Xen on ARM vITS Handling
Here follows draft C based on previous feedback.
Also at:
http://xenbits.xen.org/people/ianc/vits/draftC.{pdf,html}
I think I've captured most of the previous discussion, except where explicitly noted by XXX or in other replies, but please do point out places where I've missed something.
One area where I am pretty sure I've dropped the ball is on the completion and update of CREADR. That conversation ended up bifurcating along the 1:N vs N:N mapping scheme lines, and I didn't manage to get the various proposals straight. Since we've now agreed on N:N hopefully we can reach a conclusion (no pun intended) on the completion aspect too (sorry that this probably means rehasing at least a subset of the previous thread).
Ian.
% Xen on ARM vITS Handling
% Ian Campbell <[email protected]>
% Draft C
# Changelog
## Since Draft B
* Details of command translation (thanks to Julien and Vijay)
* Added background on LPI Translation and Pending tablesd
* Added background on Collections
* Settled on N:N scheme for vITS:pITS mapping.
* Rejigged section nesting a bit.
* Since we now thing translation should be cheap, settle on translation at scheduling time.
* Lazy INVALL and SYNC
## Since Draft A
* Added discussion of when/where command translation occurs.
* Contention on scheduler lock, suggestion to use SOFTIRQ.
* Handling of domain shutdown.
* More detailed discussion of multiple vs single vits pros/cons.
# Introduction
ARM systems containing a GIC version 3 or later may contain one or more ITS logical blocks. An ITS is used to route Message Signalled interrupts from devices into an LPI injection on the processor.
The following summarises the ITS hardware design and serves as a set of assumptions for the vITS software design. (XXX it is entirely possible I've horribly misunderstood how this stuff fits together). For full details of the ITS see the "GIC Architecture Specification".
## Device Identifiers
Each device using the ITS is associated with a unique identifier.
The device IDs are typically described via system firmware, e.g. the ACPI IORT table or via device tree.
The number of device ids is variable and can be discovered via GITS_TYPER.Devbits. This field allows an ITS to have up to 2^32 device.
## Interrupt Collections
Each interrupt is a member of an Interrupt Collection. This allows software to manage large numbers of physical interrupts with a small number of commands rather than issuing one command per interrupt.
On a system with N processors, the ITS must provide at least N+1 collections.
## Target Addresses
The Target Address correspond to a specific GIC re-distributor. The format of this field depends on the value of the GITS_TYPER.PTA bit:
* 1: the base address of the re-distributor target is used
* 0: a unique processor number is used. The mapping between the processor affinity value (MPIDR) and the processor number is discoverable via GICR_TYPER.ProcessorNumber.
## ITS Translation Table
Message signalled interrupts are translated into an LPI via an ITS translation table which must be configured for each device which can generate an MSI.
The ITS translation table maps the device id of the originating devic into an Interrupt Collection and then into a target address.
## ITS Configuration
The ITS is configured and managed, including establishing and configuring Translation Table for each device, via an in memory ring shared between the CPU and the ITS controller. The ring is managed via the GITS_CBASER register and indexed by GITS_CWRITER and GITS_CREADR registers.
A processor adds commands to the shared ring and then updates GITS_CWRITER to make them visible to the ITS controller.
The ITS controller processes commands from the ring and then updates GITS_CREADR to indicate the the processor that the command has been processed.
Commands are processed sequentially.
Commands sent on the ring include operational commands:
* Routing interrupts to processors;
* Generating interrupts;
* Clearing the pending state of interrupts;
* Synchronising the command queue
and maintenance commands:
* Map device/collection/processor;
* Map virtual interrupt;
* Clean interrupts;
* Discard interrupts;
The field GITS_CBASER.Size encodes the number of 4KB pages minus 0 consisting of the command queue. This field is 8 bits which means the maximum size is 2^8 * 4KB = 1MB. Given that each command is 32 bytes, there is a maximum of 32768 commands in the queue.
The ITS provides no specific completion notification mechanism. Completion is monitored by a combination of a SYNC command and either polling GITS_CREADR or notification via an interrupt generated via the INT command.
Note that the interrupt generation via INT requires an originating device ID to be supplied (which is then translated via the ITS into an LPI). No specific device ID is defined for this purpose and so the OS software is expected to fabricate one.
Possible ways of inventing such a device ID are:
* Enumerate all device ids in the system and pick another one;
* Use a PCI BDF associated with a non-existent device function (such as an unused one relating to the PCI root-bridge) and translate that (via firmware tables) into a suitable device id;
* ???
## LPI Configuration Table
Each LPI has an associated configuration byte in the LPI Configuration Table (managed via the GIC Redistributor and placed at GICR_PROPBASER or GICR_VPROPBASER). This byte configures:
* The LPI's priority;
* Whether the LPI is enabled or disabled.
Software updates the Configuration Table directly but must then issue an invalidate command (per-device INV ITS command, global INVALL ITS command or write GICR_INVLPIR) for the affect to be guaranteed to become visible (possibly requiring an ITS SYNC command to ensure completion of the INV or INVALL). Note that it is valid for an implementaiton to reread the configuration table at any time (IOW it is _not_ guarenteed that a change to the LPI Configuration Table won't be visible until an invalidate is issued).
## LPI Pending Table
Each LPI also has an associated bit in the LPI Pending Table (managed by the GIC redistributor). This bit signals whether the LPI is pending or not.
# vITS
A guest domain which is allowed to use ITS functionality (i.e. has been assigned pass-through devices which can generate MSIs) will be presented with a virtualised ITS.
Accesses to the vITS registers will trap to Xen and be emulated and a virtualised Command Queue will be provided.
Commands entered onto the virtual Command Queue will be translated into physical commands, as described later in this document.
XXX there are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are not currently considered here. XXX Should they be/do they need to be?
# Requirements
Emulation should not block in the hypervisor for extended periods. In particular Xen should not busy wait on the physical ITS. Doing so blocks the physical CPU from doing anything else (such as scheduling other VCPUS)
There may be multiple guests which have a vITS, all targeting the same underlying pITS. A single guest VCPU should not be able to monopolise the pITS via its vITS and all guests should be able to make forward progress.
# vITS to pITS mapping
A physical system may have multiple physical ITSs.
We assume that a given device is only associated with one pITS.
A guest which is given access to multiple devices associated with multiple pITSs will need to be given virtualised access to all associated pITSs.
There are several possible models for achieving this:
* 1:N: One virtual ITS tired to multiple physical ITS.
* N:N: One virtual ITS per physical ITS.
* M:N: Multiple virtual ITS tied to a differing number of physical ITSs.
This design assumes an N:N model, which is thought to be simpler on the Xen side since it avoids questions of how to fairly schedule commands in the 1:N model while avoiding starvation as well as simplifying the virtualisation of global commands such as INVALL or SYNC.
The N:N model is also a better fit for I/O NUMA systems.
Since the choice of model is internal to the hypervisor/tools and is communicated to the guest via firmware tables we are not tied to this model as an ABI if we decide to change.
New toolstack domctls or extension to existing domctls will likely be required to allow the toolstack to determine the number of vITS which will be required for the guest and to determine the mapping for passed-through devices.
# LPI Configuration Table Virtualistion
A guest's write accesses to its LPI Configuration Table (which is just an area of guest RAM which the guest has nominated) will be trapped to the hypervisor, using stage 2 MMU permissions, in order for changes to be propagated into the physical LPI Configuration Table.
A host wide LPI dirty bit map, with 1 bit per LPI, will be maintained which indicates whether an update to the physical LPI Configuration Table has been flushed (via an invalidate command). The corresponding bit will be set whenever a guest changes the configuration of an LPI.
This dirty bit map will be used during the handling of relevant ITS Commands (INV, INVALL etc).
Note that no invalidate is required during the handling of an LPI Configuration Table trap.
# Command Queue Virtualisation
The command queue of each vITS is represented by a data structure:
struct vits_cq {
list_head schedule_list; /* Queued onto pits.schedule_list */
uint32_t creadr; /* Virtual creadr */
uint32_t cwriter; /* Virtual cwriter */
uint32_t progress; /* Index of last command queued to pits */
[ Reference to command queue memory ]
};
Each pITS has an associated data structure:
struct pits {
list_head schedule_list; /* Contains list of vitq_cq.schedule_lists */
uint32_t last_creadr;
};On write to the virtual CWRITER the cwriter field is updated and if that results in there being new outstanding requests then the vits_cq is enqueued onto pITS' schedule_list (unless it is already there).
On read from the virtual CREADR iff the vits_cq is such that commands are outstanding then a scheduling pass is attempted (in order to update vits_cq.creadr). The current value of vitq_cq.creadr is then returned.
## Command translation
In order to virtualise the Command Queue each command must be translated (this is described in the GIC spec).
Translation of certain commands is potentially expensive, however we will attempt to arrange things (data structures etc) such that the overhead a translation time is minimised (see later).
Translation can be done in two places:
* During scheduling.
* On write to CWRITER, into a per vits_cq queue which the scheduler then propagates to the pits.
Doing the translate during scheduling means that potentially expensive operations may be accounted to current, who may have nothing to do with those operations (this is true whether it is IRQ context or SOFTIRQ context).
Doing the translate during CWRITER emulation accounts it to the right place, but introduces a potentially long synchronous operation which ties down a VCPU. Introducing batching here means we have essentially the same issue wrt when to replenish the translated queue as doing translate during scheduling.
Translate during CWRITER also has memory overheads. Unclear if they are at a problematic scale or not.
Since we have arranged for translation overheads to be minimised it seems that translation during scheduling should be tollerable.
## pITS Scheduling
A pITS scheduling pass is attempted:
* On write to any virtual CWRITER iff that write results in there being new outstanding requests for that vits;
* On read from a virtual CREADR iff there are commands outstanding on that vits;
* On receipt of an interrupt notification arising from Xen's own use of INT; (see discussion under Completion)
* On any interrupt injection arising from a guests use of the INT command; (XXX perhaps, see discussion under Completion)
This may result in lots of contention on the scheduler locking. Therefore we consider that in each case all which happens is triggering of a softirq which will be processed on return to guest, and just once even for multiple events.
Such deferral could be considered OK (XXX ???) for the CREADR case because at worst the value read will be one cycle out of date. A guest which receives an INT notification might reasonably expect a subsequent read of CREADR to reflect that. However that should be covered by the softint processing which would occur on entry to the guest to inject the INT.
Each scheduling pass will:
* Read the physical CREADR;
* For each command between pits.last_creadr and the new CREADR value process completion of that command and update the corresponding vits_cq.creadr.
* Attempt to refill the pITS Command Queue (see below).
## Domain Shutdown
We can't free a vits_cq while has things on the physical control queue, and we cannot cancel things which are on the control queue.
So we must wait.
Obviously don't enqueue anything new onto the pits if d->is_dying.
domain_relinquish_resources() waits (somehow, with suitable continuations etc) for anything which the vits_cq has outstanding to be completed so that the datastructures can be cleared.
## Filling the pITS Command Queue.
Various algorithms could be used here. For now a simple proposal is to traverse the pits.schedule_list starting from where the last refill finished (i.e not from the top of the list each time).
In order to simplify bookkeeping and to bound the amount of time spent on a single scheduling pass each vitq_cq will only have a single batch of commands enqueued with the PITs at a time.
If a vits_cq has no pending commands then it is removed from the list.
If a vits_cq already has commands enqueued with the pITS Command Queue then it is skipped.
If a vits_cq has some pending commands then min(pits-free-slots, vits-outstanding, VITS_BATCH_SIZE) will be taken from the vITS command queue, translated and placed onto the pITS queue. vits_cq.progress will be updated to reflect this.
Each vits_cq is handled in turn in this way until the pITS Command Queue is full, there are no more outstanding commands or each active vits_cq has commands enqueued with the pITS.
There will likely need to be a data structure which shadows the pITS Command Queue slots with references to the vits_cq which has a command currently occupying that slot and corresponding the index into the virtual command queue, for use when completing a command.
VITS_BATCH_SIZE should be small, TBD say 4 or 8.
## Completion
It is expected that commands will normally be completed (resulting in an update of the corresponding vits_cq.creadr) via guest read from CREADR. This will trigger a scheduling pass which will ensure the vits_cq.creadr value is up to date before it is returned.
A guest which does completion via the use of INT cannot observe CREADR without reading it, so updating on read from CREADR suffices from the point of view of the guests observation of the state. (Of course we will inject the interrupt at the designated point and the guest may well then read CREADR)
However in order to keep the pITS Command Queue moving along we need to consider what happens if there are no INT based events nor reads from CREADR to drive completion and therefore refilling of the Queue with other outstanding commands.
A guest which enqueues some commands and then never checks for completion cannot itself block things because any other guest which reads CREADR will drive completion. However if _no_ guest reads from CREADR then completion will not occur and this must be dealt with.
Even if we include completion on INT-base interrupt injection then it is possible that the pITS queue may not contain any such interrupts, either because no guest is using them or because the batching means that none of them are enqueued on the active ring at the moment.
So we need a fallback to ensure that queue keeps moving. There are several options:
* A periodic timer in Xen which runs whenever there are outstanding commands in the pITS. This is simple but pretty sucky.
* Xen injects its own INT commands into the pITS ring. This requires figuring out a device ID to use.
The second option is likely to be preferable if the issue of selecting a device ID can be addressed.
A secondary question is when these INT commands should be inserted into the command stream:
* After each batch taken from a single vits_cq;
* After each scheduling pass;
* One active in the command stream at any given time;
The latter should be sufficient, by arranging to insert a INT into the stream at the end of any scheduling pass which occurs while there is not a currently outstanding INT we have sufficient backstop to allow us to refill the ring.
This assumes that there is no particular benefit to keeping the CWRITER rolling ahead of the pITS's actual processing. This is true because the ITS operates on commands in the order they appear in the queue, so there is no need to maintain a runway ahead of the ITS processing. (XXX If this is a concern perhaps the INT could be inserted at the head of the final batch of commands in a scheduling pass instead of the tail).
Xen itself should never need to issue an associated SYNC command, since the individual guests would need to issue those themselves when they care. The INT only serves to allow Xen to enqueue new commands when there is space on the ring, it has no interest itself on the actual completion.
## Locking
It may be preferable to use atomic_t types for various fields (e.g. vits_cq.creadr) in order to reduce the amount and scope of locking required.
# ITS Command Translation
This section is based on the section 5.13 of GICv3 specification (PRD03-GENC-010745 24.0). The goal is to provide insight of the cost to emulate ITS commands in Xen.
The ITS provides 12 commands in order to manage interrupt collections, devices and interrupts. Possible command parameters are device ID (ID), Event ID (vID), Collection ID (vCID), Target Address (vTA) parameters.
These parameters need to be validated and translated from Virtual to Physical.
## Parameter Validation / Translation
Each command contains parameters that needs to be validated before any usage in Xen or passing to the hardware.
### Device ID (ID)
This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.
A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
### Event ID (vID)
This is the per-device Interrupt identifier (i.e. the MSI index). It is configured by the device driver software.
It is not necessary to translate a vID, however they may need to be represented in various data structures given to the pITS.
XXX is any of this true?
### Interrupt Collection (vCID)
This parameter is used in commands which manage collections and interrupt in order to move them for one CPU to another. The ITS is only mandated to implement N + 1 collections where N is the number of processor on the platform (i.e max number of VCPUs for a given guest). Furthermore, the identifiers are always contiguous.
If we decide to implement the strict minimum (i.e N + 1), an array is enough and will allow operations in O(1).
XXX Could forgo array and go straight to vcpu_info/domain_info.
### Target Address (vTA)
This parameter is used in commands which manage collections. It is a unique identifier per processor. The format is different following the value of the GITS_TYPER.PTA bit . The value of the field is fixed by the ITS implementation and the software has to handle the 2 cases.
A solution with GITS_TYPER.PTA set to one will require some computation in order to find the VCPU associated with the redistributor address. It will be similar to get_vcpu_from_rdist in the vGICv3 emulation (xen/arch/arm/vgic-v3.c).
On another hand, setting GITS_TYPER.PTA to zero will give us control to decide the linear process number which could simply be the vcpu_id (always linear).
XXX Non-linear VCPUs e.g. via AFFR1 hierarchy?
## Command Translation
Of the existing GICv3 ITS commands, MAPC, MAPD, MAPVI/MAPI are potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALL and SYNC are global and potentially disruptive to other guests and so need consideration.
All other ITS command like MOVI, DISCARD, INV, INT, CLEAR just validate and generate physical command.
