nds32: ag101/ag102: Inconsistent timer3 counter unit?
Hi Macpaul,
For the case CONFIG_FTTMR010_EXT_CLK is not defined:
In reset_timer_masked():
lastdec = readl(&tmr->timer3_counter) / (CONFIG_SYS_CLK_FREQ / 2);
In get_timer_masked():
ulong now = readl(&tmr->timer3_counter) / (CONFIG_SYS_CLK_FREQ / 2 / 1024);
The code looks strange.
(Why one needs to be divided by 1024 and the other one does not?) I'm not sure which one is correct.
Regards,
Axel
Hi Axel,
2013/7/3 Axel Lin <[email protected]>:
Quoted 14 lines
Hi Macpaul,
For the case
CONFIG_FTTMR010_EXT_CLKis not defined:In
reset_timer_masked():
lastdec =readl(&tmr->timer3_counter)/ (CONFIG_SYS_CLK_FREQ/ 2);In
get_timer_masked():
ulong now =readl(&tmr->timer3_counter)/ (CONFIG_SYS_CLK_FREQ/ 2 / 1024);The code looks strange.
(Why one needs to be divided by 1024 and the other one does not?) I'm not sure which one is correct.
Quoted 7 lines
Regards,
Axel_______________________________________________
U-Boot mailing list
U-Boot at lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot
The unit of "readl(&tmr->timer3_counter) / (CONFIG_SYS_CLK_FREQ / 2)" is second. However, there is a definition CONFIG_SYS_HZ = 1000 in include/configs/adp-ag101p.h ,
this means the accuracy of "lastdec" and "now" should be in millisecond, I think divided by 1024 is just for this purpose, but use CONFIG_SYS_HZ to replace 1024 would be better.
so the correct should be:
lastdec = readl(&tmr->timer3_counter) / (CONFIG_SYS_CLK_FREQ / 2 / CONFIG_SYS_HZ);
ulong now = readl(&tmr->timer3_counter) / (CONFIG_SYS_CLK_FREQ / 2 / CONFIG_SYS_HZ);
Best Regards,