Skip to contentSkip to conversation

about using vfio to assign sr-iov vf to vm

questions Zhang Haoyu 2 participants 9 messages Aug 14, 2014 – Aug 18, 2014 KVM

lore
Share & tools
lore
#0 lore raw

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, ..., so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group?
If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Thanks,
Zhang Haoyu

#1 lore raw
Quoted 8 lines · Zhang Haoyu

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, ..., so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group?
If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

Alex

#2 lore raw
In reply to Zhang Haoyu
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, ..., so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group?
If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

# lspci | grep Ether
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
02:00.1 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
08:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
08:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0c:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10)

I want to direct-assign the VFs of intel 82599(02:00.0 or 02:00.1) to VM,

# lspci -t
-[0000:00]-+-00.0
           +-01.0-[01]--
           +-01.1-[02-03]--+-00.0
           |                      \-00.1
           +-02.0
           +-06.0-[04]--
           +-16.0
           +-1a.0
           +-1c.0-[05-0b]----00.0-[06-0b]--+-04.0-[07]--
           |                               +-05.0-[08]--+-00.0
           |                               |                  \-00.1
           |                               +-06.0-[09]--+-00.0
           |                               |                  \-00.1
           |                               +-08.0-[0a]--+-00.0
           |                               |                  \-00.1
           |                               \-09.0-[0b]--+-00.0
           |                                                  \-00.1
           +-1d.0
           +-1e.0-[0c]----00.0
           +-1f.0
           +-1f.2
           \-1f.3

lspci -vvv -s 02.00.0
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
Latency: 0, Cache Line Size: 64 bytes
Interrupt: pin A routed to IRQ 17
Region 0: Memory at f7e20000 (64-bit, non-prefetchable) [size=128K]
Region 2: I/O ports at e020 [size=32]
Region 4: Memory at f7e44000 (64-bit, non-prefetchable) [size=16K]
Capabilities: [40] Power Management version 3
Flags: PMEClk- DSI+ D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold-)
Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=1 PME-
Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+
Address: 0000000000000000 Data: 0000
Masking: 00000000 Pending: 00000000
Capabilities: [70] MSI-X: Enable+ Count=64 Masked-
Vector table: BAR=4 offset=00000000
PBA: BAR=4 offset=00002000
Capabilities: [a0] Express (v2) Endpoint, MSI 00
DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <512ns, L1 <64us
ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset+
DevCtl: Report errors: Correctable+ Non-Fatal+ Fatal+ Unsupported+
RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop+ FLReset-
MaxPayload 128 bytes, MaxReadReq 512 bytes
DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr- TransPend-
LnkCap: Port #1, Speed 5GT/s, Width x8, ASPM L0s, Latency L0 <1us, L1 <8us
ClockPM- Surprise- LLActRep- BwNot-
LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+
ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt-
LnkSta: Speed 5GT/s, Width x8, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt-
DevCap2: Completion Timeout: Range ABCD, TimeoutDis+
DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis-
LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB
Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS- Compliance De-emphasis: -6dB
LnkSta2: Current De-emphasis Level: -3.5dB, EqualizationComplete-, EqualizationPhase1-
EqualizationPhase2-, EqualizationPhase3-, LinkEqualizationRequest-
Capabilities: [e0] Vital Product Data
Unknown small resource type 06, will not decode more.
Capabilities: [100 v1] Advanced Error Reporting
UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol-
UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol-
UESvrt: DLP+ SDES- TLP- FCP+ CmpltTO- CmpltAbrt- UnxCmplt- RxOF+ MalfTLP+ ECRC- UnsupReq- ACSViol-
CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+
CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+
AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn-
Capabilities: [140 v1] Device Serial Number 00-90-0b-ff-ff-29-33-c2
Capabilities: [150 v1] Alternative Routing-ID Interpretation (ARI)
ARICap: MFVC- ACS-, Next Function: 1
ARICtl: MFVC- ACS-, Function Group: 0
Capabilities: [160 v1] Single Root I/O Virtualization (SR-IOV)
IOVCap: Migration-, Interrupt Message Number: 000
IOVCtl: Enable- Migration- Interrupt- MSE- ARIHierarchy-
IOVSta: Migration-
Initial VFs: 64, Total VFs: 64, Number of VFs: 0, Function Dependency Link: 00 VF offset: 384, stride: 2, Device ID: 10ed
Supported Page Size: 00000553, System Page Size: 00000001
Region 0: Memory at 00000000dfb00000 (64-bit, prefetchable)
Region 3: Memory at 00000000dfc00000 (64-bit, prefetchable)
VF Migration: offset: 00000000, BIR: 0
Kernel driver in use: ixgbe

