hwmon: lm73: reset device during lm73_probe()

PATCH In review Chris Verges 2 participants 7 messages Oct 28, 2013

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 hwmon: lm73: reset device during lm73_probe()

The LM73 datasheet recommends resetting the sensor at power-up to avoid certain VDD ramp-up problems. The full sequence and rationale is described in the LM73 datasheet, May 2009 revision, page 19, section "Power Supply Ramp-Up Considerations."

This patch augments the lm73_probe() behavior to perform the described reset sequence at device initialization time. The sequence performed is:

1. Power down the LM73 using the "PD" bit in the CONF register.
2. Wait at least 115 msec for the LM73 to process the request.
3. Power up the LM73 using the reverse process.

The datasheet recommends running the reset sequence only after VDD has been cut/restored to a LM73. This patch assumes that VDD is provided to the sensor at system boot and is not cut/restored during the runtime of the system. For embedded systems that may provide such control, additional patching of the driver or module unloading/loading would be required.

---
 Documentation/hwmon/lm73 |    9 ++++++++
 drivers/hwmon/lm73.c     |   52 +++++++++++++++++++++++++++++++++++++++++++++-
 2 files changed, 60 insertions(+), 1 deletion(-)
Documentation/hwmon/lm73 +9 -0
index 8af059d..a116fc8 100644
@@ -18,6 +18,15 @@ Description
 The LM73 is a digital temperature sensor.  All temperature values are
 given in degrees Celsius.
 
+Initialization
+--------------
+
+At initialization, the LM73 driver attempts to detect the device by
+reading the control, configuration, and id registers.  The device is
+next probed, at which time a "soft reset" is performed, as recommended
+by TI in the "Power Supply Ramp-Up Considerations" section of the LM73
+datasheet (May 2009 revision, Page 19).
+
 Measurement Resolution Support
 ------------------------------
 
drivers/hwmon/lm73.c +51 -1

76 lines not on this page · raw message

Signature · 7 lines
1.7.9.5


_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
maintainer
#1 lore raw
Quoted 13 lines · Chris Verges

The LM73 datasheet recommends resetting the sensor at power-up to avoid certain VDD ramp-up problems. The full sequence and rationale is described in the LM73 datasheet, May 2009 revision, page 19, section "Power Supply Ramp-Up Considerations."

This patch augments the lm73_probe() behavior to perform the described reset sequence at device initialization time. The sequence performed is:

1. Power down the LM73 using the "PD" bit in the CONF register.
2. Wait at least 115 msec for the LM73 to process the request.
3. Power up the LM73 using the reverse process.

Quoted 7 lines

The datasheet recommends running the reset sequence only after VDD has been cut/restored to a LM73. This patch assumes that VDD is provided to the sensor at system boot and is not cut/restored during the runtime of the system. For embedded systems that may provide such control, additional patching of the driver or module unloading/loading would be required.

Hi Chris,

common assumption is that the chip is enabled and pre-configured by the BIOS or ROMMON. If so, this code is unnecessary and just adds 100+ ms to the system boot time for each LM73 sensor. I don't think that would be a good idea.

The datasheet says "... In systems where there is a large amount of capacitance on the VDD node, the LM73 power supply ramp-up time can become excessively long", which is defined as "A linear power-on-ramp of less than 0.7V/msec and an exponential ramp with an RC time constant of more than 1.25 msec is categorized as a slow power-supply ramp". The soft-reset is only required if this is the case.

Are there indications that this condition is actually seen on real hardware, and not taken care of by the BIOS/ROMMON ? If so, a module parameter, platform data, and/or devicetree property to indicate the condition might be acceptable, but not a one-for-all mandatory chip reset and associated delay.

More comments below.

