Patch "hwmon: (k10temp) Only apply temperature offset if result is positive" has been added to the 4.15-stable tree
This is a note to let you know that I've just added the patch titled
hwmon: (k10temp) Only apply temperature offset if result is positive
to the 4.15-stable tree which can be found at:
http://www.kernel.org/git/?p=linux/kernel/git/stable/stable-queue.git;a=summary
The filename of the patch is:
hwmon-k10temp-only-apply-temperature-offset-if-result-is-positive.patch
and it can be found in the queue-4.15 subdirectory.
If you, or anyone else, feels it should not be added to the stable tree, please let <[email protected]> know about it.
Quoted 1 line
From
aef17ca1271948ee57cc39b2493d31110cc42625Mon Sep 17 00:00:00 2001
From: Guenter Roeck <[email protected]>
Date: Wed, 7 Feb 2018 17:49:39 -0800
Subject: hwmon: (k10temp) Only apply temperature offset if result is positive
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: 8bit
From: Guenter Roeck <[email protected]>
commit aef17ca1271948ee57cc39b2493d31110cc42625 upstream.
A user reports a really bad temperature on Ryzen 1950X.
k10temp-pci-00cb
Adapter: PCI adapter
temp1: +4294948.3°C (high = +70.0°C)
This will happen if the temperature reported by the chip is lower than the offset temperature. This has been seen in the field if "Sense MI Skew" and/or "Sense MI Offset" BIOS parameters were set to unexpected values. Let's report a temperature of 0 degrees C in that case.
--- drivers/hwmon/k10temp.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-)
drivers/hwmon/k10temp.c +4 -1
@@ -128,7 +128,10 @@ static ssize_t temp1_input_show(struct d data->read_tempreg (data->pdev, ®val); temp = (regval >>21 ) *125 ; - temp -= data->temp_offset; +if (temp > data->temp_offset) + temp -= data->temp_offset; +else + temp =0 ;return sprintf (buf,"%u\n" , temp); }
Patches currently in stable-queue which might be from [email protected] are
queue-4.15/hwmon-k10temp-add-temperature-offset-for-ryzen-1900x.patch queue-4.15/hwmon-k10temp-only-apply-temperature-offset-if-result-is-positive.patch queue-4.15/acpi-watchdog-fix-off-by-one-error-at-resource-assignment.patch