# lspci -vvv -s 00:01.1
00:01.1 PCI bridge: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port (rev 09) (prog-if 00 [Normal decode])
	Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
	Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
	Latency: 0, Cache Line Size: 64 bytes
	Bus: primary=00, secondary=02, subordinate=03, sec-latency=0
	I/O behind bridge: 0000e000-0000efff
	Memory behind bridge: f7e00000-f7efffff
	Prefetchable memory behind bridge: 00000000dfb00000-00000000dfefffff
	Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR-
	BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B-
		PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn-
	Capabilities: [88] Subsystem: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port
	Capabilities: [80] Power Management version 3
		Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+)
		Status: D0 NoSoftRst+ PME-Enable- DSel=0 DScale=0 PME-
	Capabilities: [90] MSI: Enable+ Count=1/1 Maskable- 64bit-
		Address: fee002f8  Data: 0000
	Capabilities: [a0] Express (v2) Root Port (Slot+), MSI 00
		DevCap:	MaxPayload 128 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us
			ExtTag- RBE+ FLReset-
		DevCtl:	Report errors: Correctable- Non-Fatal- Fatal- Unsupported-
			RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop-
			MaxPayload 128 bytes, MaxReadReq 128 bytes
		DevSta:	CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend-
		LnkCap:	Port #3, Speed 8GT/s, Width x8, ASPM L0s L1, Latency L0 <256ns, L1 <8us
			ClockPM- Surprise- LLActRep- BwNot+
		LnkCtl:	ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk+
			ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt-
		LnkSta:	Speed 5GT/s, Width x8, TrErr- Train- SlotClk+ DLActive- BWMgmt+ ABWMgmt+
		SltCap:	AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surprise-
			Slot #2, PowerLimit 75.000W; Interlock- NoCompl+
		SltCtl:	Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg-
			Control: AttnInd Unknown, PwrInd Unknown, Power- Interlock-
		SltSta:	Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock-
			Changed: MRL- PresDet- LinkState-
		RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible-
		RootCap: CRSVisible-
		RootSta: PME ReqID 0000, PMEStatus- PMEPending-
		DevCap2: Completion Timeout: Not Supported, TimeoutDis- ARIFwd-
		DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd-
		LnkCtl2: Target Link Speed: 8GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -3.5dB
			 Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS-
			 Compliance De-emphasis: -6dB
		LnkSta2: Current De-emphasis Level: -3.5dB, EqualizationComplete-, EqualizationPhase1-
			 EqualizationPhase2-, EqualizationPhase3-, LinkEqualizationRequest-
	Capabilities: [100 v1] Virtual Channel
		Caps:	LPEVC=0 RefClk=100ns PATEntryBits=1
		Arb:	Fixed- WRR32- WRR64- WRR128-
		Ctrl:	ArbSelect=Fixed
		Status:	InProgress-
		VC0:	Caps:	PATOffset=00 MaxTimeSlots=1 RejSnoopTrans-
			Arb:	Fixed+ WRR32- WRR64- WRR128- TWRR128- WRR256-
			Ctrl:	Enable+ ID=0 ArbSelect=Fixed TC/VC=ff
			Status:	NegoPending- InProgress-
	Capabilities: [140 v1] Root Complex Link
		Desc:	PortNumber=03 ComponentID=01 EltType=Config
		Link0:	Desc:	TargetPort=00 TargetComponent=01 AssocRCRB- LinkType=MemMapped LinkValid+
			Addr:	00000000fed19000
	Capabilities: [d94 v1] #19
	Kernel driver in use: pcieport

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

Thanks,
Zhang Haoyu

Quoted 1 line

Alex

#3 lore raw
Quoted 96 lines · Zhang Haoyu
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, ..., so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group?
If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

# lspci | grep Ether
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
02:00.1 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
08:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
08:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0c:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10)

I want to direct-assign the VFs of intel 82599(02:00.0 or 02:00.1) to VM,

# lspci -t
-[0000:00]-+-00.0
           +-01.0-[01]--
           +-01.1-[02-03]--+-00.0
           |                      \-00.1
           +-02.0
           +-06.0-[04]--
           +-16.0
           +-1a.0
           +-1c.0-[05-0b]----00.0-[06-0b]--+-04.0-[07]--
           |                               +-05.0-[08]--+-00.0
           |                               |                  \-00.1
           |                               +-06.0-[09]--+-00.0
           |                               |                  \-00.1
           |                               +-08.0-[0a]--+-00.0
           |                               |                  \-00.1
           |                               \-09.0-[0b]--+-00.0
           |                                                  \-00.1
           +-1d.0
           +-1e.0-[0c]----00.0
           +-1f.0
           +-1f.2
           \-1f.3

lspci -vvv -s 02.00.0
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
Latency: 0, Cache Line Size: 64 bytes
Interrupt: pin A routed to IRQ 17
Region 0: Memory at f7e20000 (64-bit, non-prefetchable) [size=128K]
Region 2: I/O ports at e020 [size=32]
Region 4: Memory at f7e44000 (64-bit, non-prefetchable) [size=16K]
Capabilities: [40] Power Management version 3
Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+
Capabilities: [70] MSI-X: Enable+ Count=64 Masked-
Capabilities: [a0] Express (v2) Endpoint, MSI 00
Capabilities: [e0] Vital Product Data
Capabilities: [100 v1] Advanced Error Reporting
Capabilities: [140 v1] Device Serial Number 00-90-0b-ff-ff-29-33-c2
Capabilities: [150 v1] Alternative Routing-ID Interpretation (ARI)
Capabilities: [160 v1] Single Root I/O Virtualization (SR-IOV)
Kernel driver in use: ixgbe

