VT-d: use correct BDF for VF to search VT-d unit
PATCH v10 1/1 VT-d: use correct BDF for VF to search VT-d unit
When SR-IOV is enabled, 'Virtual Functions' of a 'Physical Function' are under the scope of the same VT-d unit as the 'Physical Function'. A 'Physical Function' can be a 'Traditional Function' or an ARI 'Extended Function'. And furthermore, 'Extended Functions' on an endpoint are under the scope of the same VT-d unit as the 'Traditional Functions' on the endpoint. To search VT-d unit for a VF, if its PF isn't an extended function, the BDF of PF should be used. Otherwise the BDF of a traditional function in the same device with the PF should be used.
Current code uses PCI_SLOT() to recognize an ARI 'Extended Funcion'. But it is conceptually wrong w/o checking whether PF is an extended function and would lead to match VFs of a RC integrated PF to a wrong VT-d unit.
This patch overrides VF 'is_extfn' field and uses this field to indicate whether the PF of this VF is an extended function. The field helps to use correct BDF to search VT-d unit.
---
v10:
- move setting vf's is_extfn closer to the place where we set other fields.
- reverse the conditional expression in acpi_find_matched_drhd_unit()
v9:
- check 'is_virtfn' first in pci_add_device() to avoid potential error if linux side sets VF's 'is_extfn'
- comments changes to make it clear that we use VF's 'is_extfn' intentionally otherwise the patch seems like a workaround.
v8:
- use "conceptually wrong", instead of "a corner case" in commit message
- check 'is_virtfn' first in acpi_find_matched_drhd_unit()
v7:
- Drop Eric's tested-by
- Change commit message to be clearer
- Re-use VF's is_extfn field
- access PF's is_extfn field in locked area
--- xen/drivers/passthrough/pci.c | 19 +++++++++++++++---- xen/drivers/passthrough/vtd/dmar.c | 12 ++++++------ xen/include/xen/pci.h | 4 ++++ 3 files changed, 25 insertions(+), 10 deletions(-)
xen/drivers/passthrough/pci.c +15 -4
@@ -599,21 +599,24 @@ int pci_add_device(u16 seg, u8 bus, u8 devfn,unsigned int slot =PCI_SLOT (devfn), func =PCI_FUNC (devfn);const char *pdev_type;int ret; +bool pf_is_extfn = false; -if (!info) +if ( !info ) pdev_type ="device" ; -else if (info->is_extfn) - pdev_type ="extended function" ; -else if (info->is_virtfn) +else if ( info->is_virtfn ) {pcidevs_lock (); pdev =pci_get_pdev (seg, info->physfn.bus, info->physfn.devfn); +if ( pdev ) + pf_is_extfn = pdev->info.is_extfn;pcidevs_unlock ();if ( !pdev )pci_add_device (seg, info->physfn.bus, info->physfn.devfn,NULL , node); pdev_type ="virtual function" ; } +else if ( info->is_extfn ) + pdev_type ="extended function" ;else { info =NULL ;
@@ -637,7 +640,15 @@ int pci_add_device(u16 seg, u8 bus, u8 devfn, pdev->node = node;if ( info ) + { pdev->info = *info; +/* +* VF's 'is_extfn' field is used to indicate whether its PF is an +* extended function. +*/ +if ( pdev->info.is_virtfn ) + pdev->info.is_extfn = pf_is_extfn; + }else if ( !pdev->vf_rlen[0 ] ) { unsigned int pos = pci_find_ext_capability(seg, bus, devfn,
xen/drivers/passthrough/vtd/dmar.c +6 -6
@@ -211,15 +211,15 @@ struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev)if ( pdev ==NULL )return NULL ; -if ( pdev->info.is_extfn ) +if ( pdev->info.is_virtfn ) { - bus = pdev->bus; - devfn =0 ; + bus = pdev->info.physfn.bus; + devfn = (!pdev->info.is_extfn) ? pdev->info.physfn.devfn :0 ; } -else if ( pdev->info.is_virtfn ) +else if ( pdev->info.is_extfn ) { - bus = pdev->info.physfn.bus; - devfn =PCI_SLOT (pdev->info.physfn.devfn) ?0 : pdev->info.physfn.devfn; + bus = pdev->bus; + devfn =0 ; }else {
xen/include/xen/pci.h +4 -0
@@ -39,6 +39,10 @@#define PCI_SBDF3 (s,b,df) ((((s) & 0xffff) << 16) | PCI_BDF2(b, df))struct pci_dev_info { +/* +* VF's 'is_extfn' field is used to indicate whether its PF is an extended +* function. +*/ bool_t is_extfn;bool_t is_virtfn;struct {
Signature · 7 lines
1.8.3.1 _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Quoted 18 lines
From: Gao, Chao
Sent: Monday, August 28, 2017 10:42 AMWhen SR-IOV is enabled, 'Virtual Functions' of a 'Physical Function' are under the scope of the same VT-d unit as the 'Physical Function'. A 'Physical Function' can be a 'Traditional Function' or an ARI 'Extended Function'. And furthermore, 'Extended Functions' on an endpoint are under the scope of the same VT-d unit as the 'Traditional Functions' on the endpoint. To search VT-d unit for a VF, if its PF isn't an extended function, the BDF of PF should be used. Otherwise the BDF of a traditional function in the same device with the PF should be used.
