dt-bindings: iio: adc: ti-ads1298: Add bindings
Subsystems (2)
A message that is not in the archive (sent off-list or not yet received): 1b153bce-a66a-45ee-a5c6-963ea6fb1c82.949ef384-8293-46b8-903f-40a477c056ae.b967e427-f7fa-4912-936e-caf944d735e9@emailsignatures365.codetwo.com
PATCH v4 1/2 dt-bindings: iio: adc: ti-ads1298: Add bindings
Bindings for the TI ADS1298 medical ADC. This device is typically used for ECG and similar measurements. Supports data acquisition at configurable scale and sampling frequency.
The device has so many options for connecting stuff, at this point the bindings aren't nearly complete but partial bindings are better than no bindings at all.
---
(no changes since v2)
Changes in v2:
Remove "clk" name
Add datasheet and "incomplete" note
.../bindings/iio/adc/ti,ads1298.yaml | 80 +++++++++++++++++++ 1 file changed, 80 insertions(+) create mode 100644 Documentation/devicetree/bindings/iio/adc/ti,ads1298.yaml
Documentation/devicetree/bindings/iio/adc/ti,ads1298.yaml new file +80 -0
@@ -0,0 +1,80 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/iio/adc/ti,ads1298.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Texas Instruments' ads1298 medical ADC chips + +description: | + Datasheet at: https://www.ti.com/product/ADS1298 + Bindings for this chip aren't complete. + +maintainers: + - Mike Looijmans <[email protected]> + +properties: + compatible: + enum: + - ti,ads1298 + + reg: + maxItems: 1 + + spi-cpha: true + + reset-gpios: + maxItems: 1 + + avdd-supply: + description: + Analog power supply, voltage between AVDD and AVSS. When providing a + symmetric +/- 2.5V, the regulator should report 5V. + + vref-supply: + description: + Optional reference voltage. If omitted, internal reference is used, + which is 2.4V when analog supply is below 4.4V, 4V otherwise. + + clocks: + description: Optional 2.048 MHz external source clock on CLK pin + maxItems: 1 + + interrupts: + description: Interrupt on DRDY pin, triggers on falling edge + maxItems: 1 + + label: true + +required: + - compatible + - reg + - avdd-supply + - interrupts + +allOf: + - $ref: /schemas/spi/spi-peripheral-props.yaml# + +unevaluatedProperties: false + +examples: + - | + #include <dt-bindings/gpio/gpio.h> + #include <dt-bindings/interrupt-controller/irq.h> + spi { + #address-cells = <1>; + #size-cells = <0>; + + adc@1 { + reg = <1>; + compatible = "ti,ads1298"; + label = "ads1298-1-ecg"; + avdd-supply = <®_iso_5v_a>; + clocks = <&clk_ads1298>; + interrupt-parent = <&gpio0>; + interrupts = <78 IRQ_TYPE_EDGE_FALLING>; + spi-max-frequency = <20000000>; + spi-cpha; + }; + }; +...
Signature · 18 lines
2.34.1 Met vriendelijke groet / kind regards, Mike Looijmans System Expert TOPIC Embedded Products B.V. Materiaalweg 4, 5681 RJ Best The Netherlands T: +31 (0) 499 33 69 69 E: [email protected] W: www.topic.nl Please consider the environment before printing this e-mail
PATCH v4 2/2 iio: adc: ti-ads1298: Add driver
Skeleton driver for the TI ADS1298 medical ADC. This device is typically used for ECG and similar measurements. Supports data acquisition at configurable scale and sampling frequency.
