iio: humidty: add HDC100x support
v2 cover iio: humidty: add HDC100x support
Changes from v2:
* Fixed incorrect byte order from measurement reading
* Updated Kconfig and ABI documentation
* Changed resolution data to more readable struct
* Removed un-needed .channel assignments in hdc100x_channels
* Fixed logic bug in heater enabling
* Various minor changes (removing inlines, removing fall-thrus, etc)
Matt Ranostay (1):
iio: humidity: add HDC100x support
.../ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 + drivers/iio/humidity/Kconfig | 10 + drivers/iio/humidity/Makefile | 1 + drivers/iio/humidity/hdc100x.c | 317 +++++++++++++++++++++ 4 files changed, 337 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x create mode 100644 drivers/iio/humidity/hdc100x.c
Signature · 1 line
1.9.1
PATCH v2 1/1 iio: humidity: add HDC100x support
Add support for the HDC100x temperature and humidity sensors including the resistive heater element.
--- .../ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 + drivers/iio/humidity/Kconfig | 10 + drivers/iio/humidity/Makefile | 1 + drivers/iio/humidity/hdc100x.c | 317 +++++++++++++++++++++ 4 files changed, 337 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x create mode 100644 drivers/iio/humidity/hdc100x.c
Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +9 -0
@@ -0,0 +1,9 @@ +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available +KernelVersion: 4.2 +Contact: [email protected] +Description: + Controls the heater device within the humidity sensor to get + rid of excess condensation. + + Valid control values are 0 = OFF, and 1 = ON.
drivers/iio/humidity/Kconfig +10 -0
@@ -12,6 +12,16 @@ config DHT11 Other sensors should work as well as long as they speak the same protocol. +config HDC100X + tristate "TI HDC100x relative humidity and temperature sensor" + depends on I2C + help + Say yes here to build support for the TI HDC100x series of + relative humidity and temperature sensors. + + To compile this driver as a module, choose M here: the module + will be called hdc100x. + config SI7005 tristate "SI7005 relative humidity and temperature sensor" depends on I2C
drivers/iio/humidity/Makefile +1 -0
@@ -3,5 +3,6 @@ # obj-$(CONFIG_DHT11) += dht11.o +obj-$(CONFIG_HDC100X) += hdc100x.o obj-$(CONFIG_SI7005) += si7005.o obj-$(CONFIG_SI7020) += si7020.o
drivers/iio/humidity/hdc100x.c new file +317 -0
317 lines not on this page · raw message
Signature · 1 line
1.9.1
Re: [PATCH v2 1/1] iio: humidity: add HDC100x support
Quoted 2 lines · Matt Ranostay
Add support for the HDC100x temperature and humidity sensors including the resistive heater element.
some more comments inline
Quoted 16 lines
Signed-off-by Matt Ranostay <[email protected]>--- .../ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 + drivers/iio/humidity/Kconfig | 10 + drivers/iio/humidity/Makefile | 1 + drivers/iio/humidity/hdc100x.c | 317 +++++++++++++++++++++ 4 files changed, 337 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x create mode 100644 drivers/iio/humidity/hdc100x.cDocumentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +0
-0
Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x line 3
Quoted 3 lines
Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +3
-0@@ -0,0 +1,9 @@ +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available +KernelVersion: 4.2
4.3 probably
