Enable L2 Cache Allocation Technology
cover Enable L2 Cache Allocation Technology
Design document is below:
=======================================================================
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0
\clearpage
Hi all,
We plan to bring a new PSR (Platform Shared Resource) feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
This is the initial design of L2 CAT. It might be a little long and detailed, hope it doesn't matter.
Besides the L2 CAT implementaion, we refactor the psr.c to make it more flexible to add new features and fulfill the principle, open for extension but closed for modification.
Comments and suggestions are welcome :-)
# Basics
---------------- ----------------------------------------------------
Status: **Tech Preview**
Architecture(s): Intel x86
Component(s): Hypervisor, toolstack
Hardware: Atom codename Goldmont and beyond
---------------- ----------------------------------------------------
# Overview
L2 CAT allows an OS or Hypervisor/VMM to control allocation of a CPU's shared L2 cache based on application priority or Class of Service (COS). Each CLOS is configured using capacity bitmasks (CBM) which represent cache capacity and indicate the degree of overlap and isolation between classes. Once L2 CAT is configured, the processor allows access to portions of L2 cache according to the established class of service (COS).
# Technical information
L2 CAT is a member of Intel PSR features and part of CAT, it shares some base PSR infrastructure in Xen.
## Hardware perspective
L2 CAT defines a new range MSRs to assign different L2 cache access patterns which are known as CBMs (Capacity BitMask), each CBM is associated with a COS.
```
+----------------------------+----------------+
IA32_PQR_ASSOC | MSR (per socket) | Address |
+----+---+-------+ +----------------------------+----------------+
| |COS| | | IA32_L2_QOS_MASK_0 | 0xD10 |
+----+---+-------+ +----------------------------+----------------+
└-------------> | ... | ... |
+----------------------------+----------------+
| IA32_L2_QOS_MASK_n | 0xD10+n (n<64) |
+----------------------------+----------------+
```When context switch happens, the COS of VCPU is written to per-thread MSR IA32_PQR_ASSOC, and then hardware enforces L2 cache allocation according to the corresponding CBM.
## The relationship between L2 CAT and L3 CAT/CDP
L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
L2 CAT uses a new range CBMs from 0xD10 ~ 0xD10+n (n<64), following by the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing patterns from L3 cache.
N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same associate register IA32_PQR_ASSOC, which means one COS associate to a pair of L2 CBM and L3 CBM.
Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or other PSR features in future). In some cases, a VM is permitted to have a COS that is beyond one (or more) of PSR features but within the others. For instance, let's assume the max COS of L2 CAT is 8 but the max COS of L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no limit) since COS 9 is beyond the max COS (8) of L2 CAT.
## Design Overview
* Core COS/CBM association
When enforcing L2 CAT, all cores of domains have the same default COS (COS0) which associated to the fully open CBM (all ones bitmask) to access all L2 cache. The default COS is used only in hypervisor and is transparent to tool stack and user.
System administrator can change PSR allocation policy at runtime by tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP is enabled, one COS corresponds to a 3-tuple, like [L2 CBM, L3 Code_CBM, L3 Data_CBM]. If neither L3 CAT nor L3 CDP is enabled, things would be easier, one COS corresponds to one L2 CBM.
* VCPU schedule
This part reuses L3 CAT COS infrastructure.
* Multi-sockets
Different sockets may have different L2 CAT capability (e.g. max COS) although it is consistent on the same socket. So the capability of per-socket L2 CAT is specified.
## Implementation Description
* Hypervisor interfaces:
1. Ext: Boot line parameter "psr=cat" now will enable L2 CAT and L3 CAT if hardware supported.
2. New: SYSCTL:
- XEN_SYSCTL_PSR_CAT_get_l2_info: Get L2 CAT information.
3. New: DOMCTL:
- XEN_DOMCTL_PSR_CAT_OP_GET_L2_CBM: Get L2 CBM for a domain.
