Skip to contentSkip to conversation

uvcvideo: zero seq number when disabling stream

PATCH RESEND In review Hans Yang 3 participants 6 messages Sep 15, 2017 – Aug 6, 2018

Subsystems (2)
lore
Share & tools
lore

Hans Yang

author
#0 lore raw

PATCH RESEND 1/1 uvcvideo: zero seq number when disabling stream

For bulk-based devices, when disabling the video stream, in addition to issue CLEAR_FEATURE(HALT), it is better to set alternate setting 0 as well or the sequnce number in host side will probably not reset to zero.

Then in next time video stream start, the device will expect host starts packet from 0 sequence number but host actually continue the sequence number from last transaction and this causes transaction errors.

This commit fixes this by adding set alternate setting 0 back as what isoch-based devices do.

Below error message will also be eliminated for some devices:
uvcvideo: Non-zero status (-71) in video completion handler.

---
 drivers/media/usb/uvc/uvc_video.c | 5 ++---
 1 file changed, 2 insertions(+), 3 deletions(-)
drivers/media/usb/uvc/uvc_video.c +2 -3
index fb86d6af398d..ad80c2a6da6a 100644
@@ -1862,10 +1862,9 @@ int uvc_video_enable(struct uvc_streaming *stream, int enable)
 
 	if (!enable) {
 		uvc_uninit_video(stream, 1);
-		if (stream->intf->num_altsetting > 1) {
-			usb_set_interface(stream->dev->udev,
+		usb_set_interface(stream->dev->udev,
 					  stream->intfnum, 0);
-		} else {
+		if (stream->intf->num_altsetting == 1) {
 			/* UVC doesn't specify how to inform a bulk-based device
 			 * when the video stream is stopped. Windows sends a
 			 * CLEAR_FEATURE(HALT) request to the video streaming
Signature · 1 line
2.1.4
maintainer
#1 lore raw

Hi Hans,

(CC'ing Guennadi Liakhovetski)

Thank you for the patch.

Quoted 4 lines · On Friday, 15 September 2017 09:27:51 EEST Hans Yang wrote:

For bulk-based devices, when disabling the video stream, in addition to issue CLEAR_FEATURE(HALT), it is better to set alternate setting 0 as well or the sequnce number in host side will probably not reset to zero.

The USB 2.0 specificatin states in the description of the SET_INTERFACE request that "If a device only supports a default setting for the specified interface, then a STALL may be returned in the Status stage of the request".

The Linux implementation of usb_set_interface() deals with this by handling STALL conditions and manually clearing HALT for all endpoints in the interface, but I'm still concerned that this change could break existing bulk- based cameras. Do you know what other operating systems do when disabling the stream on bulk cameras ? According to a comment in the driver Windows calls CLEAR_FEATURE(HALT), but the situation might have changed since that was tested.

Guennadi, how do your bulk-based cameras handle this ?

Quoted 4 lines

Then in next time video stream start, the device will expect host starts packet from 0 sequence number but host actually continue the sequence number from last transaction and this causes transaction errors.

Do you mean the DATA0/DATA1 toggle ? Why does the host continue toggling the PID from the last transation ? The usb_clear_halt() function calls usb_reset_endpoint() which should reset the DATA PID toggle.

Quoted 29 lines

This commit fixes this by adding set alternate setting 0 back as what isoch-based devices do.

Below error message will also be eliminated for some devices:
uvcvideo: Non-zero status (-71) in video completion handler.

---
 drivers/media/usb/uvc/uvc_video.c | 5 ++---
 1 file changed, 2 insertions(+), 3 deletions(-)
(quoted diff) +0 -0

b/drivers/media/usb/uvc/uvc_video.c index fb86d6af398d..ad80c2a6da6a 100644

drivers/media/usb/uvc/uvc_video.c +2 -3
@@ -1862,10 +1862,9 @@ int uvc_video_enable(struct uvc_streaming *stream,
 int enable)
 
 	if (!enable) {
 		uvc_uninit_video(stream, 1);
-		if (stream->intf->num_altsetting > 1) {
-			usb_set_interface(stream->dev->udev,
+		usb_set_interface(stream->dev->udev,
 					  stream->intfnum, 0);
-		} else {
+		if (stream->intf->num_altsetting == 1) {
 			/* UVC doesn't specify how to inform a bulk-based device
 			 * when the video stream is stopped. Windows sends a

* CLEAR_FEATURE(HALT) request to the video streaming

Signature · 3 lines
Regards,

Laurent Pinchart
#2 lore raw

Hi Laurent,

Quoted 24 lines · Laurent Pinchart

Hi Hans,

(CC'ing Guennadi Liakhovetski)

Thank you for the patch.