# lspci -vvv -s 00:01.1
00:01.1 PCI bridge: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port (rev 09) (prog-if 00 [Normal decode])
	Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
	Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
	Latency: 0, Cache Line Size: 64 bytes
	Bus: primary=00, secondary=02, subordinate=03, sec-latency=0
	I/O behind bridge: 0000e000-0000efff
	Memory behind bridge: f7e00000-f7efffff
	Prefetchable memory behind bridge: 00000000dfb00000-00000000dfefffff
	Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR-
	BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B-
		PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn-
	Capabilities: [88] Subsystem: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port
	Capabilities: [80] Power Management version 3
	Capabilities: [90] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [a0] Express (v2) Root Port (Slot+), MSI 00
	Capabilities: [100 v1] Virtual Channel
	Capabilities: [140 v1] Root Complex Link
	Capabilities: [d94 v1] #19
	Kernel driver in use: pcieport
Quoted 2 lines

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

It does not and that's exactly the problem. We must assume that the root port can redirect a transaction from a subordinate device back to another subordinate device without IOMMU translation when ACS support is not present. If you had a device plugged in below 00:01.0, we'd also need to assume that non-IOMMU translated peer-to-peer between devices behind either function, 00:01.0 or 00:01.1, is possible.

Intel has indicated that processor root ports for all Xeon class processors should support ACS and have verified isolation for PCH based root ports allowing us to support quirks in place of ACS support. I'm not aware of any efforts at Intel to verify isolation capabilities of root ports on client processors. They are however aware that lack of ACS is a limiting factor for usability of VT-d, and I hope that we'll see future products with ACS support.

Chances are good that the PCH root port at 00:1c.0 is supported by an ACS quirk, but it seems that your system has a PCIe switch below the root port. If the PCIe switch downstream ports support ACS, then you may be able to move the 82599 to the empty slot at bus 07 to separate the VFs into different IOMMU groups. Thanks,

Alex

#4 lore raw
Quoted 114 lines
Quoted 96 lines
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, ..., so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group?
If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

# lspci | grep Ether
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
02:00.1 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
08:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
08:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0c:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10)

I want to direct-assign the VFs of intel 82599(02:00.0 or 02:00.1) to VM,

# lspci -t
-[0000:00]-+-00.0
           +-01.0-[01]--
           +-01.1-[02-03]--+-00.0
           |                      \-00.1
           +-02.0
           +-06.0-[04]--
           +-16.0
           +-1a.0
           +-1c.0-[05-0b]----00.0-[06-0b]--+-04.0-[07]--
           |                               +-05.0-[08]--+-00.0
           |                               |                  \-00.1
           |                               +-06.0-[09]--+-00.0
           |                               |                  \-00.1
           |                               +-08.0-[0a]--+-00.0
           |                               |                  \-00.1
           |                               \-09.0-[0b]--+-00.0
           |                                                  \-00.1
           +-1d.0
           +-1e.0-[0c]----00.0
           +-1f.0
           +-1f.2
           \-1f.3

lspci -vvv -s 02.00.0
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
Latency: 0, Cache Line Size: 64 bytes
Interrupt: pin A routed to IRQ 17
Region 0: Memory at f7e20000 (64-bit, non-prefetchable) [size=128K]
Region 2: I/O ports at e020 [size=32]
Region 4: Memory at f7e44000 (64-bit, non-prefetchable) [size=16K]
Capabilities: [40] Power Management version 3
Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+
Capabilities: [70] MSI-X: Enable+ Count=64 Masked-
Capabilities: [a0] Express (v2) Endpoint, MSI 00
Capabilities: [e0] Vital Product Data
Capabilities: [100 v1] Advanced Error Reporting
Capabilities: [140 v1] Device Serial Number 00-90-0b-ff-ff-29-33-c2
Capabilities: [150 v1] Alternative Routing-ID Interpretation (ARI)
Capabilities: [160 v1] Single Root I/O Virtualization (SR-IOV)
Kernel driver in use: ixgbe

# lspci -vvv -s 00:01.1
00:01.1 PCI bridge: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port (rev 09) (prog-if 00 [Normal decode])
	Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
	Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
	Latency: 0, Cache Line Size: 64 bytes
	Bus: primary=00, secondary=02, subordinate=03, sec-latency=0
	I/O behind bridge: 0000e000-0000efff
	Memory behind bridge: f7e00000-f7efffff
	Prefetchable memory behind bridge: 00000000dfb00000-00000000dfefffff
	Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR-
	BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B-
		PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn-
	Capabilities: [88] Subsystem: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port
	Capabilities: [80] Power Management version 3
	Capabilities: [90] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [a0] Express (v2) Root Port (Slot+), MSI 00
	Capabilities: [100 v1] Virtual Channel
	Capabilities: [140 v1] Root Complex Link
	Capabilities: [d94 v1] #19
	Kernel driver in use: pcieport
Quoted 2 lines

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

It does not and that's exactly the problem. We must assume that the root port can redirect a transaction from a subordinate device back to another subordinate device without IOMMU translation when ACS support is not present. If you had a device plugged in below 00:01.0, we'd also need to assume that non-IOMMU translated peer-to-peer between devices behind either function, 00:01.0 or 00:01.1, is possible.

Intel has indicated that processor root ports for all Xeon class processors should support ACS and have verified isolation for PCH based root ports allowing us to support quirks in place of ACS support. I'm not aware of any efforts at Intel to verify isolation capabilities of root ports on client processors. They are however aware that lack of ACS is a limiting factor for usability of VT-d, and I hope that we'll see future products with ACS support.

Quoted 6 lines

Chances are good that the PCH root port at 00:1c.0 is supported by an ACS quirk, but it seems that your system has a PCIe switch below the root port. If the PCIe switch downstream ports support ACS, then you may be able to move the 82599 to the empty slot at bus 07 to separate the VFs into different IOMMU groups. Thanks,

Thanks, Alex,
how to tell whether a PCI bridge/deivce support ACS capability?

