ARM: tegra: init fuse before setting reset handler
Subsystems (3)
PATCH 1/1 ARM: tegra: init fuse before setting reset handler
CPU reset handler was set before fuse is initialized, but tegra_cpu_reset_handler_enable() uses tegra_chip_id, which is set by tegra_init_fuse(). This patch reorders the calls so the CPU reset handler code does not read an uninitialized variable.
Signed-off-by Alexandre Courbot <[email protected]>
--- arch/arm/mach-tegra/tegra.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm/mach-tegra/tegra.c +1 -1
@@ -92,9 +92,9 @@ static void __init tegra_init_cache(void)static void __init tegra_init_early (void ) { -tegra_cpu_reset_handler_init ();tegra_apb_io_init ();tegra_init_fuse (); +tegra_cpu_reset_handler_init ();tegra_init_cache ();tegra_powergate_init ();tegra_hotplug_init ();
Signature · 1 line
1.8.4.2
Quoted 4 lines · Alexandre Courbot
CPU reset handler was set before fuse is initialized, but
tegra_cpu_reset_handler_enable()usestegra_chip_id, which is set bytegra_init_fuse(). This patch reorders the calls so the CPU reset handler code does not read an uninitialized variable.
Thanks. I forwarded this to the arm-soc maintainers as a patch for 3.13.