Thanks,
Guenter

Quoted 63 lines
---
 Documentation/hwmon/lm73 |    9 ++++++++
 drivers/hwmon/lm73.c     |   52 +++++++++++++++++++++++++++++++++++++++++++++-
 2 files changed, 60 insertions(+), 1 deletion(-)
Documentation/hwmon/lm73 +9 -0
index 8af059d..a116fc8 100644
@@ -18,6 +18,15 @@ Description
 The LM73 is a digital temperature sensor.  All temperature values are
 given in degrees Celsius.
 
+Initialization
+--------------
+
+At initialization, the LM73 driver attempts to detect the device by
+reading the control, configuration, and id registers.  The device is
+next probed, at which time a "soft reset" is performed, as recommended
+by TI in the "Power Supply Ramp-Up Considerations" section of the LM73
+datasheet (May 2009 revision, Page 19).
+
 Measurement Resolution Support
 ------------------------------
 
drivers/hwmon/lm73.c +14 -1
index 9bde964..0f6ce2a 100644
@@ -21,7 +21,7 @@
 #include <linux/hwmon.h>
 #include <linux/hwmon-sysfs.h>
 #include <linux/err.h>
-
+#include <linux/delay.h>
 
 /* Addresses scanned */
 static const unsigned short normal_i2c[] = { 0x48, 0x49, 0x4a, 0x4c,
@@ -47,6 +47,15 @@ static const unsigned short normal_i2c[] = { 0x48, 0x49, 0x4a, 0x4c,
 #define LM73_CTRL_HI_SHIFT	2
 #define LM73_CTRL_LO_SHIFT	1
 
+#define LM73_CONF_PD_MASK	BIT(7)
+
+/*
+ * When resetting the LM73, we must wait longer than the maximum
+ * conversion time specified in "Temperature-to-Digital Converter
+ * Characteristics" (LM73 datasheet, May 2009 rev, page 5)
+ */
+#define LM73_MIN_RESET_TIME_MS	115
+
 static const unsigned short lm73_convrates[] = {
 	14,	/* 11-bits (0.25000 C/LSB): RES1 Bit = 0, RES0 Bit = 0 */
 	28,	/* 12-bits (0.12500 C/LSB): RES1 Bit = 0, RES0 Bit = 1 */
@@ -201,6 +210,44 @@ static const struct attribute_group lm73_group = {
 
 /* device probe and removal */
 
+static int lm73_soft_reset(struct i2c_client *client)
+{
+	struct device *hwmon_dev = i2c_get_clientdata(client);
+	s32 err;

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 226

Quoted 10 lines
drivers/hwmon/lm73.c +10 -0
+	u8 value;
+
+	err = i2c_smbus_read_byte_data(client, LM73_REG_CONF);
+	if (err < 0)
+		goto reset_error;
+
+	value = err;
+	value &= ~(3 << 0); /* always clear bits 1:0 */
+	value |= (1 << 6);  /* always set bit 6 */
+

You are using BIT() above, making this inconsistent.

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 228

Quoted 2 lines
drivers/hwmon/lm73.c +2 -0
+	dev_dbg(&client->dev, "%s: powering down the sensor\n",
+		dev_name(hwmon_dev));

Kind of redundant to use dev_err and then display the device name again. Same below. Besides, I don't think the debug messages provide real value.

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 235

Quoted 7 lines
drivers/hwmon/lm73.c +7 -0
+	value |= LM73_CONF_PD_MASK;
+	err = i2c_smbus_write_byte_data(client, LM73_REG_CONF, value);
+	if (err < 0)
+		goto reset_error;
+
+	mdelay(LM73_MIN_RESET_TIME_MS);
+

Datasheet says one has to wait for the conversion time, which depends on the configured resolution. This means that, most of the time, you are waiting way too long here - especially in the presumed context that the chip has not been initialized by the ROMMON/BIOS.

