From: Dan Haab <[email protected]>
The original patch submitted for support of the Luxul XWR-1750 used a non-standard button handler for the reset button. This patch will allow using the standard KEY_RESTART
--- arch/mips/bcm47xx/buttons.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
arch/mips/bcm47xx/buttons.c +1 -1
@@ -355,7 +355,7 @@static const struct gpio_keys_button bcm47xx_buttons_luxul_xwr_1750_v1[] = { -BCM47XX_GPIO_KEY (14 ,BTN_TASK ), +BCM47XX_GPIO_KEY (14 ,KEY_RESTART ), };/* Microsoft */
Signature · 1 line
1.9.1
Rafał Miłecki
maintainerQuoted 7 lines · Dan Haab
From: Dan Haab <[email protected]>
The original patch submitted for support of the Luxul XWR-1750 used a non-standard button handler for the reset button. This patch will allow using the standard
KEY_RESTARTSigned-off-by Dan Haab <[email protected]>
Looks correct, thanks.
James Hogan
AppliedQuoted 11 lines · Rafał Miłecki
Quoted 7 lines · Dan Haab
From: Dan Haab <[email protected]>
The original patch submitted for support of the Luxul XWR-1750 used a non-standard button handler for the reset button. This patch will allow using the standard
KEY_RESTARTSigned-off-by Dan Haab <[email protected]>Looks correct, thanks.
Thanks, applied for 4.17.
Cheers