---
Changes in v4:
Explain rdata_xfer_busy better and remove post-decrement Reset assert explanation and add cansleep Additional style changes
Changes in v3:
Indentation fixups
Remove unused headers
Remove #define leftovers
Use devm_get_clk_optional_enabled
Use ilog2 instead of fls()-1
Magic "23" replaced
Explain the extra "0" in read/write register
use guard() from cleanup.h
use REGCACHE_MAPLE
Changes in v2:
Remove accidental "default y" in Kconfig
Indentation and similar cosmetic fixes
Magic numbers into constants
Short return paths in read_raw and write_raw
DMA buffer alignment
Bounce buffer is u32 instead of u8
Avoid races using claim_direct_mode
Check errors on all register accesses
Immediate SPI restart to reduce underruns
"name" is chip name, not unique
drivers/iio/adc/Kconfig | 11 + drivers/iio/adc/Makefile | 1 + drivers/iio/adc/ti-ads1298.c | 766 +++++++++++++++++++++++++++++++++++ 3 files changed, 778 insertions(+) create mode 100644 drivers/iio/adc/ti-ads1298.c
drivers/iio/adc/Kconfig +11 -0
@@ -1318,6 +1318,17 @@ config TI_ADS8688 This driver can also be built as a module. If so, the module will be called ti-ads8688. +config TI_ADS1298 + tristate "Texas Instruments ADS1298" + depends on SPI + select IIO_BUFFER + help + If you say yes here you get support for Texas Instruments ADS1298 + medical ADC chips + + This driver can also be built as a module. If so, the module will be + called ti-ads1298. + config TI_ADS124S08 tristate "Texas Instruments ADS124S08" depends on SPI
drivers/iio/adc/Makefile +1 -0
@@ -117,6 +117,7 @@ obj-$(CONFIG_TI_ADS7924) += ti-ads7924.o obj-$(CONFIG_TI_ADS7950) += ti-ads7950.o obj-$(CONFIG_TI_ADS8344) += ti-ads8344.o obj-$(CONFIG_TI_ADS8688) += ti-ads8688.o +obj-$(CONFIG_TI_ADS1298) += ti-ads1298.o obj-$(CONFIG_TI_ADS124S08) += ti-ads124s08.o obj-$(CONFIG_TI_ADS131E08) += ti-ads131e08.o obj-$(CONFIG_TI_AM335X_ADC) += ti_am335x_adc.o
drivers/iio/adc/ti-ads1298.c new file +766 -0
766 lines not on this page · raw message
Signature · 18 lines
2.34.1 Met vriendelijke groet / kind regards, Mike Looijmans System Expert TOPIC Embedded Products B.V. Materiaalweg 4, 5681 RJ Best The Netherlands T: +31 (0) 499 33 69 69 E: [email protected] W: www.topic.nl Please consider the environment before printing this e-mail
Jonathan Cameron
maintainerRe: [PATCH v4 2/2] iio: adc: ti-ads1298: Add driver
Quoted 6 lines · On Wed, 14 Feb 2024 07:37:36 +0100 Mike Looijmans <[email protected]>…
Skeleton driver for the TI ADS1298 medical ADC. This device is typically used for ECG and similar measurements. Supports data acquisition at configurable scale and sampling frequency.
Signed-off-by Mike Looijmans <[email protected]>
Hi Mike,
One final thing noticed on a (hopefully) last read through.
/sys/bus/iio:device0/name is going to read ads1298 whichever chip is detected.
Would be more useful to users if it identified the actual part given that is easily read from the ID register.
Jonathan
Quoted 18 lines
---
Changes in v4:
Explainrdata_xfer_busybetter and remove post-decrement Reset assert explanation and add cansleep Additional style changesChanges in v3:
Indentation fixups
Remove unused headers
Remove #define leftovers
Usedevm_get_clk_optional_enabled
Use ilog2 instead of fls()-1
Magic "23" replaced
Explain the extra "0" in read/write register
useguard()fromcleanup.h
useREGCACHE_MAPLE
Quoted 11 lines
Changes in v2:
Remove accidental "default y" inKconfig
Indentation and similar cosmetic fixes
Magic numbers into constants
Short return paths inread_rawandwrite_raw
DMA buffer alignment
Bounce buffer is u32 instead of u8
Avoid races usingclaim_direct_mode
Check errors on all register accesses
Immediate SPI restart to reduce underruns
"name" is chip name, not unique
I missed this until having a final read through but it's not the chip name in the driver currently - the name is always ads1298 despite there being a handy ID register that tells us what we actually have.
