regulator: da903x: Convert da9034 ldo12 to use linear ranges
PATCH 1/1 regulator: da903x: Convert da9034 ldo12 to use linear ranges
The voltage table of da9034 LDO12 is:
1700000, 1750000, 1800000, 1850000, 1900000, 1950000, 2000000, 2050000 2700000, 2750000, 2800000, 2850000, 2900000, 2950000, 3000000, 3050000
The voltage table is composed of two linear ranges:
for selector 0 ... 7:
volt = 1700000 + 50000 * selector
for selector 8 ... 15:
volt = 2700000 + 50000 * (selector - 8)This patch converts da9034 LDO12 to use newly introduced helpers for multiple linear ranges.
Signed-off-by Axel Lin <[email protected]>
--- drivers/regulator/da903x.c | 45 ++++++++++----------------------------------- 1 file changed, 10 insertions(+), 35 deletions(-)
drivers/regulator/da903x.c +10 -35
@@ -252,39 +252,12 @@ static int da9034_set_dvc_voltage_sel(struct regulator_dev *rdev,return ret; } -static int da9034_map_ldo12_voltage (struct regulator_dev *rdev, -int min_uV,int max_uV) -{ -struct da903x_regulator_info *info =rdev_get_drvdata (rdev); -int sel; - -if (check_range (info, min_uV, max_uV)) { -pr_err ("invalid voltage range (%d, %d) uV\n" , min_uV, max_uV); -return -EINVAL ; - } - - sel =DIV_ROUND_UP (min_uV - info->desc.min_uV, info->desc.uV_step); - sel = (sel >=20 ) ? sel -12 : ((sel >7 ) ?8 : sel); - -return sel; -} - -static int da9034_list_ldo12_voltage (struct regulator_dev *rdev, -unsigned selector) -{ -struct da903x_regulator_info *info =rdev_get_drvdata (rdev); -int volt; - -if (selector >=8 ) - volt =2700000 + rdev->desc->uV_step * (selector -8 ); -else - volt = rdev->desc->min_uV + rdev->desc->uV_step * selector; - -if (volt > info->max_uV) -return -EINVAL ; - -return volt; -} +static const struct regulator_linear_range da9034_ldo12_ranges[] = { + { .min_uV =1700000 , .max_uV =2050000 , .min_sel =0 , .max_sel =7 , + .uV_step =50000 }, + { .min_uV =2700000 , .max_uV =3050000 , .min_sel =8 , .max_sel =15 , + .uV_step =50000 }, +};static struct regulator_ops da903x_regulator_ldo_ops = { .set_voltage_sel = da903x_set_voltage_sel,
@@ -332,8 +305,8 @@ static struct regulator_ops da9034_regulator_dvc_ops = {static struct regulator_ops da9034_regulator_ldo12_ops = { .set_voltage_sel = da903x_set_voltage_sel, .get_voltage_sel = da903x_get_voltage_sel, - .list_voltage = da9034_list_ldo12_voltage, - .map_voltage = da9034_map_ldo12_voltage, + .list_voltage = regulator_list_voltage_linear_range, + .map_voltage = regulator_map_voltage_linear_range, .enable = da903x_enable, .disable = da903x_disable, .is_enabled = da903x_is_enabled,
@@ -476,6 +449,8 @@ static int da903x_regulator_probe(struct platform_device *pdev)if (ri->desc.id ==DA9034_ID_LDO12 ) { ri->desc.ops = &da9034_regulator_ldo12_ops; ri->desc.n_voltages =16 ; + ri->desc.linear_ranges = da9034_ldo12_ranges; + ri->desc.n_linear_ranges =ARRAY_SIZE (da9034_ldo12_ranges); }if (ri->desc.id ==DA9030_ID_LDO14 )
Signature · 1 line
1.8.1.2
Quoted 3 lines · Axel Lin
The voltage table of da9034 LDO12 is:
1700000, 1750000, 1800000, 1850000, 1900000, 1950000, 2000000, 2050000 2700000, 2750000, 2800000, 2850000, 2900000, 2950000, 3000000, 3050000
Applied, thanks.