I perform "lspci -vvv -s | grep -i ACS", nothing matched.

# lspci -vvv -s 00:1c.0
00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) (prog-if 00 [Normal decode])
	Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx-
	Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
	Latency: 0, Cache Line Size: 64 bytes
	Bus: primary=00, secondary=05, subordinate=0b, sec-latency=0
	I/O behind bridge: 00002000-00003fff
	Memory behind bridge: f7800000-f7cfffff
	Prefetchable memory behind bridge: 00000000f0000000-00000000f03fffff
	Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR-
	BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B-
		PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn-
	Capabilities: [40] Express (v2) Root Port (Slot+), MSI 00
		DevCap:	MaxPayload 128 bytes, PhantFunc 0, Latency L0s <64ns, L1 <1us
			ExtTag- RBE+ FLReset-
		DevCtl:	Report errors: Correctable- Non-Fatal- Fatal- Unsupported-
			RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop-
			MaxPayload 128 bytes, MaxReadReq 128 bytes
		DevSta:	CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr+ TransPend-
		LnkCap:	Port #1, Speed 5GT/s, Width x4, ASPM L0s L1, Latency L0 <1us, L1 <4us
			ClockPM- Surprise- LLActRep+ BwNot-
		LnkCtl:	ASPM Disabled; RCB 64 bytes Disabled- Retrain- CommClk-
			ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt-
		LnkSta:	Speed 5GT/s, Width x4, TrErr- Train- SlotClk+ DLActive+ BWMgmt+ ABWMgmt+
		SltCap:	AttnBtn- PwrCtrl- MRL- AttnInd- PwrInd- HotPlug- Surprise-
			Slot #0, PowerLimit 25.000W; Interlock- NoCompl+
		SltCtl:	Enable: AttnBtn- PwrFlt- MRL- PresDet- CmdCplt- HPIrq- LinkChg-
			Control: AttnInd Unknown, PwrInd Unknown, Power- Interlock-
		SltSta:	Status: AttnBtn- PowerFlt- MRL- CmdCplt- PresDet+ Interlock-
			Changed: MRL- PresDet- LinkState-
		RootCtl: ErrCorrectable- ErrNon-Fatal- ErrFatal- PMEIntEna- CRSVisible-
		RootCap: CRSVisible-
		RootSta: PME ReqID 0000, PMEStatus- PMEPending-
		DevCap2: Completion Timeout: Range BC, TimeoutDis+ ARIFwd-
		DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis- ARIFwd-
		LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-, Selectable De-emphasis: -6dB
			 Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS-
			 Compliance De-emphasis: -6dB
		LnkSta2: Current De-emphasis Level: -6dB, EqualizationComplete-, EqualizationPhase1-
			 EqualizationPhase2-, EqualizationPhase3-, LinkEqualizationRequest-
	Capabilities: [80] MSI: Enable- Count=1/1 Maskable- 64bit-
		Address: 00000000  Data: 0000
	Capabilities: [90] Subsystem: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1
	Capabilities: [a0] Power Management version 2
		Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+)
		Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=0 PME-
	Kernel driver in use: pcieport

Thanks,
Zhang Haoyu

Quoted 1 line

Alex

#5 lore raw
Quoted 120 lines · Zhang Haoyu
Quoted 114 lines
Quoted 96 lines
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, ..., so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group?
If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

# lspci | grep Ether
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
02:00.1 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
08:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
08:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
09:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0a:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.0 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0b:00.1 Ethernet controller: Intel Corporation 82576 Gigabit Network Connection (rev 01)
0c:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10)

I want to direct-assign the VFs of intel 82599(02:00.0 or 02:00.1) to VM,

# lspci -t
-[0000:00]-+-00.0
           +-01.0-[01]--
           +-01.1-[02-03]--+-00.0
           |                      \-00.1
           +-02.0
           +-06.0-[04]--
           +-16.0
           +-1a.0
           +-1c.0-[05-0b]----00.0-[06-0b]--+-04.0-[07]--
           |                               +-05.0-[08]--+-00.0
           |                               |                  \-00.1
           |                               +-06.0-[09]--+-00.0
           |                               |                  \-00.1
           |                               +-08.0-[0a]--+-00.0
           |                               |                  \-00.1
           |                               \-09.0-[0b]--+-00.0
           |                                                  \-00.1
           +-1d.0
           +-1e.0-[0c]----00.0
           +-1f.0
           +-1f.2
           \-1f.3

lspci -vvv -s 02.00.0
02:00.0 Ethernet controller: Intel Corporation 82599EB 10-Gigabit SFI/SFP+ Network Connection (rev 01)
Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
Latency: 0, Cache Line Size: 64 bytes
Interrupt: pin A routed to IRQ 17
Region 0: Memory at f7e20000 (64-bit, non-prefetchable) [size=128K]
Region 2: I/O ports at e020 [size=32]
Region 4: Memory at f7e44000 (64-bit, non-prefetchable) [size=16K]
Capabilities: [40] Power Management version 3
Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+
Capabilities: [70] MSI-X: Enable+ Count=64 Masked-
Capabilities: [a0] Express (v2) Endpoint, MSI 00
Capabilities: [e0] Vital Product Data
Capabilities: [100 v1] Advanced Error Reporting
Capabilities: [140 v1] Device Serial Number 00-90-0b-ff-ff-29-33-c2
Capabilities: [150 v1] Alternative Routing-ID Interpretation (ARI)
Capabilities: [160 v1] Single Root I/O Virtualization (SR-IOV)
Kernel driver in use: ixgbe