Quoted 132 lines
Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +6
-0+Contact: [email protected] +Description: + Controls the heater device within the humidity sensor to get + rid of excess condensation. + + Valid control values are 0 = OFF, and 1 = ON.drivers/iio/humidity/Kconfig +10
-0@@ -12,6 +12,16 @@ config DHT11 Other sensors should work as well as long as they speak the same protocol. +config HDC100X + tristate "TI HDC100x relative humidity and temperature sensor" + depends on I2C + help + Say yes here to build support for the TI HDC100x series of + relative humidity and temperature sensors. + + To compile this driver as a module, choose M here: the module + will be called hdc100x. + config SI7005 tristate "SI7005 relative humidity and temperature sensor" depends on I2Cdrivers/iio/humidity/Makefile +1
-0@@ -3,5 +3,6 @@ # obj-$(CONFIG_DHT11) += dht11.o +obj-$(CONFIG_HDC100X) += hdc100x.o obj-$(CONFIG_SI7005) += si7005.o obj-$(CONFIG_SI7020) += si7020.odrivers/iio/humidity/hdc100x.c new file +88
-0@@ -0,0 +1,317 @@ +/* +* hdc100x.c - Support for the TI HDC100x temperature + humidity sensors +* +* Copyright (C) 2015 Matt Ranostay <[email protected]> +* +* This program is free software; you can redistribute it and/or modify +* it under the terms of the GNU General Public License as published by +* the Free Software Foundation; either version 2 of the License, or +* (at your option) any later version. +* +* This program is distributed in the hope that it will be useful, +* but WITHOUT ANY WARRANTY; without even the implied warranty of +* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the +* GNU General Public License for more details. +* +*/ + +#include <linux/delay.h> +#include <linux/module.h> +#include <linux/init.h> +#include <linux/i2c.h> + +#include <linux/iio/iio.h> +#include <linux/iio/sysfs.h> + +#define HDC100X_REG_TEMP 0x00 +#define HDC100X_REG_HUMIDITY 0x01 + +#define HDC100X_REG_CONFIG 0x02 +#define HDC100X_REG_CONFIG_HEATER_EN BIT(13) + +struct hdc100x_data { +struct i2c_client *client; +struct mutex lock; +u16 config; + +/* integration time of the sensor */ +int adc_int_us[2 ]; +}; + +/* integration time in us */ +static const int hdc100x_int_time[][3 ] = { + {6350 ,3650 ,0 },/* IIO_TEMP channel*/ + {6500 ,3850 ,2500 },/* IIO_HUMIDITYRELATIVE channel */ +}; + +/* HDC100X_REG_CONFIG shift and mask values */ +static const struct { +int shift; +int mask; +} hdc100x_resolution_shift[2 ] = { + {/* IIO_TEMP channel */ + .shift =10 , + .mask =1 + }, + {/* IIO_HUMIDITYRELATIVE channel */ + .shift =8 , + .mask =2 , + }, +}; + +static IIO_CONST_ATTR(temp_integration_time_available, + "0.00365 0.00635"); + +static IIO_CONST_ATTR(humidityrelative_integration_time_available, + "0.0025 0.00385 0.0065"); + +static IIO_CONST_ATTR(out_current_heater_raw_available, + "0 1"); + +static struct attribute *hdc100x_attributes[] = { + &iio_const_attr_temp_integration_time_available.dev_attr.attr, + &iio_const_attr_humidityrelative_integration_time_available.dev_attr.attr, + &iio_const_attr_out_current_heater_raw_available.dev_attr.attr, +NULL +}; + +static struct attribute_group hdc100x_attribute_group = { + .attrs = hdc100x_attributes, +}; + +static const struct iio_chan_spec hdc100x_channels[] = { + { + .type =IIO_TEMP , + .address =HDC100X_REG_TEMP , + .info_mask_separate =BIT (IIO_CHAN_INFO_RAW ) | +BIT (IIO_CHAN_INFO_SCALE ) | + BIT(IIO_CHAN_INFO_INT_TIME) |
