Bluetooth: Fix wrong New Settings event when closing HCI User Channel
Subsystems (2)
Marcel Holtmann
maintainerPATCH 1/1 Bluetooth: Fix wrong New Settings event when closing HCI User Channel
When closing HCI User Channel, the New Settings event was send out to inform about changed settings. However such event is wrong since the exclusive HCI User Channel access is active until the Index Added event has been sent.
@ USER Close: test
@ MGMT Event: New Settings (0x0006) plen 4
Current settings: 0x00000ad0
Bondable
Secure Simple Pairing
BR/EDR
Low Energy
Secure Connections
= Close Index: 00:14:EF:22:04:12
@ MGMT Event: Index Added (0x0004) plen 0
Calling __mgmt_power_off from hci_dev_do_close requires an extra check for an active HCI User Channel.
--- net/bluetooth/hci_core.c | 1 + 1 file changed, 1 insertion(+)
net/bluetooth/hci_core.c +1 -0
@@ -1562,6 +1562,7 @@ int hci_dev_do_close(struct hci_dev *hdev) auto_off =hci_dev_test_and_clear_flag (hdev,HCI_AUTO_OFF );if (!auto_off && hdev->dev_type ==HCI_PRIMARY && + !hci_dev_test_flag (hdev,HCI_USER_CHANNEL ) &&hci_dev_test_flag (hdev,HCI_MGMT ))__mgmt_power_off (hdev);
Signature · 1 line
2.7.4
Johan Hedberg
AppliedHi Marcel,
Quoted 16 lines · Marcel Holtmann
When closing HCI User Channel, the New Settings event was send out to inform about changed settings. However such event is wrong since the exclusive HCI User Channel access is active until the Index Added event has been sent.
@ USER Close: test
@ MGMT Event: New Settings (0x0006) plen 4
Current settings:0x00000ad0
Bondable
Secure Simple Pairing
BR/EDR
Low Energy
Secure Connections
= Close Index: 00:14:EF:22:04:12
@ MGMT Event: Index Added (0x0004) plen 0
Quoted 7 lines
Calling
__mgmt_power_offfromhci_dev_do_closerequires an extra check for an active HCI User Channel.Signed-off-by Marcel Holtmann <[email protected]>--- net/bluetooth/hci_core.c | 1 + 1 file changed, 1 insertion(+)
Applied to bluetooth-next. Thanks.