Quoted 19 lines
drivers/iio/adc/Kconfig | 11 + drivers/iio/adc/Makefile | 1 + drivers/iio/adc/ti-ads1298.c | 766 +++++++++++++++++++++++++++++++++++ 3 files changed, 778 insertions(+) create mode 100644 drivers/iio/adc/ti-ads1298.cdrivers/iio/adc/ti-ads1298.c new file +12
-0+ +static const char *ads1298_family_name (unsigned int id) +{ +switch (id &ADS1298_MASK_ID_FAMILY ) { +case ADS1298_ID_FAMILY_ADS129X : +return "ADS129x" ; +case ADS1298_ID_FAMILY_ADS129XR : +return "ADS129xR" ; +default : +return "(unknown)" ; + } +}
...
Quoted 2 lines
drivers/iio/adc/ti-ads1298.c new file +2
-0+static int ads1298_probe (struct spi_device *spi) +{
...
drivers/iio/adc/ti-ads1298.c line 704
Quoted 13 lines
drivers/iio/adc/ti-ads1298.c new file +13
-0+ + priv->tx_buffer[0 ] =ADS1298_CMD_RDATA ; + priv->rdata_xfer.tx_buf = priv->tx_buffer; + priv->rdata_xfer.rx_buf = priv->rx_buffer; + priv->rdata_xfer.len =ADS1298_SPI_RDATA_BUFFER_SIZE ; +/* Must keep CS low for 4 clocks */ + priv->rdata_xfer.delay.value =2 ; + priv->rdata_xfer.delay.unit =SPI_DELAY_UNIT_USECS ; +spi_message_init_with_transfers (&priv->rdata_msg, &priv->rdata_xfer,1 ); + priv->rdata_msg.complete = &ads1298_rdata_complete; + priv->rdata_msg.context = indio_dev; + + indio_dev->name =spi_get_device_id (spi)->name;
I was going to just tweak this whilst applying. Using the spi device id often ends up being fragile in the long term because of the split between the different ID tables and the mess that happens if fallback compatibles are in use and the spi IDs are missing (you will get a warning about this at runtime but it'll carry on anyway).
Easier to just hard code the name for now and when you have multiple devices supported, add this to a chip_info type structure.
Or we could make it support the more specific name given the detection above. Is there a reason to not do that given a more accurate name is easy to work out and may be useful to a user?
Jonathan
Re: [PATCH v4 2/2] iio: adc: ti-ads1298: Add driver
Quoted 11 lines · Jonathan Cameron
Quoted 6 lines · On Wed, 14 Feb 2024 07:37:36 +0100 Mike Looijmans <[email protected]>…
Skeleton driver for the TI ADS1298 medical ADC. This device is typically used for ECG and similar measurements. Supports data acquisition at configurable scale and sampling frequency.
Signed-off-by Mike Looijmans <[email protected]>Hi Mike,
Quoted 7 lines
One final thing noticed on a (hopefully) last read through.
/sys/bus/iio:device0/name is going to read ads1298 whichever chip is detected.
Would be more useful to users if it identified the actual part given that is easily read from the ID register.
Makes sense. So It would say "ads1296" or "ads1298r" for example. I guess we prefer all lower-case here.
Quoted 79 lines
Jonathan
Quoted 18 lines
---
Changes in v4:
Explainrdata_xfer_busybetter and remove post-decrement Reset assert explanation and add cansleep Additional style changesChanges in v3:
Indentation fixups
Remove unused headers
Remove #define leftovers
Usedevm_get_clk_optional_enabled
Use ilog2 instead of fls()-1
Magic "23" replaced
Explain the extra "0" in read/write register
useguard()fromcleanup.h
useREGCACHE_MAPLEQuoted 11 lines
Changes in v2:
Remove accidental "default y" inKconfig
Indentation and similar cosmetic fixes
Magic numbers into constants
Short return paths inread_rawandwrite_raw
DMA buffer alignment
Bounce buffer is u32 instead of u8
Avoid races usingclaim_direct_mode
Check errors on all register accesses
Immediate SPI restart to reduce underruns
"name" is chip name, not uniqueI missed this until having a final read through but it's not the chip name in the driver currently - the name is always ads1298 despite there being a handy ID register that tells us what we actually have.
