Skip to contentSkip to conversation

Bluetooth: Read flow control mode on AMP controller init

PATCH In review Marcel Holtmann 1 participant 1 message Oct 7, 2013

Subsystems (2)
lore
Share & tools
lore

Marcel Holtmann

author maintainer
#0 lore raw

PATCH 2/2 Bluetooth: Read flow control mode on AMP controller init

When initializing an AMP controller, read its current flow control mode so that the correct value is used.

The AMP controller defaults to block based flow control and this extra command is just to double check.

---
 net/bluetooth/hci_core.c | 3 +++
 1 file changed, 3 insertions(+)
net/bluetooth/hci_core.c +3 -0
index 967739c..0c636ba 100644
@@ -319,6 +319,9 @@ static void amp_init(struct hci_request *req)
 	/* Read Data Blk size */
 	hci_req_add(req, HCI_OP_READ_DATA_BLOCK_SIZE, 0, NULL);
 
+	/* Read Flow Control Mode */
+	hci_req_add(req, HCI_OP_READ_FLOW_CONTROL_MODE, 0, NULL);
+
 	/* Read Location Data */
 	hci_req_add(req, HCI_OP_READ_LOCATION_DATA, 0, NULL);
 }
Signature · 1 line
1.8.3.1