- XEN_DOMCTL_PSR_CAT_OP_SET_L2_CBM: Set L2 CBM for a domain.
* xl interfaces:
1. Ext: psr-cat-show -l2 domain-id
Show L2 cbm for a domain.
=> XEN_SYSCTL_PSR_CAT_get_l2_info /
XEN_DOMCTL_PSR_CAT_OP_GET_L2_CBM
2. Ext: psr-mba-set -l2 domain-id cbm
Set L2 cbm for a domain.
=> XEN_DOMCTL_PSR_CAT_OP_SET_L2_CBM
3. Ext: psr-hwinfo
Show PSR HW information, including L2 CAT => XEN_SYSCTL_PSR_CAT_get_l2_info
* Key data structure:
1. Feature list
```
struct feat_list {
unsigned int feature;
struct feat_ops ops;
unsigned int feat_info[MAX_FEAT_INFO_SIZE];
uint64_t cos_reg_val[MAX_COS_REG_NUM];
struct feat_list *pNext;
};
```When a PSR enforcement feature is enabled, it will be added into a feature list. The head of the list is created in psr initialization.
- Member feature
feature is an integer number, to indicate which feature the list member corresponds to.
- Member ops
ops maintains a callback function list of the feature. It will be introduced in details later.
- Member feat_info
feat_info maintains the feature HW information which can be got through psr_hwinfo command.
- Member cos_reg_val
cos_ref_val is an array to maintain the value set in all COS registers of the feature.
2. Per-socket PSR allocation features information structure
```
struct psr_socket_alloc_info {
unsigned int features;
unsigned int nr_feat;
struct feat_list *pFeat;
struct psr_ref *cos_ref;
spinlock_t mask_lock;
};
``` We collect all PSR allocation features information of a socket in this struct psr_socket_alloc_info.
- Member features
features is a bitmap, to indicate which feature is enabled on current socket. We define features bitmap as:
bit 0~1: L3 CAT status, [01] stands for L3 CAT only and [10]
stands for L3 CDP is enalbed.
bit 2: L2 CAT status.
- Member pFeat
pFeat is the head of the feature list which is enabled on the socket.
- Member cos_ref
cos_ref is an array which maintains the reference of one COS. If the COS is used by one domain, the reference will increase one. If a domain releases the COS, the reference will decrease one. The array is indexed by COS.
3. Feature operation functions structure
```
struct feat_ops {
void (*init_feature)(unsigned int eax, unsigned int ebx,
unsigned int ecx, unsigned int edx,
struct feat_list *pFeat,
struct psr_socket_alloc_info *info);
int (*get_old_set_new)(uint64_t *mask,
struct feat_list *pFeat,
unsigned int old_cos,
enum mask_type type,
uint64_t m);
int (*compare_mask)(uint64_t *mask, struct feat_list *pFeat,
unsigned int cos, bool_t *found);
unsigned int (*get_cos_max_as_type)(struct feat_list *pFeat,
enum mask_type type);
unsigned int (*exceed_range)(uint64_t *mask, struct feat_list *pFeat,
unsigned int cos);
int (*write_msr)(unsigned int cos, uint64_t *mask,
struct feat_list *pFeat);
int (*get_val)(struct feat_list *pFeat, unsigned int cos,
enum mask_type type, uint64_t *val);
int (*get_feat_info)(struct feat_list *pFeat, enum mask_type type,
uint32_t *dat0, uint32_t *dat1,
uint32_t *dat2);
unsigned int (*get_max_cos_max)(struct feat_list *pFeat);
};
``` We abstract above callback functions to encapsulate the feature specific behaviors into them. Then, it is easy to add a new feature. We just need:
1) Implement such ops and callback functions for every feature.
2) Register the ops into struct feat_list.
3) Add the feature into feature list during CPU initialization.
# User information
* Feature Enabling:
Add "psr=cat" to boot line parameter to enable all supported level CAT features.