drivers/iio/humidity/hdc100x.c line 98
Quoted 10 lines
drivers/iio/humidity/hdc100x.c new file +10
-0+ BIT(IIO_CHAN_INFO_OFFSET), + }, + { + .type = IIO_HUMIDITYRELATIVE, + .address = HDC100X_REG_HUMIDITY, + .info_mask_separate =BIT (IIO_CHAN_INFO_RAW ) | +BIT (IIO_CHAN_INFO_SCALE ) | +BIT (IIO_CHAN_INFO_INT_TIME ) + }, +
drop newline
Quoted 22 lines
drivers/iio/humidity/hdc100x.c new file +22
-0+ { + .type = IIO_CURRENT, + .info_mask_separate = BIT(IIO_CHAN_INFO_RAW), + .extend_name = "heater", + .output = 1, + }, +}; + +static int hdc100x_update_config (struct hdc100x_data *data,int mask,int val) +{ +int tmp = (~mask & data->config) | val; +int ret; + + ret =i2c_smbus_write_word_swapped (data->client, +HDC100X_REG_CONFIG , tmp); +if (!ret) + data->config = tmp; + +return ret; +} + +static int hdc100x_set_it_time (struct hdc100x_data *data,int chan,int val2)
drivers/iio/humidity/hdc100x.c line 130
Quoted 10 lines
drivers/iio/humidity/hdc100x.c new file +10
-0+{ +int shift = hdc100x_resolution_shift[chan].shift; +int ret = -EINVAL ; +int i; + +for (i =0 ; i <ARRAY_SIZE (hdc100x_int_time[chan]); i++) { +if (val2 && val2 == hdc100x_int_time[chan][i]) { + ret =hdc100x_update_config (data, + hdc100x_resolution_shift[chan].mask << shift, + i << shift);
strictly, should only update adc_int_us if succssful
Quoted 54 lines
drivers/iio/humidity/hdc100x.c new file +54
-0+ data->adc_int_us[chan] = val2; +break ; + } + } + +return ret; +} + +static int hdc100x_get_measurement (struct hdc100x_data *data, +struct iio_chan_spec const *chan) +{ +struct i2c_client *client = data->client; +int delay = data->adc_int_us[chan->address]; +int ret; +int val; + +/* start measurement */ + ret =i2c_smbus_write_byte (client, chan->address); +if (ret <0 ) { +dev_err (&client->dev,"cannot start measurement" ); +return ret; + } + +/* wait for integration time to pass */ +usleep_range (delay, delay +1000 ); + + ret =i2c_smbus_read_byte (client); +if (ret <0 ) { +dev_err (&client->dev,"cannot read high byte measurement" ); +return ret; + } + val = ret <<6 ; + + ret =i2c_smbus_read_byte (client); +if (ret <0 ) { +dev_err (&client->dev,"cannot read low byte measurement" ); +return ret; + } + val |= ret >>2 ; + +return val; +} + +static int hdc100x_get_heater_status (struct hdc100x_data *data) +{ +return !!(data->config &HDC100X_REG_CONFIG_HEATER_EN ); +} + +static int hdc100x_read_raw (struct iio_dev *indio_dev, +struct iio_chan_spec const *chan,int *val, +int *val2,long mask) +{ +struct hdc100x_data *data =iio_priv (indio_dev); +int ret = -EINVAL ;
drivers/iio/humidity/hdc100x.c line 194
Quoted 10 lines
drivers/iio/humidity/hdc100x.c new file +10
-0+ +switch (mask) { +case IIO_CHAN_INFO_RAW : +mutex_lock (&data->lock); +if (chan->type ==IIO_CURRENT ) { + *val =hdc100x_get_heater_status (data); + ret =IIO_VAL_INT ; + }else { + ret =hdc100x_get_measurement (data, chan); +if (ret >0 ) {
what if the measurement is 0?
drivers/iio/humidity/hdc100x.c line 205
Quoted 11 lines
drivers/iio/humidity/hdc100x.c new file +11
-0+ *val = ret; + ret =IIO_VAL_INT ; + } + } +mutex_unlock (&data->lock); +break ; +case IIO_CHAN_INFO_INT_TIME : + *val =0 ; + *val2 = data->adc_int_us[chan->address]; +return IIO_VAL_INT_PLUS_MICRO ; +case IIO_CHAN_INFO_SCALE :
the scaling does not change depending on INT_TIME?