Quoted 19 lines
drivers/hwmon/lm73.c +15 -0
+	dev_dbg(&client->dev, "%s: powering up the sensor\n",
+		dev_name(hwmon_dev));
+	value &= ~LM73_CONF_PD_MASK;
+	err = i2c_smbus_write_byte_data(client, LM73_REG_CONF, value);
+	if (err < 0)
+		goto reset_error;
+
+	return 0;
+
+reset_error:
+	dev_err(&client->dev, "%s: unable to reset device\n",
+		dev_name(hwmon_dev));
+	return err;
+}
+
 static int
 lm73_probe(struct i2c_client *client, const struct i2c_device_id *id)
 {

drivers/hwmon/lm73.c lm73_probe(struct i2c_client *client, const struct i2c_device_id *id) · line 287

Quoted 6 lines
drivers/hwmon/lm73.c +3 -0
@@ -235,6 +282,9 @@ lm73_probe(struct i2c_client *client, const struct i2c_device_id *id)
 	dev_info(&client->dev, "%s: sensor '%s'\n",
 		 dev_name(data->hwmon_dev), client->name);
 
+	/* Reset the device */
+	status = lm73_soft_reset(client);
+

What exactly is the point of returning status ...

drivers/hwmon/lm73.c lm73_probe(struct i2c_client *client, const struct i2c_device_id *id) · line 288

Quoted 1 line
drivers/hwmon/lm73.c +0 -0
 	return 0;

just to ignore it ?

Quoted 11 lines
drivers/hwmon/lm73.c +0 -0
 exit_remove:
Signature · 7 lines
1.7.9.5


_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#2 lore raw
In reply to Chris Verges
Quoted 18 lines · Guenter Roeck
Quoted 4 lines · Chris Verges

The LM73 datasheet recommends resetting the sensor at power-up to avoid certain VDD ramp-up problems. The full sequence and rationale is described in the LM73 datasheet, May 2009 revision, page 19, section "Power Supply Ramp-Up Considerations."

common assumption is that the chip is enabled and pre-configured by the BIOS or ROMMON. If so, this code is unnecessary and just adds 100+ ms to the system boot time for each LM73 sensor. I don't think that would be a good idea.

The datasheet says "... In systems where there is a large amount of capacitance on the VDD node, the LM73 power supply ramp-up time can become excessively long", which is defined as "A linear power-on-ramp of less than 0.7V/msec and an exponential ramp with an RC time constant of more than 1.25 msec is categorized as a slow power-supply ramp". The soft-reset is only required if this is the case.

Quoted 2 lines

Are there indications that this condition is actually seen on real hardware, and not taken care of by the BIOS/ROMMON?

Yes, I encountered this problem on an embedded system and discovered the note in the datasheet as part of the debugging of that problem. The LM73 started returning random, sporadic temperature readings as a result of VDD being ramped too slowly. The app note's tone makes the recommendation sound like the TI-preferred methodology of device initialization for guaranteed behavior, and so modifying the probe() directly seemed like a better choice than relying on the user to know to enable this functionality via module params, platform data, or devicetree properties.

Quoted 4 lines

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 226

Quoted 3 lines
drivers/hwmon/lm73.c +3 -0
+	value &= ~(3 << 0); /* always clear bits 1:0 */
+	value |= (1 << 6);  /* always set bit 6 */
+

You are using BIT() above, making this inconsistent.

Outstanding, I'll update to use BIT().

Quoted 6 lines

Review

Quoted 2 lines
(quoted diff) +2 -0
+	dev_dbg(&client->dev, "%s: powering down the sensor\n",
+		dev_name(hwmon_dev));

Kind of redundant to use dev_err and then display the device name again. Same below. Besides, I don't think the debug messages provide real value.

This was for me to do some debugging. I'll remove it.

Quoted 11 lines

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 235

Quoted 7 lines
drivers/hwmon/lm73.c +7 -0
+	value |= LM73_CONF_PD_MASK;
+	err = i2c_smbus_write_byte_data(client, LM73_REG_CONF, value);
+	if (err < 0)
+		goto reset_error;
+
+	mdelay(LM73_MIN_RESET_TIME_MS);
+

Datasheet says one has to wait for the conversion time, which depends on the configured resolution. This means that, most of the time, you are waiting way too long here - especially in the presumed context that the chip has not been initialized by the ROMMON/BIOS.

