clk samsung exynos5420 add CLK_RECALC_NEW_RATES flag to mout_apll and mout_kpll clock.
Subsystems (3)
PATCH 1/1 clk samsung exynos5420 add CLK_RECALC_NEW_RATES flag to mout_apll and mout_kpll clock.
Addition of CLK_RECALC_NEW_RATES flag to support Exynos5 cpu clk so that correct divider values are re-calculated after both pre/post clock notifiers had run for for mout_apll clock and mout_kpll clock.
Depend on https://lkml.org/lkml/2015/4/3/388
Tested on OdroidXU3 Board.
--- drivers/clk/samsung/clk-exynos5420.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
drivers/clk/samsung/clk-exynos5420.c +2 -2
@@ -618,10 +618,10 @@ static struct samsung_mux_clock exynos5x_mux_clks[] __initdata = {MUX (0 ,"mout_mspll_cpu" , mout_mspll_cpu_p,SRC_TOP7 ,12 ,2 ),MUX_F (0 ,"mout_apll" , mout_apll_p,SRC_CPU ,0 ,1 , -CLK_SET_RATE_PARENT ,0 ), +CLK_SET_RATE_PARENT |CLK_RECALC_NEW_RATES ,0 ),MUX (0 ,"mout_cpu" , mout_cpu_p,SRC_CPU ,16 ,1 ),MUX_F (0 ,"mout_kpll" , mout_kpll_p,SRC_KFC ,0 ,1 , -CLK_SET_RATE_PARENT ,0 ), +CLK_SET_RATE_PARENT |CLK_RECALC_NEW_RATES ,0 ),MUX (0 ,"mout_kfc" , mout_kfc_p,SRC_KFC ,16 ,1 ), MUX(0, "mout_aclk200", mout_group1_p, SRC_TOP0, 8, 2),
Signature · 1 line
1.9.1
2015-05-08 2:48 GMT+09:00 Anand Moon <[email protected]>:
Quoted 3 lines
Addition of
CLK_RECALC_NEW_RATESflag to support Exynos5 cpu clk so that correct divider values are re-calculated after both pre/post clock notifiers had run for formout_apllclock andmout_kpllclock.
s/for for/for/
Could you precise in commit message the observational effects *without* this patch? In other words: what is fixed? The divider will have incorrect values?
Quoted 4 lines
Depend on https://lkml.org/lkml/2015/4/3/388
Tested on OdroidXU3 Board.
Thanks for providing this information. However
1. Patch dependency should not be part of commit message, It simply won't provide any meaningful information when they are merged.
2. Similarly testing platform also is not always put in commit message.
So just put them after separator (triple-dash).
After fixing the commit message:
Best regards,
Krzysztof
Hi Krysztof,
Actually the patch is based on https://lkml.org/lkml/2015/4/3/389
I don't know how to measure the energy consumption when compared to cpufreq-exynos.
I will update the commit log and resend it with you review.
-Anand Moon
Quoted 27 lines · Krzysztof Kozlowski
2015-05-08 2:48 GMT+09:00 Anand Moon <[email protected]>:
Quoted 3 lines
Addition of
CLK_RECALC_NEW_RATESflag to support Exynos5 cpu clk so that correct divider values are re-calculated after both pre/post clock notifiers had run for formout_apllclock andmout_kpllclock.s/for for/for/
Could you precise in commit message the observational effects *without* this patch? In other words: what is fixed? The divider will have incorrect values?
Quoted 4 lines
Depend on https://lkml.org/lkml/2015/4/3/388
Tested on OdroidXU3 Board.
Thanks for providing this information. However
1. Patch dependency should not be part of commit message, It simply won't provide any meaningful information when they are merged.
2. Similarly testing platform also is not always put in commit message.So just put them after separator (triple-dash).
After fixing the commit message:
Reviewed-by Krzysztof Kozlowski <[email protected]>Best regards,
Krzysztof
Quoted 5 lines · Anand Moon
Hi Krysztof,
Actually the patch is based on https://lkml.org/lkml/2015/4/3/389
I don't know how to measure the energy consumption when compared to cpufreq-exynos.
It does not have to be energy consumption. It may be something else visible, like wrong values for clock rates. I don't know, it is your patch so you should know *what is fixed* (or changed).
Best regards,
Krzysztof