Current code uses
PCI_SLOT()to recognize an ARI 'Extended Funcion'. But it is conceptually wrong w/o checking whether PF is an extended function and would lead to match VFs of a RC integrated PF to a wrong VT-d unit.
Quoted 6 lines
This patch overrides VF '
is_extfn' field and uses this field to indicate whether the PF of this VF is an extended function. The field helps to use correct BDF to search VT-d unit.Reported-by Crawford, Eric R <[email protected]>Signed-off-by Chao Gao <[email protected]>
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 28.08.17 at 04:42, <[email protected]> wrote:
When SR-IOV is enabled, 'Virtual Functions' of a 'Physical Function' are under the scope of the same VT-d unit as the 'Physical Function'. A 'Physical Function' can be a 'Traditional Function' or an ARI 'Extended Function'. And furthermore, 'Extended Functions' on an endpoint are under the scope of the same VT-d unit as the 'Traditional Functions' on the endpoint. To search VT-d unit for a VF, if its PF isn't an extended function, the BDF of PF should be used. Otherwise the BDF of a traditional function in the same device with the PF should be used.
Current code uses
PCI_SLOT()to recognize an ARI 'Extended Funcion'. But it is conceptually wrong w/o checking whether PF is an extended function and would lead to match VFs of a RC integrated PF to a wrong VT-d unit.
Quoted 6 lines
This patch overrides VF '
is_extfn' field and uses this field to indicate whether the PF of this VF is an extended function. The field helps to use correct BDF to search VT-d unit.Reported-by Crawford, Eric R <[email protected]>Signed-off-by Chao Gao <[email protected]>
albeit ...
xen/drivers/passthrough/vtd/dmar.c struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev) · line 217
Quoted 13 lines
xen/drivers/passthrough/vtd/dmar.c +3
-3@@ -211,15 +211,15 @@ struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev)if ( pdev ==NULL )return NULL ; -if ( pdev->info.is_extfn ) +if ( pdev->info.is_virtfn ) { - bus = pdev->bus; - devfn =0 ; + bus = pdev->info.physfn.bus; + devfn = (!pdev->info.is_extfn) ? pdev->info.physfn.devfn :0 ;
... if I end up committing this and if I don't forget, I'll likely take the liberty to remove the pointless parentheses here.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Quoted 32 lines · Jan Beulich
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 28.08.17 at 04:42, <[email protected]> wrote:
When SR-IOV is enabled, 'Virtual Functions' of a 'Physical Function' are under the scope of the same VT-d unit as the 'Physical Function'. A 'Physical Function' can be a 'Traditional Function' or an ARI 'Extended Function'. And furthermore, 'Extended Functions' on an endpoint are under the scope of the same VT-d unit as the 'Traditional Functions' on the endpoint. To search VT-d unit for a VF, if its PF isn't an extended function, the BDF of PF should be used. Otherwise the BDF of a traditional function in the same device with the PF should be used.