* xl interfaces:
1. psr-cat-show [OPTIONS] domain-id:
Show domain L2 or L3 CAT CBM.
New option -l is added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.
If neither -l2 nor -l3 is given, LLC (Last Level Cache) is default behavior.
2. psr-cat-cbm-set [OPTIONS] domain-id cbm:
Set domain L2 or L3 CBM.
New option -l is added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.
If neither -l2 nor -l3 is given, LLC (Last Level Cache) is default behavior. Since there is no CDP support on L2 cache, so if -l2, --code or --data are both given, error message shows.
3. psr-hwinfo [OPTIONS]:
Show L2 & L3 CAT HW informations on every socket.
# References
[Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)
# History
------------------------------------------------------------------------
Date Revision Version Notes
---------- -------- -------- -------------------------------------------
2016-08-12 1.0 Xen 4.7 Initial design
---------- -------- -------- -------------------------------------------
Yi Sun (3):
x86: refactor psr implementation in hypervisor.
x86: add support for L2 CAT in hypervisor. tools & docs: add L2 CAT support in tools and docs.
docs/man/xl.pod.1.in | 25 +- docs/misc/xl-psr.markdown | 10 +- tools/libxc/include/xenctrl.h | 7 +- tools/libxc/xc_psr.c | 28 +- tools/libxl/libxl.h | 2 + tools/libxl/libxl_psr.c | 50 +- tools/libxl/libxl_types.idl | 1 + tools/libxl/xl_cmdimpl.c | 191 +++++- tools/libxl/xl_cmdtable.c | 4 +- xen/arch/x86/domctl.c | 49 +- xen/arch/x86/psr.c | 1343 ++++++++++++++++++++++++++++++++------- xen/arch/x86/sysctl.c | 19 +- xen/include/asm-x86/msr-index.h | 1 + xen/include/asm-x86/psr.h | 23 +- xen/include/public/domctl.h | 2 + xen/include/public/sysctl.h | 3 +- 16 files changed, 1433 insertions(+), 325 deletions(-)
Signature · 7 lines
1.9.1 _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Quoted 13 lines · Yi Sun
Design document is below:
=======================================================================
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0\clearpage
Hi all,
We plan to bring a new PSR (Platform Shared Resource) feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
Quoted 8 lines
This is the initial design of L2 CAT. It might be a little long and detailed, hope it doesn't matter.
Besides the L2 CAT implementaion, we refactor the
psr.cto make it more flexible to add new features and fulfill the principle, open for extension but closed for modification.Comments and suggestions are welcome :-)
I have some comments/questions. ;-)
Quoted 16 lines
# Basics
---------------- ----------------------------------------------------
Status: **Tech Preview**Architecture(s): Intel x86
Component(s): Hypervisor, toolstack
Hardware: Atom codename Goldmont and beyond
---------------- ----------------------------------------------------# Overview
Quoted 7 lines
L2 CAT allows an OS or Hypervisor/VMM to control allocation of a CPU's shared L2 cache based on application priority or Class of Service (COS). Each CLOS is configured using capacity bitmasks (CBM) which represent cache capacity and indicate the degree of overlap and isolation between classes. Once L2 CAT is configured, the processor allows access to portions of L2 cache according to the established class of service (COS).
The very earlier version of the design at [1] said, "In the initial implementation, L2 CAT is shown up on Atom codename
Goldmont firstly and there is no platform support both L2 & L3 CAT so far."
I'm wondering if there is any hardware supporting both L2 & L3 CAT now.
[1]http://www.gossamer-threads.com/lists/xen/devel/431142
Quoted 26 lines
# Technical information
L2 CAT is a member of Intel PSR features and part of CAT, it shares some base PSR infrastructure in Xen.
## Hardware perspective
L2 CAT defines a new range MSRs to assign different L2 cache access patterns which are known as CBMs (Capacity BitMask), each CBM is associated with a COS.