### MAPC command translation
Format: MAPC vCID, vTA
- MAPC pCID, pTA physical ITS command is generated
### MAPD Command translation
Format: MAPD device, Valid, ITT IPA, ITT Size
MAPD is sent with Valid bit set if device needs to be added and reset when device is removed.
If Valid bit is set:
- Allocate memory for its_device struct
- Validate ITT IPA & ITT size and update its_device struct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function of ITT Size?
- Allocate memory for struct vlpi_map for this device. This vlpi_map holds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Call p2m_lookup on ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command: MAPD, ITT PA, ITT Size
Here the overhead is with memory allocation for its_device and vlpi_map
XXX Suggestion was to preallocate some of those at device passthrough setup time?
If Validation bit is not set:
- Validate if the device exits by checking vITS device list
- Clear all vlpis assigned for this device
- Remove this device from vITS list
- Free memory
XXX If preallocation presumably shouldn't free here either.
### MAPVI/MAPI Command translation
Format: MAPVI device, ID, vID, vCID
- Validate if the device exits by checking vITS device list
- Validate vCID and get pCID by searching cid_map
- if vID does not have entry in vlpi_entries of this device allocate a new pID from vlpi_map of this device and update vlpi_entries with new pID
- Allocate irq descriptor and add to RB tree
- call route_irq_to_guest() for this pID
- Generate/format physical ITS command: MAPVI device ID, pID, pCID
Here the overhead is allocating physical ID, allocate memory for irq descriptor and routing interrupt.
XXX Suggested to preallocate?
### INVALL Command translation
A physical INVALL is only generated if the LPI dirty bitmap has any bits set. Otherwise it is skipped.
XXX Perhaps bitmap should just be a simple counter?
XXX bitmap is host global, a per-domain bitmap would allow us to elide INVALL unless an LPI associated with the guest making the request was dirty. Would also need some sort of "ITS INVALL" clock in order that other guests can elide their own INVALL if one has already happened. Complexity not worth it at this stage?
### SYNC Command translation
Can be omitted from the physical command stream if the previous command was also a SYNC, i.e. due to a guest sending a series of SYNC commands or one guest's batch ending with one and the nexts beggining.
XXX TBD can we do anything more? e.g. omit sync if the guest hasn't done anything of importance since the last sync?
# GICv4 Direct Interrupt Injection
GICv4 will directly mark the LPIs pending in the virtual pending table which is per-redistributor (i.e per-vCPU).
LPIs will be received by the guest the same way as an SPIs. I.e trap in IRQ mode then read ICC_IAR1_EL1 (for GICv3).
Therefore GICv4 will not require one vITS per pITS.
# Event Channels
It has been proposed that it might be nice to inject event channels as LPIs in the future. Whether or not that would involve any sort of vITS is unclear, but if it did then it would likely be a separate emulation to the vITS emulation used with a pITS and as such is not considered further here.
# Glossary
* _MSI_: Message Signalled Interrupt
* _ITS_: Interrupt Translation Service
* _GIC_: Generic Interrupt Controller
* _LPI_: Locality-specific Peripheral Interrupt
# References
"GIC Architecture Specification" PRD03-GENC-010745 24.0
Quoted 313 lines · Ian Campbell
Here follows draft C based on previous feedback.
Also at:
http://xenbits.xen.org/people/ianc/vits/draftC.{pdf,html}
I think I've captured most of the previous discussion, except where explicitly noted by XXX or in other replies, but please do point out places where I've missed something.
One area where I am pretty sure I've dropped the ball is on the completion and update of
CREADR. That conversation ended up bifurcating along the 1:N vs N:N mapping scheme lines, and I didn't manage to get the various proposals straight. Since we've now agreed on N:N hopefully we can reach a conclusion (no pun intended) on the completion aspect too (sorry that this probably means rehasing at least a subset of the previous thread).Ian.
% Xen on ARM vITS Handling
% Ian Campbell <[email protected]>
% Draft C# Changelog
## Since Draft B
* Details of command translation (thanks to Julien and Vijay)
* Added background on LPI Translation and Pending tablesd
* Added background on Collections
* Settled onN:Nscheme for vITS:pITS mapping.
* Rejigged section nesting a bit.
* Since we now thing translation should be cheap, settle on translation at scheduling time.
* LazyINVALLandSYNC## Since Draft A
* Added discussion of when/where command translation occurs.
* Contention on scheduler lock, suggestion to use SOFTIRQ.
* Handling of domain shutdown.
* More detailed discussion of multiple vs single vits pros/cons.# Introduction
ARM systems containing a GIC version 3 or later may contain one or more ITS logical blocks. An ITS is used to route Message Signalled interrupts from devices into an LPI injection on the processor.
The following summarises the ITS hardware design and serves as a set of assumptions for the vITS software design. (XXX it is entirely possible I've horribly misunderstood how this stuff fits together). For full details of the ITS see the "GIC Architecture Specification".
## Device Identifiers
Each device using the ITS is associated with a unique identifier.
The device IDs are typically described via system firmware, e.g. the ACPI IORT table or via device tree.
The number of device ids is variable and can be discovered via
GITS_TYPER.Devbits. This field allows an ITS to have up to 2^32 device.## Interrupt Collections
Each interrupt is a member of an Interrupt Collection. This allows software to manage large numbers of physical interrupts with a small number of commands rather than issuing one command per interrupt.
On a system with N processors, the ITS must provide at least N+1 collections.
## Target Addresses
The Target Address correspond to a specific GIC re-distributor. The format of this field depends on the value of the
GITS_TYPER.PTAbit:* 1: the base address of the re-distributor target is used
* 0: a unique processor number is used. The mapping between the processor affinity value (MPIDR) and the processor number is discoverable viaGICR_TYPER.ProcessorNumber.## ITS Translation Table
Message signalled interrupts are translated into an LPI via an ITS translation table which must be configured for each device which can generate an MSI.
The ITS translation table maps the device id of the originating devic into an Interrupt Collection and then into a target address.
## ITS Configuration
The ITS is configured and managed, including establishing and configuring Translation Table for each device, via an in memory ring shared between the CPU and the ITS controller. The ring is managed via the
GITS_CBASERregister and indexed byGITS_CWRITERandGITS_CREADRregisters.A processor adds commands to the shared ring and then updates
GITS_CWRITERto make them visible to the ITS controller.The ITS controller processes commands from the ring and then updates
GITS_CREADRto indicate the the processor that the command has been processed.Commands are processed sequentially.
Commands sent on the ring include operational commands:
* Routing interrupts to processors;
* Generating interrupts;
* Clearing the pending state of interrupts;
* Synchronising the command queueand maintenance commands:
* Map device/collection/processor;
* Map virtual interrupt;
* Clean interrupts;
* Discard interrupts;The field
GITS_CBASER.Sizeencodes the number of 4KB pages minus 0 consisting of the command queue. This field is 8 bits which means the maximum size is 2^8 * 4KB = 1MB. Given that each command is 32 bytes, there is a maximum of 32768 commands in the queue.The ITS provides no specific completion notification mechanism. Completion is monitored by a combination of a
SYNCcommand and either pollingGITS_CREADRor notification via an interrupt generated via theINTcommand.Note that the interrupt generation via
INTrequires an originating device ID to be supplied (which is then translated via the ITS into an LPI). No specific device ID is defined for this purpose and so the OS software is expected to fabricate one.Possible ways of inventing such a device ID are:
* Enumerate all device ids in the system and pick another one;
* Use a PCI BDF associated with a non-existent device function (such as an unused one relating to the PCI root-bridge) and translate that (via firmware tables) into a suitable device id;
* ???## LPI Configuration Table
Each LPI has an associated configuration byte in the LPI Configuration Table (managed via the GIC Redistributor and placed at
GICR_PROPBASERorGICR_VPROPBASER). This byte configures:* The LPI's priority;
* Whether the LPI is enabled or disabled.Software updates the Configuration Table directly but must then issue an invalidate command (per-device
INVITS command, globalINVALLITS command or writeGICR_INVLPIR) for the affect to be guaranteed to become visible (possibly requiring an ITSSYNCcommand to ensure completion of theINVorINVALL). Note that it is valid for an implementaiton to reread the configuration table at any time (IOW it is _not_ guarenteed that a change to the LPI Configuration Table won't be visible until an invalidate is issued).## LPI Pending Table
Each LPI also has an associated bit in the LPI Pending Table (managed by the GIC redistributor). This bit signals whether the LPI is pending or not.
# vITS
A guest domain which is allowed to use ITS functionality (i.e. has been assigned pass-through devices which can generate MSIs) will be presented with a virtualised ITS.
Accesses to the vITS registers will trap to Xen and be emulated and a virtualised Command Queue will be provided.
Commands entered onto the virtual Command Queue will be translated into physical commands, as described later in this document.
XXX there are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are not currently considered here. XXX Should they be/do they need to be?
# Requirements
Emulation should not block in the hypervisor for extended periods. In particular Xen should not busy wait on the physical ITS. Doing so blocks the physical CPU from doing anything else (such as scheduling other VCPUS)
There may be multiple guests which have a vITS, all targeting the same underlying pITS. A single guest VCPU should not be able to monopolise the pITS via its vITS and all guests should be able to make forward progress.
# vITS to pITS mapping
A physical system may have multiple physical ITSs.
We assume that a given device is only associated with one pITS.
A guest which is given access to multiple devices associated with multiple pITSs will need to be given virtualised access to all associated pITSs.
There are several possible models for achieving this:
*
1:N: One virtual ITS tired to multiple physical ITS.
*N:N: One virtual ITS per physical ITS.
*M:N: Multiple virtual ITS tied to a differing number of physical ITSs.This design assumes an
N:Nmodel, which is thought to be simpler on the Xen side since it avoids questions of how to fairly schedule commands in the1:Nmodel while avoiding starvation as well as simplifying the virtualisation of global commands such asINVALLorSYNC.The
N:Nmodel is also a better fit for I/O NUMA systems.Since the choice of model is internal to the hypervisor/tools and is communicated to the guest via firmware tables we are not tied to this model as an ABI if we decide to change.
New toolstack domctls or extension to existing domctls will likely be required to allow the toolstack to determine the number of vITS which will be required for the guest and to determine the mapping for passed-through devices.
# LPI Configuration Table Virtualistion
A guest's write accesses to its LPI Configuration Table (which is just an area of guest RAM which the guest has nominated) will be trapped to the hypervisor, using stage 2 MMU permissions, in order for changes to be propagated into the physical LPI Configuration Table.
A host wide LPI dirty bit map, with 1 bit per LPI, will be maintained which indicates whether an update to the physical LPI Configuration Table has been flushed (via an invalidate command). The corresponding bit will be set whenever a guest changes the configuration of an LPI.
This dirty bit map will be used during the handling of relevant ITS Commands (
INV,INVALLetc).Note that no invalidate is required during the handling of an LPI Configuration Table trap.
# Command Queue Virtualisation
The command queue of each vITS is represented by a data structure:
struct
vits_cq{
list_headschedule_list; /* Queued onto pits.schedule_list */
uint32_tcreadr; /* Virtual creadr */
uint32_tcwriter; /* Virtual cwriter */
uint32_tprogress; /* Index of last command queued to pits */
[ Reference to command queue memory ]
};Each pITS has an associated data structure:
struct pits { list_head schedule_list; /* Contains list of vitq_cq.schedule_lists */ uint32_t last_creadr; };On write to the virtual
CWRITERthe cwriter field is updated and if that results in there being new outstanding requests then thevits_cqis enqueued onto pITS'schedule_list(unless it is already there).On read from the virtual
CREADRiff thevits_cqis such that commands are outstanding then a scheduling pass is attempted (in order to updatevits_cq.creadr). The current value ofvitq_cq.creadris then returned.## Command translation
In order to virtualise the Command Queue each command must be translated (this is described in the GIC spec).
Translation of certain commands is potentially expensive, however we will attempt to arrange things (data structures etc) such that the overhead a translation time is minimised (see later).
Translation can be done in two places:
* During scheduling.
* On write toCWRITER, into a pervits_cqqueue which the scheduler then propagates to the pits.Doing the translate during scheduling means that potentially expensive operations may be accounted to
current, who may have nothing to do with those operations (this is true whether it is IRQ context or SOFTIRQ context).Doing the translate during
CWRITERemulation accounts it to the right place, but introduces a potentially long synchronous operation which ties down a VCPU. Introducing batching here means we have essentially the same issue wrt when to replenish the translated queue as doing translate during scheduling.Translate during
CWRITERalso has memory overheads. Unclear if they are at a problematic scale or not.Since we have arranged for translation overheads to be minimised it seems that translation during scheduling should be tollerable.
Quoted 6 lines
## pITS Scheduling
A pITS scheduling pass is attempted:
* On write to any virtual
CWRITERiff that write results in there being new outstanding requests for that vits;
You mean, scheduling pass (softirq trigger) is triggered iff there is no
ongoing requests from that vits?
Quoted 11 lines
* On read from a virtual
CREADRiff there are commands outstanding on that vits;
* On receipt of an interrupt notification arising from Xen's own use ofINT; (see discussion under Completion)
* On any interrupt injection arising from a guests use of theINTcommand; (XXX perhaps, see discussion under Completion)This may result in lots of contention on the scheduler locking. Therefore we consider that in each case all which happens is triggering of a softirq which will be processed on return to guest, and just once even for multiple events.
Is it required to have all the cases to trigger scheduling pass? Just on CWRITER if no ongoing request and on Xen's own completion INT is not sufficient?
Quoted 98 lines
Such deferral could be considered OK (XXX ???) for the
CREADRcase because at worst the value read will be one cycle out of date. A guest which receives anINTnotification might reasonably expect a subsequent read ofCREADRto reflect that. However that should be covered by the softint processing which would occur on entry to the guest to inject theINT.Each scheduling pass will:
* Read the physical
CREADR;
* For each command betweenpits.last_creadrand the newCREADRvalue process completion of that command and update the correspondingvits_cq.creadr.
* Attempt to refill the pITS Command Queue (see below).## Domain Shutdown
We can't free a
vits_cqwhile has things on the physical control queue, and we cannot cancel things which are on the control queue.So we must wait.
Obviously don't enqueue anything new onto the pits if
d->is_dying.
domain_relinquish_resources()waits (somehow, with suitable continuations etc) for anything which thevits_cqhas outstanding to be completed so that the datastructures can be cleared.## Filling the pITS Command Queue.
Various algorithms could be used here. For now a simple proposal is to traverse the
pits.schedule_liststarting from where the last refill finished (i.e not from the top of the list each time).In order to simplify bookkeeping and to bound the amount of time spent on a single scheduling pass each
vitq_cqwill only have a single batch of commands enqueued with the PITs at a time.If a
vits_cqhas no pending commands then it is removed from the list.If a
vits_cqalready has commands enqueued with the pITS Command Queue then it is skipped.If a
vits_cqhas some pending commands thenmin(pits-free-slots, vits-outstanding, VITS_BATCH_SIZE)will be taken from the vITS command queue, translated and placed onto the pITS queue.vits_cq.progresswill be updated to reflect this.Each
vits_cqis handled in turn in this way until the pITS Command Queue is full, there are no more outstanding commands or each activevits_cqhas commands enqueued with the pITS.There will likely need to be a data structure which shadows the pITS Command Queue slots with references to the
vits_cqwhich has a command currently occupying that slot and corresponding the index into the virtual command queue, for use when completing a command.
VITS_BATCH_SIZEshould be small, TBD say 4 or 8.## Completion
It is expected that commands will normally be completed (resulting in an update of the corresponding
vits_cq.creadr) via guest read fromCREADR. This will trigger a scheduling pass which will ensure thevits_cq.creadrvalue is up to date before it is returned.A guest which does completion via the use of
INTcannot observeCREADRwithout reading it, so updating on read fromCREADRsuffices from the point of view of the guests observation of the state. (Of course we will inject the interrupt at the designated point and the guest may well then readCREADR)However in order to keep the pITS Command Queue moving along we need to consider what happens if there are no
INTbased events nor reads fromCREADRto drive completion and therefore refilling of the Queue with other outstanding commands.A guest which enqueues some commands and then never checks for completion cannot itself block things because any other guest which reads
CREADRwill drive completion. However if _no_ guest reads fromCREADRthen completion will not occur and this must be dealt with.Even if we include completion on
INT-base interrupt injection then it is possible that the pITS queue may not contain any such interrupts, either because no guest is using them or because the batching means that none of them are enqueued on the active ring at the moment.So we need a fallback to ensure that queue keeps moving. There are several options:
* A periodic timer in Xen which runs whenever there are outstanding commands in the pITS. This is simple but pretty sucky.
* Xen injects its ownINTcommands into the pITS ring. This requires figuring out a device ID to use.
