tg3: Override clock, link aware and link idle mode during NVRAM dump
Subsystems (3)
PATCH 1/1 tg3: Override clock, link aware and link idle mode during NVRAM dump
When cable is not present the clock speed of some of the devices is reduced based upon power saving mode setting in NVRAM. Due to this NVRAM reads take long time to complete as a result CPU soft lockup message is seen. Fix is to override clock, disable link aware and link idle modes before NVRAM reads and restore them back after the reads are complete. During this period also check if the thread needs to be rescheduled and if there are any signals to handle.
Also decrease the NVRAM command execution timeout value to 1ms.
--- drivers/net/ethernet/broadcom/tg3.c | 45 +++++++++++++++++++++++++++++----- 1 files changed, 38 insertions(+), 7 deletions(-)
drivers/net/ethernet/broadcom/tg3.c +38 -7
@@ -3224,7 +3224,7 @@ static int tg3_nvram_read_using_eeprom(struct tg3 *tp,return 0 ; } -#define NVRAM_CMD_TIMEOUT 10000 +#define NVRAM_CMD_TIMEOUT 100static int tg3_nvram_exec_cmd (struct tg3 *tp,u32 nvram_cmd) {
@@ -11893,9 +11893,9 @@ static int tg3_get_eeprom_len(struct net_device *dev)static int tg3_get_eeprom (struct net_device *dev,struct ethtool_eeprom *eeprom,u8 *data) {struct tg3 *tp =netdev_priv (dev); -int ret; +int ret, cpmu_restore =0 ;u8 *pd; -u32 i, offset, len, b_offset, b_count; +u32 i, offset, len, b_offset, b_count, cpmu_val =0 ;__be32 val;if (tg3_flag (tp,NO_NVRAM ))
@@ -11907,6 +11907,19 @@ static int tg3_get_eeprom(struct net_device *dev, struct ethtool_eeprom *eeprom, eeprom->magic =TG3_EEPROM_MAGIC ; +/* Override clock, link aware and link idle modes */ +if (tg3_flag (tp,CPMU_PRESENT )) { + cpmu_val =tr32 (TG3_CPMU_CTRL ); +if (cpmu_val & (CPMU_CTRL_LINK_AWARE_MODE | +CPMU_CTRL_LINK_IDLE_MODE )) { +tw32 (TG3_CPMU_CTRL , cpmu_val & + ~(CPMU_CTRL_LINK_AWARE_MODE | +CPMU_CTRL_LINK_IDLE_MODE )); + cpmu_restore =1 ; + } + } +tg3_override_clk (tp); +if (offset &3 ) {/* adjustments to start on required 4 byte boundary */ b_offset = offset &3 ;
@@ -11917,7 +11930,7 @@ static int tg3_get_eeprom(struct net_device *dev, struct ethtool_eeprom *eeprom, } ret =tg3_nvram_read_be32 (tp, offset-b_offset, &val);if (ret) -return ret; + goto eeprom_done;memcpy (data, ((char *)&val) + b_offset, b_count); len -= b_count; offset += b_count;
@@ -11929,10 +11942,20 @@ static int tg3_get_eeprom(struct net_device *dev, struct ethtool_eeprom *eeprom,for (i =0 ; i < (len - (len &3 )); i +=4 ) { ret =tg3_nvram_read_be32 (tp, offset + i, &val);if (ret) { +if (i) + i -=4 ; eeprom->len += i; -return ret; + goto eeprom_done; }memcpy (pd + i, &val,4 ); +if (need_resched ()) { +if (signal_pending (current)) { + eeprom->len += i; + ret = -EINTR ; + goto eeprom_done; + } +cond_resched (); + } } eeprom->len += i;
@@ -11943,11 +11966,19 @@ static int tg3_get_eeprom(struct net_device *dev, struct ethtool_eeprom *eeprom, b_offset = offset + len - b_count; ret =tg3_nvram_read_be32 (tp, b_offset, &val);if (ret) -return ret; + goto eeprom_done;memcpy (pd, &val, b_count); eeprom->len += b_count; } -return 0 ; + ret =0 ; + +eeprom_done: +/* Restore clock, link aware and link idle modes */ +tg3_restore_clk (tp); +if (cpmu_restore) +tw32 (TG3_CPMU_CTRL , cpmu_val); + +return ret; }static int tg3_set_eeprom (struct net_device *dev,struct ethtool_eeprom *eeprom,u8 *data)
Signature · 1 line
1.7.1
From: Prashant Sreedharan <[email protected]>
Date: Sat, 24 May 2014 01:32:09 -0700
Quoted 8 lines
When cable is not present the clock speed of some of the devices is reduced based upon power saving mode setting in NVRAM. Due to this NVRAM reads take long time to complete as a result CPU soft lockup message is seen. Fix is to override clock, disable link aware and link idle modes before NVRAM reads and restore them back after the reads are complete. During this period also check if the thread needs to be rescheduled and if there are any signals to handle.
Quoted 4 lines
Also decrease the NVRAM command execution timeout value to 1ms.
Signed-off-by Prashant Sreedharan <[email protected]>Signed-off-by Michael Chan <[email protected]>
Applied to net-next, thanks.