``` +----------------------------+----------------+ IA32_PQR_ASSOC | MSR (per socket) | Address | +----+---+-------+ +----------------------------+----------------+ | |COS| | | IA32_L2_QOS_MASK_0 | 0xD10 | +----+---+-------+ +----------------------------+----------------+ └-------------> | ... | ... | +----------------------------+----------------+ | IA32_L2_QOS_MASK_n | 0xD10+n (n<64) | +----------------------------+----------------+ ```
Quoted 8 lines
When context switch happens, the COS of VCPU is written to per-thread MSR
IA32_PQR_ASSOC, and then hardware enforces L2 cache allocation according to the corresponding CBM.## The relationship between L2 CAT and L3 CAT/CDP
L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
This sentence indicates that both L2 and L3 CAT can be enabled at the same time. How can I know which CPU supports both L2 and L3 CAT?
Is the support architectural or just on several types of CPUs? IMHO, it will be good to provide a reference about the type of CPUs that supports L2 only, and that both L2 and L3.
Quoted 25 lines
L2 CAT uses a new range CBMs from
0xD10~ 0xD10+n (n<64), following by the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing patterns from L3 cache.N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same associate register
IA32_PQR_ASSOC, which means one COS associate to a pair of L2 CBM and L3 CBM.
Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or other PSR features in future). In some cases, a VM is permitted to have a COS that is beyond one (or more) of PSR features but within the others. For instance, let's assume the max COS of L2 CAT is 8 but the max COS of L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no limit) since COS 9 is beyond the max COS (8) of L2 CAT.## Design Overview
* Core COS/CBM association
When enforcing L2 CAT, all cores of domains have the same default COS (COS0) which associated to the fully open CBM (all ones bitmask) to access all L2 cache. The default COS is used only in hypervisor and is transparent to tool stack and user.
Quoted 6 lines
System administrator can change PSR allocation policy at runtime by tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP is enabled, one COS corresponds to a 3-tuple, like [L2 CBM, L3
Code_CBM, L3Data_CBM]. If neither L3 CAT nor L3 CDP is enabled, things would be easier, one COS corresponds to one L2 CBM.
I felt that this paragraph is kind of confusing. Can system admin configure both L2 and L3 at the same time for a VM? What does the 2-tuple, like [L2 CBM, L3 CBM], indicates here?
In addition, does the bits in CBM have to be continuous?
Quoted 11 lines
# User information
* Feature Enabling:
Add "psr=cat" to boot line parameter to enable all supported level CAT features.
* xl interfaces:
1.
psr-cat-show [OPTIONS] domain-id:
Quoted 8 lines
Show domain L2 or L3 CAT CBM.
New option
-lis added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.If neither
-l2nor-l3is given, LLC (Last Level Cache) is default behavior.
Does it mean the LLC CAT setting will be reset or just kept to the latest configuration?
Quoted 13 lines
2.
psr-cat-cbm-set [OPTIONS] domain-id cbm:Set domain L2 or L3 CBM.
New option
-lis added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.If neither
-l2nor-l3is given, LLC (Last Level Cache) is default behavior. Since there is no CDP support on L2 cache, so if-l2,--codeor--dataare both given, error message shows.
Quoted 7 lines
3.
psr-hwinfo [OPTIONS]:Show L2 & L3 CAT HW informations on every socket.
# References
[Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)
Would you mind provide the chapter for the L2 CAT and the version of the SDM you are referring?
It makes people's life easier to find the reference. ;-)
Quoted 7 lines
# History
------------------------------------------------------------------------
Date Revision Version Notes
---------- -------- -------- -------------------------------------------
2016-08-12 1.0 Xen 4.7 Initial design
It seems there is a RFC design in May this year:
http://www.gossamer-threads.com/lists/xen/devel/431142
Shouldn't it be counted?