Quoted 7 lines
The second option is likely to be preferable if the issue of selecting a device ID can be addressed.
A secondary question is when these
INTcommands should be inserted into the command stream:* After each batch taken from a single
vits_cq;
Is this not enough? because Scheduling pass just sends a one batch of
command with Xen's INT command
Quoted 68 lines
* After each scheduling pass;
* One active in the command stream at any given time;The latter should be sufficient, by arranging to insert a
INTinto the stream at the end of any scheduling pass which occurs while there is not a currently outstandingINTwe have sufficient backstop to allow us to refill the ring.This assumes that there is no particular benefit to keeping the
CWRITERrolling ahead of the pITS's actual processing. This is true because the ITS operates on commands in the order they appear in the queue, so there is no need to maintain a runway ahead of the ITS processing. (XXX If this is a concern perhaps the INT could be inserted at the head of the final batch of commands in a scheduling pass instead of the tail).Xen itself should never need to issue an associated
SYNCcommand, since the individual guests would need to issue those themselves when they care. TheINTonly serves to allow Xen to enqueue new commands when there is space on the ring, it has no interest itself on the actual completion.## Locking
It may be preferable to use
atomic_ttypes for various fields (e.g.vits_cq.creadr) in order to reduce the amount and scope of locking required.# ITS Command Translation
This section is based on the section 5.13 of GICv3 specification (PRD03-GENC-010745 24.0). The goal is to provide insight of the cost to emulate ITS commands in Xen.
The ITS provides 12 commands in order to manage interrupt collections, devices and interrupts. Possible command parameters are device ID (
ID), Event ID (vID), Collection ID (vCID), Target Address (vTA) parameters.These parameters need to be validated and translated from Virtual to Physical.
## Parameter Validation / Translation
Each command contains parameters that needs to be validated before any usage in Xen or passing to the hardware.
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.
Quoted 3 lines
A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
When PHYSDEVOP_pci_device_add is called, memory for its_device structure and other needed structure for this device is allocated added to RB-tree with all necessary information
Quoted 51 lines
### Event ID (
vID)This is the per-device Interrupt identifier (i.e. the MSI index). It is configured by the device driver software.
It is not necessary to translate a
vID, however they may need to be represented in various data structures given to the pITS.XXX is any of this true?
### Interrupt Collection (
vCID)This parameter is used in commands which manage collections and interrupt in order to move them for one CPU to another. The ITS is only mandated to implement N + 1 collections where N is the number of processor on the platform (i.e max number of VCPUs for a given guest). Furthermore, the identifiers are always contiguous.
If we decide to implement the strict minimum (i.e N + 1), an array is enough and will allow operations in O(1).
XXX Could forgo array and go straight to vcpu_info/domain_info.
### Target Address (
vTA)This parameter is used in commands which manage collections. It is a unique identifier per processor. The format is different following the value of the
GITS_TYPER.PTAbit . The value of the field is fixed by the ITS implementation and the software has to handle the 2 cases.A solution with
GITS_TYPER.PTAset to one will require some computation in order to find the VCPU associated with the redistributor address. It will be similar toget_vcpu_from_rdistin the vGICv3 emulation (xen/arch/arm/vgic-v3.c).On another hand, setting GITS_TYPER.PTA to zero will give us control to decide the linear process number which could simply be the
vcpu_id(always linear).XXX Non-linear VCPUs e.g. via AFFR1 hierarchy?
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.
Quoted 7 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA
- The GITS_TYPER.PAtype is emulated as 0. Hence vTA is always represents vcpu number. Hence vTA is validated against physical Collection
IDs by querying
ITS driver and corresponding Physical Collection ID is retrieved.
- Each vITS will have cid_map (struct cid_mapping) which holds mapping of Virtual Collection ID(vCID), Virtual Target address(vTA) and Physical Collection ID (pCID).
If vCID entry already exists in cid_map, then that particular
mapping is updated with
the new pCID and vTA else new entry is made in cid_map
- MAPC pCID, pTA physical ITS command is generated
Here there is no overhead, the cid_map entries are preallocated
with size of nr_cpus
in the platform.
Quoted 23 lines
-
MAPC pCID, pTAphysical ITS command is generated###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT Size
Quoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
If Validation bit is set:
- Query its_device tree and get its_device structure for this device.
- (XXX: If pci device is hidden from dom0, does this device is added with PHYSDEVOP_pci_device_add hypercall?)
- If device does not exists return
- If device exists in RB-tree then
- Validate ITT IPA & ITT size and update its_device struct
- Check if device is already assigned to the domain,
if not then
- Find number of vectors(nrvecs) for this device.
- Allocate nrvecs number of LPI
- Fetch vlpi_map for this device (preallocated at the
time of adding
this device to Xen). This vlpi_map holds mapping of
Virtual LPI to
Physical LPI and ID.
- Call p2m_lookup on ITT IPA addr and get physical ITT address
- Assign this device to this domain and mark as enabled
- If this device already exists with the domain (Domain is
remapping the device)
- Validate ITT IPA & ITT size and update its_device struct
- Call p2m_lookup on ITT IPA addr and get physical ITT address
- Disable all the LPIs of this device by searching
through vlpi_map and LPI
configuration table
- Generate/format physical ITS command: MAPD, ITT PA, ITT Size
Quoted 10 lines
If Validation bit is not set:
- Validate if the device exits by checking vITS device list
- Clear allvlpisassigned for this device
- Remove this device from vITS list
- Free memoryXXX If preallocation presumably shouldn't free here either.
If Validation bit is not set:
- Validate if the device exits by checking RB-tree and is assigned
to this domain
- Disable all the LPIs associated with this device and release irq
- Clear all vlpis mapping for this device
- Remove this device from the domain
Quoted 7 lines
###
MAPVI/MAPICommand translationFormat:
MAPVI device, ID, vID, vCID- Validate if the device exits by checking vITS device list
- Validate vCID and get pCID by searchingcid_map
Quoted 7 lines
- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCID
- Validate if the device exists by checking vITS device RB-tree.
- Validate vCID and get pCID by searching cid_map
- if vID does not have entry in vlpi_entries of this device
- Allot pID from vlpi_map of this device and updatevlpi_entries with new pID.
- Allocate irq descriptor and add to RB tree
- call route_irq_to_guest() for this pID
If exists,
- If vCID is different ( remapping interrupts to differnt collection ),
- Disable LPI
- Update the vlpi_map
(XXX: Enable LPI on guest request?)
- Generate/format physical ITS command: MAPVI device ID, pID, pCID
Quoted 58 lines
Here the overhead is allocating physical ID, allocate memory for irq descriptor and routing interrupt.
XXX Suggested to preallocate?
###
INVALLCommand translationA physical
INVALLis only generated if the LPI dirty bitmap has any bits set. Otherwise it is skipped.XXX Perhaps bitmap should just be a simple counter?
XXX bitmap is host global, a per-domain bitmap would allow us to elide
INVALLunless an LPI associated with the guest making the request was dirty. Would also need some sort of "ITS INVALL" clock in order that other guests can elide their ownINVALLif one has already happened. Complexity not worth it at this stage?###
SYNCCommand translationCan be omitted from the physical command stream if the previous command was also a
SYNC, i.e. due to a guest sending a series ofSYNCcommands or one guest's batch ending with one and the nexts beggining.XXX TBD can we do anything more? e.g. omit sync if the guest hasn't done anything of importance since the last sync?
# GICv4 Direct Interrupt Injection
GICv4 will directly mark the LPIs pending in the virtual pending table which is per-redistributor (i.e per-vCPU).
LPIs will be received by the guest the same way as an SPIs. I.e trap in IRQ mode then read
ICC_IAR1_EL1(for GICv3).Therefore GICv4 will not require one vITS per pITS.
# Event Channels
It has been proposed that it might be nice to inject event channels as LPIs in the future. Whether or not that would involve any sort of vITS is unclear, but if it did then it would likely be a separate emulation to the vITS emulation used with a pITS and as such is not considered further here.
# Glossary
* _MSI_: Message Signalled Interrupt
* _ITS_: Interrupt Translation Service
* _GIC_: Generic Interrupt Controller
* _LPI_: Locality-specific Peripheral Interrupt# References
"GIC Architecture Specification" PRD03-GENC-010745 24.0
Hi Vijay,
Quoted 14 lines · Vijay Kilari
Quoted 14 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translation
Quoted 7 lines
Quoted 2 lines
Format:
MAPC vCID, vTA- The GITS_TYPER.PAtype is emulated as 0. Hence vTA is always represents vcpu number. Hence vTA is validated against physical Collection
IDs by querying
ITS driver and corresponding Physical Collection ID is retrieved.
- Each vITS will havecid_map(structcid_mapping) which holds mapping of
Why do you speak about each vITS? The emulation is only related to one vITS and not shared...
Quoted 5 lines
Virtual Collection ID(vCID), Virtual Target address(vTA) and Physical Collection ID (pCID).
If vCID entry already exists incid_map, then that particular
mapping is updated with
the new pCID and vTA else new entry is made incid_map
When you move a collection, you also have to make sure that all the interrupts associated to it will be delivered to the new target.
I'm not sure what you are suggesting for that...
Quoted 1 line
- MAPC pCID, pTA physical ITS command is generated
We should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot and the guest should not be able to move the physical collection (they are shared between all the guests and Xen).
Quoted 4 lines
Here there is no overhead, the
cid_mapentries are preallocated
with size ofnr_cpus
in the platform.
As said the number of collection should be at least nr_cpus + 1.
Quoted 29 lines
Quoted 24 lines
-
MAPC pCID, pTAphysical ITS command is generated###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT SizeQuoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
Quoted 7 lines
If Validation bit is set:
- Queryits_devicetree and getits_devicestructure for this device.
- (XXX: If pci device is hidden from dom0, does this device is added withPHYSDEVOP_pci_device_addhypercall?)
- If device does not exists return
- If device exists in RB-tree then
- Validate ITT IPA & ITT size and updateits_devicestruct
To validate the ITT size you need to know the number of interrupt ID.
Quoted 10 lines
- Check if device is already assigned to the domain,
if not then
- Find number of vectors(nrvecs) for this device.
- Allocate nrvecs number of LPI
- Fetchvlpi_mapfor this device (preallocated at the
time of adding
this device to Xen). Thisvlpi_mapholds mapping of
Virtual LPI to
Physical LPI and ID.
- Callp2m_lookupon ITT IPA addr and get physical ITT address
Quoted 8 lines
- Assign this device to this domain and mark as enabled
- If this device already exists with the domain (Domain is
remapping the device)
- Validate ITT IPA & ITT size and updateits_devicestruct
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Disable all the LPIs of this device by searching
throughvlpi_mapand LPI
configuration table
Disabling all the LPIs associated to a device can be time consuming because you have to unroute them and make sure that the physical ITS effectively disabled it before sending the MAPD command.
Given that the software would be buggy if it send a MAPD command without releasing all the associated interrupt we could ignore the command if any interrupt is still enabled.
Quoted 11 lines
- Generate/format physical ITS command: MAPD, ITT PA, ITT Size
Quoted 8 lines
If Validation bit is not set:
- Validate if the device exits by checking vITS device list
- Clear allvlpisassigned for this device
- Remove this device from vITS list
- Free memory
Quoted 5 lines
Quoted 2 lines
XXX If preallocation presumably shouldn't free here either.
If Validation bit is not set:
- Validate if the device exits by checking RB-tree and is assigned
exists
Quoted 2 lines
to this domain
- Disable all the LPIs associated with this device and release irq
That could be very expensive... We should deny the command if the associated interrupts are not disabled.
Quoted 18 lines
- Clear all vlpis mapping for this device
- Remove this device from the domainQuoted 7 lines
###
MAPVI/MAPICommand translationFormat:
MAPVI device, ID, vID, vCID- Validate if the device exits by checking vITS device list
- Validate vCID and get pCID by searchingcid_mapQuoted 7 lines
- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCID
Quoted 10 lines
- Validate if the device exists by checking vITS device RB-tree.
- Validate vCID and get pCID by searchingcid_map
- if vID does not have entry invlpi_entriesof this device
- Allot pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID.
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
If exists,
- If vCID is different ( remapping interrupts to differnt collection ),
- Disable LPI
You have to ensure the the LPI is disabled with an INV/SYNC.
Although as suggested on the previous commands, we may want to deny the command if the interrupt is not disabled.
Quoted 2 lines
- Update the
vlpi_map
(XXX: Enable LPI on guest request?)
Read the spec...
Regards,
Signature · 1 line
Julien Grall
Quoted 19 lines · Julien Grall
Hi Vijay,
Quoted 16 lines · Vijay Kilari
Quoted 16 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA
Quoted 8 lines
Quoted 5 lines
- The GITS_TYPER.PAtype is emulated as 0. Hence vTA is always represents vcpu number. Hence vTA is validated against physical Collection
IDs by querying
ITS driver and corresponding Physical Collection ID is retrieved.
- Each vITS will havecid_map(structcid_mapping) which holds mapping ofWhy do you speak about each vITS? The emulation is only related to one vITS and not shared...
And each vITS will have a cid_map, which is used. This seems like a reasonable way to express this concept in the context.
Perhaps there is a need to include discussion of some of the secondary data structures alongside the defintion cits_cq. In which case we could talk about "its associated cid_map" and things.
Quoted 10 lines
Quoted 5 lines
Virtual Collection ID(vCID), Virtual Target address(vTA) and Physical Collection ID (pCID).
If vCID entry already exists incid_map, then that particular
mapping is updated with
the new pCID and vTA else new entry is made incid_mapWhen you move a collection, you also have to make sure that all the interrupts associated to it will be delivered to the new target.
I'm not sure what you are suggesting for that...
This is going to be rather painful I fear.
Quoted 6 lines
Quoted 1 line
- MAPC pCID, pTA physical ITS command is generated
We should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot and the guest should not be able to move the physical collection (they are shared between all the guests and Xen).
This needs discussion in the background section, to describe the physical setup which the virtual stuff can make assumption of.
Quoted 5 lines
Quoted 3 lines
Here there is no overhead, the
cid_mapentries are preallocated
with size ofnr_cpus
in the platform.As said the number of collection should be at least
nr_cpus+ 1.
FWIW I read this as "with size appropriate for nr_cpus", which leaves the +1 as implicit. I added the +1 nevertheless.
Quoted 36 lines
Quoted 28 lines
Quoted 23 lines
-
MAPC pCID, pTAphysical ITS command is generated###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT SizeQuoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
Quoted 7 lines
If Validation bit is set:
- Queryits_devicetree and getits_devicestructure for this device.
- (XXX: If pci device is hidden from dom0, does this device is added withPHYSDEVOP_pci_device_addhypercall?)
- If device does not exists return
- If device exists in RB-tree then
- Validate ITT IPA & ITT size and updateits_devicestruct
Quoted 1 line
To validate the ITT size you need to know the number of interrupt ID.
Please could you get into the habit of making concrete suggestions for changes to the text. I've no idea what change I should make based on this observation. If not concrete suggestions please try and make the implications of what you are saying clear.
Quoted 20 lines
Quoted 11 lines
- Check if device is already assigned to the domain,
if not then
- Find number of vectors(nrvecs) for this device.
- Allocate nrvecs number of LPI
- Fetchvlpi_mapfor this device (preallocated at the
time of adding
this device to Xen). Thisvlpi_mapholds mapping of
Virtual LPI to
Physical LPI and ID.
- Callp2m_lookupon ITT IPA addr and get physical ITT addressQuoted 8 lines
- Assign this device to this domain and mark as enabled
- If this device already exists with the domain (Domain is
remapping the device)
- Validate ITT IPA & ITT size and updateits_devicestruct
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Disable all the LPIs of this device by searching
throughvlpi_mapand LPI
configuration table
Quoted 7 lines
Disabling all the LPIs associated to a device can be time consuming because you have to unroute them and make sure that the physical ITS effectively disabled it before sending the MAPD command.
Given that the software would be buggy if it send a MAPD command without releasing all the associated interrupt we could ignore the command if any interrupt is still enabled.
Releasing how? Did you mean disable?
Quoted 29 lines
Quoted 18 lines
- Clear all vlpis mapping for this device
- Remove this device from the domainQuoted 7 lines
###
MAPVI/MAPICommand translationFormat:
MAPVI device, ID, vID, vCID- Validate if the device exits by checking vITS device list
- Validate vCID and get pCID by searchingcid_mapQuoted 7 lines
- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCIDQuoted 10 lines
- Validate if the device exists by checking vITS device RB-tree.
- Validate vCID and get pCID by searchingcid_map
- if vID does not have entry invlpi_entriesof this device
- Allot pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID.
