arm64: dts: rockchip: rk3588: add msi-parent for pcie3x4_ep

PATCH Applied Niklas Cassel 2 participants 4 messages Nov 20, 2024 – Jan 3, 2025

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 arm64: dts: rockchip: rk3588: add msi-parent for pcie3x4_ep

Add msi-parent for the pcie3x4_ep PCI endpoint node.

The pcie3x4_ep node should use the same msi-parent as the pcie3x4 node (which represents the PCIe controller running in Root Complex mode).

The GIC ITS can be used to trigger an IRQ on the endpoint when any of the endpoint's PCI BARs are written to by the host[1].

[1] https://lore.kernel.org/linux-pci/[email protected]/

---
Hello Heiko, this patch depends on:
https://lore.kernel.org/linux-rockchip/[email protected]/

 arch/arm64/boot/dts/rockchip/rk3588-extra.dtsi | 1 +
 1 file changed, 1 insertion(+)
arch/arm64/boot/dts/rockchip/rk3588-extra.dtsi +1 -0
index 4a950907ea6f..ead151941e84 100644
@@ -213,6 +213,7 @@ pcie3x4_ep: pcie-ep@fe150000 {
 		interrupt-names = "sys", "pmc", "msg", "legacy", "err",
 				  "dma0", "dma1", "dma2", "dma3";
 		max-link-speed = <3>;
+		msi-parent = <&its1 0x0000>;
 		iommus = <&mmu600_pcie 0x0000>;
 		num-lanes = <4>;
 		phys = <&pcie30phy>;
Signature · 1 line
2.47.0
maintainer Applied
#1 lore raw
Quoted 9 lines · Niklas Cassel

Add msi-parent for the pcie3x4_ep PCI endpoint node.

The pcie3x4_ep node should use the same msi-parent as the pcie3x4 node (which represents the PCIe controller running in Root Complex mode).

The GIC ITS can be used to trigger an IRQ on the endpoint when any of the endpoint's PCI BARs are written to by the host[1].

[...]

Applied, thanks!

[1/1] arm64: dts: rockchip: rk3588: add msi-parent for pcie3x4_ep

      commit: b6f09f497b07008aa65c31341138cecafa78222c

Best regards,

Signature · 1 line
Heiko Stuebner <[email protected]>
#2 lore raw
Quoted 10 lines · Heiko Stuebner
Quoted 8 lines · Niklas Cassel

Add msi-parent for the pcie3x4_ep PCI endpoint node.

The pcie3x4_ep node should use the same msi-parent as the pcie3x4 node (which represents the PCIe controller running in Root Complex mode).

The GIC ITS can be used to trigger an IRQ on the endpoint when any of the endpoint's PCI BARs are written to by the host[1].

Quoted 7 lines
Quoted 1 line

[...]

Applied, thanks!

[1/1] arm64: dts: rockchip: rk3588: add msi-parent for pcie3x4_ep

      commit: b6f09f497b07008aa65c31341138cecafa78222c

Hello Heiko,

When I sent this patch, I had tested it against Frank's v8 series which adds support for a PCIe endpoint triggering an interrupt (using GIC ITS) when the host side writes to the PCI BAR that the endpoint has configured as doorbell:
https://lore.kernel.org/linux-pci/[email protected]/

However, it seems that in v10 of his series, he has changed it so that the PCIe endpoint node now requires 'msi-map' instead of 'msi-parent' (just like how it is done in the PCIe root complex node):

See:
https://lore.kernel.org/linux-pci/[email protected]/

"""
Changes in v10:

[...]

- Use "msi-map" in pci ep controler node, instead of of msi-parent. first argument is

	(func_no << 8 | vfunc_no)

"""

I didn't realize that DT property required for this feature could change so drastically, since DT is supposed to describe hardware, and msi-parent made perfect sense, since this property is usually the one used for devices connected to a bus.
(msi-map is usually only used on the host bus adapter / root complex.)

Knowing what I now know, I should have waited until this feature had landed before submitting this patch. I apologize for this.

Could you please drop this patch from your v6.14-armsoc/dts64 branch?

Or should I send a revert?

Once Frank's series has landed, I can resubmit a patch that adds whichever DT property he finally ends up using.

Kind regards,
Niklas

maintainer
#3 lore raw

Hey Niklas,

Am Freitag, 20. Dezember 2024, 09:03:36 CET schrieb Niklas Cassel:

Quoted 13 lines · Heiko Stuebner
Quoted 12 lines · Niklas Cassel
Quoted 9 lines

Add msi-parent for the pcie3x4_ep PCI endpoint node.

The pcie3x4_ep node should use the same msi-parent as the pcie3x4 node (which represents the PCIe controller running in Root Complex mode).

The GIC ITS can be used to trigger an IRQ on the endpoint when any of the endpoint's PCI BARs are written to by the host[1].

[...]

Quoted 7 lines
Quoted 5 lines

Applied, thanks!

[1/1] arm64: dts: rockchip: rk3588: add msi-parent for pcie3x4_ep

      commit: b6f09f497b07008aa65c31341138cecafa78222c

Could you please drop this patch from your v6.14-armsoc/dts64 branch?

happy new year :-) .

I've now dropped the patch from my queue

Heiko