Agreed, this could be an optimization made later if someone wanted to implement a look-up table. The theoretical delta would be 15 msec in 11-bit mode versus 115 msec in 14-bit mode. I'd prefer to not rely on the device being in 11-bit mode for an initial release of the changeset, however, as the module loading/unloading methodology could also be used at runtime to reset a system.

Quoted 4 lines

drivers/hwmon/lm73.c lm73_probe(struct i2c_client *client, const struct i2c_device_id *id) · line 287

Quoted 3 lines
drivers/hwmon/lm73.c +3 -0
+	/* Reset the device */
+	status = lm73_soft_reset(client);
+

What exactly is the point of returning status ...

For me to print an error message that wasn't implemented. Good catch. I'll update as part of the revised patch.

Many thanks!
Chris

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

#3 lore raw

PATCH 1/1 hwmon: lm73: reset device during lm73_probe()

In reply to Chris Verges

The LM73 datasheet recommends resetting the sensor at power-up to avoid certain VDD ramp-up problems. The full sequence and rationale is described in the LM73 datasheet, May 2009 revision, page 19, section "Power Supply Ramp-Up Considerations."

This patch augments the lm73_probe() behavior to perform the described reset sequence at device initialization time. The sequence performed is:

1. Power down the LM73 using the "PD" bit in the CONF register.
2. Wait at least 14 to 112 msec for the LM73 to process the request (depending on conversion resolution configured)
3. Power up the LM73 using the reverse process.

The datasheet recommends running the reset sequence only after VDD has been cut/restored to a LM73. This patch assumes that VDD is provided to the sensor at system boot and is not cut/restored during the runtime of the system. For embedded systems that may provide such control, additional patching of the driver or module unloading/loading would be required.

---
 Documentation/hwmon/lm73 |    9 +++++++++
 drivers/hwmon/lm73.c     |   48 +++++++++++++++++++++++++++++++++++++++++++++-
 2 files changed, 56 insertions(+), 1 deletion(-)
Documentation/hwmon/lm73 +9 -0
index 8af059d..a116fc8 100644
@@ -18,6 +18,15 @@ Description
 The LM73 is a digital temperature sensor.  All temperature values are
 given in degrees Celsius.
 
+Initialization
+--------------
+
+At initialization, the LM73 driver attempts to detect the device by
+reading the control, configuration, and id registers.  The device is
+next probed, at which time a "soft reset" is performed, as recommended
+by TI in the "Power Supply Ramp-Up Considerations" section of the LM73
+datasheet (May 2009 revision, Page 19).
+
 Measurement Resolution Support
 ------------------------------
 
drivers/hwmon/lm73.c +47 -1

72 lines not on this page · raw message

Signature · 7 lines
1.7.9.5


_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
#4 lore raw
In reply to Chris Verges
Quoted 7 lines · Guenter Roeck

Review

Quoted 2 lines · Chris Verges
(quoted diff) +2 -0
+	mdelay(LM73_MIN_RESET_TIME_MS);
+

Datasheet says one has to wait for the conversion time, which depends on the configured resolution. This means that, most of the time, you are waiting way too long here - especially in the presumed context that the chip has not been initialized by the ROMMON/BIOS.

In reviewing the driver while making the other changes, I discovered that the look-up table was already implemented for the resolution support. (There goes my memory!) I've hooked it in to the delay mechanism here.