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
If exists,
- If vCID is different ( remapping interrupts to differnt collection ),
- Disable LPI
Quoted 1 line
You have to ensure the the LPI is disabled with an INV/SYNC.
Can we not rely on the subsequent INV/SYNC from the guest relating to the MAPI here?
Quoted 7 lines
Although as suggested on the previous commands, we may want to deny the command if the interrupt is not disabled.
Quoted 2 lines
- Update the
vlpi_map
(XXX: Enable LPI on guest request?)Read the spec...
If you know the answer then please share it rather than making people guess what you are talking about.
Ian.
Hi Ian,
Quoted 26 lines · Ian Campbell
Quoted 25 lines · Julien Grall
Hi Vijay,
Quoted 21 lines · Vijay Kilari
Quoted 9 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.Quoted 7 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA- The GITS_TYPER.PAtype is emulated as 0. Hence vTA is always represents vcpu number. Hence vTA is validated against physical Collection
IDs by querying
ITS driver and corresponding Physical Collection ID is retrieved.
- Each vITS will havecid_map(structcid_mapping) which holds mapping of
Quoted 5 lines
Quoted 2 lines
Why do you speak about each vITS? The emulation is only related to one vITS and not shared...
And each vITS will have a
cid_map, which is used. This seems like a reasonable way to express this concept in the context.
This is rather strange when everything in the command emulation is per-vits.
Quoted 19 lines
Perhaps there is a need to include discussion of some of the secondary data structures alongside the defintion
cits_cq. In which case we could talk about "its associatedcid_map" and things.Quoted 10 lines
Quoted 5 lines
Virtual Collection ID(vCID), Virtual Target address(vTA) and Physical Collection ID (pCID).
If vCID entry already exists incid_map, then that particular
mapping is updated with
the new pCID and vTA else new entry is made incid_mapWhen you move a collection, you also have to make sure that all the interrupts associated to it will be delivered to the new target.
I'm not sure what you are suggesting for that...
This is going to be rather painful I fear.
Quoted 2 lines
Quoted 1 line
- MAPC pCID, pTA physical ITS command is generated
Quoted 7 lines
Quoted 4 lines
We should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot and the guest should not be able to move the physical collection (they are shared between all the guests and Xen).
This needs discussion in the background section, to describe the physical setup which the virtual stuff can make assumption of.
I don't think this is a background section. The physical number of collection is limited (the mandatory number of collections is nr_cpus + 1). Those collection will likely be shared between Xen and the different guests.
If we let the guest moving the physical collection we will also move all the interrupts which is wrong.
Quoted 9 lines
Quoted 6 lines
Quoted 4 lines
Here there is no overhead, the
cid_mapentries are preallocated
with size ofnr_cpus
in the platform.As said the number of collection should be at least
nr_cpus+ 1.FWIW I read this as "with size appropriate for
nr_cpus", which leaves the +1 as implicit. I added the +1 nevertheless.
I wanted to make clear. His implementation was only considering nr_cpus collections.
Quoted 37 lines
Quoted 37 lines
Quoted 36 lines
Quoted 24 lines
-
MAPC pCID, pTAphysical ITS command is generated###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT SizeQuoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
If Validation bit is set:
- Queryits_devicetree and getits_devicestructure for this device.
- (XXX: If pci device is hidden from dom0, does this device is added withPHYSDEVOP_pci_device_addhypercall?)
- If device does not exists return
- If device exists in RB-tree then
- Validate ITT IPA & ITT size and updateits_devicestruct
Quoted 6 lines
Quoted 1 line
To validate the ITT size you need to know the number of interrupt ID.
Please could you get into the habit of making concrete suggestions for changes to the text. I've no idea what change I should make based on this observation. If not concrete suggestions please try and make the implications of what you are saying clear.
The size of the ITT is based on the number of Interrupt supported by the device.
The only way to validate the size getting the number of Interrupt before. i.e
- Find the number of MSI for this device
- Compute the theorical size of the ITT
- Validate the ITT IPA and the ITT size
- Update the its_device struct
Note: this is based on this conversation and doesn't take into account the other threads.
Quoted 26 lines
Quoted 26 lines
Quoted 13 lines
- Check if device is already assigned to the domain,
if not then
- Find number of vectors(nrvecs) for this device.
- Allocate nrvecs number of LPI
- Fetchvlpi_mapfor this device (preallocated at the
time of adding
this device to Xen). Thisvlpi_mapholds mapping of
Virtual LPI to
Physical LPI and ID.
- Callp2m_lookupon ITT IPA addr and get physical ITT addressQuoted 8 lines
- Assign this device to this domain and mark as enabled
- If this device already exists with the domain (Domain is
remapping the device)
- Validate ITT IPA & ITT size and updateits_devicestruct
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Disable all the LPIs of this device by searching
throughvlpi_mapand LPI
configuration tableDisabling all the LPIs associated to a device can be time consuming because you have to unroute them and make sure that the physical ITS effectively disabled it before sending the MAPD command.
Quoted 5 lines
Quoted 3 lines
Given that the software would be buggy if it send a MAPD command without releasing all the associated interrupt we could ignore the command if any interrupt is still enabled.
Releasing how? Did you mean disable?
I think disable is enough (see 4.9.18).
Quoted 30 lines
Quoted 30 lines
Quoted 29 lines
- Clear all vlpis mapping for this device
- Remove this device from the domainQuoted 7 lines
###
MAPVI/MAPICommand translationFormat:
MAPVI device, ID, vID, vCID- Validate if the device exits by checking vITS device list
- Validate vCID and get pCID by searchingcid_mapQuoted 7 lines
- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCID- Validate if the device exists by checking vITS device RB-tree.
- Validate vCID and get pCID by searchingcid_map
- if vID does not have entry invlpi_entriesof this device
- Allot pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID.
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
If exists,
- If vCID is different ( remapping interrupts to differnt collection ),
- Disable LPI
Quoted 4 lines
Quoted 1 line
You have to ensure the the LPI is disabled with an INV/SYNC.
Can we not rely on the subsequent INV/SYNC from the guest relating to the MAPI here?
I think you meant MAPVI here.
It's not mandatory that MAPVI is followed by an INV. INV is only used when the software modified the LPI configuration table.
Furthermore, it's not clear what would be the behavior of the ITS if the interrupt is not correctly disabled (i.e not having an INV/SYNC before MAPI).
Although, I think more about it and Xen should not disable/enable any IRQ without the explicit request of the guest. Based on 4.9.17, I think we can ignore the command if the IRQ has not been disabled (i.e LPI disabled in the LPI conf table + INV/INVALL sent).
Quoted 11 lines
Quoted 8 lines
Although as suggested on the previous commands, we may want to deny the command if the interrupt is not disabled.
Quoted 2 lines
- Update the
vlpi_map
(XXX: Enable LPI on guest request?)Read the spec...
If you know the answer then please share it rather than making people guess what you are talking about.
The Spec is pretty clear on it (see 4.9.17). The guest is managing the interrupt itself via the LPI configuration table, we should not try to do more than the guest ask.
The question to enable/disable the IRQ will depend on the virtual LPI configuration table and if we already replicated the value to the physical one.
Although as we don't have any mapping vLPI -> pLPI at this time, it likely means that we have to check the virtual LPI configuration table, replicate the value in the physical table and then send an INV/SYNC (if the value has been toggled) to ensure the completion.
This is because it would be valid, even if it's pointless, to enable an LPI before mapping a (DevID, ID).
Regards,
Signature · 4 lines
Julien Grall -- Julien Grall
Quoted 29 lines · Julien Grall
Hi Ian,
Quoted 26 lines · Ian Campbell
Quoted 25 lines · Julien Grall
Hi Vijay,
Quoted 21 lines · Vijay Kilari
Quoted 9 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.Quoted 7 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA- The GITS_TYPER.PAtype is emulated as 0. Hence vTA is always represents vcpu number. Hence vTA is validated against physical Collection
IDs by querying
ITS driver and corresponding Physical Collection ID is retrieved.
- Each vITS will havecid_map(structcid_mapping) which holds mapping of
Quoted 7 lines
Quoted 5 lines
Quoted 2 lines
Why do you speak about each vITS? The emulation is only related to one vITS and not shared...
And each vITS will have a
cid_map, which is used. This seems like a reasonable way to express this concept in the context.This is rather strange when everything in the command emulation is per-vits.
I'm afraid you are going to have to say more explicitly what you find strange here.
Quoted 24 lines
Quoted 24 lines
Perhaps there is a need to include discussion of some of the secondary data structures alongside the defintion
cits_cq. In which case we could talk about "its associatedcid_map" and things.Quoted 10 lines
Quoted 5 lines
Virtual Collection ID(vCID), Virtual Target address(vTA) and Physical Collection ID (pCID).
If vCID entry already exists incid_map, then that particular
mapping is updated with
the new pCID and vTA else new entry is made incid_mapWhen you move a collection, you also have to make sure that all the interrupts associated to it will be delivered to the new target.
I'm not sure what you are suggesting for that...
This is going to be rather painful I fear.
Quoted 6 lines
Quoted 1 line
- MAPC pCID, pTA physical ITS command is generated
We should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot and the guest should not be able to move the physical collection (they are shared between all the guests and Xen).
Quoted 7 lines
Quoted 2 lines
This needs discussion in the background section, to describe the physical setup which the virtual stuff can make assumption of.
I don't think this is a background section. The physical number of collection is limited (the mandatory number of collections is
nr_cpus+ 1). Those collection will likely be shared between Xen and the different guests.
Right, and this needs to be explained in the document as an assumption upon which other things can draw, so that the document is (so far as possible) a coherent whole...
Quoted 2 lines
If we let the guest moving the physical collection we will also move all the interrupts which is wrong.
... and therefore things like this would become apparent.
Quoted 43 lines
Quoted 36 lines
Quoted 36 lines
Quoted 35 lines
Quoted 23 lines
-
MAPC pCID, pTAphysical ITS command is generated###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT SizeQuoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
If Validation bit is set:
- Queryits_devicetree and getits_devicestructure for this device.
- (XXX: If pci device is hidden from dom0, does this device is added withPHYSDEVOP_pci_device_addhypercall?)
- If device does not exists return
- If device exists in RB-tree then
- Validate ITT IPA & ITT size and updateits_devicestructQuoted 6 lines
Quoted 1 line
To validate the ITT size you need to know the number of interrupt ID.
Please could you get into the habit of making concrete suggestions for changes to the text. I've no idea what change I should make based on this observation. If not concrete suggestions please try and make the implications of what you are saying clear.
Quoted 7 lines
The size of the ITT is based on the number of Interrupt supported by the device.
The only way to validate the size getting the number of Interrupt before. i.e
- Find the number of MSI for this device
This is the only thing which I think is currently problematic (the rest we know).
AIUI the intention for PCI devices was that we would learn this around the time dom0 makes the PHYSDEVOP_pci_device_add call (or perhaps XEN_DOMCTL_assign_device or some other function for non-PCI devices).
The doc at the moment says:
- Find number of vectors (nrvecs) for this device by querying PCI helper function
I don't recall if this was in draftC or is based on feedback since then. In any case I've changed it to say
- Find number of vectors from its_device struct.
and added a note:
XXX Number of vectors contains in struct its_device needs to have been communicated from dom0 at some point, e..g by PHYSDEVOP_pci_device_add call or XEN_DOMCTL_assign_device or some other scheme.
Quoted 2 lines
- Compute the theorical size of the ITT
- Validate the ITT IPA and the ITT size
Do we need to validate against the theoretical size, or just again the amount of memory the guest has or?
If we don't actually store anything in the ITT then we may be able just not care about the size.
Quoted 9 lines · Vijay Kilari
Quoted 6 lines
## pITS Scheduling
A pITS scheduling pass is attempted:
* On write to any virtual
CWRITERiff that write results in there being new outstanding requests for that vits;You mean, scheduling pass (softirq trigger) is triggered iff there is no
ongoing requests from that vits?
Yes, this has changed with the switch to only a single outstanding batch. I went with:
* On write to any virtual CWRITER iff that write results in there being new outstanding requests for that vits which could be consumed by the pits (i.e. subject to only a single batch only being permitted by the scheduler);
Although implementationwise it may be OK to defer that decision to the scheduler, rather than try to figure it out in the mmio trap.
Quoted 8 lines
Quoted 8 lines
* On read from a virtual
CREADRiff there are commands outstanding on that vits;
* On receipt of an interrupt notification arising from Xen's own use ofINT; (see discussion under Completion)
* On any interrupt injection arising from a guests use of theINTcommand; (XXX perhaps, see discussion under Completion)
Quoted 8 lines
Quoted 4 lines
This may result in lots of contention on the scheduler locking. Therefore we consider that in each case all which happens is triggering of a softirq which will be processed on return to guest, and just once even for multiple events.
Is it required to have all the cases to trigger scheduling pass? Just on CWRITER if no ongoing request and on Xen's own completion INT is not sufficient?
I think CREADR is needed too, so the guest sees up to date info.
And on injection arising from the guest use of INT is marked as optional here and considered later on. Whether it is needed depends on the decision there.
Quoted 6 lines
[...]
Quoted 5 lines
The second option is likely to be preferable if the issue of selecting a device ID can be addressed.
A secondary question is when these
INTcommands should be inserted into the command stream:
(Nb, this is a list of options, not a list of places where it must be done)
Quoted 5 lines
Quoted 2 lines
* After each batch taken from a single
vits_cq;Is this not enough? because Scheduling pass just sends a one batch of
command with Xen's INT command
It is almost certainly _sufficient_, the question is more whether it is _necessary_ or whether we can reduce the number of interrupts which are required for correct emulation of a vits, iow can we get away with one of the other two options.
The following text argues that only one Xen INT is needed in the stream at any given moment.
Quoted 21 lines
Quoted 21 lines
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.
Quoted 7 lines
Quoted 3 lines
A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
When
PHYSDEVOP_pci_device_addis called, memory forits_devicestructure and other needed structure for this device is allocated added to RB-tree with all necessary information
Sounds like a reasonable time to do it. I added something based on your words.
[...]
Quoted 3 lines
Quoted 2 lines
Format:
MAPC vCID, vTA- The GITS_TYPER.PAtype is emulated as 0.
ITYM GITS_TYPER.PTA?
I've updated various introductory section to reflect the decision to emulate as 0.
Quoted 24 lines
Quoted 24 lines
-
MAPC pCID, pTAphysical ITS command is generated###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
- Callp2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT Size
Quoted 6 lines
Quoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
If Validation bit is set:
I think the proper name for this is just "Valid bit", it just indicates that the entry should be made valid or invalid (i.e. added or removed) rather than requesting any kind of validation.
Quoted 3 lines
- Query
its_devicetree and getits_devicestructure for this device.
- (XXX: If pci device is hidden from dom0, does this device is added withPHYSDEVOP_pci_device_addhypercall?)
We do/will not hide PCI devices from dom0 in the same way we do for platform devices, we should do as for x86 and rely on xen-pciback to bind to the PCI device and keep real drivers away rather than on actual hiding (which will be complex).
So there should always be a PHYSDEVOP_pci_device_add.
If a PCI host-bridge/controller itself is hidden from dom0 then devices behind it will not be available for passthrough.
Quoted 4 lines
- If device does not exists return
- If device exists in RB-tree then
- Validate ITT IPA & ITT size and updateits_devicestruct
- Check if device is already assigned to the domain,
If a device isn't assigned to the domain then we shouldn't be assigning it.
I suspect you actually meant something like if the device is already mapped in the (v)ITS table, but then the following text seems to discount updating the table with a second MAPD after, since it only considers the case that the device is not already mapped.
I didn't update the remainder of this entry since I'm not sure what to change to account for the above.
Ian.
Quoted 25 lines · Ian Campbell
Quoted 25 lines
Quoted 24 lines
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
Quoted 6 lines
Quoted 3 lines
When
PHYSDEVOP_pci_device_addis called, memory forits_devicestructure and other needed structure for this device is allocated added to RB-tree with all necessary informationSounds like a reasonable time to do it. I added something based on your words.
Hmmm... The RB-tree suggested is per domain not the host and indexed with the vDevID.
This is the only way to know quickly if the domain is able to use the device and retrieving a device. Indeed, the vDevID won't be equal to the pDevID as the vBDF will be different to the pBDF.
PHYSDEVOP_pci_device_add is to ask Xen managing the PCI device. At that time we don't know to which domain the device will be passthrough.