Quoted 4 lines · On Friday, 15 September 2017 09:27:51 EEST Hans Yang wrote:

For bulk-based devices, when disabling the video stream, in addition to issue CLEAR_FEATURE(HALT), it is better to set alternate setting 0 as well or the sequnce number in host side will probably not reset to zero.

The USB 2.0 specificatin states in the description of the SET_INTERFACE request that "If a device only supports a default setting for the specified interface, then a STALL may be returned in the Status stage of the request".

The Linux implementation of usb_set_interface() deals with this by handling STALL conditions and manually clearing HALT for all endpoints in the interface, but I'm still concerned that this change could break existing bulk- based cameras. Do you know what other operating systems do when disabling the stream on bulk cameras ? According to a comment in the driver Windows calls CLEAR_FEATURE(HALT), but the situation might have changed since that was tested.

Quoted 1 line

Guennadi, how do your bulk-based cameras handle this ?

I don't know what design decisions are implemented there, but I tested a couple of cameras for sending a STREAMOFF after a few captured buffers, sleeping for a couple of seconds, requeuing buffers, sending STREAMON and capturing a few more - that seems to have worked. "Seems" because I only used a modified version of capture-example, I haven't checked buffer contents.

BTW, Hans, may I ask - what cameras did you use?

Thanks
Guennadi

Quoted 44 lines
Quoted 4 lines

Then in next time video stream start, the device will expect host starts packet from 0 sequence number but host actually continue the sequence number from last transaction and this causes transaction errors.

Do you mean the DATA0/DATA1 toggle ? Why does the host continue toggling the PID from the last transation ? The usb_clear_halt() function calls usb_reset_endpoint() which should reset the DATA PID toggle.

Quoted 29 lines

This commit fixes this by adding set alternate setting 0 back as what isoch-based devices do.

Below error message will also be eliminated for some devices:
uvcvideo: Non-zero status (-71) in video completion handler.

---
 drivers/media/usb/uvc/uvc_video.c | 5 ++---
 1 file changed, 2 insertions(+), 3 deletions(-)
(quoted diff) +0 -0

b/drivers/media/usb/uvc/uvc_video.c index fb86d6af398d..ad80c2a6da6a 100644

drivers/media/usb/uvc/uvc_video.c +2 -3
@@ -1862,10 +1862,9 @@ int uvc_video_enable(struct uvc_streaming *stream,
 int enable)
 
 	if (!enable) {
 		uvc_uninit_video(stream, 1);
-		if (stream->intf->num_altsetting > 1) {
-			usb_set_interface(stream->dev->udev,
+		usb_set_interface(stream->dev->udev,
 					  stream->intfnum, 0);
-		} else {
+		if (stream->intf->num_altsetting == 1) {
 			/* UVC doesn't specify how to inform a bulk-based device
 			 * when the video stream is stopped. Windows sends a

* CLEAR_FEATURE(HALT) request to the video streaming

Signature · 3 lines
Regards,

Laurent Pinchart
author
#3 lore raw

Hi Laurent and Guennadi,

Quoted 27 lines · Guennadi Liakhovetski

Hi Laurent,

Quoted 23 lines · Laurent Pinchart

Hi Hans,

(CC'ing Guennadi Liakhovetski)

Thank you for the patch.

Quoted 4 lines · On Friday, 15 September 2017 09:27:51 EEST Hans Yang wrote:

For bulk-based devices, when disabling the video stream, in addition to issue CLEAR_FEATURE(HALT), it is better to set alternate setting 0 as well or the sequnce number in host side will probably not reset to zero.

The USB 2.0 specificatin states in the description of the SET_INTERFACE request that "If a device only supports a default setting for the specified interface, then a STALL may be returned in the Status stage of the request".

The Linux implementation of usb_set_interface() deals with this by handling STALL conditions and manually clearing HALT for all endpoints in the interface, but I'm still concerned that this change could break existing bulk- based cameras. Do you know what other operating systems do when disabling the stream on bulk cameras ? According to a comment in the driver Windows calls CLEAR_FEATURE(HALT), but the situation might have changed since that was tested.