Chris

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

maintainer
#5 lore raw
In reply to Chris Verges
Quoted 22 lines · Chris Verges
Quoted 18 lines · Guenter Roeck
Quoted 4 lines · Chris Verges

The LM73 datasheet recommends resetting the sensor at power-up to avoid certain VDD ramp-up problems. The full sequence and rationale is described in the LM73 datasheet, May 2009 revision, page 19, section "Power Supply Ramp-Up Considerations."

common assumption is that the chip is enabled and pre-configured by the BIOS or ROMMON. If so, this code is unnecessary and just adds 100+ ms to the system boot time for each LM73 sensor. I don't think that would be a good idea.

The datasheet says "... In systems where there is a large amount of capacitance on the VDD node, the LM73 power supply ramp-up time can become excessively long", which is defined as "A linear power-on-ramp of less than 0.7V/msec and an exponential ramp with an RC time constant of more than 1.25 msec is categorized as a slow power-supply ramp". The soft-reset is only required if this is the case.

Quoted 2 lines

Are there indications that this condition is actually seen on real hardware, and not taken care of by the BIOS/ROMMON?

Quoted 10 lines

Yes, I encountered this problem on an embedded system and discovered the note in the datasheet as part of the debugging of that problem. The LM73 started returning random, sporadic temperature readings as a result of VDD being ramped too slowly. The app note's tone makes the recommendation sound like the TI-preferred methodology of device initialization for guaranteed behavior, and so modifying the probe() directly seemed like a better choice than relying on the user to know to enable this functionality via module params, platform data, or devicetree properties.

It is not acceptable to affect everyone because one embedded system vendor violates voltage ramp-up time for this chip.

The embedded system should have its well defined configuration, and support devicetree and/or platform initialization code. So adding it through one or both of those methods should be straightforward. The (end-)user should not have to be involved; the company providing the system should.

Thanks,
Guenter

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

maintainer
#6 lore raw
In reply to Chris Verges
Quoted 74 lines · Chris Verges

The LM73 datasheet recommends resetting the sensor at power-up to avoid certain VDD ramp-up problems. The full sequence and rationale is described in the LM73 datasheet, May 2009 revision, page 19, section "Power Supply Ramp-Up Considerations."

This patch augments the lm73_probe() behavior to perform the described reset sequence at device initialization time. The sequence performed is:

1. Power down the LM73 using the "PD" bit in the CONF register.
2. Wait at least 14 to 112 msec for the LM73 to process the request (depending on conversion resolution configured)
3. Power up the LM73 using the reverse process.

The datasheet recommends running the reset sequence only after VDD has been cut/restored to a LM73. This patch assumes that VDD is provided to the sensor at system boot and is not cut/restored during the runtime of the system. For embedded systems that may provide such control, additional patching of the driver or module unloading/loading would be required.

---
 Documentation/hwmon/lm73 |    9 +++++++++
 drivers/hwmon/lm73.c     |   48 +++++++++++++++++++++++++++++++++++++++++++++-
 2 files changed, 56 insertions(+), 1 deletion(-)
Documentation/hwmon/lm73 +9 -0
index 8af059d..a116fc8 100644
@@ -18,6 +18,15 @@ Description
 The LM73 is a digital temperature sensor.  All temperature values are
 given in degrees Celsius.
 
+Initialization
+--------------
+
+At initialization, the LM73 driver attempts to detect the device by
+reading the control, configuration, and id registers.  The device is
+next probed, at which time a "soft reset" is performed, as recommended
+by TI in the "Power Supply Ramp-Up Considerations" section of the LM73
+datasheet (May 2009 revision, Page 19).
+
 Measurement Resolution Support
 ------------------------------
 
drivers/hwmon/lm73.c +4 -1
index 9bde964..5ee582f 100644
@@ -21,7 +21,7 @@
 #include <linux/hwmon.h>
 #include <linux/hwmon-sysfs.h>
 #include <linux/err.h>
-
+#include <linux/delay.h>
 
 /* Addresses scanned */
 static const unsigned short normal_i2c[] = { 0x48, 0x49, 0x4a, 0x4c,
@@ -47,6 +47,8 @@ static const unsigned short normal_i2c[] = { 0x48, 0x49, 0x4a, 0x4c,
 #define LM73_CTRL_HI_SHIFT	2
 #define LM73_CTRL_LO_SHIFT	1
 
