net: phy: fix phy device autoneg wrong value
Subsystems (3)
PATCH 1/1 net: phy: fix phy device autoneg wrong value
In phy_device_create, autoneg is set to AUTONEG_ENABLE. When using the generic phy driver (phy_device.c), genphy_config_init reads BMSR and finds out if autonegotiation is possible and sets the phy device features accordingly. phy_sanitize_settings is supposed to set the right value of autoneg, but it is never called if autonegotiation is enabled, which is always the case.
--- drivers/net/phy/phy.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)
drivers/net/phy/phy.c +0 -0
@@ -249,9 +249,6 @@ static void phy_sanitize_settings(struct phy_device
*phydev)
unsigned int idx;
/* Sanitize settings based on PHY capabilities */
- if ((features & SUPPORTED_Autoneg) == 0)
- phydev->autoneg = AUTONEG_DISABLE;
-
idx = phy_find_valid(phy_find_setting(phydev->speed, phydev->duplex),
features);
@@ -436,6 +433,9 @@ int phy_start_aneg(struct phy_device *phydev)
mutex_lock(&phydev->lock);
+ if ((phydev->supported & SUPPORTED_Autoneg) == 0)
+ phydev->autoneg = AUTONEG_DISABLE;
+
if (AUTONEG_DISABLE == phydev->autoneg)
phy_sanitize_settings(phydev);
Signature · 1 line