Sorry I did not mention that it is about SS bulk-based cameras using sequence number technique.
From my observations, invoking usb_clear_halt() will reset the endpoint in the device side via CLEAR_FEATURE(HALT) and reset the sequence number as well; however usb_reset_endpoint() does not reset the host side endpoint with xhci driver, then the sequence number will mismatch in next time stream enable.
I can always observe this through a bus analyzer on Linux implementation whatever X86 or ARM based. This is not observed on the Windows.

Quoted 11 lines
Quoted 2 lines

Guennadi, how do your bulk-based cameras handle this ?

I don't know what design decisions are implemented there, but I tested a couple of cameras for sending a STREAMOFF after a few captured buffers, sleeping for a couple of seconds, requeuing buffers, sending STREAMON and capturing a few more - that seems to have worked. "Seems" because I only used a modified version of capture-example, I haven't checked buffer contents.

BTW, Hans, may I ask - what cameras did you use?

I have three SS bulk-based cameras as follows:
e-con Systems See3CAM_CU130 (2560:c1d0)
Leopard ZED (2b03:f580)
Intel(R) RealSense(TM) Camera SR300 (8086:0aa5)

I can observe the same issue on all above;
besides, to reproduce issue do not let the camera enter suspend because it will *help* to reset the sequence number through usb_set_interface(0).

Quoted 48 lines

Thanks
Guennadi

Quoted 44 lines
Quoted 4 lines

Then in next time video stream start, the device will expect host starts packet from 0 sequence number but host actually continue the sequence number from last transaction and this causes transaction errors.

Do you mean the DATA0/DATA1 toggle ? Why does the host continue toggling the PID from the last transation ? The usb_clear_halt() function calls usb_reset_endpoint() which should reset the DATA PID toggle.

Quoted 29 lines

This commit fixes this by adding set alternate setting 0 back as what isoch-based devices do.

Below error message will also be eliminated for some devices:
uvcvideo: Non-zero status (-71) in video completion handler.

---
  drivers/media/usb/uvc/uvc_video.c | 5 ++---
  1 file changed, 2 insertions(+), 3 deletions(-)
(quoted diff) +0 -0

b/drivers/media/usb/uvc/uvc_video.c index fb86d6af398d..ad80c2a6da6a 100644

drivers/media/usb/uvc/uvc_video.c +2 -3
@@ -1862,10 +1862,9 @@ int uvc_video_enable(struct uvc_streaming *stream,
 int enable)
 
  	if (!enable) {
  		uvc_uninit_video(stream, 1);
-		if (stream->intf->num_altsetting > 1) {
-			usb_set_interface(stream->dev->udev,
+		usb_set_interface(stream->dev->udev,
  					  stream->intfnum, 0);
-		} else {
+		if (stream->intf->num_altsetting == 1) {
  			/* UVC doesn't specify how to inform a bulk-based device
  			 * when the video stream is stopped. Windows sends a

* CLEAR_FEATURE(HALT) request to the video streaming

Signature · 3 lines
Regards,

Laurent Pinchart

Regards,
Hans Yang
--nvpublic--

maintainer
#4 lore raw

Hi Hans,

Quoted 22 lines · On Thursday, 19 October 2017 10:23:06 EEST Hans Yang wrote:
Quoted 13 lines · Guennadi Liakhovetski
Quoted 12 lines · Laurent Pinchart
Quoted 4 lines · On Friday, 15 September 2017 09:27:51 EEST Hans Yang wrote:

For bulk-based devices, when disabling the video stream, in addition to issue CLEAR_FEATURE(HALT), it is better to set alternate setting 0 as well or the sequnce number in host side will probably not reset to zero.

The USB 2.0 specificatin states in the description of the SET_INTERFACE request that "If a device only supports a default setting for the specified interface, then a STALL may be returned in the Status stage of the request".

Quoted 7 lines
Quoted 7 lines

The Linux implementation of usb_set_interface() deals with this by handling STALL conditions and manually clearing HALT for all endpoints in the interface, but I'm still concerned that this change could break existing bulk- based cameras. Do you know what other operating systems do when disabling the stream on bulk cameras ? According to a comment in the driver Windows calls CLEAR_FEATURE(HALT), but the situation might have changed since that was tested.