Regards,
Signature · 1 line
Julien Grall
Quoted 30 lines · Julien Grall
Quoted 29 lines · Ian Campbell
Quoted 28 lines
Quoted 21 lines
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.Quoted 3 lines
A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
When
PHYSDEVOP_pci_device_addis called, memory forits_devicestructure and other needed structure for this device is allocated added to RB-tree with all necessary information
Quoted 5 lines
Quoted 2 lines
Sounds like a reasonable time to do it. I added something based on your words.
Hmmm... The RB-tree suggested is per domain not the host and indexed with the vDevID.
I added "The ID is per domain and therefore the datastructure should be too." before "Possible efficient..."
Quoted 6 lines
This is the only way to know quickly if the domain is able to use the device and retrieving a device. Indeed, the vDevID won't be equal to the pDevID as the vBDF will be different to the pBDF.
PHYSDEVOP_pci_device_addis to ask Xen managing the PCI device. At that time we don't know to which domain the device will be passthrough.
Yes, I suppose we can allocate at PHYSDEVOP_pci_device_add time, but linking it into the R-B tree will have to happen at assignment time.
This section now ends:
When PHYSDEVOP_pci_device_add is called, memory for its_device structure and other needed structure for this device is allocated.
When XEN_DOMCTL_assign_device is called the device will be added to the per domain RB-tree with all necessary information.
Ian.
Quoted 14 lines · Julien Grall
Quoted 13 lines · Ian Campbell
Quoted 13 lines
Quoted 13 lines
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Quoted 7 lines
Quoted 7 lines
Quoted 7 lines
Quoted 7 lines
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.
How about using radix-tree instead of RB-tree?
Quoted 12 lines
Quoted 11 lines
Quoted 8 lines
Quoted 4 lines
A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
When
PHYSDEVOP_pci_device_addis called, memory forits_devicestructure and other needed structure for this device is allocated added to RB-tree with all necessary informationSounds like a reasonable time to do it. I added something based on your words.
Quoted 6 lines
Hmmm... The RB-tree suggested is per domain not the host and indexed with the vDevID.
This is the only way to know quickly if the domain is able to use the device and retrieving a device. Indeed, the vDevID won't be equal to the pDevID as the vBDF will be different to the pBDF.
Yes, vBDF is converted to pBDF to match DevID
Quoted 3 lines
PHYSDEVOP_pci_device_addis to ask Xen managing the PCI device. At that time we don't know to which domain the device will be passthrough.
PHYSDEVOP_pci_device_add will only add its_device to global radix tree list.
When MAPD is received, its_device is removed from global list and added to per domain list. When domain releases the device, its_device is added back to global list. is it ok?
Quoted 47 lines · Vijay Kilari
Quoted 14 lines · Julien Grall
Quoted 13 lines · Ian Campbell
Quoted 13 lines
Quoted 13 lines
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Quoted 7 lines
Quoted 7 lines
Quoted 7 lines
Quoted 7 lines
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.How about using radix-tree instead of RB-tree?
Quoted 12 lines
Quoted 11 lines
Quoted 8 lines
Quoted 4 lines
A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
When
PHYSDEVOP_pci_device_addis called, memory forits_devicestructure and other needed structure for this device is allocated added to RB-tree with all necessary informationSounds like a reasonable time to do it. I added something based on your words.
Quoted 6 lines
Hmmm... The RB-tree suggested is per domain not the host and indexed with the vDevID.
This is the only way to know quickly if the domain is able to use the device and retrieving a device. Indeed, the vDevID won't be equal to the pDevID as the vBDF will be different to the pBDF.
Yes, vBDF is converted to pBDF to match DevID
Quoted 1 line
Quoted 8 lines
Quoted 2 lines
PHYSDEVOP_pci_device_addis to ask Xen managing the PCI device. At that time we don't know to which domain the device will be passthrough.
PHYSDEVOP_pci_device_addwill only addits_deviceto global radix tree list.When MAPD is received,
its_deviceis removed from global list and added to per domain list. When domain releases the device,its_deviceis added back to global list. is it ok?
I suspect we might need two list (or tree) entries for each its_device, one for the pDevice mapping and one for the vDevice mapping. We may even want a third for vCollection membership, I'm not sure.
Either way I don't think it'll be a big deal, the need or not for each of those will fall out in the wash from the rest of the design, I think.
Based on the amount of discussion on draftC and the fact that we are still finding new areas of complexity I'm going to take a step back and try something simpler and see if I can come up with something which we can get done for 4.6. I'll try and get a new draft reflecting that out ASAP.
(I have my edits from the feedback on draftC so far in git, so if it doesn't work we can always take up this one again...)
Hi Ian,
NIT: You used my Linaro email which I think is de-activated now :).
Quoted 86 lines · Ian Campbell
Here follows draft C based on previous feedback.
Also at:
http://xenbits.xen.org/people/ianc/vits/draftC.{pdf,html}
I think I've captured most of the previous discussion, except where explicitly noted by XXX or in other replies, but please do point out places where I've missed something.
One area where I am pretty sure I've dropped the ball is on the completion and update of
CREADR. That conversation ended up bifurcating along the 1:N vs N:N mapping scheme lines, and I didn't manage to get the various proposals straight. Since we've now agreed on N:N hopefully we can reach a conclusion (no pun intended) on the completion aspect too (sorry that this probably means rehasing at least a subset of the previous thread).Ian.
% Xen on ARM vITS Handling
% Ian Campbell <[email protected]>
% Draft C# Changelog
## Since Draft B
* Details of command translation (thanks to Julien and Vijay)
* Added background on LPI Translation and Pending tablesd
* Added background on Collections
* Settled onN:Nscheme for vITS:pITS mapping.
* Rejigged section nesting a bit.
* Since we now thing translation should be cheap, settle on translation at scheduling time.
* LazyINVALLandSYNC## Since Draft A
* Added discussion of when/where command translation occurs.
* Contention on scheduler lock, suggestion to use SOFTIRQ.
* Handling of domain shutdown.
* More detailed discussion of multiple vs single vits pros/cons.# Introduction
ARM systems containing a GIC version 3 or later may contain one or more ITS logical blocks. An ITS is used to route Message Signalled interrupts from devices into an LPI injection on the processor.
The following summarises the ITS hardware design and serves as a set of assumptions for the vITS software design. (XXX it is entirely possible I've horribly misunderstood how this stuff fits together). For full details of the ITS see the "GIC Architecture Specification".
## Device Identifiers
Each device using the ITS is associated with a unique identifier.
The device IDs are typically described via system firmware, e.g. the ACPI IORT table or via device tree.
The number of device ids is variable and can be discovered via
GITS_TYPER.Devbits. This field allows an ITS to have up to 2^32 device.## Interrupt Collections
Each interrupt is a member of an Interrupt Collection. This allows software to manage large numbers of physical interrupts with a small number of commands rather than issuing one command per interrupt.
On a system with N processors, the ITS must provide at least N+1 collections.
## Target Addresses
The Target Address correspond to a specific GIC re-distributor. The format of this field depends on the value of the
GITS_TYPER.PTAbit:* 1: the base address of the re-distributor target is used
* 0: a unique processor number is used. The mapping between the processor affinity value (MPIDR) and the processor number is discoverable viaGICR_TYPER.ProcessorNumber.
Quoted 5 lines
## ITS Translation Table
Message signalled interrupts are translated into an LPI via an ITS translation table which must be configured for each device which can generate an MSI.
I'm not sure what is the ITS Table Table. Did you mean Interrupt Translation Table?
Quoted 2 lines
The ITS translation table maps the device id of the originating devic
s/devic/device/?
Quoted 65 lines
into an Interrupt Collection and then into a target address.
## ITS Configuration
The ITS is configured and managed, including establishing and configuring Translation Table for each device, via an in memory ring shared between the CPU and the ITS controller. The ring is managed via the
GITS_CBASERregister and indexed byGITS_CWRITERandGITS_CREADRregisters.A processor adds commands to the shared ring and then updates
GITS_CWRITERto make them visible to the ITS controller.The ITS controller processes commands from the ring and then updates
GITS_CREADRto indicate the the processor that the command has been processed.Commands are processed sequentially.
Commands sent on the ring include operational commands:
* Routing interrupts to processors;
* Generating interrupts;
* Clearing the pending state of interrupts;
* Synchronising the command queueand maintenance commands:
* Map device/collection/processor;
* Map virtual interrupt;
* Clean interrupts;
* Discard interrupts;The field
GITS_CBASER.Sizeencodes the number of 4KB pages minus 0 consisting of the command queue. This field is 8 bits which means the maximum size is 2^8 * 4KB = 1MB. Given that each command is 32 bytes, there is a maximum of 32768 commands in the queue.The ITS provides no specific completion notification mechanism. Completion is monitored by a combination of a
SYNCcommand and either pollingGITS_CREADRor notification via an interrupt generated via theINTcommand.Note that the interrupt generation via
INTrequires an originating device ID to be supplied (which is then translated via the ITS into an LPI). No specific device ID is defined for this purpose and so the OS software is expected to fabricate one.Possible ways of inventing such a device ID are:
* Enumerate all device ids in the system and pick another one;
* Use a PCI BDF associated with a non-existent device function (such as an unused one relating to the PCI root-bridge) and translate that (via firmware tables) into a suitable device id;
* ???## LPI Configuration Table
Each LPI has an associated configuration byte in the LPI Configuration Table (managed via the GIC Redistributor and placed at
GICR_PROPBASERorGICR_VPROPBASER). This byte configures:* The LPI's priority;
* Whether the LPI is enabled or disabled.
Quoted 6 lines
Software updates the Configuration Table directly but must then issue an invalidate command (per-device
INVITS command, globalINVALLITS command or writeGICR_INVLPIR) for the affect to be guaranteed to become visible (possibly requiring an ITSSYNCcommand to ensure completion of theINVorINVALL). Note that it is valid for an implementaiton to reread the configuration table at any time (IOW it
s/implementaition/implementation/
Quoted 1 line
is _not_ guarenteed that a change to the LPI Configuration Table won't
s/guarenteed/guaranteed/? Or may the first use of this word was wrong?
Quoted 17 lines
be visible until an invalidate is issued).
## LPI Pending Table
Each LPI also has an associated bit in the LPI Pending Table (managed by the GIC redistributor). This bit signals whether the LPI is pending or not.
# vITS
A guest domain which is allowed to use ITS functionality (i.e. has been assigned pass-through devices which can generate MSIs) will be presented with a virtualised ITS.
Accesses to the vITS registers will trap to Xen and be emulated and a virtualised Command Queue will be provided.
Quoted 7 lines
Commands entered onto the virtual Command Queue will be translated into physical commands, as described later in this document.
XXX there are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are not currently considered here. XXX Should they be/do they need to be?
I think we began to cover these aspect with the section "command emulation".
Quoted 40 lines
# Requirements
Emulation should not block in the hypervisor for extended periods. In particular Xen should not busy wait on the physical ITS. Doing so blocks the physical CPU from doing anything else (such as scheduling other VCPUS)
There may be multiple guests which have a vITS, all targeting the same underlying pITS. A single guest VCPU should not be able to monopolise the pITS via its vITS and all guests should be able to make forward progress.
# vITS to pITS mapping
A physical system may have multiple physical ITSs.
We assume that a given device is only associated with one pITS.
A guest which is given access to multiple devices associated with multiple pITSs will need to be given virtualised access to all associated pITSs.
There are several possible models for achieving this:
*
1:N: One virtual ITS tired to multiple physical ITS.
*N:N: One virtual ITS per physical ITS.
*M:N: Multiple virtual ITS tied to a differing number of physical ITSs.This design assumes an
N:Nmodel, which is thought to be simpler on the Xen side since it avoids questions of how to fairly schedule commands in the1:Nmodel while avoiding starvation as well as simplifying the virtualisation of global commands such asINVALLorSYNC.The
N:Nmodel is also a better fit for I/O NUMA systems.Since the choice of model is internal to the hypervisor/tools and is communicated to the guest via firmware tables we are not tied to this model as an ABI if we decide to change.
Quoted 6 lines
New toolstack domctls or extension to existing domctls will likely be required to allow the toolstack to determine the number of vITS which will be required for the guest and to determine the mapping for passed-through devices.
# LPI Configuration Table Virtualistion
s/Virtualistion/Virtualisation/
Quoted 71 lines
A guest's write accesses to its LPI Configuration Table (which is just an area of guest RAM which the guest has nominated) will be trapped to the hypervisor, using stage 2 MMU permissions, in order for changes to be propagated into the physical LPI Configuration Table.
A host wide LPI dirty bit map, with 1 bit per LPI, will be maintained which indicates whether an update to the physical LPI Configuration Table has been flushed (via an invalidate command). The corresponding bit will be set whenever a guest changes the configuration of an LPI.
This dirty bit map will be used during the handling of relevant ITS Commands (
INV,INVALLetc).Note that no invalidate is required during the handling of an LPI Configuration Table trap.
# Command Queue Virtualisation
The command queue of each vITS is represented by a data structure:
struct
vits_cq{
list_headschedule_list; /* Queued onto pits.schedule_list */
uint32_tcreadr; /* Virtual creadr */
uint32_tcwriter; /* Virtual cwriter */
uint32_tprogress; /* Index of last command queued to pits */
[ Reference to command queue memory ]
};Each pITS has an associated data structure:
struct pits { list_head schedule_list; /* Contains list of vitq_cq.schedule_lists */ uint32_t last_creadr; };On write to the virtual
CWRITERthe cwriter field is updated and if that results in there being new outstanding requests then thevits_cqis enqueued onto pITS'schedule_list(unless it is already there).On read from the virtual
CREADRiff thevits_cqis such that commands are outstanding then a scheduling pass is attempted (in order to updatevits_cq.creadr). The current value ofvitq_cq.creadris then returned.## Command translation
In order to virtualise the Command Queue each command must be translated (this is described in the GIC spec).
Translation of certain commands is potentially expensive, however we will attempt to arrange things (data structures etc) such that the overhead a translation time is minimised (see later).
Translation can be done in two places:
* During scheduling.
* On write toCWRITER, into a pervits_cqqueue which the scheduler then propagates to the pits.Doing the translate during scheduling means that potentially expensive operations may be accounted to
current, who may have nothing to do with those operations (this is true whether it is IRQ context or SOFTIRQ context).Doing the translate during
CWRITERemulation accounts it to the right place, but introduces a potentially long synchronous operation which ties down a VCPU. Introducing batching here means we have essentially the same issue wrt when to replenish the translated queue as doing translate during scheduling.
Quoted 5 lines
Translate during
CWRITERalso has memory overheads. Unclear if they are at a problematic scale or not.Since we have arranged for translation overheads to be minimised it seems that translation during scheduling should be tollerable.
s/tollerable/tolerable/
Quoted 176 lines
## pITS Scheduling
A pITS scheduling pass is attempted:
* On write to any virtual
CWRITERiff that write results in there being new outstanding requests for that vits;
* On read from a virtualCREADRiff there are commands outstanding on that vits;
* On receipt of an interrupt notification arising from Xen's own use ofINT; (see discussion under Completion)
* On any interrupt injection arising from a guests use of theINTcommand; (XXX perhaps, see discussion under Completion)This may result in lots of contention on the scheduler locking. Therefore we consider that in each case all which happens is triggering of a softirq which will be processed on return to guest, and just once even for multiple events.
Such deferral could be considered OK (XXX ???) for the
CREADRcase because at worst the value read will be one cycle out of date. A guest which receives anINTnotification might reasonably expect a subsequent read ofCREADRto reflect that. However that should be covered by the softint processing which would occur on entry to the guest to inject theINT.Each scheduling pass will:
* Read the physical
CREADR;
* For each command betweenpits.last_creadrand the newCREADRvalue process completion of that command and update the correspondingvits_cq.creadr.
* Attempt to refill the pITS Command Queue (see below).## Domain Shutdown
We can't free a
vits_cqwhile has things on the physical control queue, and we cannot cancel things which are on the control queue.So we must wait.
Obviously don't enqueue anything new onto the pits if
d->is_dying.
domain_relinquish_resources()waits (somehow, with suitable continuations etc) for anything which thevits_cqhas outstanding to be completed so that the datastructures can be cleared.## Filling the pITS Command Queue.