Quoted 113 lines
drivers/iio/humidity/hdc100x.c new file +112
-0+if (chan->type ==IIO_TEMP ) { + *val =165 ; + *val2 =65536 >>2 ; + ret =IIO_VAL_FRACTIONAL ; + }else { + *val =0 ; + *val2 =10000 ; + ret =IIO_VAL_INT_PLUS_MICRO ; + } +break ; +case IIO_CHAN_INFO_OFFSET : + *val =-40 ; +return IIO_VAL_INT ; +default : +break ; + } + +return ret; +} + +static int hdc100x_write_raw (struct iio_dev *indio_dev, +struct iio_chan_spec const *chan, +int val,int val2,long mask) +{ +struct hdc100x_data *data =iio_priv (indio_dev); +int ret = -EINVAL ; + +switch (mask) { +case IIO_CHAN_INFO_INT_TIME : +if (val !=0 ) +return -EINVAL ; + +mutex_lock (&data->lock); + ret =hdc100x_set_it_time (data, chan->address, val2); +mutex_unlock (&data->lock); +break ; +case IIO_CHAN_INFO_RAW : +if (chan->type ==IIO_CURRENT ) { +if (val2 !=0 ) +return -EINVAL ; + +mutex_lock (&data->lock); + ret =hdc100x_update_config (data, +HDC100X_REG_CONFIG_HEATER_EN , + val ?HDC100X_REG_CONFIG_HEATER_EN :0 ); +mutex_unlock (&data->lock); + } +return ret; + } + +return ret; +} + +static const struct iio_info hdc100x_info = { + .read_raw = hdc100x_read_raw, + .write_raw = hdc100x_write_raw, + .attrs = &hdc100x_attribute_group, + .driver_module =THIS_MODULE , +}; + +static int hdc100x_probe (struct i2c_client *client, +const struct i2c_device_id *id) +{ +struct iio_dev *indio_dev; +struct hdc100x_data *data; + +if (!i2c_check_functionality (client->adapter, +I2C_FUNC_SMBUS_WORD_DATA |I2C_FUNC_SMBUS_BYTE )) +return -ENODEV ; + + indio_dev =devm_iio_device_alloc (&client->dev,sizeof (*data)); +if (!indio_dev) +return -ENOMEM ; + + data =iio_priv (indio_dev); +i2c_set_clientdata (client, indio_dev); + data->client = client; +mutex_init (&data->lock); + + indio_dev->dev.parent = &client->dev; + indio_dev->name =dev_name (&client->dev); + indio_dev->modes =INDIO_DIRECT_MODE ; + indio_dev->info = &hdc100x_info; + + indio_dev->channels = hdc100x_channels; + indio_dev->num_channels =ARRAY_SIZE (hdc100x_channels); + +/* be sure we are in a known state */ +hdc100x_set_it_time (data,0 , hdc100x_int_time[0 ][0 ]); +hdc100x_set_it_time (data,1 , hdc100x_int_time[1 ][0 ]); + +return devm_iio_device_register (&client->dev, indio_dev); +} + +static const struct i2c_device_id hdc100x_id[] = { + {"hdc100x" ,0 }, + { } +}; +MODULE_DEVICE_TABLE (i2c, hdc100x_id); + +static struct i2c_driver hdc100x_driver = { + .driver = { + .name ="hdc100x" , + }, + .probe = hdc100x_probe, + .id_table = hdc100x_id, +}; +module_i2c_driver (hdc100x_driver); + +MODULE_AUTHOR ("Matt Ranostay <[email protected]>" ); +MODULE_DESCRIPTION ("TI HDC100x humidity and temperature sensor driver" ); +MODULE_LICENSE ("GPL" );
Signature · 2 lines
Peter Meerwald +43-664-2444418 (mobile)
Re: [PATCH v2 1/1] iio: humidity: add HDC100x support
Quoted 200 lines · Peter Meerwald
Quoted 2 lines · Matt Ranostay
Add support for the HDC100x temperature and humidity sensors including the resistive heater element.