Quoted 10 lines

Sorry I did not mention that it is about SS bulk-based cameras using sequence number technique.
From my observations, invoking usb_clear_halt() will reset the endpoint
in the device side via CLEAR_FEATURE(HALT)
and reset the sequence number as well; however usb_reset_endpoint() does not reset the host side endpoint with xhci driver,
then the sequence number will mismatch in next time stream enable. I can always observe this through a bus analyzer on Linux implementation whatever X86 or ARM based.
This is not observed on the Windows.

According to the USB 3.0 specification, section 9.4.5 ("Get Status"),

"Regardless of whether an endpoint has the Halt feature set, a ClearFeature(ENDPOINT_HALT) request always results in the data sequence being reinitialized to zero, and if Streams are enabled, the Stream State Machine shall be reinitialized to the Disabled state."

If Linux doesn't reset the sequence number when issuing a CLEAR_FEATURE(HALT), isn't it a Linux USB stack bug that should be fixed in the USB core ?

Quoted 60 lines
Quoted 10 lines
Quoted 1 line

Guennadi, how do your bulk-based cameras handle this ?

I don't know what design decisions are implemented there, but I tested a couple of cameras for sending a STREAMOFF after a few captured buffers, sleeping for a couple of seconds, requeuing buffers, sending STREAMON and capturing a few more - that seems to have worked. "Seems" because I only used a modified version of capture-example, I haven't checked buffer contents.

BTW, Hans, may I ask - what cameras did you use?

I have three SS bulk-based cameras as follows:
e-con Systems See3CAM_CU130 (2560:c1d0)
Leopard ZED (2b03:f580)
Intel(R) RealSense(TM) Camera SR300 (8086:0aa5)

I can observe the same issue on all above;
besides, to reproduce issue do not let the camera enter suspend because it will *help* to reset the sequence number through usb_set_interface(0).

Quoted 40 lines
Quoted 40 lines
Quoted 4 lines

Then in next time video stream start, the device will expect host starts packet from 0 sequence number but host actually continue the sequence number from last transaction and this causes transaction errors.

Do you mean the DATA0/DATA1 toggle ? Why does the host continue toggling the PID from the last transation ? The usb_clear_halt() function calls usb_reset_endpoint() which should reset the DATA PID toggle.

Quoted 31 lines

This commit fixes this by adding set alternate setting 0 back as what isoch-based devices do.

Below error message will also be eliminated for some devices:
uvcvideo: Non-zero status (-71) in video completion handler.

---

  drivers/media/usb/uvc/uvc_video.c | 5 ++---
  1 file changed, 2 insertions(+), 3 deletions(-)
(quoted diff) +0 -0

b/drivers/media/usb/uvc/uvc_video.c index fb86d6af398d..ad80c2a6da6a 100644

drivers/media/usb/uvc/uvc_video.c +2 -3
@@ -1862,10 +1862,9 @@ int uvc_video_enable(struct uvc_streaming
 *stream, int enable)
 
  	if (!enable) {
  		uvc_uninit_video(stream, 1);
-		if (stream->intf->num_altsetting > 1) {
-			usb_set_interface(stream->dev->udev,
+		usb_set_interface(stream->dev->udev,
  					  stream->intfnum, 0);
-		} else {
+		if (stream->intf->num_altsetting == 1) {
  			/* UVC doesn't specify how to inform a bulk-based device
  			 * when the video stream is stopped. Windows sends a

* CLEAR_FEATURE(HALT) request to the video streaming

Signature · 3 lines
Regards,

Laurent Pinchart
maintainer
#5 lore raw

Hi Hans,

(CC'ing the linux-usb mailing list)

Quoted 25 lines · On Thursday, 19 October 2017 15:03:34 EEST Laurent Pinchart wrote:
Quoted 24 lines · On Thursday, 19 October 2017 10:23:06 EEST Hans Yang wrote:
Quoted 12 lines · Guennadi Liakhovetski
Quoted 11 lines · Laurent Pinchart
Quoted 4 lines · On Friday, 15 September 2017 09:27:51 EEST Hans Yang wrote:

For bulk-based devices, when disabling the video stream, in addition to issue CLEAR_FEATURE(HALT), it is better to set alternate setting 0 as well or the sequnce number in host side will probably not reset to zero.

