Skip to contentSkip to conversation

FAILED: patch "[PATCH] iio: common: st_sensors: fix possible infinite loop in" failed to apply to 4.9-stable tree

PATCH [email protected] 1 participant 1 message Jan 26, 2021

Subsystems (2)
lore
Share & tools
lore

[email protected]

author maintainer
#0 lore raw

The patch below does not apply to the 4.9-stable tree.
If someone wants it applied there, or to any other stable or longterm tree, then please email the backport, including the original git commit id to <[email protected]>.

thanks,

greg k-h

------------------ original commit in Linus's tree ------------------

From 40c48fb79b9798954691f24b8ece1d3a7eb1b353 Mon Sep 17 00:00:00 2001
From: Lorenzo Bianconi <[email protected]>
Date: Tue, 8 Dec 2020 15:36:40 +0100
Subject: [PATCH] iio: common: st_sensors: fix possible infinite loop in
st_sensors_irq_thread

Return a boolean value in st_sensors_new_samples_available routine in order to avoid an infinite loop in st_sensors_irq_thread if stat_drdy.addr is not defined or stat_drdy read fails

drivers/iio/common/st_sensors/st_sensors_trigger.c +17 -14
index 0507283bd4c1..2dbd2646e44e 100644
@@ -23,35 +23,31 @@
  * @sdata: Sensor data.
  *
  * returns:
- * 0 - no new samples available
- * 1 - new samples available
- * negative - error or unknown
+ * false - no new samples available or read error
+ * true - new samples available
  */
-static int st_sensors_new_samples_available(struct iio_dev *indio_dev,
-					    struct st_sensor_data *sdata)
+static bool st_sensors_new_samples_available(struct iio_dev *indio_dev,
+					     struct st_sensor_data *sdata)
 {
 	int ret, status;
 
 	/* How would I know if I can't check it? */
 	if (!sdata->sensor_settings->drdy_irq.stat_drdy.addr)
-		return -EINVAL;
+		return true;
 
 	/* No scan mask, no interrupt */
 	if (!indio_dev->active_scan_mask)
-		return 0;
+		return false;
 
 	ret = regmap_read(sdata->regmap,
 			  sdata->sensor_settings->drdy_irq.stat_drdy.addr,
 			  &status);
 	if (ret < 0) {
 		dev_err(sdata->dev, "error checking samples available\n");
-		return ret;
+		return false;
 	}
 
-	if (status & sdata->sensor_settings->drdy_irq.stat_drdy.mask)
-		return 1;
-
-	return 0;
+	return !!(status & sdata->sensor_settings->drdy_irq.stat_drdy.mask);
 }
 
 /**
@@ -180,9 +176,15 @@ int st_sensors_allocate_trigger(struct iio_dev *indio_dev,
 
 	/* Tell the interrupt handler that we're dealing with edges */
 	if (irq_trig == IRQF_TRIGGER_FALLING ||
-	    irq_trig == IRQF_TRIGGER_RISING)
+	    irq_trig == IRQF_TRIGGER_RISING) {
+		if (!sdata->sensor_settings->drdy_irq.stat_drdy.addr) {
+			dev_err(&indio_dev->dev,
+				"edge IRQ not supported w/o stat register.\n");
+			err = -EOPNOTSUPP;
+			goto iio_trigger_free;
+		}
 		sdata->edge_irq = true;
-	else
+	} else {
 		/*
 		 * If we're not using edges (i.e. level interrupts) we
 		 * just mask off the IRQ, handle one interrupt, then
@@ -190,6 +192,7 @@ int st_sensors_allocate_trigger(struct iio_dev *indio_dev,
 		 * interrupt handler top half again and start over.
 		 */
 		irq_trig |= IRQF_ONESHOT;
+	}
 
 	/*
 	 * If the interrupt pin is Open Drain, by definition this