + drivers/misc/bmp085-i2c.c | 87 ++++++++++++++++++++++++ drivers/misc/bmp085-spi.c | 89 ++++++++++++++++++++++++ drivers/misc/bmp085.c | 163 ++++++++++++++++++-------------------------- drivers/misc/bmp085.h | 33 +++++++++ 6 files changed, 300 insertions(+), 100 deletions(-) create mode 100644 drivers/misc/bmp085-i2c.c create mode 100644 drivers/misc/bmp085-spi.c create mode 100644 drivers/misc/bmp085.h
drivers/misc/Kconfig +22 -4
@@ -452,14 +452,32 @@ config ARM_CHARLCD still useful. config BMP085 - tristate "BMP085 digital pressure sensor" + bool + depends on SYSFS + +config BMP085_I2C + tristate "BMP085 digital pressure sensor on I2C" + select BMP085 + select REGMAP_I2C depends on I2C && SYSFS help - If you say yes here you get support for the Bosch Sensortec - BMP085 digital pressure sensor. + Say Y here if you want to support Bosch Sensortec's digital pressure + sensor hooked to an I2C bus. + + To compile this driver as a module, choose M here: the + module will be called bmp085-i2c. + +config BMP085_SPI + tristate "BMP085 digital pressure sensor on SPI" + select BMP085 + select REGMAP_SPI + depends on SPI_MASTER && SYSFS + help + Say Y here if you want to support Bosch Sensortec's digital pressure + sensor hooked to an SPI bus. To compile this driver as a module, choose M here: the - module will be called bmp085. + module will be called bmp085-spi. config PCH_PHUB tristate "Intel EG20T PCH/LAPIS Semicon IOH(ML7213/ML7223/ML7831) PHUB"
drivers/misc/Makefile +2 -0
@@ -11,6 +11,8 @@ obj-$(CONFIG_ATMEL_PWM) += atmel_pwm.o obj-$(CONFIG_ATMEL_SSC) += atmel-ssc.o obj-$(CONFIG_ATMEL_TCLIB) += atmel_tclib.o obj-$(CONFIG_BMP085) += bmp085.o +obj-$(CONFIG_BMP085_I2C) += bmp085-i2c.o +obj-$(CONFIG_BMP085_SPI) += bmp085-spi.o obj-$(CONFIG_ICS932S401) += ics932s401.o obj-$(CONFIG_LKDTM) += lkdtm.o obj-$(CONFIG_TIFM_CORE) += tifm_core.o
drivers/misc/bmp085-i2c.c new file +87 -0
87 lines not on this page · raw message
drivers/misc/bmp085-spi.c new file +89 -0
89 lines not on this page · raw message
drivers/misc/bmp085.c +67 -96
324 lines not on this page · raw message
drivers/misc/bmp085.h new file +33 -0
@@ -0,0 +1,33 @@ +/* +* Copyright (c) 2012 Bosch Sensortec GmbH +* Copyright (c) 2012 Unixphere AB +* +* This program is free software; you can redistribute it and/or modify +* it under the terms of the GNU General Public License as published by +* the Free Software Foundation; either version 2 of the License, or +* (at your option) any later version. +* +* This program is distributed in the hope that it will be useful, +* but WITHOUT ANY WARRANTY; without even the implied warranty of +* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the +* GNU General Public License for more details. +* +* You should have received a copy of the GNU General Public License +* along with this program; if not, write to the Free Software +* Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA. +*/ + +#ifndef _BMP085_H +#define _BMP085_H + +#include <linux/regmap.h> + +#define BMP085_NAME "bmp085" + +extern struct regmap_config bmp085_regmap_config; + +int bmp085_probe (struct device *dev,struct regmap *regmap); +int bmp085_remove (struct device *dev); +int bmp085_detect (struct device *dev); + +#endif
Signature · 1 line
1.7.3.4
Re: [PATCHv3 3/3] misc: add support for bmp18x chips to the bmp085 driver
drivers/misc/bmp085-i2c.c line 43
Quoted 6 lines · Eric Andersson
drivers/misc/bmp085-i2c.c new file +6
-0+static int __devinit bmp085_i2c_probe (struct i2c_client *client, +const struct i2c_device_id *id) +{ +struct regmap *regmap =regmap_init_i2c (client, &bmp085_regmap_config); + +if (!regmap) {
Should be IS_ERR() - regmap uses PTR_ERR() and for error return values. I'd also consider devm_regmap_init_i2c() (introduced in the merge window) which saves you bothering to free it later on...
drivers/misc/bmp085-i2c.c line 48
Quoted 5 lines
drivers/misc/bmp085-i2c.c new file +5
-0+dev_err (&client->dev,"Failed to init regmap!\n" ); +return -ENOMEM ; + } + +return bmp085_probe (&client->dev, regmap);
...right now it gets leaked so this would also fix an error.
