megaraid_sas: Disable controller reset for ppc
Subsystems (2)
PATCH 1/1 megaraid_sas: Disable controller reset for ppc
PPC (PCI ID 0x1000:0x0060) based HBAs will crash the firmware when an OCR is attempted. So disable it for these controllers.
Cc Sumit Saxena <[email protected]>
Cc Adam Radford <[email protected]>
Signed-off-by Hannes Reinecke <[email protected]>
--- drivers/scsi/megaraid/megaraid_sas_base.c | 13 ++++++++++++- 1 file changed, 12 insertions(+), 1 deletion(-)
drivers/scsi/megaraid/megaraid_sas_base.c +12 -1
@@ -516,6 +516,17 @@ megasas_check_reset_ppc(struct megasas_instance *instance,return 0 ; } +/** +* megasas_adp_reset_ppc - For controller reset +* @regs: MFI register set +*/ +static int +megasas_adp_reset_ppc (struct megasas_instance *instance, +struct megasas_register_set __iomem *regs) +{ +return 0 ; +} +static struct megasas_instance_template megasas_instance_template_ppc = { .fire_cmd = megasas_fire_cmd_ppc,
@@ -523,7 +534,7 @@ static struct megasas_instance_template megasas_instance_template_ppc = { .disable_intr = megasas_disable_intr_ppc, .clear_intr = megasas_clear_intr_ppc, .read_fw_status_reg = megasas_read_fw_status_reg_ppc, - .adp_reset = megasas_adp_reset_xscale, + .adp_reset = megasas_adp_reset_ppc, .check_reset = megasas_check_reset_ppc, .service_isr = megasas_isr, .tasklet = megasas_complete_cmd_dpc,
Signature · 1 line
1.7.12.4