Thanks,
Meng
-----------
Meng Xu
PhD Student in Computer and Information Science
University of Pennsylvania
http://www.cis.upenn.edu/~mengxu/
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Quoted 17 lines · Meng Xu
Quoted 16 lines · Yi Sun
Design document is below:
=======================================================================
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0\clearpage
Hi all,
We plan to bring a new PSR (Platform Shared Resource) feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
This is the initial design of L2 CAT. It might be a little long and detailed, hope it doesn't matter.
Quoted 10 lines
Quoted 5 lines
Besides the L2 CAT implementaion, we refactor the
psr.cto make it more flexible to add new features and fulfill the principle, open for extension but closed for modification.Comments and suggestions are welcome :-)
I have some comments/questions. ;-)
Thanks for your comments and questions! :)
Quoted 26 lines
Quoted 16 lines
# Basics
---------------- ----------------------------------------------------
Status: **Tech Preview**Architecture(s): Intel x86
Component(s): Hypervisor, toolstack
Hardware: Atom codename Goldmont and beyond
---------------- ----------------------------------------------------# Overview
Quoted 7 lines
L2 CAT allows an OS or Hypervisor/VMM to control allocation of a CPU's shared L2 cache based on application priority or Class of Service (COS). Each CLOS is configured using capacity bitmasks (CBM) which represent cache capacity and indicate the degree of overlap and isolation between classes. Once L2 CAT is configured, the processor allows access to portions of L2 cache according to the established class of service (COS).
Quoted 9 lines
The very earlier version of the design at [1] said, "In the initial implementation, L2 CAT is shown up on Atom codename
Goldmont firstly and there is no platform support both L2 & L3 CAT so far."I'm wondering if there is any hardware supporting both L2 & L3 CAT now.
Per my info, CURRENT HWs does not support both L2 and L3. But from SW view, we cannot limit this. If both features are enabled in the future HW, SW should be able to support it.
Quoted 32 lines
Quoted 32 lines
# Technical information
L2 CAT is a member of Intel PSR features and part of CAT, it shares some base PSR infrastructure in Xen.
## Hardware perspective
L2 CAT defines a new range MSRs to assign different L2 cache access patterns which are known as CBMs (Capacity BitMask), each CBM is associated with a COS.
``` +----------------------------+----------------+ IA32_PQR_ASSOC | MSR (per socket) | Address | +----+---+-------+ +----------------------------+----------------+ | |COS| | | IA32_L2_QOS_MASK_0 | 0xD10 | +----+---+-------+ +----------------------------+----------------+ └-------------> | ... | ... | +----------------------------+----------------+ | IA32_L2_QOS_MASK_n | 0xD10+n (n<64) | +----------------------------+----------------+ ```When context switch happens, the COS of VCPU is written to per-thread MSR
IA32_PQR_ASSOC, and then hardware enforces L2 cache allocation according to the corresponding CBM.## The relationship between L2 CAT and L3 CAT/CDP
Quoted 9 lines
Quoted 2 lines
L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
This sentence indicates that both L2 and L3 CAT can be enabled at the same time. How can I know which CPU supports both L2 and L3 CAT?
Is the support architectural or just on several types of CPUs? IMHO, it will be good to provide a reference about the type of CPUs that supports L2 only, and that both L2 and L3.
Like above comment, no HWs support both L2 and L3 SO FAR but we should not limit this in SW. By CPUID tool or HW spec, you should know which feature is enabled on CPU.
Quoted 33 lines
Quoted 25 lines
L2 CAT uses a new range CBMs from
0xD10~ 0xD10+n (n<64), following by the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing patterns from L3 cache.N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same associate register
IA32_PQR_ASSOC, which means one COS associate to a pair of L2 CBM and L3 CBM.
Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or other PSR features in future). In some cases, a VM is permitted to have a COS that is beyond one (or more) of PSR features but within the others. For instance, let's assume the max COS of L2 CAT is 8 but the max COS of L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no limit) since COS 9 is beyond the max COS (8) of L2 CAT.## Design Overview
* Core COS/CBM association
When enforcing L2 CAT, all cores of domains have the same default COS (COS0) which associated to the fully open CBM (all ones bitmask) to access all L2 cache. The default COS is used only in hypervisor and is transparent to tool stack and user.
Quoted 6 lines
System administrator can change PSR allocation policy at runtime by tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP is enabled, one COS corresponds to a 3-tuple, like [L2 CBM, L3
Code_CBM, L3Data_CBM]. If neither L3 CAT nor L3 CDP is enabled, things would be easier, one COS corresponds to one L2 CBM.
Quoted 4 lines
I felt that this paragraph is kind of confusing. Can system admin configure both L2 and L3 at the same time for a VM? What does the 2-tuple, like [L2 CBM, L3 CBM], indicates here?
If HW can support both L2 and L3, admin can configure them one by one from SW view. To explain 2-tuple and 3-tuple, please refer below figure.
2-tuple:
-----------------------
| COS 0 | COS 1 | ... |
-----------------------
L3 CAT | 0x7ff | 0x3ff | ... |
-----------------------
L2 CAT | 0xff | 0x3f | ... |
-----------------------3-tuple:
-----------------------------------------------------
| COS 0 DATA | COS 0 CODE | COS 1 DATA | COS 1 CODE |
-----------------------------------------------------
L3 CDP | 0x7ff | 0x7ff | 0x3ff | 0x3ff |
-----------------------------------------------------
| COS 0 | COS 1 |
-----------------------------------------------------
L2 CAT | 0xff | 0x3f |
-----------------------------------------------------There is only one ASSOC MSR register, so a CBM combination(e.g. 3-tuple) will work When you set COS id(e.g. 1) into ASSOC register. That means below CBM set works on the CPU.
L3 CDP DATA=0x3ff
L3 CDP CODE=0x3ff
L2 CAT = 0x3f
Quoted 2 lines
In addition, does the bits in CBM have to be continuous?
Yes, all CBM bits should be continuous. Thanks for pointing this out!
Quoted 17 lines
Quoted 17 lines
# User information
* Feature Enabling:
Add "psr=cat" to boot line parameter to enable all supported level CAT features.
* xl interfaces:
1.
psr-cat-show [OPTIONS] domain-id:Show domain L2 or L3 CAT CBM.
New option
-lis added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.
Quoted 6 lines
Quoted 2 lines
If neither
-l2nor-l3is given, LLC (Last Level Cache) is default behavior.Does it mean the LLC CAT setting will be reset or just kept to the latest configuration?
Here, it means LLC CAT value will be shown.
Quoted 17 lines
Quoted 17 lines
2.
psr-cat-cbm-set [OPTIONS] domain-id cbm:Set domain L2 or L3 CBM.
New option
-lis added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.If neither
-l2nor-l3is given, LLC (Last Level Cache) is default behavior. Since there is no CDP support on L2 cache, so if-l2,--codeor--dataare both given, error message shows.3.
psr-hwinfo [OPTIONS]:Show L2 & L3 CAT HW informations on every socket.
Quoted 8 lines
Quoted 3 lines
# References
[Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)
Would you mind provide the chapter for the L2 CAT and the version of the SDM you are referring?
It makes people's life easier to find the reference. ;-)
Thank you! I will add it in next version.
You can download the latest version from the link. L2 CAT is vol3, chapter 17.17.
Quoted 8 lines
Quoted 7 lines
# History
------------------------------------------------------------------------
Date Revision Version Notes
---------- -------- -------- -------------------------------------------
2016-08-12 1.0 Xen 4.7 Initial design
Quoted 5 lines
It seems there is a RFC design in May this year:
http://www.gossamer-threads.com/lists/xen/devel/431142Shouldn't it be counted?
Ok, thanks!
