hwmon: (lm73) Fix lower and upper temperature limits
Subsystems (2)
Guenter Roeck
maintainerPATCH 3/3 hwmon: (lm73) Fix lower and upper temperature limits
While the LM73 is only specified for temperatures from -40 to +150 degrees C, its power-up minimum and maximum temperature limits are -256 and +255.75 degrees C. For better consistency and to avoid confusion, clamp limits to the power-up limits and not to -40 / +150 degrees C.
Signed-off-by Guenter Roeck <[email protected]>
--- drivers/hwmon/lm73.c | 7 +++---- 1 file changed, 3 insertions(+), 4 deletions(-)
drivers/hwmon/lm73.c +3 -4
@@ -37,8 +37,8 @@ static const unsigned short normal_i2c[] = { 0x48, 0x49, 0x4a, 0x4c,#define LM73_ID 0x9001/* 0x0190, byte-swapped */ #define DRVNAME "lm73" -#define LM73_TEMP_MIN (-40) -#define LM73_TEMP_MAX 150 +#define LM73_TEMP_MIN (-256000 / 250) +#define LM73_TEMP_MAX (255750 / 250)#define LM73_CTRL_RES_SHIFT 5#define LM73_CTRL_RES_MASK (BIT(5) | BIT(6))
@@ -76,8 +76,7 @@ static ssize_t set_temp(struct device *dev, struct device_attribute *da,return status;/* Write value */ - value = (short )clamp_val (temp /250 ,LM73_TEMP_MIN *4 , -LM73_TEMP_MAX *4 ) <<5 ; + value =clamp_val (temp /250 ,LM73_TEMP_MIN ,LM73_TEMP_MAX ) <<5 ; err =i2c_smbus_write_word_swapped (client, attr->index, value);return (err <0 ) ? err : count; }
Signature · 7 lines
1.7.9.7 _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors