iio: hudmidity: hdc100x: fix incorrect shifting and scaling
PATCH 1/1 iio: hudmidity: hdc100x: fix incorrect shifting and scaling
Shifting sensor data to the right 2 bits was incorrect and caused the scaling values + offsets to be invalid.
--- drivers/iio/humidity/hdc100x.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-)
drivers/iio/humidity/hdc100x.c +8 -8
@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct hdc100x_data *data,dev_err (&client->dev,"cannot read high byte measurement" );return ret; } - val = ret <<6 ; + val = ret <<8 ; ret =i2c_smbus_read_byte (client);if (ret <0 ) {dev_err (&client->dev,"cannot read low byte measurement" );return ret; } - val |= ret >>2 ; + val |= ret;return val; }
@@ -212,17 +212,17 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,case IIO_CHAN_INFO_SCALE :if (chan->type ==IIO_TEMP ) { *val =165000 ; - *val2 =65536 >>2 ; + *val2 =65536 ;return IIO_VAL_FRACTIONAL ; }else { - *val =0 ; - *val2 =10000 ; -return IIO_VAL_INT_PLUS_MICRO ; + *val =100 ; + *val2 =65536 ; +return IIO_VAL_FRACTIONAL ; }break ;case IIO_CHAN_INFO_OFFSET : - *val =-3971 ; - *val2 =879096 ; + *val =-15887 ; + *val2 =515151 ;return IIO_VAL_INT_PLUS_MICRO ;default :return -EINVAL ;
Signature · 1 line
2.7.4
Alison,
Can you give a Tested-by: since I don't own this sensor anymore.
Thanks,
Matt
Quoted 57 lines · Matt Ranostay
Shifting sensor data to the right 2 bits was incorrect and caused the scaling values + offsets to be invalid.
Reported-by Alison Schofield <[email protected]>Signed-off-by Matt Ranostay <[email protected]>--- drivers/iio/humidity/hdc100x.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-)drivers/iio/humidity/hdc100x.c +8
-9@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct hdc100x_data *data,dev_err (&client->dev,"cannot read high byte measurement" );return ret; } - val = ret <<6 ; + val = ret <<8 ; ret =i2c_smbus_read_byte (client);if (ret <0 ) {dev_err (&client->dev,"cannot read low byte measurement" );return ret; } - val |= ret >>2 ; + val |= ret;return val; }@@ -212,17 +212,17 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,case IIO_CHAN_INFO_SCALE :if (chan->type ==IIO_TEMP ) { *val =165000 ; - *val2 =65536 >>2 ; + *val2 =65536 ;return IIO_VAL_FRACTIONAL ; }else { - *val =0 ; - *val2 =10000 ; -return IIO_VAL_INT_PLUS_MICRO ; + *val =100 ; + *val2 =65536 ; +return IIO_VAL_FRACTIONAL ; }break ;case IIO_CHAN_INFO_OFFSET : - *val =-3971 ; - *val2 =879096 ; + *val =-15887 ; + *val2 =515151 ;return IIO_VAL_INT_PLUS_MICRO ;default :return -EINVAL ; --2.7.4
Quoted 7 lines · Matt Ranostay
Alison,
Can you give a Tested-by: since I don't own this sensor anymore.
Thanks,
Matt
Tested it. Verified temp & humidty calcs. Looks great!
And, (seeing a pattern here ;)) this comes with another question, probably directed a Jonathan...
with regards to temperature calculations:
Datasheets give numbers for this method:
temp = ((raw * scale) + offset)
IIO drivers report numbers for this method:
temp = ((raw + offset) * scale)
I've figured out the math for translating between them and creating the offset for the driver to report in sysfs, but don't know why we are doing that. 'Our' way seems kind of ugly. For example, for HDC1008 the offset is -40. It's the minimum expected temp value. But, we munge it to be -15887.515151 so we can apply it before scaling.
Why do we do it this way in IIO?
alisons
Quoted 59 lines · Matt Ranostay
Quoted 57 lines
Shifting sensor data to the right 2 bits was incorrect and caused the scaling values + offsets to be invalid.
Reported-by Alison Schofield <[email protected]>Signed-off-by Matt Ranostay <[email protected]>--- drivers/iio/humidity/hdc100x.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-)drivers/iio/humidity/hdc100x.c +8
-9@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct hdc100x_data *data,dev_err (&client->dev,"cannot read high byte measurement" );return ret; } - val = ret <<6 ; + val = ret <<8 ; ret =i2c_smbus_read_byte (client);if (ret <0 ) {dev_err (&client->dev,"cannot read low byte measurement" );return ret; } - val |= ret >>2 ; + val |= ret;return val; }@@ -212,17 +212,17 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,case IIO_CHAN_INFO_SCALE :if (chan->type ==IIO_TEMP ) { *val =165000 ; - *val2 =65536 >>2 ; + *val2 =65536 ;return IIO_VAL_FRACTIONAL ; }else { - *val =0 ; - *val2 =10000 ; -return IIO_VAL_INT_PLUS_MICRO ; + *val =100 ; + *val2 =65536 ; +return IIO_VAL_FRACTIONAL ; }break ;case IIO_CHAN_INFO_OFFSET : - *val =-3971 ; - *val2 =879096 ; + *val =-15887 ; + *val2 =515151 ;return IIO_VAL_INT_PLUS_MICRO ;default :return -EINVAL ; --2.7.4
Quoted 14 lines · Alison Schofield
Quoted 7 lines · Matt Ranostay
Alison,
Can you give a Tested-by: since I don't own this sensor anymore.