Quoted 10 lines
Thanks,
Meng
-----------
Meng Xu
PhD Student in Computer and Information Science
University of Pennsylvania
http://www.cis.upenn.edu/~mengxu/
Quoted 4 lines
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Quoted 60 lines · Yi Sun
Quoted 17 lines · Meng Xu
Quoted 16 lines · Yi Sun
Design document is below:
=======================================================================
% Intel L2 Cache Allocation Technology (L2 CAT) Feature % Revision 1.0\clearpage
Hi all,
We plan to bring a new PSR (Platform Shared Resource) feature called Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
This is the initial design of L2 CAT. It might be a little long and detailed, hope it doesn't matter.
Quoted 10 lines
Quoted 5 lines
Besides the L2 CAT implementaion, we refactor the
psr.cto make it more flexible to add new features and fulfill the principle, open for extension but closed for modification.Comments and suggestions are welcome :-)
I have some comments/questions. ;-)
Thanks for your comments and questions! :)
Quoted 30 lines
Quoted 16 lines
# Basics
---------------- ----------------------------------------------------
Status: **Tech Preview**Architecture(s): Intel x86
Component(s): Hypervisor, toolstack
Hardware: Atom codename Goldmont and beyond
---------------- ----------------------------------------------------# Overview
Quoted 7 lines
L2 CAT allows an OS or Hypervisor/VMM to control allocation of a CPU's shared L2 cache based on application priority or Class of Service (COS). Each CLOS is configured using capacity bitmasks (CBM) which represent cache capacity and indicate the degree of overlap and isolation between classes. Once L2 CAT is configured, the processor allows access to portions of L2 cache according to the established class of service (COS).
The very earlier version of the design at [1] said, "In the initial implementation, L2 CAT is shown up on Atom codename
Goldmont firstly and there is no platform support both L2 & L3 CAT so far."
Quoted 8 lines
Quoted 5 lines
I'm wondering if there is any hardware supporting both L2 & L3 CAT now.
Per my info, CURRENT HWs does not support both L2 and L3. But from SW view, we cannot limit this. If both features are enabled in the future HW, SW should be able to support it.
OK. I'm not sure if this is the best way to do it. Since the hw will be manufactured by Intel, I guess you guys know what the future HW will be. ;-)
Actually, the Atom processor that support L2 CAT is similar to the Broadwell processor in the sense that the CAT is only for the Last-Level Cache.
I'm looking forward to the L2 CAT in the processor that has three level cache. ;-)
Quoted 106 lines
Quoted 33 lines
Quoted 33 lines
# Technical information
L2 CAT is a member of Intel PSR features and part of CAT, it shares some base PSR infrastructure in Xen.
## Hardware perspective
L2 CAT defines a new range MSRs to assign different L2 cache access patterns which are known as CBMs (Capacity BitMask), each CBM is associated with a COS.
``` +----------------------------+----------------+ IA32_PQR_ASSOC | MSR (per socket) | Address | +----+---+-------+ +----------------------------+----------------+ | |COS| | | IA32_L2_QOS_MASK_0 | 0xD10 | +----+---+-------+ +----------------------------+----------------+ └-------------> | ... | ... | +----------------------------+----------------+ | IA32_L2_QOS_MASK_n | 0xD10+n (n<64) | +----------------------------+----------------+ ```When context switch happens, the COS of VCPU is written to per-thread MSR
IA32_PQR_ASSOC, and then hardware enforces L2 cache allocation according to the corresponding CBM.## The relationship between L2 CAT and L3 CAT/CDP
Quoted 9 lines
Quoted 2 lines
L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
This sentence indicates that both L2 and L3 CAT can be enabled at the same time. How can I know which CPU supports both L2 and L3 CAT?
Is the support architectural or just on several types of CPUs? IMHO, it will be good to provide a reference about the type of CPUs that supports L2 only, and that both L2 and L3.Like above comment, no HWs support both L2 and L3 SO FAR but we should not limit this in SW. By CPUID tool or HW spec, you should know which feature is enabled on CPU.
