v2 cover Thermal: cpufreq cooling fix

cpufreq cooling uses different frequencies as different cooling states.

But the per_cpu cpufreq_frequency_table may contain duplicate, invalid entries, and it may be in either ascending or descending order. And currently, code for parsing the per_cpu cpufreq_frequency_table is used in several places and inconsistent.

To fix this,
New code is introduce in Patch 1/2, which contains the logic of parsing per_cpu cpufreq_frequency_table, and this piece of code can be used to:
1. get the maximum cooling states
2. translate cpu frequency to cooling state
3. translate cooling state to cpu frequency

Patch 2/2 converts exynos_thermal driver to use the new code introduced in Patch 1/2.

History:
V2: remove cpu cooling table to avoid extra memory allocation.

V1: introduce code to convert per_cpu cpufreq_frequency_table
to clean cpu cooling table (no invalid entry, no duplicate entry, in descending order).

I just run build test here. It would be great that some of you can test it on exynos.
any comments?

thanks,
rui

author reviewer
#1 lore raw

PATCH v2 1/2 Thermal: cpufreq cooling: fix parsing per_cpu cpufreq_frequency_table

cpufreq cooling uses different frequencies as different cooling states.

But the per_cpu cpufreq_frequency_table may contain duplicate, invalid entries, and it may be in either ascending or descending order. And currently, code for parsing the per_cpu cpufreq_frequency_table is used in several places and inconsistent.

Now introduce new code to
1. get the maximum cooling states
2. translate cooling state to cpu frequency
3. translate cpu frequency to cooling state
in one place,
with the correct logic of handling per_cpu cpufreq_frequency_table.

---
 drivers/thermal/cpu_cooling.c |  143 +++++++++++++++++++++++++++--------------
 1 file changed, 93 insertions(+), 50 deletions(-)
drivers/thermal/cpu_cooling.c +93 -50
index 455c77a..0d50496 100644
@@ -115,54 +115,109 @@ static int is_cpufreq_valid(int cpu)
 	return !cpufreq_get_policy(&policy, cpu);
 }
 
-/**
- * get_cpu_frequency - get the absolute value of frequency from level.
- * @cpu: cpu for which frequency is fetched.
- * @level: level of frequency, equals cooling state of cpu cooling device
- *	e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc
- */
-static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
+enum cpufreq_cooling_property {
+	GET_LEVEL,
+	GET_FREQ,
+	GET_MAXL,
+};
+
+/*
+ * this is the common function to
+ * 1. get maximum cpu cooling states
+ * 2. translate frequency to cooling state
+ * 3. translate cooling state to frequency
+ * Note that the code may be not in good shape
+ * but it is written in this way in order to:
+ * a) reduce duplicate code as most of the code can be shared.
+ * b) make sure the logic is consistent when translating between
+ *    cooling states and frequencies.
+*/
+static int get_property(unsigned int cpu, unsigned long input,
+	unsigned int* output, enum cpufreq_cooling_property property)
 {
-	int ret = 0, i = 0;
-	unsigned long level_index;
-	bool descend = false;
+	int i, j;
+	unsigned long max_level = 0, level;
+	unsigned int freq = CPUFREQ_ENTRY_INVALID;
+	int descend = -1;
 	struct cpufreq_frequency_table *table =
 					cpufreq_frequency_get_table(cpu);
+	
+	if (!output)
+		return -EINVAL;
+
 	if (!table)
-		return ret;
+		return -EINVAL;
 
-	while (table[i].frequency != CPUFREQ_TABLE_END) {
+	
+	for (i = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) {
+		/* ignore invalid entries */
 		if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
 			continue;
 
-		/*check if table in ascending or descending order*/
-		if ((table[i + 1].frequency != CPUFREQ_TABLE_END) &&
-			(table[i + 1].frequency < table[i].frequency)
-			&& !descend) {
-			descend = true;
-		}
+		/* ignore duplicate entry */
+		if (freq == table[i].frequency)
+			continue;
+
+		/* get the frequency order */
+		if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
+			descend = !!(freq > table[i].frequency);
 
-		/*return if level matched and table in descending order*/
-		if (descend && i == level)
-			return table[i].frequency;
-		i++;
+		freq = table[i].frequency;
+		max_level++;
+	}
+
+	/* get max level */
+	if (property == GET_MAXL) {
+		*output = (unsigned int)level;
+		return 0;
 	}
-	i--;
 
-	if (level > i || descend)
-		return ret;
-	level_index = i - level;
+	if (property == GET_FREQ)
+		level = descend ? input : (max_level - input -1);
 
-	/*Scan the table in reverse order and match the level*/
-	while (i >= 0) {
+
+	for (i = 0, j = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) {
+		/* ignore invalid entry */
 		if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
 			continue;
-		/*return if level matched*/
-		if (i == level_index)
-			return table[i].frequency;
-		i--;
+
+		/* ignore duplicate entry */
+		if (freq == table[i].frequency)
+			continue;
+
+		/* now we have a valid frequency entry */
+		freq = table[i].frequency;
+
+		if (property == GET_LEVEL && (unsigned int)input == freq) {
+			/* get level by frequency */
+			*output = descend ? j : (max_level - j - 1);
+			return 0;
+		}
+		if (property == GET_FREQ && level == j) {
+			/* get frequency by level */
+			*output = freq;
+			return 0;
+		}
+		j++;
 	}
-	return ret;
+	return -EINVAL;
+}
+
+/**
+ * get_cpu_frequency - get the absolute value of frequency from level.
+ * @cpu: cpu for which frequency is fetched.
+ * @level: level of frequency, equals cooling state of cpu cooling device
+ *	e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc
+ */
+static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
+{
+	int ret = 0;
+	unsigned int freq;
+
+	ret = get_property(cpu, level, &freq, GET_FREQ);
+	if (ret)
+		return freq;
+	return 0;
 }
 
