cpufreq(-dt) with two clocks but one regulator
Heiko Stuebner
maintainerHi Viresh,
if possible I'd like a pointer in the right direction for the following situation:
The rk3368 has two cpu clusters of 4 Cortex-A53 cores each, with separate clock supplies but sharing its supplying regulator. It looks like it was originally meant for some switched big-little system, with the little cluster maxing out at 1.2GHz while the big cluster can reach 1.5GHz.
This of course fails miserably with current cpufreq, as the two sets of operating points fight over control of the regulator and after talking with real-life users of the soc it seems most desireable to have all 8 cores available at 1.2GHz than only 4 at 1.5GHz max.
But as the clock seems to be bound to the opp table itself simply sharing the table of course also doesn't work, as only the first clock would be set.
I'm currently only seeing somehow hacky options to solve this, so if you have some direction on how to solve something like this I would be really grateful :-)
Thanks
Heiko
Hi Heiko,
Quoted 7 lines · Heiko Stuebner
Hi Viresh,
if possible I'd like a pointer in the right direction for the following situation:
The rk3368 has two cpu clusters of 4 Cortex-A53 cores each, with separate clock supplies
These must be represented by two cpufreq policies no matter what. That's how the hardware is.
Quoted 1 line
but sharing its supplying regulator.
That should be fine.
Quoted 3 lines
It looks like it was
originally meant for some switched big-little system, with the little cluster maxing out at 1.2GHz while the big cluster can reach 1.5GHz.
So, right now all can go to 1.5 GHz?
Quoted 2 lines
This of course fails miserably with current cpufreq, as the two sets of operating points fight over control of the regulator
Why so? I am not sure I understood this part yet. Both the clusters should try to set their constraints and the intersection should be selected by the regulator core? Can you share the OPP tables, so that we can discuss more.
Quoted 3 lines
and after talking
with real-life users of the soc it seems most desireable to have all 8 cores available at 1.2GHz than only 4 at 1.5GHz max.
What's wrong with all at 1.5 GHz?
Quoted 2 lines
But as the clock seems to be bound to the opp table itself simply sharing the table of course also doesn't work
No, the OPP table shouldn't be shared at all. Its something to be shared by a cluster only.
Quoted 6 lines
as only the first clock would be set.
I'm currently only seeing somehow hacky options to solve this, so if you have some direction on how to solve something like this I would be really grateful :-)
I think it should just work, but otherwise as well we can update some framework to make it work. Lets just get on the same line first and help me understand it better.
Signature · 1 line
viresh
Heiko Stuebner
maintainerHi Viresh,
Am Sonntag, 17. September 2017, 18:24:16 CEST schrieb Viresh Kumar:
Quoted 12 lines · Heiko Stuebner
Quoted 5 lines
if possible I'd like a pointer in the right direction for the following situation:
The rk3368 has two cpu clusters of 4 Cortex-A53 cores each, with separate clock supplies
These must be represented by two cpufreq policies no matter what. That's how the hardware is.
Quoted 1 line
but sharing its supplying regulator.
Quoted 7 lines
That should be fine.
Quoted 3 lines
It looks like it was
originally meant for some switched big-little system, with the little cluster maxing out at 1.2GHz while the big cluster can reach 1.5GHz.So, right now all can go to 1.5 GHz?
No, the little cluster of 4 cores is rated at 1.2GHz max, while the big cluster of 4 cores is rated at 1.5Ghz
Quoted 6 lines
Quoted 2 lines
This of course fails miserably with current cpufreq, as the two sets of operating points fight over control of the regulator
Why so? I am not sure I understood this part yet. Both the clusters should try to set their constraints and the intersection should be selected by the regulator core? Can you share the OPP tables, so that we can discuss more.
Current submitted OPPs can be found at
https://patchwork.kernel.org/patch/9908519/
There were still issues with higher frequencies, so they don't list the 1.2 or 1.5GHz yet.
But opp sets pretty tight constraints. I.e. OPPs have of course one preferred voltage, so you end up with u_volt_min = u_volt_max for each operating point, thus the regulator also gets set in this way, removing any intersection and thus making the regulator framework fail to set a voltage for one of the clusters.
So for example, you have one cluster running at [email protected] and the other cluster running at [email protected] this results in regulator constraints being
0.95V-0.95V and 1.05V-1.05V
thus no intersection and whoever comes second looses.
Quoted 5 lines
Quoted 3 lines
and after talking
with real-life users of the soc it seems most desireable to have all 8 cores available at 1.2GHz than only 4 at 1.5GHz max.What's wrong with all at 1.5 GHz?
Only one of the two clusters can do that, see above.
Quoted 5 lines
Quoted 2 lines
But as the clock seems to be bound to the opp table itself simply sharing the table of course also doesn't work
No, the OPP table shouldn't be shared at all. Its something to be shared by a cluster only.
