mfd: da9062: make register CONFIG_I writable
Subsystems (5)
PATCH v2 1/4 mfd: da9062: make register CONFIG_I writable
From: Stefan Christ <[email protected]>
Make the config register CONFIG_I writable to change the watchdog mode.
--- drivers/mfd/da9062-core.c | 1 + 1 file changed, 1 insertion(+)
drivers/mfd/da9062-core.c +1 -0
@@ -556,6 +556,7 @@ static const struct regmap_range da9062_aa_writeable_ranges[] = {regmap_reg_range (DA9062AA_VBUCK3_B ,DA9062AA_VBUCK3_B ),regmap_reg_range (DA9062AA_VLDO1_B ,DA9062AA_VLDO4_B ),regmap_reg_range (DA9062AA_BBAT_CONT ,DA9062AA_BBAT_CONT ), +regmap_reg_range (DA9062AA_CONFIG_I ,DA9062AA_CONFIG_I ), regmap_reg_range(DA9062AA_GP_ID_0, DA9062AA_GP_ID_19), };
Signature · 1 line
2.25.1
PATCH v2 2/4 watchdog: da9062: reset board on watchdog timeout
Implement a method to change watchdog timeout configuration based on DT binding ("dlg,wdt-sd"). There is a possibility to change the bahaviour of watchdog reset. Setting WATCHDOG_SD bit enables SHUTDOWN mode, and clearing it enables POWERDOWN mode on watchdog timeout.
If no DT binding is specified the WATCHDOG_SD bit stays in default configuration, not breaking behaviour of devices which might depend on default fuse configuration.
Note: This patch requires that the config register CONFIG_I is configured as writable in the da9062 multi function device.
--- drivers/watchdog/da9062_wdt.c | 25 +++++++++++++++++++++++++ 1 file changed, 25 insertions(+)
drivers/watchdog/da9062_wdt.c +25 -0
@@ -85,8 +85,33 @@ static int da9062_wdt_start(struct watchdog_device *wdd) {struct da9062_watchdog *wdt =watchdog_get_drvdata (wdd);unsigned int selector; +unsigned int mask; +u32 val;int ret; +/* Configure what happens on watchdog timeout. Can be specified with +* "dlg,wdt-sd" dt-binding (0 -> POWERDOWN, 1 -> SHUTDOWN). +* If "dlg,wdt-sd" dt-binding is NOT set use the default. +*/ + ret =device_property_read_u32 (wdd->parent,"dlg,wdt-sd" , &val); +if (!ret) { +if (val) +/* Use da9062's SHUTDOWN mode */ + mask =DA9062AA_WATCHDOG_SD_MASK ; +else +/* Use da9062's POWERDOWN mode. */ + mask =0x0 ; + + ret =regmap_update_bits (wdt->hw->regmap, +DA9062AA_CONFIG_I , +DA9062AA_WATCHDOG_SD_MASK , + mask); + +if (ret) +dev_err (wdt->hw->dev,"failed to set wdt reset mode: %d\n" , + ret); + } + selector =da9062_wdt_timeout_to_sel (wdt->wdtdev.timeout); ret =da9062_wdt_update_timeout_register (wdt, selector);if (ret)
Signature · 1 line
2.25.1
Re: [PATCH v2 2/4] watchdog: da9062: reset board on watchdog timeout
Quoted 46 lines · Andrej Picej
Implement a method to change watchdog timeout configuration based on DT binding ("dlg,wdt-sd"). There is a possibility to change the bahaviour of watchdog reset. Setting
WATCHDOG_SDbit enables SHUTDOWN mode, and clearing it enables POWERDOWN mode on watchdog timeout.If no DT binding is specified the
WATCHDOG_SDbit stays in default configuration, not breaking behaviour of devices which might depend on default fuse configuration.Note: This patch requires that the config register
CONFIG_Iis configured as writable in the da9062 multi function device.Signed-off-by Andrej Picej <[email protected]>--- drivers/watchdog/da9062_wdt.c | 25 +++++++++++++++++++++++++ 1 file changed, 25 insertions(+)drivers/watchdog/da9062_wdt.c +18