# lspci -vvv -s 00:01.1
00:01.1 PCI bridge: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port (rev 09) (prog-if 00 [Normal decode])
	Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+
	Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
	Latency: 0, Cache Line Size: 64 bytes
	Bus: primary=00, secondary=02, subordinate=03, sec-latency=0
	I/O behind bridge: 0000e000-0000efff
	Memory behind bridge: f7e00000-f7efffff
	Prefetchable memory behind bridge: 00000000dfb00000-00000000dfefffff
	Secondary status: 66MHz- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- <SERR- <PERR-
	BridgeCtl: Parity- SERR- NoISA- VGA- MAbort- >Reset- FastB2B-
		PriDiscTmr- SecDiscTmr- DiscTmrStat- DiscTmrSERREn-
	Capabilities: [88] Subsystem: Intel Corporation Xeon E3-1200 v2/3rd Gen Core processor PCI Express Root Port
	Capabilities: [80] Power Management version 3
	Capabilities: [90] MSI: Enable+ Count=1/1 Maskable- 64bit-
	Capabilities: [a0] Express (v2) Root Port (Slot+), MSI 00
	Capabilities: [100 v1] Virtual Channel
	Capabilities: [140 v1] Root Complex Link
	Capabilities: [d94 v1] #19
	Kernel driver in use: pcieport
Quoted 2 lines

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

It does not and that's exactly the problem. We must assume that the root port can redirect a transaction from a subordinate device back to another subordinate device without IOMMU translation when ACS support is not present. If you had a device plugged in below 00:01.0, we'd also need to assume that non-IOMMU translated peer-to-peer between devices behind either function, 00:01.0 or 00:01.1, is possible.

Intel has indicated that processor root ports for all Xeon class processors should support ACS and have verified isolation for PCH based root ports allowing us to support quirks in place of ACS support. I'm not aware of any efforts at Intel to verify isolation capabilities of root ports on client processors. They are however aware that lack of ACS is a limiting factor for usability of VT-d, and I hope that we'll see future products with ACS support.

Quoted 6 lines

Chances are good that the PCH root port at 00:1c.0 is supported by an ACS quirk, but it seems that your system has a PCIe switch below the root port. If the PCIe switch downstream ports support ACS, then you may be able to move the 82599 to the empty slot at bus 07 to separate the VFs into different IOMMU groups. Thanks,

Quoted 6 lines

Thanks, Alex,
how to tell whether a PCI bridge/deivce support ACS capability?

I perform "lspci -vvv -s | grep -i ACS", nothing matched.

# lspci -vvv -s 00:1c.0
00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) (prog-if 00 [Normal decode])

Ideally there would be capabilities for it, something like:

Capabilities [xxx] Access Control Services...

But, Intel failed to provide this, so we enable "effective" ACS capabilities via a quirk:

drivers/pci/quirks.c:
/*
* Many Intel PCH root ports do provide ACS-like features to disable peer
* transactions and validate bus numbers in requests, but do not provide an
* actual PCIe ACS capability. This is the list of device IDs known to fall
* into that category as provided by Intel in Red Hat bugzilla 1037684. */

static const u16 pci_quirk_intel_pch_acs_ids[] = {
        /* Ibexpeak PCH */
        0x3b42, 0x3b43, 0x3b44, 0x3b45, 0x3b46, 0x3b47, 0x3b48, 0x3b49,
        0x3b4a, 0x3b4b, 0x3b4c, 0x3b4d, 0x3b4e, 0x3b4f, 0x3b50, 0x3b51,
        /* Cougarpoint PCH */
        0x1c10, 0x1c11, 0x1c12, 0x1c13, 0x1c14, 0x1c15, 0x1c16, 0x1c17,
        0x1c18, 0x1c19, 0x1c1a, 0x1c1b, 0x1c1c, 0x1c1d, 0x1c1e, 0x1c1f,
        /* Pantherpoint PCH */
        0x1e10, 0x1e11, 0x1e12, 0x1e13, 0x1e14, 0x1e15, 0x1e16, 0x1e17,
        0x1e18, 0x1e19, 0x1e1a, 0x1e1b, 0x1e1c, 0x1e1d, 0x1e1e, 0x1e1f,
        /* Lynxpoint-H PCH */
        0x8c10, 0x8c11, 0x8c12, 0x8c13, 0x8c14, 0x8c15, 0x8c16, 0x8c17,
        0x8c18, 0x8c19, 0x8c1a, 0x8c1b, 0x8c1c, 0x8c1d, 0x8c1e, 0x8c1f,
        /* Lynxpoint-LP PCH */
        0x9c10, 0x9c11, 0x9c12, 0x9c13, 0x9c14, 0x9c15, 0x9c16, 0x9c17,
        0x9c18, 0x9c19, 0x9c1a, 0x9c1b,
        /* Wildcat PCH */
        0x9c90, 0x9c91, 0x9c92, 0x9c93, 0x9c94, 0x9c95, 0x9c96, 0x9c97,
        0x9c98, 0x9c99, 0x9c9a, 0x9c9b,
        /* Patsburg (X79) PCH */
        0x1d10, 0x1d12, 0x1d14, 0x1d16, 0x1d18, 0x1d1a, 0x1d1c, 0x1d1e,
};