some more comments inline
Quoted 16 lines
Signed-off-by Matt Ranostay <[email protected]>--- .../ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 + drivers/iio/humidity/Kconfig | 10 + drivers/iio/humidity/Makefile | 1 + drivers/iio/humidity/hdc100x.c | 317 +++++++++++++++++++++ 4 files changed, 337 insertions(+) create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x create mode 100644 drivers/iio/humidity/hdc100x.cDocumentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +0
-0Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x line 3
Quoted 3 lines
Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +3
-0@@ -0,0 +1,9 @@ +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw +What: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available +KernelVersion: 4.24.3 probably
Quoted 132 lines
Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x new file +6
-0+Contact: [email protected] +Description: + Controls the heater device within the humidity sensor to get + rid of excess condensation. + + Valid control values are 0 = OFF, and 1 = ON.drivers/iio/humidity/Kconfig +10
-0@@ -12,6 +12,16 @@ config DHT11 Other sensors should work as well as long as they speak the same protocol. +config HDC100X + tristate "TI HDC100x relative humidity and temperature sensor" + depends on I2C + help + Say yes here to build support for the TI HDC100x series of + relative humidity and temperature sensors. + + To compile this driver as a module, choose M here: the module + will be called hdc100x. + config SI7005 tristate "SI7005 relative humidity and temperature sensor" depends on I2Cdrivers/iio/humidity/Makefile +1
-0@@ -3,5 +3,6 @@ # obj-$(CONFIG_DHT11) += dht11.o +obj-$(CONFIG_HDC100X) += hdc100x.o obj-$(CONFIG_SI7005) += si7005.o obj-$(CONFIG_SI7020) += si7020.odrivers/iio/humidity/hdc100x.c new file +88
-0@@ -0,0 +1,317 @@ +/* +* hdc100x.c - Support for the TI HDC100x temperature + humidity sensors +* +* Copyright (C) 2015 Matt Ranostay <[email protected]> +* +* This program is free software; you can redistribute it and/or modify +* it under the terms of the GNU General Public License as published by +* the Free Software Foundation; either version 2 of the License, or +* (at your option) any later version. +* +* This program is distributed in the hope that it will be useful, +* but WITHOUT ANY WARRANTY; without even the implied warranty of +* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the +* GNU General Public License for more details. +* +*/ + +#include <linux/delay.h> +#include <linux/module.h> +#include <linux/init.h> +#include <linux/i2c.h> + +#include <linux/iio/iio.h> +#include <linux/iio/sysfs.h> + +#define HDC100X_REG_TEMP 0x00 +#define HDC100X_REG_HUMIDITY 0x01 + +#define HDC100X_REG_CONFIG 0x02 +#define HDC100X_REG_CONFIG_HEATER_EN BIT(13) + +struct hdc100x_data { +struct i2c_client *client; +struct mutex lock; +u16 config; + +/* integration time of the sensor */ +int adc_int_us[2 ]; +}; + +/* integration time in us */ +static const int hdc100x_int_time[][3 ] = { + {6350 ,3650 ,0 },/* IIO_TEMP channel*/ + {6500 ,3850 ,2500 },/* IIO_HUMIDITYRELATIVE channel */ +}; + +/* HDC100X_REG_CONFIG shift and mask values */ +static const struct { +int shift; +int mask; +} hdc100x_resolution_shift[2 ] = { + {/* IIO_TEMP channel */ + .shift =10 , + .mask =1 + }, + {/* IIO_HUMIDITYRELATIVE channel */ + .shift =8 , + .mask =2 , + }, +}; + +static IIO_CONST_ATTR(temp_integration_time_available, + "0.00365 0.00635"); + +static IIO_CONST_ATTR(humidityrelative_integration_time_available, + "0.0025 0.00385 0.0065"); + +static IIO_CONST_ATTR(out_current_heater_raw_available, + "0 1"); + +static struct attribute *hdc100x_attributes[] = { + &iio_const_attr_temp_integration_time_available.dev_attr.attr, + &iio_const_attr_humidityrelative_integration_time_available.dev_attr.attr, + &iio_const_attr_out_current_heater_raw_available.dev_attr.attr, +NULL +}; + +static struct attribute_group hdc100x_attribute_group = { + .attrs = hdc100x_attributes, +}; + +static const struct iio_chan_spec hdc100x_channels[] = { + { + .type =IIO_TEMP , + .address =HDC100X_REG_TEMP , + .info_mask_separate =BIT (IIO_CHAN_INFO_RAW ) | +BIT (IIO_CHAN_INFO_SCALE ) | + BIT(IIO_CHAN_INFO_INT_TIME) |drivers/iio/humidity/hdc100x.c line 98