-0@@ -85,8 +85,33 @@ static int da9062_wdt_start(struct watchdog_device *wdd) {struct da9062_watchdog *wdt =watchdog_get_drvdata (wdd);unsigned int selector; +unsigned int mask; +u32 val;int ret; +/* Configure what happens on watchdog timeout. Can be specified with +* "dlg,wdt-sd" dt-binding (0 -> POWERDOWN, 1 -> SHUTDOWN). +* If "dlg,wdt-sd" dt-binding is NOT set use the default. +*/ + ret =device_property_read_u32 (wdd->parent,"dlg,wdt-sd" , &val); +if (!ret) { +if (val) +/* Use da9062's SHUTDOWN mode */ + mask =DA9062AA_WATCHDOG_SD_MASK ; +else +/* Use da9062's POWERDOWN mode. */ + mask =0x0 ; + + ret = regmap_update_bits(wdt->hw->regmap, + DA9062AA_CONFIG_I, + DA9062AA_WATCHDOG_SD_MASK,
drivers/watchdog/da9062_wdt.c static int da9062_wdt_start(struct watchdog_device *wdd) · line 117
Quoted 10 lines
drivers/watchdog/da9062_wdt.c +7
-0+ mask); + +if (ret) +dev_err (wdt->hw->dev,"failed to set wdt reset mode: %d\n" , + ret); + } + selector =da9062_wdt_timeout_to_sel (wdt->wdtdev.timeout); ret =da9062_wdt_update_timeout_register (wdt, selector);if (ret)
Changes in v2:
- don't force the "reset" for all da9062-watchdog users, instead add DT binding where the behavior can be selected
PATCH v2 3/4 dt-bindings: watchdog: da9062: add watchdog timeout mode
In reply to Andrej PicejDocument the watchdog timeout mode property. If this property is used the user can select what happens on watchdog timeout. Set this property to 1 to enable SHUTDOWN (the device resets), set it to 0 and the device will go to POWERDOWN on watchdog timeout.
--- Documentation/devicetree/bindings/watchdog/da9062-wdt.txt | 3 +++ 1 file changed, 3 insertions(+)
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +3 -0
@@ -10,6 +10,9 @@ Optional properties: - dlg,use-sw-pm: Add this property to disable the watchdog during suspend. Only use this option if you can't use the watchdog automatic suspend function during a suspend (see register CONTROL_B). +- dlg,wdt-sd: Set what happens on watchdog timeout. If this bit is set the + watchdog timeout triggers SHUTDOWN, if cleared the watchdog triggers + POWERDOWN. Can be 0 or 1. Example: DA9062
Signature · 1 line
2.25.1
Re: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 16 lines · Andrej Picej
Document the watchdog timeout mode property. If this property is used the user can select what happens on watchdog timeout. Set this property to 1 to enable SHUTDOWN (the device resets), set it to 0 and the device will go to POWERDOWN on watchdog timeout.
Signed-off-by Andrej Picej <[email protected]>--- Documentation/devicetree/bindings/watchdog/da9062-wdt.txt | 3 +++ 1 file changed, 3 insertions(+)Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +0
-0
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt Optional properties: · line 18
Quoted 9 lines
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +3
-0@@ -10,6 +10,9 @@ Optional properties: - dlg,use-sw-pm: Add this property to disable the watchdog during suspend. Only use this option if you can't use the watchdog automatic suspend function during a suspend (see register CONTROL_B). +- dlg,wdt-sd: Set what happens on watchdog timeout. If this bit is set the + watchdog timeout triggers SHUTDOWN, if cleared the watchdog triggers + POWERDOWN. Can be 0 or 1. Example: DA9062
Changes in v2:
- new patch, document new DT binding
Guenter Roeck
maintainerRe: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
In reply to Andrej PicejQuoted 15 lines · Andrej Picej
Document the watchdog timeout mode property. If this property is used the user can select what happens on watchdog timeout. Set this property to 1 to enable SHUTDOWN (the device resets), set it to 0 and the device will go to POWERDOWN on watchdog timeout.