Quoted 33 lines
Quoted 25 lines
L2 CAT uses a new range CBMs from
0xD10~ 0xD10+n (n<64), following by the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing patterns from L3 cache.N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same associate register
IA32_PQR_ASSOC, which means one COS associate to a pair of L2 CBM and L3 CBM.
Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or other PSR features in future). In some cases, a VM is permitted to have a COS that is beyond one (or more) of PSR features but within the others. For instance, let's assume the max COS of L2 CAT is 8 but the max COS of L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no limit) since COS 9 is beyond the max COS (8) of L2 CAT.## Design Overview
* Core COS/CBM association
When enforcing L2 CAT, all cores of domains have the same default COS (COS0) which associated to the fully open CBM (all ones bitmask) to access all L2 cache. The default COS is used only in hypervisor and is transparent to tool stack and user.
Quoted 6 lines
System administrator can change PSR allocation policy at runtime by tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP is enabled, one COS corresponds to a 3-tuple, like [L2 CBM, L3
Code_CBM, L3Data_CBM]. If neither L3 CAT nor L3 CDP is enabled, things would be easier, one COS corresponds to one L2 CBM.Quoted 4 lines
I felt that this paragraph is kind of confusing. Can system admin configure both L2 and L3 at the same time for a VM? What does the 2-tuple, like [L2 CBM, L3 CBM], indicates here?
If HW can support both L2 and L3, admin can configure them one by one from SW view. To explain 2-tuple and 3-tuple, please refer below figure.
2-tuple:
----------------------- | COS 0 | COS 1 | ... | ----------------------- L3 CAT | 0x7ff | 0x3ff | ... | ----------------------- L2 CAT | 0xff | 0x3f | ... | -----------------------3-tuple:
----------------------------------------------------- | COS 0 DATA | COS 0 CODE | COS 1 DATA | COS 1 CODE | ----------------------------------------------------- L3 CDP | 0x7ff | 0x7ff | 0x3ff | 0x3ff | ----------------------------------------------------- | COS 0 | COS 1 | ----------------------------------------------------- L2 CAT | 0xff | 0x3f | -----------------------------------------------------
Quoted 6 lines
There is only one ASSOC MSR register, so a CBM combination(e.g. 3-tuple) will work When you set COS id(e.g. 1) into ASSOC register. That means below CBM set works on the CPU.
L3 CDP DATA=0x3ff
L3 CDP CODE=0x3ff
L2 CAT =0x3f
I see. Thank you very much for the explanation!
Quoted 4 lines
Quoted 3 lines
In addition, does the bits in CBM have to be continuous?
Yes, all CBM bits should be continuous. Thanks for pointing this out!
;-)
Quoted 18 lines
Quoted 18 lines
Quoted 18 lines
# User information
* Feature Enabling:
Add "psr=cat" to boot line parameter to enable all supported level CAT features.
* xl interfaces:
1.
psr-cat-show [OPTIONS] domain-id:Show domain L2 or L3 CAT CBM.
New option
-lis added.
-l2: Specify cbm for L2 cache.
-l3: Specify cbm for L3 cache.
Quoted 7 lines
Quoted 6 lines
Quoted 2 lines
If neither
-l2nor-l3is given, LLC (Last Level Cache) is default behavior.Does it mean the LLC CAT setting will be reset or just kept to the latest configuration?
Here, it means LLC CAT value will be shown.
Then the explanation " If neither -l2 nor -l3 is given, LLC (Last Level Cache) is default behavior." could change to
"If neither -l2 nor -l3 is given, it will output the current LLC (Last Level Cache) configuration"
Thank you very much!
Meng
-----------
Meng Xu
PhD Student in Computer and Information Science
University of Pennsylvania
http://www.cis.upenn.edu/~mengxu/
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel