Skip to contentSkip to conversation

tools/oxenstored: Fix transaction handling in 32bit builds

PATCH Applied Andrew Cooper 3 participants 4 messages Oct 31, 2016

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 tools/oxenstored: Fix transaction handling in 32bit builds

In a 32bit build, the ocaml code 'proposed_id >= 0x7fffffff' compiles to:

  8055eac:       83 fb ff                cmp    $0xffffffff,%ebx
  8055eaf:       7d 0f                   jge    8055ec0 <...+0x20>

which in C is 'proposed_id >= INT_MIN', or in other words, tautologically true. As a result, 32bit builds of oxenstored always try to allocate the transaction id 1, and fall into an infinite loop of trying the next id if transaction 1 is already in use.

Restrict the range down to 1 billion, to sit in the positive half of a 31 bit ocaml integer. The compiled code is now:

  8055eac:       b9 ff ff ff 7f          mov    $0x7fffffff,%ecx
  8055eb1:       39 cb                   cmp    %ecx,%ebx
  8055eb3:       7d 0b                   jge    8055ec0 <...+0x20>

which (other than non-optimal code generation because of the unnecessary use of %ecx), isn't unconditionally true.

In principle, the check could be changed to 'proposed_id == 0x7fffffff' which would still allow for 2 billion transaction in 32bit builds. However, in 64bit builds, this reintroduces a risk that if proposed_id is initially greater than 0x7fffffff, it will not be clipped suitably into range.

---
CC: Ian Jackson <[email protected]>
CC: Wei Liu <[email protected]>
CC: David Scott <[email protected]>

---
 tools/ocaml/xenstored/connection.ml | 12 ++++++++++--
 1 file changed, 10 insertions(+), 2 deletions(-)
tools/ocaml/xenstored/connection.ml +10 -2
index 0b47009..3ffd35b 100644
@@ -218,8 +218,16 @@ let fire_watch watch path =
 
 (* Search for a valid unused transaction id. *)
 let rec valid_transaction_id con proposed_id =
-	(* Clip proposed_id to the range [1, 0x7ffffffe] *)
-	let id = if proposed_id <= 0 || proposed_id >= 0x7fffffff then 1 else proposed_id in
+	(*
+	 * Clip proposed_id to the range [1, 0x3ffffffe]
+	 *
+	 * The chosen id must not trucate when written into the uint32_t tx_id
+	 * field, and needs to fit within the positive range of a 31 bit ocaml
+	 * integer to function when compiled as 32bit.
+	 *
+	 * Oxenstored therefore supports only 1 billion open transactions.
+	 *)
+	let id = if proposed_id <= 0 || proposed_id >= 0x3fffffff then 1 else proposed_id in
 
 	if Hashtbl.mem con.transactions id then (
 		(* Outstanding transaction with this id.  Try the next. *)
Signature · 7 lines
2.1.4


_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Reviewed-by on v1 1/1
#1 lore raw
Quoted 20 lines · Andrew Cooper

In a 32bit build, the ocaml code 'proposed_id >= 0x7fffffff' compiles to:

  8055eac:       83 fb ff                cmp    $0xffffffff,%ebx
  8055eaf:       7d 0f                   jge    8055ec0 <...+0x20>

which in C is 'proposed_id >= INT_MIN', or in other words, tautologically true. As a result, 32bit builds of oxenstored always try to allocate the transaction id 1, and fall into an infinite loop of trying the next id if transaction 1 is already in use.

Restrict the range down to 1 billion, to sit in the positive half of a 31 bit ocaml integer. The compiled code is now:

  8055eac:       b9 ff ff ff 7f          mov    $0x7fffffff,%ecx
  8055eb1:       39 cb                   cmp    %ecx,%ebx
  8055eb3:       7d 0b                   jge    8055ec0 <...+0x20>

which (other than non-optimal code generation because of the unnecessary use of %ecx), isn't unconditionally true.

Quoted 6 lines

In principle, the check could be changed to 'proposed_id == 0x7fffffff' which would still allow for 2 billion transaction in 32bit builds. However, in 64bit builds, this reintroduces a risk that if proposed_id is initially greater than 0x7fffffff, it will not be clipped suitably into range.

_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel

Acked-by
#2 lore raw
Quoted 24 lines · Wei Liu
Quoted 20 lines · Andrew Cooper

In a 32bit build, the ocaml code 'proposed_id >= 0x7fffffff' compiles to:

 8055eac:       83 fb ff                cmp    $0xffffffff,%ebx
 8055eaf:       7d 0f                   jge    8055ec0 <...+0x20>

which in C is 'proposed_id >= INT_MIN', or in other words, tautologically true. As a result, 32bit builds of oxenstored always try to allocate the transaction id 1, and fall into an infinite loop of trying the next id if transaction 1 is already in use.

Restrict the range down to 1 billion, to sit in the positive half of a 31 bit ocaml integer. The compiled code is now:

 8055eac:       b9 ff ff ff 7f          mov    $0x7fffffff,%ecx
 8055eb1:       39 cb                   cmp    %ecx,%ebx
 8055eb3:       7d 0b                   jge    8055ec0 <...+0x20>

which (other than non-optimal code generation because of the unnecessary use of %ecx), isn't unconditionally true.

Quoted 8 lines
Quoted 6 lines

In principle, the check could be changed to 'proposed_id == 0x7fffffff' which would still allow for 2 billion transaction in 32bit builds. However, in 64bit builds, this reintroduces a risk that if proposed_id is initially greater than 0x7fffffff, it will not be clipped suitably into range.

_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel

Applied
#3 lore raw
Quoted 29 lines · David Scott
Quoted 29 lines · Wei Liu
Quoted 25 lines · Andrew Cooper

In a 32bit build, the ocaml code 'proposed_id >= 0x7fffffff' compiles to:

 8055eac:       83 fb ff                cmp    $0xffffffff,%ebx
 8055eaf:       7d 0f                   jge    8055ec0 <...+0x20>

which in C is 'proposed_id >= INT_MIN', or in other words, tautologically true. As a result, 32bit builds of oxenstored always try to allocate the transaction id 1, and fall into an infinite loop of trying the next id if transaction 1 is already in use.

Restrict the range down to 1 billion, to sit in the positive half of a 31 bit ocaml integer. The compiled code is now:

 8055eac:       b9 ff ff ff 7f          mov    $0x7fffffff,%ecx
 8055eb1:       39 cb                   cmp    %ecx,%ebx
 8055eb3:       7d 0b                   jge    8055ec0 <...+0x20>

which (other than non-optimal code generation because of the unnecessary use of %ecx), isn't unconditionally true.

In principle, the check could be changed to 'proposed_id == 0x7fffffff' which would still allow for 2 billion transaction in 32bit builds. However, in 64bit builds, this reintroduces a risk that if proposed_id is initially greater than 0x7fffffff, it will not be clipped suitably into range.

Quoted 6 lines
Quoted 3 lines
Quoted 1 line

Applied. Thanks.