Thanks,
Matt
Tested it. Verified temp & humidty calcs. Looks great!
And, (seeing a pattern here ;)) this comes with another question, probably directed a Jonathan...
Quoted 7 lines
with regards to temperature calculations:
Datasheets give numbers for this method:
temp = ((raw * scale) + offset)
IIO drivers report numbers for this method:
temp = ((raw + offset) * scale)
We do it this way in iio.. hence why the offset needs the scaling value applied to it.
Quoted 69 lines
I've figured out the math for translating between them and creating the offset for the driver to report in sysfs, but don't know why we are doing that. 'Our' way seems kind of ugly. For example, for HDC1008 the offset is -40. It's the minimum expected temp value. But, we munge it to be -15887.515151 so we can apply it before scaling.
Why do we do it this way in IIO?
alisons
Quoted 59 lines · Matt Ranostay
Quoted 57 lines
Shifting sensor data to the right 2 bits was incorrect and caused the scaling values + offsets to be invalid.
Reported-by Alison Schofield <[email protected]>Signed-off-by Matt Ranostay <[email protected]>--- drivers/iio/humidity/hdc100x.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-)drivers/iio/humidity/hdc100x.c +8
-9@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct hdc100x_data *data,dev_err (&client->dev,"cannot read high byte measurement" );return ret; } - val = ret <<6 ; + val = ret <<8 ; ret =i2c_smbus_read_byte (client);if (ret <0 ) {dev_err (&client->dev,"cannot read low byte measurement" );return ret; } - val |= ret >>2 ; + val |= ret;return val; }@@ -212,17 +212,17 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,case IIO_CHAN_INFO_SCALE :if (chan->type ==IIO_TEMP ) { *val =165000 ; - *val2 =65536 >>2 ; + *val2 =65536 ;return IIO_VAL_FRACTIONAL ; }else { - *val =0 ; - *val2 =10000 ; -return IIO_VAL_INT_PLUS_MICRO ; + *val =100 ; + *val2 =65536 ; +return IIO_VAL_FRACTIONAL ; }break ;case IIO_CHAN_INFO_OFFSET : - *val =-3971 ; - *val2 =879096 ; + *val =-15887 ; + *val2 =515151 ;return IIO_VAL_INT_PLUS_MICRO ;default :return -EINVAL ; --2.7.4
Jonathan Cameron
maintainerQuoted 26 lines · Matt Ranostay
Quoted 14 lines · Alison Schofield
Quoted 7 lines · Matt Ranostay
Alison,
Can you give a Tested-by: since I don't own this sensor anymore.
Thanks,
Matt
Tested it. Verified temp & humidty calcs. Looks great!
And, (seeing a pattern here ;)) this comes with another question, probably directed a Jonathan...
Quoted 7 lines
with regards to temperature calculations:
Datasheets give numbers for this method:
temp = ((raw * scale) + offset)
IIO drivers report numbers for this method:
temp = ((raw + offset) * scale)We do it this way in iio.. hence why the offset needs the scaling value applied to it.
Quoted 9 lines
Quoted 3 lines
I've figured out the math for translating between them and creating the offset for the driver to report in sysfs, but don't know why we are doing that. 'Our' way seems kind of ugly. For example, for
HDC1008
Quoted 1 line
the offset is -40. It's the minimum expected temp value. But, we
munge
Quoted 3 lines
it to be -15887.515151 so we can apply it before scaling.
Why do we do it this way in IIO?
It is very device dependant or more correctly very data sheet dependant. By coincidence a
lot of early IIO drivers were for parts that had it the other way around so we ended up with that. A classic example is a differential ADC that does an offset rather than 2's complement. Those are much neater offset first.
So six of one and half a dozen of the other...
Jonathan
Quoted 69 lines
Quoted 5 lines
alisons
Quoted 2 lines
On Sun, May 29, 2016 at 7:52 PM, Matt Ranostay <[email protected]>
Quoted 1 line · wrote:
Quoted 1 line
Quoted 1 line
Shifting sensor data to the right 2 bits was incorrect and caused
the
Quoted 9 lines
Quoted 9 lines
Review
Quoted 9 lines
scaling values + offsets to be invalid.