The USB 2.0 specificatin states in the description of the SET_INTERFACE request that "If a device only supports a default setting for the specified interface, then a STALL may be returned in the Status stage of the request".

Quoted 7 lines
Quoted 7 lines

The Linux implementation of usb_set_interface() deals with this by handling STALL conditions and manually clearing HALT for all endpoints in the interface, but I'm still concerned that this change could break existing bulk- based cameras. Do you know what other operating systems do when disabling the stream on bulk cameras ? According to a comment in the driver Windows calls CLEAR_FEATURE(HALT), but the situation might have changed since that was tested.

Sorry I did not mention that it is about SS bulk-based cameras using sequence number technique.

Quoted 8 lines
Quoted 8 lines

From my observations, invoking usb_clear_halt() will reset the endpoint in the device side via CLEAR_FEATURE(HALT)
and reset the sequence number as well; however usb_reset_endpoint() does not reset the host side endpoint with xhci driver,
then the sequence number will mismatch in next time stream enable. I can always observe this through a bus analyzer on Linux implementation whatever X86 or ARM based.
This is not observed on the Windows.

Do your USB analyser traces show whether Windows sends a SET_INTERFACE(0) request when stopping the stream for bulk-based devices ?

Quoted 10 lines

According to the USB 3.0 specification, section 9.4.5 ("Get Status"),

"Regardless of whether an endpoint has the Halt feature set, a ClearFeature(ENDPOINT_HALT) request always results in the data sequence being reinitialized to zero, and if Streams are enabled, the Stream State Machine shall be reinitialized to the Disabled state."

If Linux doesn't reset the sequence number when issuing a CLEAR_FEATURE(HALT), isn't it a Linux USB stack bug that should be fixed in the USB core ?

Do you have any update on whether you would consider this to be a Linux USB stack issue or a uvcvideo driver issue ?

Quoted 61 lines
Quoted 61 lines
Quoted 10 lines
Quoted 1 line

Guennadi, how do your bulk-based cameras handle this ?

I don't know what design decisions are implemented there, but I tested a couple of cameras for sending a STREAMOFF after a few captured buffers, sleeping for a couple of seconds, requeuing buffers, sending STREAMON and capturing a few more - that seems to have worked. "Seems" because I only used a modified version of capture-example, I haven't checked buffer contents.

BTW, Hans, may I ask - what cameras did you use?

I have three SS bulk-based cameras as follows:
e-con Systems See3CAM_CU130 (2560:c1d0)
Leopard ZED (2b03:f580)
Intel(R) RealSense(TM) Camera SR300 (8086:0aa5)

I can observe the same issue on all above;
besides, to reproduce issue do not let the camera enter suspend because it will *help* to reset the sequence number through usb_set_interface(0).

Quoted 41 lines
Quoted 41 lines
Quoted 4 lines

Then in next time video stream start, the device will expect host starts packet from 0 sequence number but host actually continue the sequence number from last transaction and this causes transaction errors.

Do you mean the DATA0/DATA1 toggle ? Why does the host continue toggling the PID from the last transation ? The usb_clear_halt() function calls usb_reset_endpoint() which should reset the DATA PID toggle.

Quoted 31 lines

This commit fixes this by adding set alternate setting 0 back as what isoch-based devices do.

Below error message will also be eliminated for some devices:
uvcvideo: Non-zero status (-71) in video completion handler.

---

  drivers/media/usb/uvc/uvc_video.c | 5 ++---
  1 file changed, 2 insertions(+), 3 deletions(-)
(quoted diff) +0 -0

b/drivers/media/usb/uvc/uvc_video.c index fb86d6af398d..ad80c2a6da6a 100644

drivers/media/usb/uvc/uvc_video.c +2 -3
@@ -1862,10 +1862,9 @@ int uvc_video_enable(struct uvc_streaming
 *stream, int enable)
  	if (!enable) {
  		uvc_uninit_video(stream, 1);
 
-		if (stream->intf->num_altsetting > 1) {
-			usb_set_interface(stream->dev->udev,
+		usb_set_interface(stream->dev->udev,
  					  stream->intfnum, 0);
-		} else {
+		if (stream->intf->num_altsetting == 1) {
  			/* UVC doesn't specify how to inform a bulk-based device
  			 * when the video stream is stopped. Windows sends a

* CLEAR_FEATURE(HALT) request to the video streaming

Signature · 3 lines
Regards,

Laurent Pinchart