Various algorithms could be used here. For now a simple proposal is to traverse the
pits.schedule_liststarting from where the last refill finished (i.e not from the top of the list each time).In order to simplify bookkeeping and to bound the amount of time spent on a single scheduling pass each
vitq_cqwill only have a single batch of commands enqueued with the PITs at a time.If a
vits_cqhas no pending commands then it is removed from the list.If a
vits_cqalready has commands enqueued with the pITS Command Queue then it is skipped.If a
vits_cqhas some pending commands thenmin(pits-free-slots, vits-outstanding, VITS_BATCH_SIZE)will be taken from the vITS command queue, translated and placed onto the pITS queue.vits_cq.progresswill be updated to reflect this.Each
vits_cqis handled in turn in this way until the pITS Command Queue is full, there are no more outstanding commands or each activevits_cqhas commands enqueued with the pITS.There will likely need to be a data structure which shadows the pITS Command Queue slots with references to the
vits_cqwhich has a command currently occupying that slot and corresponding the index into the virtual command queue, for use when completing a command.
VITS_BATCH_SIZEshould be small, TBD say 4 or 8.## Completion
It is expected that commands will normally be completed (resulting in an update of the corresponding
vits_cq.creadr) via guest read fromCREADR. This will trigger a scheduling pass which will ensure thevits_cq.creadrvalue is up to date before it is returned.A guest which does completion via the use of
INTcannot observeCREADRwithout reading it, so updating on read fromCREADRsuffices from the point of view of the guests observation of the state. (Of course we will inject the interrupt at the designated point and the guest may well then readCREADR)However in order to keep the pITS Command Queue moving along we need to consider what happens if there are no
INTbased events nor reads fromCREADRto drive completion and therefore refilling of the Queue with other outstanding commands.A guest which enqueues some commands and then never checks for completion cannot itself block things because any other guest which reads
CREADRwill drive completion. However if _no_ guest reads fromCREADRthen completion will not occur and this must be dealt with.Even if we include completion on
INT-base interrupt injection then it is possible that the pITS queue may not contain any such interrupts, either because no guest is using them or because the batching means that none of them are enqueued on the active ring at the moment.So we need a fallback to ensure that queue keeps moving. There are several options:
* A periodic timer in Xen which runs whenever there are outstanding commands in the pITS. This is simple but pretty sucky.
* Xen injects its ownINTcommands into the pITS ring. This requires figuring out a device ID to use.The second option is likely to be preferable if the issue of selecting a device ID can be addressed.
A secondary question is when these
INTcommands should be inserted into the command stream:* After each batch taken from a single
vits_cq;
* After each scheduling pass;
* One active in the command stream at any given time;The latter should be sufficient, by arranging to insert a
INTinto the stream at the end of any scheduling pass which occurs while there is not a currently outstandingINTwe have sufficient backstop to allow us to refill the ring.This assumes that there is no particular benefit to keeping the
CWRITERrolling ahead of the pITS's actual processing. This is true because the ITS operates on commands in the order they appear in the queue, so there is no need to maintain a runway ahead of the ITS processing. (XXX If this is a concern perhaps the INT could be inserted at the head of the final batch of commands in a scheduling pass instead of the tail).Xen itself should never need to issue an associated
SYNCcommand, since the individual guests would need to issue those themselves when they care. TheINTonly serves to allow Xen to enqueue new commands when there is space on the ring, it has no interest itself on the actual completion.## Locking
It may be preferable to use
atomic_ttypes for various fields (e.g.vits_cq.creadr) in order to reduce the amount and scope of locking required.# ITS Command Translation
This section is based on the section 5.13 of GICv3 specification (PRD03-GENC-010745 24.0). The goal is to provide insight of the cost to emulate ITS commands in Xen.
The ITS provides 12 commands in order to manage interrupt collections, devices and interrupts. Possible command parameters are device ID (
ID), Event ID (vID), Collection ID (vCID), Target Address (vTA) parameters.These parameters need to be validated and translated from Virtual to Physical.
## Parameter Validation / Translation
Each command contains parameters that needs to be validated before any usage in Xen or passing to the hardware.
### Device ID (
ID)This parameter is used by commands which manage a specific device and the interrupts associated with that device. Checking if a device is present and retrieving the data structure must be fast.
Quoted 6 lines
The device identifiers may not be assigned contiguously and the maximum number is very high (2^32).
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Well, the deviceID is computed from the BDF and some DMA alias. As the algorithm can't be tweaked, it's very likely that we will have non-contiguous Device ID. See pci_for_each_dma_alias in Linux (drivers/pci/search.c).
Quoted 14 lines
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
### Event ID (
vID)
Quoted 7 lines
This is the per-device Interrupt identifier (i.e. the MSI index). It is configured by the device driver software.
It is not necessary to translate a
vID, however they may need to be represented in various data structures given to the pITS.XXX is any of this true?
Right, the vID will always be equal to the pID. Although you will need to associate a physical LPI for every pair (vID, DevID).
Quoted 8 lines
### Interrupt Collection (
vCID)This parameter is used in commands which manage collections and interrupt in order to move them for one CPU to another. The ITS is only mandated to implement N + 1 collections where N is the number of processor on the platform (i.e max number of VCPUs for a given guest). Furthermore, the identifiers are always contiguous.
Quoted 4 lines
If we decide to implement the strict minimum (i.e N + 1), an array is enough and will allow operations in O(1).
XXX Could forgo array and go straight to vcpu_info/domain_info.
Not really, the number of collection is always one higher than the number of VCPUs. How would you store the last collection?
Quoted 13 lines
### Target Address (
vTA)This parameter is used in commands which manage collections. It is a unique identifier per processor. The format is different following the value of the
GITS_TYPER.PTAbit . The value of the field is fixed by the ITS implementation and the software has to handle the 2 cases.A solution with
GITS_TYPER.PTAset to one will require some computation in order to find the VCPU associated with the redistributor address. It will be similar toget_vcpu_from_rdistin the vGICv3 emulation (xen/arch/arm/vgic-v3.c).
Quoted 5 lines
On another hand, setting GITS_TYPER.PTA to zero will give us control to decide the linear process number which could simply be the
vcpu_id(always linear).XXX Non-linear VCPUs e.g. via AFFR1 hierarchy?
No matter of the number of affinity levels we will handle, the vcpu_id will always be linear as it's used as an index in an array.
Quoted 8 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.
INVALL and SYNC are not global. They both take a parameter: vCID for INVALL and vTarget for SYNC.
INVALL ensures that any interrupts in the specified collection are re-load. SYNC ensures that all the previous command, and all outstanding physical actions relating to the specified re-distributor are completed.
Quoted 8 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA-
MAPC pCID, pTAphysical ITS command is generated
We should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot.
This command should only assign a pCID to the vCID.
Quoted 7 lines
###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.
Another case: The ITT is replaced. This use case needs more care because we need to ensure that all the interrupt are disabled before switching to the new ITT.
Quoted 10 lines
If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
XXX: The MAPD command is using a virtual DevID which is different that the pDevID (because the BDF is not the same). How do you find the corresponding translation?
Quoted 3 lines
- Call
p2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT Size
I had some though about the other validation problem with the ITT. The region will be used by the ITS to store the mapping between the ID and the LPI as long as some others information.
I guess that if the OS is playing with the ITT (such as writing in it) the ITS will behave badly. We have to ensure to the guest will never write in it and by the same occasion that the same region is not passed to 2 devices.
Quoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
Some of the informations can even be setup when the PCI device is added to Xen (such as the number of MSI supported and physical LPIs chunk).
Quoted 8 lines
If Validation bit is not set:
- Validate if the device exits by checking vITS device list
- Clear allvlpisassigned for this device
- Remove this device from vITS list
- Free memoryXXX If preallocation presumably shouldn't free here either.
Right. We could use a field to say if the device is activated or not.
Quoted 4 lines
###
MAPVI/MAPICommand translationFormat:
MAPVI device, ID, vID, vCID
Actually the 2 commands are completely different:
- MAPI maps a (DevID, ID) to a collection
- MAVI maps a (DevID, ID) to a collection and an LPI.
The process described below is only about MAPVI.
Also what about interrupt re-mapping?
Quoted 2 lines
- Validate if the device exits by checking vITS device list
s/exits/exists/
Quoted 5 lines
- Validate vCID and get pCID by searching
cid_map- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pID
What if the vID is already used by another
Quoted 9 lines
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCIDHere the overhead is allocating physical ID, allocate memory for irq descriptor and routing interrupt.
XXX Suggested to preallocate?
Right. We may also need to have a separate routing for LPIs as the current function is quite long to execute.
I was thinking into routing the interrupt at device assignation (assuming we allocate the pLPIs at that time). And only set the mapping to vLPIs when the MAPI is called.
Quoted 2 lines
###
INVALLCommand translation
The format of INVALL is INVALL collection
Quoted 4 lines
A physical
INVALLis only generated if the LPI dirty bitmap has any bits set. Otherwise it is skipped.XXX Perhaps bitmap should just be a simple counter?
We would need to handle it per collection.
Quoted 5 lines
XXX bitmap is host global, a per-domain bitmap would allow us to elide
INVALLunless an LPI associated with the guest making the request was dirty. Would also need some sort of "ITS INVALL" clock in order that other guests can elide their ownINVALLif one has already happened. Complexity not worth it at this stage?
Given that I just discovered that INVALL is also taking a collection in parameter, it will likely be more complex.
Quoted 2 lines
###
SYNCCommand translation
The format of SYNC is SYNC target. It's only ensure the completion for a re-distributor.
Although, the pseudo-code (see perform_sync in 5.13.22 in PRD03-GENC-010745 24.0) seems to say it waits for all re-distributor... I'm not sure what to trust.
Quoted 4 lines
Can be omitted from the physical command stream if the previous command was also a
SYNC, i.e. due to a guest sending a series ofSYNCcommands or one guest's batch ending with one and the nexts beggining.
s/beggining/beginning/
Regards,
Signature · 1 line
Julien Grall
Quoted 3 lines · Julien Grall
Hi Ian,
NIT: You used my Linaro email which I think is de-activated now :).
I keep finding new address books with that address in them!
Quoted 8 lines
Quoted 5 lines
## ITS Translation Table
Message signalled interrupts are translated into an LPI via an ITS translation table which must be configured for each device which can generate an MSI.
I'm not sure what is the ITS Table Table. Did you mean Interrupt Translation Table?
I don't think I wrote Table Table anywhere.
I'm referring to the tables which are established by e.g. the MAPD command and friends, e.g. the thing shown in "4.9.12 Notional ITS Table Structure".
Quoted 3 lines
Quoted 1 line
is _not_ guarenteed that a change to the LPI Configuration Table won't
s/guarenteed/guaranteed/? Or may the first use of this word was wrong?
guaranteed is correct, I can never remember it though.
Quoted 6 lines
Quoted 4 lines
XXX there are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are not currently considered here. XXX Should they be/do they need to be?
I think we began to cover these aspect with the section "command emulation".
Some aspects, yes. I went with:
There are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are only considered here to the extent needed for describing the vITS emulation.
Quoted 8 lines
Quoted 3 lines
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Well, the deviceID is computed from the BDF and some DMA alias. As the algorithm can't be tweaked, it's very likely that we will have non-contiguous Device ID. See
pci_for_each_dma_aliasin Linux (drivers/pci/search.c).
The implication here is that deviceID is fixed in hardware and is used by driver domain software in contexts where we do not get the opportunity to translate is that right? What contexts are those?
Note that the BDF is also something which we could in principal virtualise (we already do for domU). Perhaps that is infeasible for dom0 though?
That gives me two thoughts.
The first is that although device identifiers are not necessarily contiguous, they are generally at least grouped and not allocated at random through the 2^32 options. For example a PCI Host bridge typically has a range of device ids associated with it and each device has a device id derived from that.
I'm not sure if we can leverage that into a more useful data structure than an R-B tree, or for example to arrange for the R-B to allow for the translation of a device within a span into the parent span and from there do the lookup. Specifically when looking up a device ID corresponding to a PCI device we could arrange to find the PCI host bridge and find the actual device from there. This would keep the RB tree much smaller and therefore perhaps quicker? Of course that depends on what the lookup from PCI host bridge to a device looked like.
The second is that perhaps we can do something simpler for the domU case, if we were willing to tolerate it being different from dom0.
Quoted 17 lines
Quoted 17 lines
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
### Event ID (
vID)This is the per-device Interrupt identifier (i.e. the MSI index). It is configured by the device driver software.
Quoted 8 lines
Quoted 4 lines
It is not necessary to translate a
vID, however they may need to be represented in various data structures given to the pITS.XXX is any of this true?
Right, the vID will always be equal to the pID. Although you will need to associate a physical LPI for every pair (vID, DevID).
I think in the terms defined by this document that is (ID, vID) => an LPI. Right?
Have we considered how this mapping will be tracked?
Quoted 8 lines
Quoted 8 lines
### Interrupt Collection (
vCID)This parameter is used in commands which manage collections and interrupt in order to move them for one CPU to another. The ITS is only mandated to implement N + 1 collections where N is the number of processor on the platform (i.e max number of VCPUs for a given guest). Furthermore, the identifiers are always contiguous.
Quoted 7 lines
Quoted 4 lines
If we decide to implement the strict minimum (i.e N + 1), an array is enough and will allow operations in O(1).
XXX Could forgo array and go straight to vcpu_info/domain_info.
Not really, the number of collection is always one higher than the number of VCPUs. How would you store the last collection?
In domain_info. What I meant was:
if ( vcid == domain->nr_vcpus )
return domain->interrupt_collection
else if ( vcid < domain_nr_vcpus )
return domain->vcpus[vcid]->interrupt_colleciton
else
invalid vcid.Similar to how SPI vs PPI interrupts are handled.
Quoted 11 lines
Quoted 8 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.INVALL and SYNC are not global. They both take a parameter: vCID for INVALL and vTarget for SYNC.
By global I meant not associated with a specific device. I went with:
INVALL and SYNC are not specific to a given device (they are per collection per target respectively) and are therefore potentially disruptive to other guests and so need consideration.
Quoted 8 lines
INVALL ensures that any interrupts in the specified collection are re-load. SYNC ensures that all the previous command, and all outstanding physical actions relating to the specified re-distributor are completed.
Quoted 3 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.
Quoted 8 lines
Quoted 5 lines
###
MAPCcommand translationFormat:
MAPC vCID, vTA-
MAPC pCID, pTAphysical ITS command is generatedWe should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot.
What is the plan for this start of day mapping? One collection per pCPU and ignore the rest?
It seems (section 4.9.2) that there are two potential kinds of collections, ones internal to the ITS and others where data is held in external memory. The numbers of both are limited by the hardware.
I suppose the internal ones will be faster.
Supposing that a guest is likely to use collections to map interrupts to specific vcpus, and that the physical collections will be mapped to pcpus, I suppose this means we will need to do some relatively expensive remapping (corresponding to moving the IRQ to another collection) in arch_move_irqs? Is that the best we can do?
Quoted 1 line
This command should only assign a pCID to the vCID.
Does it not also need to remap some interrupts to that new pCID?
Quoted 11 lines
Quoted 7 lines
###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.Another case: The ITT is replaced. This use case needs more care because we need to ensure that all the interrupt are disabled before switching to the new ITT.
I've added a note since I think this is going to be a discussion in the other sub thread.
Quoted 12 lines
Quoted 11 lines
If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
Quoted 3 lines
XXX: The MAPD command is using a virtual DevID which is different that the pDevID (because the BDF is not the same). How do you find the corresponding translation?
Not sure, do we need a per-domain thing mapping vBDF to $something? Do we alreayd have such a thing, e.g. in the SMMU code?
I've added a note.
Quoted 8 lines
Quoted 4 lines
- Call
p2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT SizeI had some though about the other validation problem with the ITT. The region will be used by the ITS to store the mapping between the ID and the LPI as long as some others information.
ITYM "as well as some other information"?
Quoted 4 lines
I guess that if the OS is playing with the ITT (such as writing in it) the ITS will behave badly. We have to ensure to the guest will never write in it and by the same occasion that the same region is not passed to 2 devices.
I don't think we will be exposing the physical ITT to the guest, will we? That will live in memory which Xen owns and controls and doesn't share with any guest.
In fact, I don't know that a vITS will need an ITT memory at all, i.e. most of our GITS_BASERn will be unimplemented.
In theory we could use these registers to offload some of the data structure storage requirements to the guest, but that would require great care to validate any time we touched it (or perhaps just p2m==r/o), I think it is probably not worth the stress if we can just use regular hypervisor side data structures instead? (This stuff is just there for the h/w ITS which doesn't have the luxury of xmalloc).
Quoted 8 lines
Quoted 5 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
Some of the informations can even be setup when the PCI device is added to Xen (such as the number of MSI supported and physical LPIs chunk).
Yes, assuming there are sufficient LPIs to allocate in this way. That's not clear though, is it?
Quoted 12 lines
Quoted 8 lines
If Validation bit is not set:
- Validate if the device exits by checking vITS device list
- Clear allvlpisassigned for this device
- Remove this device from vITS list
- Free memoryXXX If preallocation presumably shouldn't free here either.