Signed-off-by Andrej Picej <[email protected]>--- Documentation/devicetree/bindings/watchdog/da9062-wdt.txt | 3 +++ 1 file changed, 3 insertions(+)Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +0
-0
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt Optional properties: · line 16
Quoted 7 lines
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +3
-0@@ -10,6 +10,9 @@ Optional properties: - dlg,use-sw-pm: Add this property to disable the watchdog during suspend. Only use this option if you can't use the watchdog automatic suspend function during a suspend (see register CONTROL_B). +- dlg,wdt-sd: Set what happens on watchdog timeout. If this bit is set the + watchdog timeout triggers SHUTDOWN, if cleared the watchdog triggers + POWERDOWN. Can be 0 or 1.
Why does it need a value ? Why not just bool ?
Guenter
RE: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 12 lines · On Guenter Roeck wrote:
Review
Quoted 11 lines
Document the watchdog timeout mode property. If this property is used the user can select what happens on watchdog timeout. Set this property to 1 to enable SHUTDOWN (the device resets), set it to 0 and the device will go to POWERDOWN on watchdog timeout.
Signed-off-by Andrej Picej <[email protected]>--- Documentation/devicetree/bindings/watchdog/da9062-wdt.txt | 3 +++ 1 file changed, 3 insertions(+)(quoted diff) +0
-0
b/Documentation/devicetree/bindings/watchdog/da9062-wdt.txt
Quoted 13 lines
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt Optional properties: · line 16
Quoted 11 lines
index
950e4fba8dbc..e3e6e56cee21100644Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +3
-0@@ -10,6 +10,9 @@ Optional properties: - dlg,use-sw-pm: Add this property to disable the watchdog during suspend. Only use this option if you can't use the watchdog automatic suspend function during a suspend (see register CONTROL_B). +- dlg,wdt-sd: Set what happens on watchdog timeout. If this bit is set the + watchdog timeout triggers SHUTDOWN, if cleared the watchdog triggers + POWERDOWN. Can be 0 or 1.Why does it need a value ? Why not just bool ?
One argument might be that if the property isn't provided then the OTP configured value can persist without needing a FW change around this DT binding.
My belief though is that the majority of users would have this property set to 0 by default in OTP, so a boolean would be OK I think here to enable watchdog shutdown.
Guenter Roeck
maintainerRe: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 28 lines · Adam Thomson
Quoted 12 lines · On Guenter Roeck wrote:
Review
Quoted 11 lines
Document the watchdog timeout mode property. If this property is used the user can select what happens on watchdog timeout. Set this property to 1 to enable SHUTDOWN (the device resets), set it to 0 and the device will go to POWERDOWN on watchdog timeout.
Signed-off-by Andrej Picej <[email protected]>--- Documentation/devicetree/bindings/watchdog/da9062-wdt.txt | 3 +++ 1 file changed, 3 insertions(+)(quoted diff) +0
-0
b/Documentation/devicetree/bindings/watchdog/da9062-wdt.txtQuoted 13 lines
Documentation/devicetree/bindings/watchdog/da9062-wdt.txt Optional properties: · line 16
Quoted 11 lines
index
950e4fba8dbc..e3e6e56cee21100644Documentation/devicetree/bindings/watchdog/da9062-wdt.txt +3
-0@@ -10,6 +10,9 @@ Optional properties: - dlg,use-sw-pm: Add this property to disable the watchdog during suspend. Only use this option if you can't use the watchdog automatic suspend function during a suspend (see register CONTROL_B). +- dlg,wdt-sd: Set what happens on watchdog timeout. If this bit is set the + watchdog timeout triggers SHUTDOWN, if cleared the watchdog triggers + POWERDOWN. Can be 0 or 1.Why does it need a value ? Why not just bool ?
Quoted 7 lines
One argument might be that if the property isn't provided then the OTP configured value can persist without needing a FW change around this DT binding.
My belief though is that the majority of users would have this property set to 0 by default in OTP, so a boolean would be OK I think here to enable watchdog shutdown.