Quoted 10 lines
drivers/iio/humidity/hdc100x.c new file +10
-0+ BIT(IIO_CHAN_INFO_OFFSET), + }, + { + .type = IIO_HUMIDITYRELATIVE, + .address = HDC100X_REG_HUMIDITY, + .info_mask_separate =BIT (IIO_CHAN_INFO_RAW ) | +BIT (IIO_CHAN_INFO_SCALE ) | +BIT (IIO_CHAN_INFO_INT_TIME ) + }, +drop newline
Quoted 26 lines
drivers/iio/humidity/hdc100x.c new file +26
-0+ { + .type = IIO_CURRENT, + .info_mask_separate = BIT(IIO_CHAN_INFO_RAW), + .extend_name = "heater", + .output = 1, + }, +}; + +static int hdc100x_update_config (struct hdc100x_data *data,int mask,int val) +{ +int tmp = (~mask & data->config) | val; +int ret; + + ret =i2c_smbus_write_word_swapped (data->client, +HDC100X_REG_CONFIG , tmp); +if (!ret) + data->config = tmp; + +return ret; +} + +static int hdc100x_set_it_time (struct hdc100x_data *data,int chan,int val2) +{ +int shift = hdc100x_resolution_shift[chan].shift; +int ret = -EINVAL ; +int i;
Quoted 8 lines
drivers/iio/humidity/hdc100x.c line 130
Quoted 6 lines
drivers/iio/humidity/hdc100x.c new file +6
-0+ +for (i =0 ; i <ARRAY_SIZE (hdc100x_int_time[chan]); i++) { +if (val2 && val2 == hdc100x_int_time[chan][i]) { + ret =hdc100x_update_config (data, + hdc100x_resolution_shift[chan].mask << shift, + i << shift);strictly, should only update
adc_int_usif succssful
Will fix in v3
Quoted 59 lines
Quoted 59 lines
drivers/iio/humidity/hdc100x.c new file +58
-0+ data->adc_int_us[chan] = val2; +break ; + } + } + +return ret; +} + +static int hdc100x_get_measurement (struct hdc100x_data *data, +struct iio_chan_spec const *chan) +{ +struct i2c_client *client = data->client; +int delay = data->adc_int_us[chan->address]; +int ret; +int val; + +/* start measurement */ + ret =i2c_smbus_write_byte (client, chan->address); +if (ret <0 ) { +dev_err (&client->dev,"cannot start measurement" ); +return ret; + } + +/* wait for integration time to pass */ +usleep_range (delay, delay +1000 ); + + ret =i2c_smbus_read_byte (client); +if (ret <0 ) { +dev_err (&client->dev,"cannot read high byte measurement" ); +return ret; + } + val = ret <<6 ; + + ret =i2c_smbus_read_byte (client); +if (ret <0 ) { +dev_err (&client->dev,"cannot read low byte measurement" ); +return ret; + } + val |= ret >>2 ; + +return val; +} + +static int hdc100x_get_heater_status (struct hdc100x_data *data) +{ +return !!(data->config &HDC100X_REG_CONFIG_HEATER_EN ); +} + +static int hdc100x_read_raw (struct iio_dev *indio_dev, +struct iio_chan_spec const *chan,int *val, +int *val2,long mask) +{ +struct hdc100x_data *data =iio_priv (indio_dev); +int ret = -EINVAL ; + +switch (mask) { +case IIO_CHAN_INFO_RAW : +mutex_lock (&data->lock);
Quoted 8 lines
drivers/iio/humidity/hdc100x.c line 194
Quoted 6 lines
drivers/iio/humidity/hdc100x.c new file +6
-0+if (chan->type ==IIO_CURRENT ) { + *val =hdc100x_get_heater_status (data); + ret =IIO_VAL_INT ; + }else { + ret =hdc100x_get_measurement (data, chan); +if (ret >0 ) {what if the measurement is 0?
Ah yes that is possible... albeit pretty cold.
Will fix in v3
Quoted 13 lines
drivers/iio/humidity/hdc100x.c line 205
Quoted 12 lines
drivers/iio/humidity/hdc100x.c new file +11
-0+ *val = ret; + ret =IIO_VAL_INT ; + } + } +mutex_unlock (&data->lock); +break ; +case IIO_CHAN_INFO_INT_TIME : + *val =0 ; + *val2 = data->adc_int_us[chan->address]; +return IIO_VAL_INT_PLUS_MICRO ; +case IIO_CHAN_INFO_SCALE :
Quoted 1 line
the scaling does not change depending on
INT_TIME?