Quoted 17 lines
drivers/iio/adc/Kconfig | 11 + drivers/iio/adc/Makefile | 1 + drivers/iio/adc/ti-ads1298.c | 766 +++++++++++++++++++++++++++++++++++ 3 files changed, 778 insertions(+)create mode 100644
drivers/iio/adc/ti-ads1298.cdrivers/iio/adc/ti-ads1298.c new file +12
-0+ +static const char *ads1298_family_name (unsigned int id) +{ +switch (id &ADS1298_MASK_ID_FAMILY ) { +case ADS1298_ID_FAMILY_ADS129X : +return "ADS129x" ; +case ADS1298_ID_FAMILY_ADS129XR : +return "ADS129xR" ; +default : +return "(unknown)" ; + } +}...
Quoted 2 lines
drivers/iio/adc/ti-ads1298.c new file +2
-0+static int ads1298_probe (struct spi_device *spi) +{...
drivers/iio/adc/ti-ads1298.c line 704
Quoted 13 lines
drivers/iio/adc/ti-ads1298.c new file +13
-0+ + priv->tx_buffer[0 ] =ADS1298_CMD_RDATA ; + priv->rdata_xfer.tx_buf = priv->tx_buffer; + priv->rdata_xfer.rx_buf = priv->rx_buffer; + priv->rdata_xfer.len =ADS1298_SPI_RDATA_BUFFER_SIZE ; +/* Must keep CS low for 4 clocks */ + priv->rdata_xfer.delay.value =2 ; + priv->rdata_xfer.delay.unit =SPI_DELAY_UNIT_USECS ; +spi_message_init_with_transfers (&priv->rdata_msg, &priv->rdata_xfer,1 ); + priv->rdata_msg.complete = &ads1298_rdata_complete; + priv->rdata_msg.context = indio_dev; + + indio_dev->name =spi_get_device_id (spi)->name;I was going to just tweak this whilst applying. Using the spi device id often ends up being fragile in the long term because of the split between the different ID tables and the mess that happens if fallback compatibles are in use and the spi IDs are missing (you will get a warning about this at runtime but it'll carry on anyway).
Quoted 6 lines
Easier to just hard code the name for now and when you have multiple devices supported, add this to a
chip_infotype structure.
Or we could make it support the more specific name given the detection above. Is there a reason to not do that given a more accurate name is easy to work out and may be useful to a user?
The only reason I tried to make the "name" unique is that IIO oscilloscope (ab)uses "name" as a unique identifier. That's something that ought to be fixed in IIO oscilloscope.
Giving the chip name would reveal the actual detected hardware, there's currently no other way for the user to find that out.
Signature · 10 lines
Mike Looijmans System Expert TOPIC Embedded Products B.V. Materiaalweg 4, 5681 RJ Best The Netherlands T: +31 (0) 499 33 69 69 E: [email protected] W: www.topic.nl
Re: [PATCH v4 2/2] iio: adc: ti-ads1298: Add driver
In reply to Jonathan CameronQuoted 11 lines · Jonathan Cameron
Quoted 6 lines · On Wed, 14 Feb 2024 07:37:36 +0100 Mike Looijmans <[email protected]>…
Skeleton driver for the TI ADS1298 medical ADC. This device is typically used for ECG and similar measurements. Supports data acquisition at configurable scale and sampling frequency.
Signed-off-by Mike Looijmans <[email protected]>Hi Mike,
Quoted 7 lines
One final thing noticed on a (hopefully) last read through.
/sys/bus/iio:device0/name is going to read ads1298 whichever chip is detected.
Would be more useful to users if it identified the actual part given that is easily read from the ID register.
Implemented it like that, the "name" now reflects the chip's information.
While at it, I also made the probe fail on invalid ID (tested by probing an empty SPI bus)
And also pass the channel count into the "num_channels" member, and adapted the SPI transaction, which should support the devices with 4 or 6 channels better.
I'll post a v5 soon, bit of testing first...
Signature · 10 lines
Mike Looijmans System Expert TOPIC Embedded Products B.V. Materiaalweg 4, 5681 RJ Best The Netherlands T: +31 (0) 499 33 69 69 E: [email protected] W: www.topic.nl