PL061 device state cleaning
v3 cover PL061 device state cleaning
Current QEMU doesn't reset PL061 device state. As a result the device keeps a stale state after guest reboots. This causes VM fail to recceive GPIO commands (e.g. virsh shutdown/reoot commands) after reboot. This patchset adds reset support for PL061 devices. The second patch removes an unused field.
V3:
* hook up dc->reset to existing reset function. And stop calling reset in initfn()
* add Reviewed-by
V2:
* derived from V1 after further debug. Now it resets device state instead of using pulse for GPIO IRQ.
V1:
* initial patch
-Wei
Wei Huang (2):
ARM: PL061: Clear PL061 device state after reset
ARM: PL061: Cleaning field of PL061 device state
hw/gpio/pl061.c | 37 +++++++++++++++++++++++++++++-------- 1 file changed, 29 insertions(+), 8 deletions(-)
Signature · 1 line
1.8.3.1
PATCH v3 1/2 ARM: PL061: Clear PL061 device state after reset
Current QEMU doesn't clear PL061 state after reset. This causes a weird issue with guest reboot via GPIO. Here is the device state with two reboot requests:
(PL061State fields) data old_in_data istate VM boot 0 0 0 After 1st ACPI reboot request 8 8 8 After VM PL061 driver ACK 8 8 0 After VM reboot 8 8 0
------------------------------------------------------------
2nd ACPI reboot request 8
In the second reboot request above, because the old_in_data field is 8, QEMU decides that there is a pending edge IRQ already (see pl061_update()) in input; so it doesn't raise up IRQ again. As a result the second reboot request is lost. The correct way is to clear PL061 device state after reset.
The default reset state is found from the documents listed below. Per Peter's suggestion that QEMU automatically calls reset function after device initialization, this patch removes calling pl061_reset() from pl061_initfn().
Reference:
[1] PL061 Technical Reference Manual
[2] Stellaris LM3S8962 Microcontroller Data Sheet
[3] Stellaris LM3S5P31 Microcontroller Data Sheet
--- hw/gpio/pl061.c | 31 +++++++++++++++++++++++++++---- 1 file changed, 27 insertions(+), 4 deletions(-)
hw/gpio/pl061.c +27 -4
@@ -282,10 +282,32 @@ static void pl061_write(void *opaque, hwaddr offset,pl061_update (s); } -static void pl061_reset (PL061State *s) +static void pl061_reset (DeviceState *dev) { - s->locked =1 ; - s->cr =0xff ; +PL061State *s =PL061 (dev); + +/* reset values from PL061 TRM, Stellaris LM3S5P31 & LM3S8962 Data Sheet */ + s->data =0 ; + s->old_out_data =0 ; + s->old_in_data =0 ; + s->dir =0 ; + s->isense =0 ; + s->ibe =0 ; + s->iev =0 ; + s->im =0 ; + s->istate =0 ; + s->afsel =0 ; + s->dr2r =0xff ; + s->dr4r =0 ; + s->dr8r =0 ; + s->odr =0 ; + s->pur =0 ; + s->pdr =0 ; + s->slr =0 ; + s->den =0 ; + s->locked =1 ; + s->cr =0xff ; + s->amsel =0 ; }static void pl061_set_irq (void * opaque,int irq,int level)
@@ -318,7 +340,7 @@ static int pl061_initfn(SysBusDevice *sbd)sysbus_init_irq (sbd, &s->irq);qdev_init_gpio_in (dev, pl061_set_irq,8 );qdev_init_gpio_out (dev, s->out,8 ); -pl061_reset (s); +return 0 ; }
@@ -343,6 +365,7 @@ static void pl061_class_init(ObjectClass *klass, void *data) k->init = pl061_initfn; dc->vmsd = &vmstate_pl061; + dc->reset = &pl061_reset; }static const TypeInfo pl061_info = {
Signature · 1 line
1.8.3.1
PATCH v3 2/2 ARM: PL061: Cleaning field of PL061 device state
In reply to Wei HuangThis patch removes the float_high field of PL061State, which doesn't seem to be used anywhere. Because this changes the device state, the version ID is also bumped up for the reason of compatiblity.
--- hw/gpio/pl061.c | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-)
hw/gpio/pl061.c +2 -4
@@ -56,7 +56,6 @@ typedef struct PL061State {uint32_t slr;uint32_t den;uint32_t cr; -uint32_t float_high;uint32_t amsel;qemu_irq irq;qemu_irq out[8 ];
@@ -65,8 +64,8 @@ typedef struct PL061State {static const VMStateDescription vmstate_pl061 = { .name ="pl061" , - .version_id =3 , - .minimum_version_id =3 , + .version_id =4 , + .minimum_version_id =4 , .fields = (VMStateField []) {VMSTATE_UINT32 (locked, PL061State),VMSTATE_UINT32 (data, PL061State),
@@ -88,7 +87,6 @@ static const VMStateDescription vmstate_pl061 = {VMSTATE_UINT32 (slr, PL061State),VMSTATE_UINT32 (den, PL061State),VMSTATE_UINT32 (cr, PL061State), -VMSTATE_UINT32 (float_high, PL061State),VMSTATE_UINT32_V (amsel, PL061State,2 ), VMSTATE_END_OF_LIST() }
Signature · 1 line
1.8.3.1
Peter Maydell
AppliedQuoted 5 lines · Wei Huang
Current QEMU doesn't reset PL061 device state. As a result the device keeps a stale state after guest reboots. This causes VM fail to recceive GPIO commands (e.g. virsh shutdown/reoot commands) after reboot. This patchset adds reset support for PL061 devices. The second patch removes an unused field.
Applied to target-arm.next, thanks.
-- PMM