Right. We could use a field to say if the device is activated or not.
Quoted 1 line
Quoted 7 lines
Quoted 3 lines
###
MAPVI/MAPICommand translationFormat:
MAPVI device, ID, vID, vCIDActually the 2 commands are completely different:
- MAPI maps a (DevID, ID) to a collection
- MAVI maps a (DevID, ID) to a collection and an LPI.
MAPVI for the second one I think?
The difference is that MAPI lacks the vID argument?
Quoted 1 line
The process described below is only about MAPVI.
OK. I've left a placeholder for MAPI.
Quoted 1 line
Also what about interrupt re-mapping?
I don't know, what about it?
Quoted 7 lines
Quoted 5 lines
- Validate vCID and get pCID by searching
cid_map- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pIDWhat if the vID is already used by another
I think Vijay's updates already addressed this.
Quoted 8 lines
Quoted 8 lines
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCIDHere the overhead is allocating physical ID, allocate memory for irq descriptor and routing interrupt.
Quoted 8 lines
Quoted 1 line
XXX Suggested to preallocate?
Right. We may also need to have a separate routing for LPIs as the current function is quite long to execute.
I was thinking into routing the interrupt at device assignation (assuming we allocate the pLPIs at that time). And only set the mapping to vLPIs when the MAPI is called.
Please propose concrete modifications to the text, since I can't figure out what you mean to change here.
Quoted 4 lines
Quoted 3 lines
###
INVALLCommand translation
Quoted 8 lines
The format of INVALL is INVALL collection
Quoted 4 lines
A physical
INVALLis only generated if the LPI dirty bitmap has any bits set. Otherwise it is skipped.XXX Perhaps bitmap should just be a simple counter?
We would need to handle it per collection.
Hrm, this complicates things a bit. Don't we need to invalidate any pCID which has a routing of an interrupt to vCID? i.e. potentially multiple INVALL?
Quoted 8 lines
Quoted 5 lines
XXX bitmap is host global, a per-domain bitmap would allow us to elide
INVALLunless an LPI associated with the guest making the request was dirty. Would also need some sort of "ITS INVALL" clock in order that other guests can elide their ownINVALLif one has already happened. Complexity not worth it at this stage?Given that I just discovered that INVALL is also taking a collection in parameter, it will likely be more complex.
Yes.
Quoted 9 lines
Quoted 3 lines
###
SYNCCommand translationThe format of SYNC is SYNC target. It's only ensure the completion for a re-distributor.
Although, the pseudo-code (seeperform_syncin 5.13.22 in PRD03-GENC-010745 24.0) seems to say it waits for all re-distributor... I'm not sure what to trust.
Yes, it's confusing but the first sentence of 5.13.22 says:
This command specifies that the ITS must wait for completion of internal effects of all previous commands, and all outstanding physical actions relating to the specified re-distributor.
So, by my reading, all redistributors need to have seen the effect of any command issued to the given redistributor (not all commands given to any redistributor).
Example: given command cA issued to redistributor rA and command cB issued to redistrubutor rB and then issuing SYNC(rA) must ensure that cA is visible to _both_ rA and rB, but doesn't say anything regarding cB at all.
Ian.
Quoted 2 lines · Ian Campbell
Quoted 1 line · Julien Grall
Hi Ian,
Hi Ian,
Quoted 6 lines
Quoted 1 line
NIT: You used my Linaro email which I think is de-activated now :).
I keep finding new address books with that address in them!
Quoted 2 lines
Quoted 2 lines
## ITS Translation Table
Quoted 8 lines
Quoted 6 lines
Quoted 3 lines
Message signalled interrupts are translated into an LPI via an ITS translation table which must be configured for each device which can generate an MSI.
I'm not sure what is the ITS Table Table. Did you mean Interrupt Translation Table?
I don't think I wrote Table Table anywhere.
Sorry I meant "ITS translation table"
Quoted 3 lines
I'm referring to the tables which are established by e.g. the MAPD command and friends, e.g. the thing shown in "4.9.12 Notional ITS Table Structure".
On previous paragraph you are referring particularly to "Interrupt Translation Table". This is the only table that is configured per device.
[..]
Quoted 18 lines
Quoted 6 lines
Quoted 4 lines
XXX there are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are not currently considered here. XXX Should they be/do they need to be?
I think we began to cover these aspect with the section "command emulation".
Some aspects, yes. I went with:
There are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are only considered here to the extent needed for describing the vITS emulation.
Quoted 4 lines
Quoted 3 lines
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Quoted 8 lines
Quoted 4 lines
Well, the deviceID is computed from the BDF and some DMA alias. As the algorithm can't be tweaked, it's very likely that we will have non-contiguous Device ID. See
pci_for_each_dma_aliasin Linux (drivers/pci/search.c).The implication here is that deviceID is fixed in hardware and is used by driver domain software in contexts where we do not get the opportunity to translate is that right? What contexts are those?
No, the driver domain software will always use a virtual DeviceID (based on the vBDF and other things). The problem I wanted to raise is how to translate back the vDeviceID to a physical deviceID/BDF.
Quoted 3 lines
Note that the BDF is also something which we could in principal virtualise (we already do for domU). Perhaps that is infeasible for dom0 though?
For DOM0 the virtual BDF is equal to the physical BDF. So the both deviceID (physical and virtual) will be the same.
We may decide to do vBDF == pBDF for guest too in order to simplify the code.
Quoted 7 lines
That gives me two thoughts.
The first is that although device identifiers are not necessarily contiguous, they are generally at least grouped and not allocated at random through the 2^32 options. For example a PCI Host bridge typically has a range of device ids associated with it and each device has a device id derived from that.
Usually it's one per (device, function).
Quoted 9 lines
I'm not sure if we can leverage that into a more useful data structure than an R-B tree, or for example to arrange for the R-B to allow for the translation of a device within a span into the parent span and from there do the lookup. Specifically when looking up a device ID corresponding to a PCI device we could arrange to find the PCI host bridge and find the actual device from there. This would keep the RB tree much smaller and therefore perhaps quicker? Of course that depends on what the lookup from PCI host bridge to a device looked like.
I'm not sure why you are speaking about PCI host bridge. AFAIK, the guest doesn't have a physical host bridge.
Although, this is an optimization that we can think about it later. The R-B will already be fast enough for a first implementation. My main point was about the translation vDeviceID => pDeviceID.
Quoted 23 lines
The second is that perhaps we can do something simpler for the domU case, if we were willing to tolerate it being different from dom0.
Quoted 20 lines
Quoted 20 lines
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
### Event ID (
vID)This is the per-device Interrupt identifier (i.e. the MSI index). It is configured by the device driver software.
It is not necessary to translate a
vID, however they may need to be represented in various data structures given to the pITS.
Quoted 8 lines
Quoted 5 lines
Quoted 1 line
XXX is any of this true?
Right, the vID will always be equal to the pID. Although you will need to associate a physical LPI for every pair (vID, DevID).
I think in the terms defined by this document that is (
ID,vID) => an LPI. Right?
Well, by ID you refer about deviceID? That remind me that the second paragraph of "# ITS Command Translation" is confusing (copy below):
"The ITS provides 12 commands in order to manage interrupt collections, devices and interrupts. Possible command parameters are device ID (ID), Event ID (vID), Collection ID (vCID), Target Address (vTA) parameters."
The spec is using ID for "interrupt ID" and device for deviceID.
In general, the section "command emulation" is using 'v' to refer the virtual identifier and 'p' for the physical identifier. (see pCID vs vCID both are Collection ID).
Quoted 2 lines
Have we considered how this mapping will be tracked?
I don't think so. We need to track the list of event ID enabled for this deviceID and the associated vLPI and LPI.
Although, if allocate a contiguous chunck of LPI it won't be necessary to track the later.
Quoted 18 lines
Quoted 8 lines
Quoted 8 lines
### Interrupt Collection (
vCID)This parameter is used in commands which manage collections and interrupt in order to move them for one CPU to another. The ITS is only mandated to implement N + 1 collections where N is the number of processor on the platform (i.e max number of VCPUs for a given guest). Furthermore, the identifiers are always contiguous.
Quoted 7 lines
Quoted 4 lines
If we decide to implement the strict minimum (i.e N + 1), an array is enough and will allow operations in O(1).
XXX Could forgo array and go straight to vcpu_info/domain_info.
Not really, the number of collection is always one higher than the number of VCPUs. How would you store the last collection?
In
domain_info. What I meant was:
Quoted 8 lines
if ( vcid == domain->nr_vcpus ) return domain->interrupt_collection else if ( vcid < domain_nr_vcpus ) return domain->vcpus[vcid]->interrupt_colleciton else invalid vcid.Similar to how SPI vs PPI interrupts are handled.
Sorry, I didn't understand your suggestion like that.
I think that can work, although the resulting code may be difficult to read/understand because a collection can be moved from one vCPU to another.
Quoted 10 lines
Quoted 10 lines
Quoted 9 lines
## Command Translation
Of the existing GICv3 ITS commands,
MAPC,MAPD,MAPVI/MAPIare potentially time consuming commands as these commands creates entry in the Xen ITS structures, which are used to validate other ITS commands.
INVALLandSYNCare global and potentially disruptive to other guests and so need consideration.
Quoted 8 lines
Quoted 2 lines
INVALL and SYNC are not global. They both take a parameter: vCID for INVALL and vTarget for SYNC.
By global I meant not associated with a specific device. I went with:
INVALLandSYNCare not specific to a given device (they are per collection per target respectively) and are therefore potentially disruptive to other guests and so need consideration.
Thanks for the clarification.
Quoted 13 lines
Quoted 13 lines
INVALL ensures that any interrupts in the specified collection are re-load. SYNC ensures that all the previous command, and all outstanding physical actions relating to the specified re-distributor are completed.
Quoted 7 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA
Quoted 7 lines
Quoted 4 lines
Quoted 1 line
-
MAPC pCID, pTAphysical ITS command is generatedWe should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot.
What is the plan for this start of day mapping? One collection per pCPU and ignore the rest?
To map the only collection per pCPU. And we can see for improvement later.
Quoted 3 lines
It seems (section 4.9.2) that there are two potential kinds of collections, ones internal to the ITS and others where data is held in external memory. The numbers of both are limited by the hardware.
They are all the same. The only difference is for external collection the memory should be allocated by the software.
Quoted 1 line
I suppose the internal ones will be faster.
No idea.
Quoted 5 lines
Supposing that a guest is likely to use collections to map interrupts to specific vcpus, and that the physical collections will be mapped to pcpus, I suppose this means we will need to do some relatively expensive remapping (corresponding to moving the IRQ to another collection) in
arch_move_irqs? Is that the best we can do?
If we use the same solution as SPI/PPIs (i.e arch_move_irqs), yes. But I'm not in favor of this solution which is already expensive for SPI/PPIs (after talking with Dario, vCPU may move often between pCPU).
We could decide to implement a lazy solution (i.e moving the interrupt only when it's firing) but that would require to send ITS command in Xen.
Another idea is to never move the interrupt collection from one pCPU to another. The vCID would always be equal to the same pCID, but the interrupt would be injected to a different processor depending on the associated vTA.
Quoted 4 lines
Quoted 2 lines
This command should only assign a pCID to the vCID.
Does it not also need to remap some interrupts to that new pCID?
That would be very expensive. Another solution would be to always have the same mapping vCID <=> pCID (allocated at boot) and only update the vTA. We would loose the possibility to have LPIs following a vCPU but that would be a small drawback compare to the cost of the ITS.
Quoted 27 lines
Quoted 11 lines
Quoted 7 lines
###
MAPDCommand translationFormat:
MAPD device, Valid, ITT IPA, ITT Size
MAPDis sent withValidbit set if device needs to be added and reset when device is removed.Another case: The ITT is replaced. This use case needs more care because we need to ensure that all the interrupt are disabled before switching to the new ITT.
I've added a note since I think this is going to be a discussion in the other sub thread.
Quoted 12 lines
Quoted 11 lines
If
Validbit is set:- Allocate memory for
its_devicestruct
- Validate ITT IPA & ITT size and updateits_devicestruct
- Find number of vectors(nrvecs) for this device by querying PCI helper function
- Allocate nrvecs number of LPI XXX nrvecs is a function ofITT Size?
- Allocate memory forstruct vlpi_mapfor this device. Thisvlpi_mapholds mapping of Virtual LPI to Physical LPI and ID.
- Find physical ITS node with which this device is associated
Quoted 6 lines
Quoted 3 lines
XXX: The MAPD command is using a virtual DevID which is different that the pDevID (because the BDF is not the same). How do you find the corresponding translation?
Not sure, do we need a per-domain thing mapping vBDF to $something? Do we alreayd have such a thing, e.g. in the SMMU code?
The current SMMU code doesn't have anything related to it. I need to think about it.
Quoted 1 line
I've added a note.
Thanks.
Quoted 10 lines
Quoted 8 lines
Quoted 4 lines
- Call
p2m_lookupon ITT IPA addr and get physical ITT address
- Validate ITT Size
- Generate/format physical ITS command:MAPD, ITT PA, ITT SizeI had some though about the other validation problem with the ITT. The region will be used by the ITS to store the mapping between the ID and the LPI as long as some others information.
ITYM "as well as some other information"?
Yes.
Quoted 9 lines
Quoted 5 lines
I guess that if the OS is playing with the ITT (such as writing in it) the ITS will behave badly. We have to ensure to the guest will never write in it and by the same occasion that the same region is not passed to 2 devices.
I don't think we will be exposing the physical ITT to the guest, will we? That will live in memory which Xen owns and controls and doesn't share with any guest.
That's need to be clarify. The RFC sent by Vijay is letting the guest feeding the physical ITT.
But I just though that it won't work well, the ITT has to be contiguous in the physical memory.
Quoted 8 lines
In fact, I don't know that a vITS will need an ITT memory at all, i.e. most of our
GITS_BASERnwill be unimplemented.
In theory we could use these registers to offload some of the data structure storage requirements to the guest, but that would require great care to validate any time we touched it (or perhaps just p2m==r/o), I think it is probably not worth the stress if we can just use regular hypervisor side data structures instead? (This stuff is just there for the h/w ITS which doesn't have the luxury of xmalloc).
GITS_BASERn is only used to feed internal ITS table such as Collections, Devices, Virtual Processors.
For the ITT, the address is passed via MAPD and as to be allocated by the guest.
We could ignore the address provided by the guest but that would mean the ITT is allocated twice (one by the guest unused, and the Xen one used to feed the pITS). Although, as pointed above the ITT memory region allocated by the guest may not be contiguous in physical memory
Furthermore, if we allocate the ITT in Xen, this command will be quick to emulate (we could send the MAPD command when the device is attached).
So less possible security issue.
Quoted 10 lines
Quoted 7 lines
Quoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
Some of the informations can even be setup when the PCI device is added to Xen (such as the number of MSI supported and physical LPIs chunk).
Yes, assuming there are sufficient LPIs to allocate in this way. That's not clear though, is it?
IHMO it's not an issue. If the ITS doesn't provide enough LPIs a baremetal OS will likely not being able to use a device.
FWIW, Linux is always allocating the LPIs when the device is added based on the PCI cfg.
Quoted 15 lines
Quoted 15 lines
Quoted 9 lines
If Validation bit is not set:
- Validate if the device exits by checking vITS device list
- Clear allvlpisassigned for this device
- Remove this device from vITS list
- Free memoryXXX If preallocation presumably shouldn't free here either.
Right. We could use a field to say if the device is activated or not.
Quoted 3 lines
###
MAPVI/MAPICommand translation
Quoted 7 lines
Quoted 5 lines
Quoted 1 line
Format:
MAPVI device, ID, vID, vCIDActually the 2 commands are completely different:
- MAPI maps a (DevID, ID) to a collection
- MAVI maps a (DevID, ID) to a collection and an LPI.MAPVI for the second one I think?
Right.
Quoted 2 lines
The difference is that MAPI lacks the vID argument?
Yes. And MAPI doesn't bind the (DevID, ID) to an LPIs. The first one can be used to move IRQ from one collection to another.
Quoted 7 lines
Quoted 1 line
The process described below is only about MAPVI.
OK. I've left a placeholder for
MAPI.Quoted 1 line
Also what about interrupt re-mapping?
I don't know, what about it?
It was an open question. It answered to it on the mail to Vijay's.
Quoted 10 lines
Quoted 8 lines
Quoted 6 lines
- Validate vCID and get pCID by searching
cid_map- if vID does not have entry in
vlpi_entriesof this device allocate a new pID fromvlpi_mapof this device and updatevlpi_entrieswith new pIDWhat if the vID is already used by another
I think Vijay's updates already addressed this.