Hopefully if you run 'lspci -n', you'll see your device ID listed among these. We don't currently have any quirks for PCIe switches, so if your IOMMU group is still bigger than it should be, that may be the reason. Thanks,

Alex

#6 lore raw
Quoted 86 lines
Quoted 41 lines
Quoted 35 lines
Quoted 17 lines
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group? If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

Quoted 2 lines

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

It does not and that's exactly the problem. We must assume that the root port can redirect a transaction from a subordinate device back to another subordinate device without IOMMU translation when ACS support is not present. If you had a device plugged in below 00:01.0, we'd also need to assume that non-IOMMU translated peer-to-peer between devices behind either function, 00:01.0 or 00:01.1, is possible.

Intel has indicated that processor root ports for all Xeon class processors should support ACS and have verified isolation for PCH based root ports allowing us to support quirks in place of ACS support. I'm not aware of any efforts at Intel to verify isolation capabilities of root ports on client processors. They are however aware that lack of ACS is a limiting factor for usability of VT-d, and I hope that we'll see future products with ACS support.

Quoted 6 lines

Chances are good that the PCH root port at 00:1c.0 is supported by an ACS quirk, but it seems that your system has a PCIe switch below the root port. If the PCIe switch downstream ports support ACS, then you may be able to move the 82599 to the empty slot at bus 07 to separate the VFs into different IOMMU groups. Thanks,

Quoted 6 lines

Thanks, Alex,
how to tell whether a PCI bridge/deivce support ACS capability?

I perform "lspci -vvv -s | grep -i ACS", nothing matched.

# lspci -vvv -s 00:1c.0
00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) (prog-if 00 [Normal decode])

Ideally there would be capabilities for it, something like:

Capabilities [xxx] Access Control Services...

But, Intel failed to provide this, so we enable "effective" ACS capabilities via a quirk:

drivers/pci/quirks.c:
/*
* Many Intel PCH root ports do provide ACS-like features to disable peer
* transactions and validate bus numbers in requests, but do not provide an
* actual PCIe ACS capability. This is the list of device IDs known to fall
* into that category as provided by Intel in Red Hat bugzilla 1037684. */

static const u16 pci_quirk_intel_pch_acs_ids[] = {
       /* Ibexpeak PCH */
       0x3b42, 0x3b43, 0x3b44, 0x3b45, 0x3b46, 0x3b47, 0x3b48, 0x3b49,
       0x3b4a, 0x3b4b, 0x3b4c, 0x3b4d, 0x3b4e, 0x3b4f, 0x3b50, 0x3b51,
       /* Cougarpoint PCH */
       0x1c10, 0x1c11, 0x1c12, 0x1c13, 0x1c14, 0x1c15, 0x1c16, 0x1c17,
       0x1c18, 0x1c19, 0x1c1a, 0x1c1b, 0x1c1c, 0x1c1d, 0x1c1e, 0x1c1f,
       /* Pantherpoint PCH */
       0x1e10, 0x1e11, 0x1e12, 0x1e13, 0x1e14, 0x1e15, 0x1e16, 0x1e17,
       0x1e18, 0x1e19, 0x1e1a, 0x1e1b, 0x1e1c, 0x1e1d, 0x1e1e, 0x1e1f,
       /* Lynxpoint-H PCH */
       0x8c10, 0x8c11, 0x8c12, 0x8c13, 0x8c14, 0x8c15, 0x8c16, 0x8c17,
       0x8c18, 0x8c19, 0x8c1a, 0x8c1b, 0x8c1c, 0x8c1d, 0x8c1e, 0x8c1f,
       /* Lynxpoint-LP PCH */
       0x9c10, 0x9c11, 0x9c12, 0x9c13, 0x9c14, 0x9c15, 0x9c16, 0x9c17,
       0x9c18, 0x9c19, 0x9c1a, 0x9c1b,
       /* Wildcat PCH */
       0x9c90, 0x9c91, 0x9c92, 0x9c93, 0x9c94, 0x9c95, 0x9c96, 0x9c97,
       0x9c98, 0x9c99, 0x9c9a, 0x9c9b,
       /* Patsburg (X79) PCH */
       0x1d10, 0x1d12, 0x1d14, 0x1d16, 0x1d18, 0x1d1a, 0x1d1c, 0x1d1e,
};
Quoted 5 lines

Hopefully if you run 'lspci -n', you'll see your device ID listed among these. We don't currently have any quirks for PCIe switches, so if your IOMMU group is still bigger than it should be, that may be the reason. Thanks,

Using device specific mechanisms to enable and verify ACS-like capability is okay, but with regard to those devices which completely don't support ACS-like capabilities, what shall we do, how about applying the [PATCH] pci: Enable overrides for missing ACS capabilities, and how to reduce the risk of data corruption and info leakage between VMs?

Thanks,
Zhang Haoyu

Quoted 1 line

Alex

#7 lore raw
Quoted 91 lines
Quoted 86 lines
Quoted 41 lines
Quoted 35 lines
Quoted 17 lines
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group? If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

Quoted 2 lines

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

It does not and that's exactly the problem. We must assume that the root port can redirect a transaction from a subordinate device back to another subordinate device without IOMMU translation when ACS support is not present. If you had a device plugged in below 00:01.0, we'd also need to assume that non-IOMMU translated peer-to-peer between devices behind either function, 00:01.0 or 00:01.1, is possible.