Sorry, you lost me.
dlg,wdt-sd = <0>; is the current situation, and identical to not having the property in the first place. dlg,wdt-sd = <1>; is new. I don't see the difference to dlg,wdt-sd; vs. not having the property at all (which is, again, the current situation). Since it has to be backward compatible, dlg,wdt-sd = <0>;
will always be identical to not having the property at all.
I can not find a situation where an integer would have any benefits over a boolean.
Guenter
RE: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 21 lines · Guenter Roeck
Quoted 4 lines
Quoted 1 line
Why does it need a value ? Why not just bool ?
One argument might be that if the property isn't provided then the OTP configured value can persist without needing a FW change around this DT
binding.
Quoted 5 lines
My belief though is that the majority of users would have this property set to 0 by default in OTP, so a boolean would be OK I think here to enable watchdog shutdown.
Sorry, you lost me.
dlg,wdt-sd = <0>; is the current situation, and identical to not having the property in the first place. dlg,wdt-sd = <1>; is new. I don't see the difference to dlg,wdt-sd; vs. not having the property at all (which is, again, the current situation). Since it has to be backward compatible, dlg,wdt-sd = <0>;
Quoted 3 lines
will always be identical to not having the property at all.
I can not find a situation where an integer would have any benefits over a boolean.
So if you have a binary DT binding, it's either there or it isn't which implies the bit to be set to 0/1 in this case. If you have a binding which has a value, there can be 3 outcomes in this discussion:
1) Binding = 0, bit is set to 0
2) Binding = 1, bit is set to 1
3) Binding NOT present in DT, OTP default value in HW remains untouched
Say a platform updates to a later kernel version, but sticks with existing DT FW (i.e. the new boolean binding isn't present in FW), then the following could happen:
1) OTP for DA9061/2 has this bit set to 1, system expectation is that watchdog triggers SHUTDOWN.
2) New driver checks existance of 'dlg,wdt-sd' but it's obviously not there so assumes the bit should be set to 0 and does so
3) When the watchdog fires, it will no longer trigger SHUTDOWN but instead POWER-DOWN due to binary handling of new boolean binding.
Re: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 39 lines · Adam Thomson
Quoted 21 lines · Guenter Roeck
Quoted 4 lines
Quoted 1 line
Why does it need a value ? Why not just bool ?
One argument might be that if the property isn't provided then the OTP configured value can persist without needing a FW change around this DT
binding.
Quoted 5 lines
My belief though is that the majority of users would have this property set to 0 by default in OTP, so a boolean would be OK I think here to enable watchdog shutdown.
Sorry, you lost me.
dlg,wdt-sd = <0>; is the current situation, and identical to not having the property in the first place. dlg,wdt-sd = <1>; is new. I don't see the difference to dlg,wdt-sd; vs. not having the property at all (which is, again, the current situation). Since it has to be backward compatible, dlg,wdt-sd = <0>;Quoted 3 lines
will always be identical to not having the property at all.
I can not find a situation where an integer would have any benefits over a boolean.So if you have a binary DT binding, it's either there or it isn't which implies the bit to be set to 0/1 in this case. If you have a binding which has a value, there can be 3 outcomes in this discussion:
1) Binding = 0, bit is set to 0
2) Binding = 1, bit is set to 1
3) Binding NOT present in DT, OTP default value in HW remains untouchedSay a platform updates to a later kernel version, but sticks with existing DT FW (i.e. the new boolean binding isn't present in FW), then the following could happen:
Quoted 7 lines
1) OTP for DA9061/2 has this bit set to 1, system expectation is that watchdog triggers SHUTDOWN.
2) New driver checks existance of 'dlg,wdt-sd' but it's obviously not there so assumes the bit should be set to 0 and does so
3) When the watchdog fires, it will no longer trigger SHUTDOWN but instead POWER-DOWN due to binary handling of new boolean binding.
This was my thinking exactly. I also first thought about boolean value, but I then moved to the integer value of 0 or 1 after checking the OTP default for this bit. The da9062 I'm working with has the bit set to 1 by default.
