Skip to contentSkip to conversation

MIPS: BCM47XX: Use standard reset button for Luxul XWR-1750

PATCH Applied Dan Haab 3 participants 3 messages Mar 29, 2018 – Apr 5, 2018

Subsystems (2)
lore
Share & tools
lore

Dan Haab

author
#0 lore raw

PATCH 1/1 MIPS: BCM47XX: Use standard reset button for Luxul XWR-1750

From: Dan Haab <[email protected]>

The original patch submitted for support of the Luxul XWR-1750 used a non-standard button handler for the reset button. This patch will allow using the standard KEY_RESTART

---
 arch/mips/bcm47xx/buttons.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
arch/mips/bcm47xx/buttons.c +1 -1
index 88a8fb2..88d400d 100644
@@ -355,7 +355,7 @@
 
 static const struct gpio_keys_button
 bcm47xx_buttons_luxul_xwr_1750_v1[] = {
-	BCM47XX_GPIO_KEY(14, BTN_TASK),
+	BCM47XX_GPIO_KEY(14, KEY_RESTART),
 };
 
 /* Microsoft */
Signature · 1 line
1.9.1
maintainer
#1 lore raw
Quoted 7 lines · Dan Haab

From: Dan Haab <[email protected]>

The original patch submitted for support of the Luxul XWR-1750 used a non-standard button handler for the reset button. This patch will allow using the standard KEY_RESTART

Looks correct, thanks.

Applied
#2 lore raw
Quoted 11 lines · Rafał Miłecki
Quoted 7 lines · Dan Haab

From: Dan Haab <[email protected]>

The original patch submitted for support of the Luxul XWR-1750 used a non-standard button handler for the reset button. This patch will allow using the standard KEY_RESTART

Looks correct, thanks.

Thanks, applied for 4.17.

Cheers
James