Skip to contentSkip to conversation

FAILED: patch "[PATCH] earlycon: add reg-offset to physical address before mapping" failed to apply to 4.16-stable tree

PATCH [email protected] 1 participant 1 message Apr 16, 2018

Subsystems (2)
lore
Share & tools
lore

[email protected]

author maintainer
#0 lore raw

The patch below does not apply to the 4.16-stable tree.
If someone wants it applied there, or to any other stable or longterm tree, then please email the backport, including the original git commit id to <[email protected]>.

thanks,

greg k-h

------------------ original commit in Linus's tree ------------------

Quoted 1 line

From f572a034d9e07157dd07d2b6be3a1459b5574b58 Mon Sep 17 00:00:00 2001

From: Greentime Hu <[email protected]>
Date: Thu, 16 Nov 2017 19:33:35 +0800
Subject: [PATCH] earlycon: add reg-offset to physical address before mapping

It will get the wrong virtual address because port->mapbase is not added the correct reg-offset yet. We have to update it before earlycon_map() is called

Cc Peter Hurley <[email protected]>
Fixes 088da2a17619 ("of: earlycon: Initialize port fields from DT

properties")

drivers/tty/serial/earlycon.c +2 -1
index 870e84fb6e39..a24278380fec 100644
@@ -245,11 +245,12 @@ int __init of_setup_earlycon(const struct earlycon_id *match,
 	}
 	port->mapbase = addr;
 	port->uartclk = BASE_BAUD * 16;
-	port->membase = earlycon_map(port->mapbase, SZ_4K);
 
 	val = of_get_flat_dt_prop(node, "reg-offset", NULL);
 	if (val)
 		port->mapbase += be32_to_cpu(*val);
+	port->membase = earlycon_map(port->mapbase, SZ_4K);
+
 	val = of_get_flat_dt_prop(node, "reg-shift", NULL);
 	if (val)
 		port->regshift = be32_to_cpu(*val);