Yeah, with dt (and OPPs) being a hardware description that is true.
Quoted 10 lines
Quoted 6 lines
as only the first clock would be set.
I'm currently only seeing somehow hacky options to solve this, so if you have some direction on how to solve something like this I would be really grateful :-)
I think it should just work, but otherwise as well we can update some framework to make it work. Lets just get on the same line first and help me understand it better.
Heiko
Heiko,
Quoted 12 lines · Heiko Stuebner
Current submitted OPPs can be found at
https://patchwork.kernel.org/patch/9908519/There were still issues with higher frequencies, so they don't list the 1.2 or 1.5GHz yet.
But opp sets pretty tight constraints. I.e. OPPs have of course one preferred voltage, so you end up with
u_volt_min=u_volt_maxfor each operating point, thus the regulator also gets set in this way, removing any intersection and thus making the regulator framework fail to set a voltage for one of the clusters.
Quoted 7 lines
So for example, you have one cluster running at [email protected] and the other cluster running at [email protected] this results in regulator constraints being
0.95V-0.95V and 1.05V-1.05Vthus no intersection and whoever comes second looses.
(Untested) Can't you change the opp table and use the fancier operating point descriptions that give <target min max>?
cluster0_opp: opp-table0 {
compatible = "operating-points-v2";
opp-shared; opp00 {
opp-hz = /bits/ 64 <312000000>;
opp-microvolt = <950000 950000 1050000>;
clock-latency-ns = <40000>;
};
opp01 {
opp-hz = /bits/ 64 <408000000>;
opp-microvolt = <950000 950000 1050000>;
};
opp02 {
opp-hz = /bits/ 64 <600000000>;
opp-microvolt = <950000 950000 1050000>;
};
opp03 {
opp-hz = /bits/ 64 <816000000>;
opp-microvolt = <1025000 1025000 1050000>;
};
opp04 {
opp-hz = /bits/ 64 <1008000000>;
opp-microvolt = <1125000 1125000 1050000>;
};};
cluster1_opp: opp-table1 {
compatible = "operating-points-v2";
opp-shared; opp00 {
opp-hz = /bits/ 64 <312000000>;
opp-microvolt = <950000 950000 1125000>;
clock-latency-ns = <40000>;
};
opp01 {
opp-hz = /bits/ 64 <408000000>;
opp-microvolt = <950000 950000 1125000>;
};
opp02 {
opp-hz = /bits/ 64 <600000000>;
opp-microvolt = <950000 950000 1125000>;
};
opp03 {
opp-hz = /bits/ 64 <816000000>;
opp-microvolt = <975000 975000 1125000>;
};
opp04 {
opp-hz = /bits/ 64 <1008000000>;
opp-microvolt = <1050000>;
};};
In theory the above is a more proper hardware description: AKA you're describing that it's OK to use the higher voltage even at lower operating points.
-Doug
Heiko Stübner
maintainerHi Doug,
Am Montag, 18. September 2017, 16:37:56 CEST schrieb Doug Anderson:
Quoted 20 lines · Heiko Stuebner
Quoted 19 lines
Current submitted OPPs can be found at
https://patchwork.kernel.org/patch/9908519/There were still issues with higher frequencies, so they don't list the 1.2 or 1.5GHz yet.
But opp sets pretty tight constraints. I.e. OPPs have of course one preferred voltage, so you end up with
u_volt_min=u_volt_maxfor each operating point, thus the regulator also gets set in this way, removing any
intersection and thus making the regulator framework fail to set a voltage for one of the clusters.So for example, you have one cluster running at [email protected] and the other cluster running at [email protected] this results in regulator constraints being
0.95V-0.95V
Quoted 8 lines
Quoted 5 lines
and
1.05V-1.05Vthus no intersection and whoever comes second looses.
(Untested) Can't you change the opp table and use the fancier operating point descriptions that give <target min max>?
funny, that I never noticed that opps are also specified for (target, min, max) values.
Thanks for pointing me to the right direction and this seems to actually work. Although I noticed that obviously the max value needs to always be the global maximum (1125000 here) for both opp tables, to make the regulator framework happy.
Quoted 3 lines
In theory the above is a more proper hardware description: AKA you're describing that it's OK to use the higher voltage even at lower operating points.
Thanks
Heiko
Quoted 3 lines · Heiko Stübner
Am Montag, 18. September 2017, 16:37:56 CEST schrieb Doug Anderson:
Quoted 2 lines
(Untested) Can't you change the opp table and use the fancier operating point descriptions that give <target min max>?
And that's exactly what I was going to suggest :)
Quoted 7 lines
funny, that I never noticed that opps are also specified for (target, min, max) values.
Thanks for pointing me to the right direction and this seems to actually work. Although I noticed that obviously the max value needs to always be the global maximum (1125000 here) for both opp tables, to make the regulator framework happy.
Great.
Signature · 1 line
viresh