+#define LM73_CONF_PD_MASK	BIT(7)
+
 static const unsigned short lm73_convrates[] = {
 	14,	/* 11-bits (0.25000 C/LSB): RES1 Bit = 0, RES0 Bit = 0 */
 	28,	/* 12-bits (0.12500 C/LSB): RES1 Bit = 0, RES0 Bit = 1 */
@@ -201,6 +203,44 @@ static const struct attribute_group lm73_group = {
 
 /* device probe and removal */
 
+static int lm73_soft_reset(struct i2c_client *client)

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 216

Quoted 10 lines
drivers/hwmon/lm73.c +10 -0
+{
+	struct lm73_data *data = i2c_get_clientdata(client);
+	s32 err;
+	u8 value;
+	unsigned long res;
+
+	err = i2c_smbus_read_byte_data(client, LM73_REG_CONF);
+	if (err < 0)
+		goto reset_error;
+

You can return err here directly; no need to jump to the end of the function if no cleanup is needed.

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 226

Quoted 4 lines
drivers/hwmon/lm73.c +4 -0
+	value = err;
+	value &= ~(BIT(1) | BIT(0)); /* always clear bits 1:0 */
+	value |= (BIT(6));           /* always set bit 6      */
+

Please no unnecessary ( ).

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 235

Quoted 11 lines
drivers/hwmon/lm73.c +11 -0
+	/* power down the sensor */
+	value |= LM73_CONF_PD_MASK;
+	err = i2c_smbus_write_byte_data(client, LM73_REG_CONF, value);
+	if (err < 0)
+		goto reset_error;
+
+	/* let the sensor settle, dependent on the resolution configured */
+	mutex_lock(&data->lock);
+	res = (data->ctrl & LM73_CTRL_RES_MASK) >> LM73_CTRL_RES_SHIFT;
+	mutex_unlock(&data->lock);
+

The lock doesn't provide any value here. If the resolution changes after the lock is released, you are back to the problem that ctrl may change before or while you wait.

drivers/hwmon/lm73.c static const struct attribute_group lm73_group = { · line 242

Quoted 8 lines
drivers/hwmon/lm73.c +8 -0
+	mdelay(lm73_convrates[res]);
+
+	/* power up the sensor */
+	value &= ~LM73_CONF_PD_MASK;
+	err = i2c_smbus_write_byte_data(client, LM73_REG_CONF, value);
+	if (err < 0)
+		goto reset_error;
+

Just returning err does exactly the same with less code.

Quoted 8 lines
drivers/hwmon/lm73.c +4 -0
+reset_error:
+	return err;
+}
+
 static int
 lm73_probe(struct i2c_client *client, const struct i2c_device_id *id)
 {

drivers/hwmon/lm73.c lm73_probe(struct i2c_client *client, const struct i2c_device_id *id) · line 283

Quoted 9 lines
drivers/hwmon/lm73.c +6 -0
@@ -235,6 +275,12 @@ lm73_probe(struct i2c_client *client, const struct i2c_device_id *id)
 	dev_info(&client->dev, "%s: sensor '%s'\n",
 		 dev_name(data->hwmon_dev), client->name);
 
+	/* Reset the device */
+	status = lm73_soft_reset(client);
+	if (status < 0)
+		dev_warn(&client->dev, "%s: unable to reset device\n",
+			 dev_name(data->hwmon_dev));
+

So what is different now ? You still ignore the error. Just bail out if it happens; the chip presumably won't work anyway in that case.

Also, to avoid the race condition above, you should call the reset function before creating the sysfs attributes.

Also, you still call the reset code unconditionally. As I pointed out, this is unaccceptable, as you are affecting users which are not suffering from the problem you are solving.

Thanks,
Guenter