Intel has indicated that processor root ports for all Xeon class processors should support ACS and have verified isolation for PCH based root ports allowing us to support quirks in place of ACS support. I'm not aware of any efforts at Intel to verify isolation capabilities of root ports on client processors. They are however aware that lack of ACS is a limiting factor for usability of VT-d, and I hope that we'll see future products with ACS support.

Quoted 6 lines

Chances are good that the PCH root port at 00:1c.0 is supported by an ACS quirk, but it seems that your system has a PCIe switch below the root port. If the PCIe switch downstream ports support ACS, then you may be able to move the 82599 to the empty slot at bus 07 to separate the VFs into different IOMMU groups. Thanks,

Quoted 6 lines

Thanks, Alex,
how to tell whether a PCI bridge/deivce support ACS capability?

I perform "lspci -vvv -s | grep -i ACS", nothing matched.

# lspci -vvv -s 00:1c.0
00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) (prog-if 00 [Normal decode])

Ideally there would be capabilities for it, something like:

Capabilities [xxx] Access Control Services...

But, Intel failed to provide this, so we enable "effective" ACS capabilities via a quirk:

drivers/pci/quirks.c:
/*
* Many Intel PCH root ports do provide ACS-like features to disable peer
* transactions and validate bus numbers in requests, but do not provide an
* actual PCIe ACS capability. This is the list of device IDs known to fall
* into that category as provided by Intel in Red Hat bugzilla 1037684. */

static const u16 pci_quirk_intel_pch_acs_ids[] = {
       /* Ibexpeak PCH */
       0x3b42, 0x3b43, 0x3b44, 0x3b45, 0x3b46, 0x3b47, 0x3b48, 0x3b49,
       0x3b4a, 0x3b4b, 0x3b4c, 0x3b4d, 0x3b4e, 0x3b4f, 0x3b50, 0x3b51,
       /* Cougarpoint PCH */
       0x1c10, 0x1c11, 0x1c12, 0x1c13, 0x1c14, 0x1c15, 0x1c16, 0x1c17,
       0x1c18, 0x1c19, 0x1c1a, 0x1c1b, 0x1c1c, 0x1c1d, 0x1c1e, 0x1c1f,
       /* Pantherpoint PCH */
       0x1e10, 0x1e11, 0x1e12, 0x1e13, 0x1e14, 0x1e15, 0x1e16, 0x1e17,
       0x1e18, 0x1e19, 0x1e1a, 0x1e1b, 0x1e1c, 0x1e1d, 0x1e1e, 0x1e1f,
       /* Lynxpoint-H PCH */
       0x8c10, 0x8c11, 0x8c12, 0x8c13, 0x8c14, 0x8c15, 0x8c16, 0x8c17,
       0x8c18, 0x8c19, 0x8c1a, 0x8c1b, 0x8c1c, 0x8c1d, 0x8c1e, 0x8c1f,
       /* Lynxpoint-LP PCH */
       0x9c10, 0x9c11, 0x9c12, 0x9c13, 0x9c14, 0x9c15, 0x9c16, 0x9c17,
       0x9c18, 0x9c19, 0x9c1a, 0x9c1b,
       /* Wildcat PCH */
       0x9c90, 0x9c91, 0x9c92, 0x9c93, 0x9c94, 0x9c95, 0x9c96, 0x9c97,
       0x9c98, 0x9c99, 0x9c9a, 0x9c9b,
       /* Patsburg (X79) PCH */
       0x1d10, 0x1d12, 0x1d14, 0x1d16, 0x1d18, 0x1d1a, 0x1d1c, 0x1d1e,
};
Quoted 5 lines

Hopefully if you run 'lspci -n', you'll see your device ID listed among these. We don't currently have any quirks for PCIe switches, so if your IOMMU group is still bigger than it should be, that may be the reason. Thanks,

Quoted 5 lines

Using device specific mechanisms to enable and verify ACS-like capability is okay, but with regard to those devices which completely don't support ACS-like capabilities, what shall we do, how about applying the [PATCH] pci: Enable overrides for missing ACS capabilities, and how to reduce the risk of data corruption and info leakage between VMs?

Any update compared with http://thread.gmane.org/gmane.comp.emulators.kvm.devel/110726/focus=111515 ?

Quoted 3 lines

Thanks,
Zhang Haoyu

Quoted 1 line

Alex

#8 lore raw
Quoted 91 lines · Zhang Haoyu
Quoted 91 lines
Quoted 91 lines
Quoted 41 lines
Quoted 35 lines
Quoted 17 lines
Quoted 9 lines
Quoted 8 lines

Hi, all
I'm using VFIO to assign intel 82599 VF to VM, now I encounter a problem,
82599 PF and its VFs belong to the same iommu_group, but I only want to assign some VFs to one VM, and some other VFs to another VM, so how to only unbind (part of) the VFs but PF?
I read the kernel doc vfio.txt, I'm not sure should I unbind all of the devices which belong to one iommu_group? If so, because PF and its VFs belong to the same iommu_group, if I unbind the PF, its VFs also diappeared.
I think I misunderstand someting,
any advises?