Current code uses
PCI_SLOT()to recognize an ARI 'Extended Funcion'. But it is conceptually wrong w/o checking whether PF is an extended function and would lead to match VFs of a RC integrated PF to a wrong VT-d unit.Quoted 6 lines
This patch overrides VF '
is_extfn' field and uses this field to indicate whether the PF of this VF is an extended function. The field helps to use correct BDF to search VT-d unit.Reported-by Crawford, Eric R <[email protected]>Signed-off-by Chao Gao <[email protected]>Acked-by Jan Beulich <[email protected]>albeit ...
Quoted 6 lines
xen/drivers/passthrough/vtd/dmar.c +0
-0@@ -211,15 +211,15 @@ struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev)if ( pdev ==NULL )return NULL ;
Quoted 11 lines
xen/drivers/passthrough/vtd/dmar.c struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev) · line 217
Quoted 7 lines
xen/drivers/passthrough/vtd/dmar.c +3
-3-if ( pdev->info.is_extfn ) +if ( pdev->info.is_virtfn ) { - bus = pdev->bus; - devfn =0 ; + bus = pdev->info.physfn.bus; + devfn = (!pdev->info.is_extfn) ? pdev->info.physfn.devfn :0 ;... if I end up committing this and if I don't forget, I'll likely take the liberty to remove the pointless parentheses here.
Hi, Eric.
Could you test this patch again and give your Tested-by if it fixes the problem you reported?
Thanks
Chao
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Crawford, Eric R
Tested-bySorry for the delay, it looks like this patch resolves the issue.
-Eric
-----Original Message-----
From: Gao, Chao
Sent: Monday, August 28, 2017 12:27 AM
To: Crawford, Eric R <[email protected]>
Cc: Andrew Cooper <[email protected]>; Roger Pau Monné <[email protected]>; Wei Liu <[email protected]>; George Dunlap <[email protected]>; Ian Jackson <[email protected]>; Crawford, Eric R <[email protected]>; Tian, Kevin <[email protected]>; Stefano Stabellini <[email protected]>; [email protected]; Konrad Rzeszutek Wilk <[email protected]>; Tim Deegan <[email protected]>; Jan Beulich <[email protected]>
Subject: Re: [PATCH v10] VT-d: use correct BDF for VF to search VT-d unit
Quoted 31 lines · Jan Beulich
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 28.08.17 at 04:42, <[email protected]> wrote:
When SR-IOV is enabled, 'Virtual Functions' of a 'Physical Function' are under the scope of the same VT-d unit as the 'Physical Function'. A 'Physical Function' can be a 'Traditional Function' or an ARI 'Extended Function'. And furthermore, 'Extended Functions' on an endpoint are under the scope of the same VT-d unit as the 'Traditional Functions' on the endpoint. To search VT-d unit for a VF, if its PF isn't an extended function, the BDF of PF should be used. Otherwise the BDF of a traditional function in the same device with the PF should be used.
Current code uses
PCI_SLOT()to recognize an ARI 'Extended Funcion'. But it is conceptually wrong w/o checking whether PF is an extended function and would lead to match VFs of a RC integrated PF to a wrong VT-d unit.Quoted 6 lines
This patch overrides VF '
is_extfn' field and uses this field to indicate whether the PF of this VF is an extended function. The field helps to use correct BDF to search VT-d unit.Reported-by Crawford, Eric R <[email protected]>Signed-off-by Chao Gao <[email protected]>Quoted 6 lines
xen/drivers/passthrough/vtd/dmar.c +0
-0@@ -211,15 +211,15 @@ struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev)if ( pdev ==NULL )return NULL ;
Quoted 12 lines
xen/drivers/passthrough/vtd/dmar.c struct acpi_drhd_unit *acpi_find_matched_drhd_unit(const struct pci_dev *pdev)
Quoted 8 lines
xen/drivers/passthrough/vtd/dmar.c +4
-3-if ( pdev->info.is_extfn ) +if ( pdev->info.is_virtfn ) { - bus = pdev->bus; - devfn =0 ; + bus = pdev->info.physfn.bus; + devfn = (!pdev->info.is_extfn) ? pdev->info.physfn.devfn : +0 ;... if I end up committing this and if I don't forget, I'll likely take the liberty to remove the pointless parentheses here.
Hi, Eric.
Could you test this patch again and give your Tested-by if it fixes the problem you reported?
Thanks
Chao