Reported-by Alison Schofield <[email protected]>Signed-off-by Matt Ranostay <[email protected]>--- drivers/iio/humidity/hdc100x.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-)(quoted diff) +0
-0
b/drivers/iio/humidity/hdc100x.cQuoted 4 lines
Quoted 4 lines
drivers/iio/humidity/hdc100x.c static int hdc100x_get_measurement(struct
Quoted 4 lines
index 3070983..a03832a 100644
drivers/iio/humidity/hdc100x.c +0
-0@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct
hdc100x_data*data,Quoted 1 line
Quoted 1 line
drivers/iio/humidity/hdc100x.c static int hdc100x_get_measurement(struct · line 164
Quoted 1 line
drivers/iio/humidity/hdc100x.c +0
-0dev_err(&client->dev, "cannot read high bytemeasurement");
Quoted 8 lines
Quoted 8 lines
drivers/iio/humidity/hdc100x.c static int hdc100x_get_measurement(struct hdc100x_data *data,
Quoted 8 lines
drivers/iio/humidity/hdc100x.c +1
-1return ret; } - val = ret <<6 ; + val = ret <<8 ; ret =i2c_smbus_read_byte (client);if (ret <0 ) { dev_err(&client->dev, "cannot read low bytemeasurement");
Quoted 8 lines
Quoted 8 lines
drivers/iio/humidity/hdc100x.c static int hdc100x_read_raw(struct iio_dev
Quoted 8 lines
drivers/iio/humidity/hdc100x.c +1
-1return ret; } - val |= ret >>2 ; + val |= ret;return val; }@@ -212,17 +212,17 @@ static int hdc100x_read_raw(struct iio_dev
*indio_dev,Quoted 26 lines
Quoted 26 lines
Quoted 26 lines
drivers/iio/humidity/hdc100x.c +6
-7case IIO_CHAN_INFO_SCALE :if (chan->type ==IIO_TEMP ) { *val =165000 ; - *val2 =65536 >>2 ; + *val2 =65536 ;return IIO_VAL_FRACTIONAL ; }else { - *val =0 ; - *val2 =10000 ; -return IIO_VAL_INT_PLUS_MICRO ; + *val =100 ; + *val2 =65536 ; +return IIO_VAL_FRACTIONAL ; }break ;case IIO_CHAN_INFO_OFFSET : - *val =-3971 ; - *val2 =879096 ; + *val =-15887 ; + *val2 =515151 ;return IIO_VAL_INT_PLUS_MICRO ;default :return -EINVAL ; --2.7.4
Signature · 1 line
Sent from my Android device with K-9 Mail. Please excuse my brevity.
Quoted 10 lines · Alison Schofield
Quoted 7 lines · Matt Ranostay
Alison,
Can you give a Tested-by: since I don't own this sensor anymore.
Thanks,
Matt
Tested it. Verified temp & humidty calcs. Looks great!
Ideally please give an explicit tag.
(I've add this time on the basis you meant that I think...) Applied to fixes-togreg and marked for stable. Thanks,
Jonathan
Quoted 80 lines
And, (seeing a pattern here ;)) this comes with another question, probably directed a Jonathan...
with regards to temperature calculations:
Datasheets give numbers for this method:
temp = ((raw * scale) + offset)
IIO drivers report numbers for this method:
temp = ((raw + offset) * scale)I've figured out the math for translating between them and creating the offset for the driver to report in sysfs, but don't know why we are doing that. 'Our' way seems kind of ugly. For example, for HDC1008 the offset is -40. It's the minimum expected temp value. But, we munge it to be -15887.515151 so we can apply it before scaling.
Why do we do it this way in IIO?
alisons
Quoted 59 lines · Matt Ranostay
Quoted 57 lines
Shifting sensor data to the right 2 bits was incorrect and caused the scaling values + offsets to be invalid.
Reported-by Alison Schofield <[email protected]>Signed-off-by Matt Ranostay <[email protected]>--- drivers/iio/humidity/hdc100x.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-)drivers/iio/humidity/hdc100x.c +8
-9@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct hdc100x_data *data,dev_err (&client->dev,"cannot read high byte measurement" );return ret; } - val = ret <<6 ; + val = ret <<8 ; ret =i2c_smbus_read_byte (client);if (ret <0 ) {dev_err (&client->dev,"cannot read low byte measurement" );return ret; } - val |= ret >>2 ; + val |= ret;return val; }@@ -212,17 +212,17 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,case IIO_CHAN_INFO_SCALE :if (chan->type ==IIO_TEMP ) { *val =165000 ; - *val2 =65536 >>2 ; + *val2 =65536 ;return IIO_VAL_FRACTIONAL ; }else { - *val =0 ; - *val2 =10000 ; -return IIO_VAL_INT_PLUS_MICRO ; + *val =100 ; + *val2 =65536 ; +return IIO_VAL_FRACTIONAL ; }break ;case IIO_CHAN_INFO_OFFSET : - *val =-3971 ; - *val2 =879096 ; + *val =-15887 ; + *val2 =515151 ;return IIO_VAL_INT_PLUS_MICRO ;default :return -EINVAL ; --2.7.4