Quoted 8 lines

This occurs when the PF is installed behind components in the system that do not support PCIe Access Control Services (ACS). The IOMMU group contains both the PF and the VF because upstream transactions can be re-routed downstream by these non-ACS components before being translated by the IOMMU. Please provide 'sudo lspci -vvv', 'lspci -n', and kernel version and we might be able to give you some advise on how to work around the problem. Thanks,

Quoted 2 lines

The intel 82599(02:00.0 or 02:00.1) is behind the pci bridge (00:01.1), does 00:01.1 PCI bridge support ACS ?

It does not and that's exactly the problem. We must assume that the root port can redirect a transaction from a subordinate device back to another subordinate device without IOMMU translation when ACS support is not present. If you had a device plugged in below 00:01.0, we'd also need to assume that non-IOMMU translated peer-to-peer between devices behind either function, 00:01.0 or 00:01.1, is possible.

Intel has indicated that processor root ports for all Xeon class processors should support ACS and have verified isolation for PCH based root ports allowing us to support quirks in place of ACS support. I'm not aware of any efforts at Intel to verify isolation capabilities of root ports on client processors. They are however aware that lack of ACS is a limiting factor for usability of VT-d, and I hope that we'll see future products with ACS support.

Quoted 6 lines

Chances are good that the PCH root port at 00:1c.0 is supported by an ACS quirk, but it seems that your system has a PCIe switch below the root port. If the PCIe switch downstream ports support ACS, then you may be able to move the 82599 to the empty slot at bus 07 to separate the VFs into different IOMMU groups. Thanks,

Quoted 6 lines

Thanks, Alex,
how to tell whether a PCI bridge/deivce support ACS capability?

I perform "lspci -vvv -s | grep -i ACS", nothing matched.

# lspci -vvv -s 00:1c.0
00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5) (prog-if 00 [Normal decode])

Ideally there would be capabilities for it, something like:

Capabilities [xxx] Access Control Services...

But, Intel failed to provide this, so we enable "effective" ACS capabilities via a quirk:

drivers/pci/quirks.c:
/*
* Many Intel PCH root ports do provide ACS-like features to disable peer
* transactions and validate bus numbers in requests, but do not provide an
* actual PCIe ACS capability. This is the list of device IDs known to fall
* into that category as provided by Intel in Red Hat bugzilla 1037684. */

static const u16 pci_quirk_intel_pch_acs_ids[] = {
       /* Ibexpeak PCH */
       0x3b42, 0x3b43, 0x3b44, 0x3b45, 0x3b46, 0x3b47, 0x3b48, 0x3b49,
       0x3b4a, 0x3b4b, 0x3b4c, 0x3b4d, 0x3b4e, 0x3b4f, 0x3b50, 0x3b51,
       /* Cougarpoint PCH */
       0x1c10, 0x1c11, 0x1c12, 0x1c13, 0x1c14, 0x1c15, 0x1c16, 0x1c17,
       0x1c18, 0x1c19, 0x1c1a, 0x1c1b, 0x1c1c, 0x1c1d, 0x1c1e, 0x1c1f,
       /* Pantherpoint PCH */
       0x1e10, 0x1e11, 0x1e12, 0x1e13, 0x1e14, 0x1e15, 0x1e16, 0x1e17,
       0x1e18, 0x1e19, 0x1e1a, 0x1e1b, 0x1e1c, 0x1e1d, 0x1e1e, 0x1e1f,
       /* Lynxpoint-H PCH */
       0x8c10, 0x8c11, 0x8c12, 0x8c13, 0x8c14, 0x8c15, 0x8c16, 0x8c17,
       0x8c18, 0x8c19, 0x8c1a, 0x8c1b, 0x8c1c, 0x8c1d, 0x8c1e, 0x8c1f,
       /* Lynxpoint-LP PCH */
       0x9c10, 0x9c11, 0x9c12, 0x9c13, 0x9c14, 0x9c15, 0x9c16, 0x9c17,
       0x9c18, 0x9c19, 0x9c1a, 0x9c1b,
       /* Wildcat PCH */
       0x9c90, 0x9c91, 0x9c92, 0x9c93, 0x9c94, 0x9c95, 0x9c96, 0x9c97,
       0x9c98, 0x9c99, 0x9c9a, 0x9c9b,
       /* Patsburg (X79) PCH */
       0x1d10, 0x1d12, 0x1d14, 0x1d16, 0x1d18, 0x1d1a, 0x1d1c, 0x1d1e,
};

Hopefully if you run 'lspci -n', you'll see your device ID listed among these. We don't currently have any quirks for PCIe switches, so if your IOMMU group is still bigger than it should be, that may be the reason. Thanks,

Quoted 6 lines
Quoted 5 lines

Using device specific mechanisms to enable and verify ACS-like capability is okay, but with regard to those devices which completely don't support ACS-like capabilities, what shall we do, how about applying the [PATCH] pci: Enable overrides for missing ACS capabilities, and how to reduce the risk of data corruption and info leakage between VMs?

Any update compared with http://thread.gmane.org/gmane.comp.emulators.kvm.devel/110726/focus=111515 ?

You're welcome to use that patch, but you do so at your own risk. Upstream is not willing to accept that patch because incorrectly assuming isolation can lead to subtle issues which are difficult or impossible to support. This is why we only support ACS reported isolation or vendor verified quirks. If you're able to work with the component vendor to verify isolation, we'd welcome more quirks in this area. Thanks,

Alex