Guenter Roeck
maintainerRe: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 49 lines · Andrej Picej
Quoted 39 lines · Adam Thomson
Quoted 11 lines · Guenter Roeck
Quoted 4 lines
Quoted 1 line
Why does it need a value ? Why not just bool ?
One argument might be that if the property isn't provided then the OTP configured value can persist without needing a FW change around this DT
binding.
Quoted 5 lines
My belief though is that the majority of users would have this property set to 0 by default in OTP, so a boolean would be OK I think here to enable watchdog shutdown.
Quoted 13 lines
Sorry, you lost me.
dlg,wdt-sd = <0>;
is the current situation, and identical to not having the property in the first place.
dlg,wdt-sd = <1>;
is new. I don't see the difference to
dlg,wdt-sd;
vs. not having the property at all (which is, again, the current situation). Since it has to be backward compatible,
dlg,wdt-sd = <0>;
will always be identical to not having the property at all.
I can not find a situation where an integer would have any benefits over a boolean.So if you have a binary DT binding, it's either there or it isn't which implies the bit to be set to 0/1 in this case. If you have a binding which has a value, there can be 3 outcomes in this discussion:
1) Binding = 0, bit is set to 0
2) Binding = 1, bit is set to 1
3) Binding NOT present in DT, OTP default value in HW remains untouchedSay a platform updates to a later kernel version, but sticks with existing DT FW (i.e. the new boolean binding isn't present in FW), then the following could happen:
Quoted 7 lines
1) OTP for DA9061/2 has this bit set to 1, system expectation is that watchdog triggers SHUTDOWN.
2) New driver checks existance of 'dlg,wdt-sd' but it's obviously not there so assumes the bit should be set to 0 and does so
3) When the watchdog fires, it will no longer trigger SHUTDOWN but instead POWER-DOWN due to binary handling of new boolean binding.
Quoted 1 line
This was my thinking exactly. I also first thought about boolean value, but I then moved to the integer value of 0 or 1 after checking the OTP default for this bit. The da9062 I'm working with has the bit set to 1 by default.
That needs to be be documented.
Guenter
Re: [PATCH v2 3/4] dt-bindings: watchdog: da9062: add watchdog timeout mode
Quoted 50 lines · Guenter Roeck
Quoted 49 lines · Andrej Picej
Quoted 46 lines · Adam Thomson
Quoted 11 lines · Guenter Roeck
Quoted 4 lines
Quoted 1 line
Why does it need a value ? Why not just bool ?
One argument might be that if the property isn't provided then the OTP configured value can persist without needing a FW change around this DT
binding.
Quoted 5 lines
My belief though is that the majority of users would have this property set to 0 by default in OTP, so a boolean would be OK I think here to enable watchdog shutdown.
Quoted 13 lines
Sorry, you lost me.
dlg,wdt-sd = <0>;
is the current situation, and identical to not having the property in the first place.
dlg,wdt-sd = <1>;
is new. I don't see the difference to
dlg,wdt-sd;
vs. not having the property at all (which is, again, the current situation). Since it has to be backward compatible,
dlg,wdt-sd = <0>;
will always be identical to not having the property at all.
I can not find a situation where an integer would have any benefits over a boolean.So if you have a binary DT binding, it's either there or it isn't which implies the bit to be set to 0/1 in this case. If you have a binding which has a value, there can be 3 outcomes in this discussion:
1) Binding = 0, bit is set to 0
2) Binding = 1, bit is set to 1
3) Binding NOT present in DT, OTP default value in HW remains untouchedSay a platform updates to a later kernel version, but sticks with existing DT FW (i.e. the new boolean binding isn't present in FW), then the following could happen:
1) OTP for DA9061/2 has this bit set to 1, system expectation is that watchdog triggers SHUTDOWN.
2) New driver checks existance of 'dlg,wdt-sd' but it's obviously not there so assumes the bit should be set to 0 and does so
3) When the watchdog fires, it will no longer trigger SHUTDOWN but instead POWER-DOWN due to binary handling of new boolean binding.