Actually no... resolution changes (8, 11, 14) but the value reported back from sensor is always 14 bits per the datasheet...
Quoted 119 lines
Quoted 104 lines
drivers/iio/humidity/hdc100x.c new file +102
-0+if (chan->type ==IIO_TEMP ) { + *val =165 ; + *val2 =65536 >>2 ; + ret =IIO_VAL_FRACTIONAL ; + }else { + *val =0 ; + *val2 =10000 ; + ret =IIO_VAL_INT_PLUS_MICRO ; + } +break ; +case IIO_CHAN_INFO_OFFSET : + *val =-40 ; +return IIO_VAL_INT ; +default : +break ; + } + +return ret; +} + +static int hdc100x_write_raw (struct iio_dev *indio_dev, +struct iio_chan_spec const *chan, +int val,int val2,long mask) +{ +struct hdc100x_data *data =iio_priv (indio_dev); +int ret = -EINVAL ; + +switch (mask) { +case IIO_CHAN_INFO_INT_TIME : +if (val !=0 ) +return -EINVAL ; + +mutex_lock (&data->lock); + ret =hdc100x_set_it_time (data, chan->address, val2); +mutex_unlock (&data->lock); +break ; +case IIO_CHAN_INFO_RAW : +if (chan->type ==IIO_CURRENT ) { +if (val2 !=0 ) +return -EINVAL ; + +mutex_lock (&data->lock); + ret =hdc100x_update_config (data, +HDC100X_REG_CONFIG_HEATER_EN , + val ?HDC100X_REG_CONFIG_HEATER_EN :0 ); +mutex_unlock (&data->lock); + } +return ret; + } + +return ret; +} + +static const struct iio_info hdc100x_info = { + .read_raw = hdc100x_read_raw, + .write_raw = hdc100x_write_raw, + .attrs = &hdc100x_attribute_group, + .driver_module =THIS_MODULE , +}; + +static int hdc100x_probe (struct i2c_client *client, +const struct i2c_device_id *id) +{ +struct iio_dev *indio_dev; +struct hdc100x_data *data; + +if (!i2c_check_functionality (client->adapter, +I2C_FUNC_SMBUS_WORD_DATA |I2C_FUNC_SMBUS_BYTE )) +return -ENODEV ; + + indio_dev =devm_iio_device_alloc (&client->dev,sizeof (*data)); +if (!indio_dev) +return -ENOMEM ; + + data =iio_priv (indio_dev); +i2c_set_clientdata (client, indio_dev); + data->client = client; +mutex_init (&data->lock); + + indio_dev->dev.parent = &client->dev; + indio_dev->name =dev_name (&client->dev); + indio_dev->modes =INDIO_DIRECT_MODE ; + indio_dev->info = &hdc100x_info; + + indio_dev->channels = hdc100x_channels; + indio_dev->num_channels =ARRAY_SIZE (hdc100x_channels); + +/* be sure we are in a known state */ +hdc100x_set_it_time (data,0 , hdc100x_int_time[0 ][0 ]); +hdc100x_set_it_time (data,1 , hdc100x_int_time[1 ][0 ]); + +return devm_iio_device_register (&client->dev, indio_dev); +} + +static const struct i2c_device_id hdc100x_id[] = { + {"hdc100x" ,0 }, + { } +}; +MODULE_DEVICE_TABLE (i2c, hdc100x_id); + +static struct i2c_driver hdc100x_driver = { + .driver = {drivers/iio/humidity/hdc100x.c line 317
Quoted 10 lines
drivers/iio/humidity/hdc100x.c new file +10
-0+ .name = "hdc100x", + }, + .probe = hdc100x_probe, + .id_table = hdc100x_id, +}; +module_i2c_driver (hdc100x_driver); + +MODULE_AUTHOR ("Matt Ranostay <[email protected]>" ); +MODULE_DESCRIPTION ("TI HDC100x humidity and temperature sensor driver" ); +MODULE_LICENSE ("GPL" );--
Peter Meerwald