I will give a look.
Quoted 14 lines
Quoted 14 lines
Quoted 10 lines
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCIDHere the overhead is allocating physical ID, allocate memory for irq descriptor and routing interrupt.
XXX Suggested to preallocate?
Right. We may also need to have a separate routing for LPIs as the current function is quite long to execute.
Quoted 6 lines
Quoted 3 lines
I was thinking into routing the interrupt at device assignation (assuming we allocate the pLPIs at that time). And only set the mapping to vLPIs when the MAPI is called.
Please propose concrete modifications to the text, since I can't figure out what you mean to change here.
It's not yet fully clear in my mind.
If we assuming that we have a chunk of LPIs allocate for a the device when it's assigned to the guest, the only missing information is the corresponding vLPIs.
We could decide to setup the internal routing structure (allocation of the irq_guest) and defer the setting of the vLPI. This would work because the interrupt are disabled at boot time and won't be enabled as long as a MAPVI command is sent.
Quoted 10 lines
Quoted 10 lines
Quoted 4 lines
###
INVALLCommand translationThe format of INVALL is INVALL collection
Quoted 3 lines
A physical
INVALLis only generated if the LPI dirty bitmap has any bits set. Otherwise it is skipped.
Quoted 7 lines
Quoted 3 lines
Quoted 1 line
XXX Perhaps bitmap should just be a simple counter?
We would need to handle it per collection.
Hrm, this complicates things a bit. Don't we need to invalidate any pCID which has a routing of an interrupt to vCID? i.e. potentially multiple INVALL?
Not necessarily. If we keep the interrupts of a vCID always in the same pCID, we would need to send only on INVALL.
Quoted 16 lines
Quoted 9 lines
Quoted 3 lines
###
SYNCCommand translationThe format of SYNC is SYNC target. It's only ensure the completion for a re-distributor.
Although, the pseudo-code (seeperform_syncin 5.13.22 in PRD03-GENC-010745 24.0) seems to say it waits for all re-distributor... I'm not sure what to trust.Yes, it's confusing but the first sentence of 5.13.22 says:
This command specifies that the ITS must wait for completion of internal effects of all previous commands, and all outstanding physical actions relating to the specified re-distributor.
Quoted 8 lines
So, by my reading, all redistributors need to have seen the effect of any command issued to the given redistributor (not all commands given to any redistributor).
Example: given command cA issued to redistributor rA and command cB issued to redistrubutor rB and then issuing SYNC(rA) must ensure that cA is visible to _both_ rA and rB, but doesn't say anything regarding cB at all.
Thanks for the explanation.
Regards,
Signature · 1 line
Julien Grall
Quoted 21 lines · Julien Grall
Quoted 2 lines · Ian Campbell
Quoted 1 line · Julien Grall
Hi Ian,
Hi Ian,
Quoted 6 lines
Quoted 1 line
NIT: You used my Linaro email which I think is de-activated now :).
I keep finding new address books with that address in them!
Quoted 2 lines
Quoted 2 lines
## ITS Translation Table
Quoted 8 lines
Quoted 6 lines
Quoted 3 lines
Message signalled interrupts are translated into an LPI via an ITS translation table which must be configured for each device which can generate an MSI.
I'm not sure what is the ITS Table Table. Did you mean Interrupt Translation Table?
I don't think I wrote Table Table anywhere.
Quoted 8 lines
Sorry I meant "ITS translation table"
Quoted 3 lines
I'm referring to the tables which are established by e.g. the MAPD command and friends, e.g. the thing shown in "4.9.12 Notional ITS Table Structure".
On previous paragraph you are referring particularly to "Interrupt Translation Table". This is the only table that is configured per device.
I'm afraid I'm still not getting your point. Please quote the exact text which you think is wrong and if possible suggest an alternative.
Quoted 25 lines
[..]
Quoted 23 lines
Quoted 6 lines
Quoted 4 lines
XXX there are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are not currently considered here. XXX Should they be/do they need to be?
I think we began to cover these aspect with the section "command emulation".
Some aspects, yes. I went with:
There are other aspects to virtualising the ITS (LPI collection management, assignment of LPI ranges to guests, device management). However these are only considered here to the extent needed for describing the vITS emulation.
Quoted 8 lines
Quoted 3 lines
XXX In the context of virtualised device ids this may not be the case, e.g. we can arrange for (mostly) contiguous device ids and we know the bound is significantly lower than 2^32
Well, the deviceID is computed from the BDF and some DMA alias. As the algorithm can't be tweaked, it's very likely that we will have non-contiguous Device ID. See
pci_for_each_dma_aliasin Linux (drivers/pci/search.c).
Quoted 7 lines
Quoted 3 lines
The implication here is that deviceID is fixed in hardware and is used by driver domain software in contexts where we do not get the opportunity to translate is that right? What contexts are those?
No, the driver domain software will always use a virtual DeviceID (based on the vBDF and other things). The problem I wanted to raise is how to translate back the vDeviceID to a physical deviceID/BDF.
Right, so this goes back to my original point, which is that if we completely control the translation from vDeviceID to pDeviceID/BDF then the vDeviceId space need not be sparse and need not utilise the entire 2^32 space, at least for domU uses.
Quoted 9 lines
Quoted 3 lines
Note that the BDF is also something which we could in principal virtualise (we already do for domU). Perhaps that is infeasible for dom0 though?
For DOM0 the virtual BDF is equal to the physical BDF. So the both deviceID (physical and virtual) will be the same.
We may decide to do vBDF == pBDF for guest too in order to simplify the code.
It seems to me that choosing vBDF such that the vDeviceId space is to our liking would be a good idea.
Quoted 9 lines
Quoted 7 lines
That gives me two thoughts.
The first is that although device identifiers are not necessarily contiguous, they are generally at least grouped and not allocated at random through the 2^32 options. For example a PCI Host bridge typically has a range of device ids associated with it and each device has a device id derived from that.
Usually it's one per (device, function).
Yes, but my point is that they are generally grouped by bus. The bus is assigned a (contiguous) range and individual (device,function)=> device id mappings are based on a formula applied to the base address.
i.e. for a given PCI bus the device ids are in the range 1000..1000+N, not N random number selected from the 2^32 space.
Quoted 11 lines
Quoted 10 lines
I'm not sure if we can leverage that into a more useful data structure than an R-B tree, or for example to arrange for the R-B to allow for the translation of a device within a span into the parent span and from there do the lookup. Specifically when looking up a device ID corresponding to a PCI device we could arrange to find the PCI host bridge and find the actual device from there. This would keep the RB tree much smaller and therefore perhaps quicker? Of course that depends on what the lookup from PCI host bridge to a device looked like.
Quoted 2 lines
I'm not sure why you are speaking about PCI host bridge. AFAIK, the guest doesn't have a physical host bridge.
It has a virtual one provided by the pciif/pcifront+back thing. Any PCI bus is behind some sort of host bridge, whether physical, virtual or "notional".
Quoted 30 lines
Although, this is an optimization that we can think about it later. The R-B will already be fast enough for a first implementation. My main point was about the translation vDeviceID => pDeviceID.
Quoted 26 lines
The second is that perhaps we can do something simpler for the domU case, if we were willing to tolerate it being different from dom0.
Quoted 23 lines
Quoted 21 lines
Possible efficient data structures would be:
1. List: The lookup/deletion is in O(n) and the insertion will depend if the device should be sorted following their identifier. The memory overhead is 18 bytes per element.
2. Red-black tree: All the operations are O(log(n)). The memory overhead is 24 bytes per element.A Red-black tree seems the more suitable for having fast deviceID validation even though the memory overhead is a bit higher compare to the list.
### Event ID (
vID)This is the per-device Interrupt identifier (i.e. the MSI index). It is configured by the device driver software.
It is not necessary to translate a
vID, however they may need to be represented in various data structures given to the pITS.XXX is any of this true?
Quoted 7 lines
Quoted 5 lines
Quoted 2 lines
Right, the vID will always be equal to the pID. Although you will need to associate a physical LPI for every pair (vID, DevID).
I think in the terms defined by this document that is (
ID,vID) => an LPI. Right?Well, by
IDyou refer about deviceID?
I think this section has suffered from multiple authors using inconsistent terminology and from some of the naming being confusingly similar. I'm going to do a pass and switch everything to consistently use the names used in the spec, with a p- or v- prefix as necessary.
Quoted 7 lines
Quoted 1 line
Have we considered how this mapping will be tracked?
I don't think so. We need to track the list of
event IDenabled for this deviceID and the associatedvLPIandLPI.Although, if allocate a contiguous chunck of
LPIit won't be necessary to track the later.
Is the deviceID space for a given device linear?
Quoted 26 lines
Quoted 26 lines
Quoted 9 lines
Quoted 9 lines
### Interrupt Collection (
vCID)This parameter is used in commands which manage collections and interrupt in order to move them for one CPU to another. The ITS is only mandated to implement N + 1 collections where N is the number of processor on the platform (i.e max number of VCPUs for a given guest). Furthermore, the identifiers are always contiguous.
Quoted 7 lines
Quoted 4 lines
If we decide to implement the strict minimum (i.e N + 1), an array is enough and will allow operations in O(1).
XXX Could forgo array and go straight to vcpu_info/domain_info.
Not really, the number of collection is always one higher than the number of VCPUs. How would you store the last collection?
In
domain_info. What I meant was:if ( vcid == domain->nr_vcpus ) return domain->interrupt_collection else if ( vcid < domain_nr_vcpus ) return domain->vcpus[vcid]->interrupt_colleciton else invalid vcid.
Quoted 6 lines
Quoted 1 line
Similar to how SPI vs PPI interrupts are handled.
Sorry, I didn't understand your suggestion like that.
I think that can work, although the resulting code may be difficult to read/understand because a collection can be moved from one vCPU to another.
Actually, I think the guest is allowed to point multiple collections at the same vcpu (it's dumb, but allowed), so this scheme probably doesn't work.
Quoted 15 lines
Quoted 15 lines
Quoted 15 lines
INVALL ensures that any interrupts in the specified collection are re-load. SYNC ensures that all the previous command, and all outstanding physical actions relating to the specified re-distributor are completed.
Quoted 8 lines
All other ITS command like
MOVI,DISCARD,INV,INT,CLEARjust validate and generate physical command.###
MAPCcommand translationFormat:
MAPC vCID, vTA-
MAPC pCID, pTAphysical ITS command is generated
Quoted 7 lines
Quoted 5 lines
Quoted 2 lines
We should not send any MAPC command to the physical ITS. The collection is already mapped during Xen boot.
What is the plan for this start of day mapping? One collection per pCPU and ignore the rest?
To map the only collection per pCPU. And we can see for improvement later.
If you are making assumptions like this which are not written down then please point out explicitly that an assumption needs to be documented.
Quoted 10 lines
Quoted 5 lines
Supposing that a guest is likely to use collections to map interrupts to specific vcpus, and that the physical collections will be mapped to pcpus, I suppose this means we will need to do some relatively expensive remapping (corresponding to moving the IRQ to another collection) in
arch_move_irqs? Is that the best we can do?If we use the same solution as SPI/PPIs (i.e
arch_move_irqs), yes. But I'm not in favor of this solution which is already expensive for SPI/PPIs (after talking with Dario, vCPU may move often between pCPU).
Quoted 7 lines
We could decide to implement a lazy solution (i.e moving the interrupt only when it's firing) but that would require to send ITS command in Xen.
Another idea is to never move the interrupt collection from one pCPU to another. The vCID would always be equal to the same pCID, but the interrupt would be injected to a different processor depending on the associated vTA.
I have an idea here, but I'm going to try and update the document for the current feedback before proposing a radical change.
Quoted 28 lines
Quoted 9 lines
Quoted 5 lines
I guess that if the OS is playing with the ITT (such as writing in it) the ITS will behave badly. We have to ensure to the guest will never write in it and by the same occasion that the same region is not passed to 2 devices.
I don't think we will be exposing the physical ITT to the guest, will we? That will live in memory which Xen owns and controls and doesn't share with any guest.
That's need to be clarify. The RFC sent by Vijay is letting the guest feeding the physical ITT.
But I just though that it won't work well, the ITT has to be contiguous in the physical memory.
Quoted 8 lines
In fact, I don't know that a vITS will need an ITT memory at all, i.e. most of our
GITS_BASERnwill be unimplemented.
In theory we could use these registers to offload some of the data structure storage requirements to the guest, but that would require great care to validate any time we touched it (or perhaps just p2m==r/o), I think it is probably not worth the stress if we can just use regular hypervisor side data structures instead? (This stuff is just there for the h/w ITS which doesn't have the luxury of xmalloc).
GITS_BASERnis only used to feed internal ITS table such as Collections, Devices, Virtual Processors.
Quoted 7 lines
For the ITT, the address is passed via MAPD and as to be allocated by the guest.
We could ignore the address provided by the guest but that would mean the ITT is allocated twice (one by the guest unused, and the Xen one used to feed the pITS). Although, as pointed above the ITT memory region allocated by the guest may not be contiguous in physical memory
There is absolutely no way that we are going to be giving guest controlled memory to the pITS. We absolutely have to allocate and use Xen memory for the pITT.
The vITT needs to be "shadowed" into the pITT after translation and verification.
Quoted 4 lines
Furthermore, if we allocate the ITT in Xen, this command will be quick to emulate (we could send the MAPD command when the device is attached).
So less possible security issue.
Far less, yes.
Quoted 8 lines
Quoted 8 lines
Quoted 7 lines
Quoted 4 lines
Here the overhead is with memory allocation for
its_deviceandvlpi_mapXXX Suggestion was to preallocate some of those at device passthrough setup time?
Some of the informations can even be setup when the PCI device is added to Xen (such as the number of MSI supported and physical LPIs chunk).
Quoted 8 lines
Quoted 2 lines
Yes, assuming there are sufficient LPIs to allocate in this way. That's not clear though, is it?
IHMO it's not an issue. If the ITS doesn't provide enough LPIs a baremetal OS will likely not being able to use a device.
FWIW, Linux is always allocating the LPIs when the device is added based on the PCI cfg.
The sort of thing I'm worried about is a device (i.e. some off the shelf IP) with some number of MSIs supported integrated in a device where, for whatever reason, the designer has decided that only a smaller set of MSIs are worth supporting and sizing the ITS accordingly (i.e. deciding to only support 8 queues in a NIC instead of the full 16).
In such a decide the sum(all devices MSIs) > num LPIs.
Maybe we can defer worrying about this till later.
Quoted 23 lines
Quoted 14 lines
Quoted 14 lines
Quoted 10 lines
- Allocate irq descriptor and add to RB tree
- callroute_irq_to_guest()for this pID
- Generate/format physical ITS command:MAPVI device ID, pID, pCIDHere the overhead is allocating physical ID, allocate memory for irq descriptor and routing interrupt.
XXX Suggested to preallocate?
Right. We may also need to have a separate routing for LPIs as the current function is quite long to execute.
Quoted 6 lines
Quoted 3 lines
I was thinking into routing the interrupt at device assignation (assuming we allocate the pLPIs at that time). And only set the mapping to vLPIs when the MAPI is called.
Please propose concrete modifications to the text, since I can't figure out what you mean to change here.
It's not yet fully clear in my mind.
Quoted 8 lines
If we assuming that we have a chunk of LPIs allocate for a the device when it's assigned to the guest, the only missing information is the corresponding vLPIs.
We could decide to setup the internal routing structure (allocation of the
irq_guest) and defer the setting of the vLPI. This would work because the interrupt are disabled at boot time and won't be enabled as long as a MAPVI command is sent.
I'm going to try and write some introductory bits about these data structures and early allocations to try and bring some clarity here so we can decide what to actually do.
Quoted 9 lines
Quoted 9 lines
Quoted 9 lines
Quoted 1 line
###
INVALLCommand translationThe format of INVALL is INVALL collection
Quoted 4 lines
A physical
INVALLis only generated if the LPI dirty bitmap has any bits set. Otherwise it is skipped.XXX Perhaps bitmap should just be a simple counter?
Quoted 8 lines
Quoted 5 lines
Quoted 1 line
We would need to handle it per collection.
Hrm, this complicates things a bit. Don't we need to invalidate any pCID which has a routing of an interrupt to vCID? i.e. potentially multiple INVALL?
Not necessarily. If we keep the interrupts of a vCID always in the same pCID, we would need to send only on INVALL.
I think I/we need to spec out the vCID->pCID mapping a bit more clearly so we can see how this will fit together.
Ian.