Review
Quoted 2 lines
(quoted diff) +2
-0+static const struct of_device_id bmp085_of_match[] = { + { .compatible = "bosch-sensortec,bmp085", },
Traditionally the stock ticker symbol would be used.
drivers/misc/bmp085.c static s32 bmp085_update_raw_temperature(struct bmp085_data *data) · line 129
Quoted 2 lines
drivers/misc/bmp085.c +2
-0+ status =regmap_bulk_read (data->regmap,BMP085_CONVERSION_REGISTER_MSB , + (u8 *)&tmp,sizeof (tmp));
Should be no need for the cast, the destination array argument is a pointer to void.
Arnd Bergmann
maintainerRe: [PATCHv3 3/3] misc: add support for bmp18x chips to the bmp085 driver
Quoted 4 lines · Mark Brown
Review
Quoted 2 lines
(quoted diff) +2
-0+static const struct of_device_id bmp085_of_match[] = { + { .compatible = "bosch-sensortec,bmp085", },Traditionally the stock ticker symbol would be used.
I though about commenting on that as well, but since Bosch is a foundation and not publically traded, that would be hard to accomplish. Is there an official fallback for companies that don't have a stock ticker symbol?
Arnd
Re: [PATCHv3 3/3] misc: add support for bmp18x chips to the bmp085 driver
Quoted 9 lines · Arnd Bergmann
Quoted 4 lines · Mark Brown
Review
Quoted 2 lines
(quoted diff) +2
-0+static const struct of_device_id bmp085_of_match[] = { + { .compatible = "bosch-sensortec,bmp085", },Traditionally the stock ticker symbol would be used.
I though about commenting on that as well, but since Bosch is a foundation and not publically traded, that would be hard to accomplish. Is there an official fallback for companies that don't have a stock ticker symbol?
Guess we should ask the DT people... I mostly just noticed that the name appeared somewhat verbose - perhaps just plain "bosch" if there's not a better abbrevation?
Re: [PATCHv3 3/3] misc: add support for bmp18x chips to the bmp085 driver
Hi,
Thanks for the review guys!
Quoted 7 lines · Mark Brown
Quoted 5 lines · Arnd Bergmann
Quoted 4 lines · Mark Brown
Review
Quoted 2 lines
(quoted diff) +2
-0+static const struct of_device_id bmp085_of_match[] = { + { .compatible = "bosch-sensortec,bmp085", },Traditionally the stock ticker symbol would be used.
Quoted 7 lines
Quoted 3 lines
I though about commenting on that as well, but since Bosch is a foundation and not publically traded, that would be hard to accomplish. Is there an official fallback for companies that don't have a stock ticker symbol?
Guess we should ask the DT people... I mostly just noticed that the name appeared somewhat verbose - perhaps just plain "bosch" if there's not a better abbrevation?
If there are no further objections let's go with "bosch". I'll prepare a new patch-set ASAP.
Signature · 4 lines
Best regards, Eric http://www.unixphere.com
Re: [PATCHv3 3/3] misc: add support for bmp18x chips to the bmp085 driver
In reply to Mark BrownQuoted 7 lines · Mark Brown
Quoted 5 lines · Arnd Bergmann
Quoted 4 lines · Mark Brown
Review
Quoted 2 lines
(quoted diff) +2
-0+static const struct of_device_id bmp085_of_match[] = { + { .compatible = "bosch-sensortec,bmp085", },Traditionally the stock ticker symbol would be used.
Quoted 7 lines
Quoted 3 lines
I though about commenting on that as well, but since Bosch is a foundation and not publically traded, that would be hard to accomplish. Is there an official fallback for companies that don't have a stock ticker symbol?
Guess we should ask the DT people... I mostly just noticed that the name appeared somewhat verbose - perhaps just plain "bosch" if there's not a better abbrevation?
*MY* official fallback is go with whatever is documented in Documentation/devicetree/bindings/vendor-prefixes.txt. If the needed value isn't there, then add it! :-)
g.
Signature · 2 lines
Grant Likely, B.Sc, P.Eng. Secret Lab Technologies,Ltd.
Quoted 10 lines · Eric Andersson
This is version 3 of the patch-set that adds support for the latest pressure sensors from Bosch Sensortec.
Changes from last version:
- Dropped the platform data in favor of devicetree properties.
- Use regmap as communication layer.
- ChangedKconfiglogic.
- Keep the original bmp085 file name.
- UseEXPORT_SYMBOL_GPL.
Looks all good to me now,