 /**
@@ -244,29 +299,17 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
 	struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
 	struct cpumask *maskPtr = &cpufreq_device->allowed_cpus;
 	unsigned int cpu;
-	struct cpufreq_frequency_table *table;
 	unsigned long count = 0;
-	int i = 0;
+	int ret;
 
 	cpu = cpumask_any(maskPtr);
-	table = cpufreq_frequency_get_table(cpu);
-	if (!table) {
-		*state = 0;
-		return 0;
-	}
 
-	for (i = 0; (table[i].frequency != CPUFREQ_TABLE_END); i++) {
-		if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
-			continue;
-		count++;
-	}
+	ret = get_property(cpu, 0, (unsigned int *)&count, GET_MAXL);
 
-	if (count > 0) {
-		*state = --count;
-		return 0;
-	}
+	if (count > 0)
+		*state = count;
 
-	return -EINVAL;
+	return ret;
 }
 
 /**
Signature · 1 line
1.7.9.5
author reviewer
#2 lore raw

PATCH v2 2/2 Thermal: exynos: fix cooling state translation

In reply to Zhang Rui
---
 drivers/thermal/cpu_cooling.c    |   13 ++++++++++++-
 drivers/thermal/exynos_thermal.c |   24 ++----------------------
 include/linux/cpu_cooling.h      |    7 +++++++
 include/linux/thermal.h          |    5 ++++-
 4 files changed, 25 insertions(+), 24 deletions(-)
drivers/thermal/cpu_cooling.c +12 -1
index 0d50496..a3e4aeb 100644
@@ -168,7 +168,7 @@ static int get_property(unsigned int cpu, unsigned long input,
 
 	/* get max level */
 	if (property == GET_MAXL) {
-		*output = (unsigned int)level;
+		*output = (unsigned int)max_level;
 		return 0;
 	}
 
@@ -203,6 +203,17 @@ static int get_property(unsigned int cpu, unsigned long input,
 	return -EINVAL;
 }
 
+unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
+{
+	unsigned int val;
+
+	if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
+		return THERMAL_CSTATE_INVALID;
+	return (unsigned long)val;
+}
+
+EXPORT_SYMBOL(cpufreq_cooling_get_level);
+
 /**
  * get_cpu_frequency - get the absolute value of frequency from level.
  * @cpu: cpu for which frequency is fetched.
drivers/thermal/exynos_thermal.c +2 -22
index cd71e24..509c950 100644
@@ -239,26 +239,6 @@ static int exynos_get_crit_temp(struct thermal_zone_device *thermal,
 	return ret;
 }
 
-static int exynos_get_frequency_level(unsigned int cpu, unsigned int freq)
-{
-	int i = 0, ret = -EINVAL;
-	struct cpufreq_frequency_table *table = NULL;
-#ifdef CONFIG_CPU_FREQ
-	table = cpufreq_frequency_get_table(cpu);
-#endif
-	if (!table)
-		return ret;
-
-	while (table[i].frequency != CPUFREQ_TABLE_END) {
-		if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
-			continue;
-		if (table[i].frequency == freq)
-			return i;
-		i++;
-	}
-	return ret;
-}
-
 /* Bind callback functions for thermal zone */
 static int exynos_bind(struct thermal_zone_device *thermal,
 			struct thermal_cooling_device *cdev)
@@ -285,8 +265,8 @@ static int exynos_bind(struct thermal_zone_device *thermal,
 	/* Bind the thermal zone to the cpufreq cooling device */
 	for (i = 0; i < tab_size; i++) {
 		clip_data = (struct freq_clip_table *)&(tab_ptr[i]);
-		level = exynos_get_frequency_level(0, clip_data->freq_clip_max);
-		if (level < 0)
+		level = cpufreq_cooling_get_level(0, clip_data->freq_clip_max);
+		if (level == THERMAL_CSTATE_INVALID)
 			return 0;
 		switch (GET_ZONE(i)) {
 		case MONITOR_ZONE:
include/linux/cpu_cooling.h +7 -0
index 40b4ef5..bc479b1 100644
@@ -42,6 +42,8 @@ struct thermal_cooling_device *cpufreq_cooling_register(
  * @cdev: thermal cooling device pointer.
  */
 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
+
+unsigned long cpufreq_cooling_get_level(unsigned int, unsigned int);
 #else /* !CONFIG_CPU_THERMAL */
 static inline struct thermal_cooling_device *cpufreq_cooling_register(
 	const struct cpumask *clip_cpus)
@@ -53,6 +55,11 @@ static inline void cpufreq_cooling_unregister(
 {
 	return;
 }
+static inline unsigned long cpufreq_cooling_get_level(unsigned int,
+						 unsigned int)
+{
+	return THERMAL_CSTATE_INVALID;
+}
 #endif	/* CONFIG_CPU_THERMAL */
 
 #endif /* __CPU_COOLING_H__ */
include/linux/thermal.h +4 -1
index f0bd7f9..5a3b428 100644
@@ -33,8 +33,11 @@
 #define THERMAL_MAX_TRIPS	12
 #define THERMAL_NAME_LENGTH	20
 
+/* invalid cooling state */
+#define THERMAL_CSTATE_INVALID -1UL
+
 /* No upper/lower limit requirement */
-#define THERMAL_NO_LIMIT	-1UL
+#define THERMAL_NO_LIMIT	THERMAL_CSTATE_INVALID
 
 /* Unit conversion macros */
 #define KELVIN_TO_CELSIUS(t)	(long)(((long)t-2732 >= 0) ?	\
Signature · 1 line
1.7.9.5