Quoted 5 lines
Quoted 1 line
This was my thinking exactly. I also first thought about boolean value, but I then moved to the integer value of 0 or 1 after checking the OTP default for this bit. The da9062 I'm working with has the bit set to 1 by default.
That needs to be be documented.
Guenter
Ok, I will add a note about the default value and how it is defined by OTP. Will submit a v3.
Thanks for review.
BR,
Andrej
PATCH v2 4/4 ARM: dts: imx6: phycore-som: set watchdog timeout mode to shutdown
In reply to Andrej PicejEnable system restart when the watchdog timeout occurs.
--- arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi | 1 + 1 file changed, 1 insertion(+)
arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi +1 -0
@@ -111,6 +111,7 @@ da9062_onkey: onkey { watchdog { compatible = "dlg,da9062-watchdog"; dlg,use-sw-pm; + dlg,wdt-sd = <1>; }; regulators {
Signature · 1 line
2.25.1
Re: [PATCH v2 4/4] ARM: dts: imx6: phycore-som: set watchdog timeout mode to shutdown
Quoted 13 lines · Andrej Picej
Enable system restart when the watchdog timeout occurs.
Signed-off-by Andrej Picej <[email protected]>--- arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi | 1 + 1 file changed, 1 insertion(+)arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi +0
-0
arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi da9062_onkey: onkey { · line 117
Quoted 7 lines
arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi +1
-0@@ -111,6 +111,7 @@ da9062_onkey: onkey { watchdog { compatible = "dlg,da9062-watchdog"; dlg,use-sw-pm; + dlg,wdt-sd = <1>; }; regulators {
Changes in v2:
- new patch, enable shutdown mode for phytec-phycore (da9062 user)
Guenter Roeck
maintainerRe: [PATCH v2 4/4] ARM: dts: imx6: phycore-som: set watchdog timeout mode to shutdown
In reply to Andrej PicejQuoted 12 lines · Andrej Picej
Enable system restart when the watchdog timeout occurs.
Signed-off-by Andrej Picej <[email protected]>--- arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi | 1 + 1 file changed, 1 insertion(+)arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi +0
-0
arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi da9062_onkey: onkey { · line 114
Quoted 4 lines
arch/arm/boot/dts/imx6qdl-phytec-phycore-som.dtsi +1
-0@@ -111,6 +111,7 @@ da9062_onkey: onkey { watchdog { compatible = "dlg,da9062-watchdog"; dlg,use-sw-pm; + dlg,wdt-sd = <1>;
dlg,wdt-sd should be defined as bool.
Guenter
Hi,
Quoted 16 lines · Andrej Picej
From: Stefan Christ <[email protected]>
Make the config register
CONFIG_Iwritable to change the watchdog mode.Signed-off-by Stefan Christ <[email protected]>Signed-off-by Andrej Picej <[email protected]>--- drivers/mfd/da9062-core.c | 1 + 1 file changed, 1 insertion(+)drivers/mfd/da9062-core.c +0
-0
drivers/mfd/da9062-core.c static const struct regmap_range da9062_aa_writeable_ranges[] = { · line 562
Quoted 7 lines
drivers/mfd/da9062-core.c +1
-0@@ -556,6 +556,7 @@ static const struct regmap_range da9062_aa_writeable_ranges[] = {regmap_reg_range (DA9062AA_VBUCK3_B ,DA9062AA_VBUCK3_B ),regmap_reg_range (DA9062AA_VLDO1_B ,DA9062AA_VLDO4_B ),regmap_reg_range (DA9062AA_BBAT_CONT ,DA9062AA_BBAT_CONT ), +regmap_reg_range (DA9062AA_CONFIG_I ,DA9062AA_CONFIG_I ), regmap_reg_range(DA9062AA_GP_ID_0, DA9062AA_GP_ID_19), };
Changes in v2:
- no changes
sorry, just noticed I forgot to add what I changed for v2 patch series. Should I resend the patches with that fixed/added? Should that be v3 then or still v2?
Thanks.