Skip to contentSkip to conversation

net: phy: at803x: fix probe error if copper page is selected

PATCH Applied Michael Walle 3 participants 3 messages Apr 20, 2021 – Apr 21, 2021

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 net: phy: at803x: fix probe error if copper page is selected

The commit c329e5afb42f ("net: phy: at803x: select correct page on config init") selects the copper page during probe. This fails if the copper page was already selected. In this case, the value of the copper page (which is 1) is propagated through phy_restore_page() and is finally returned for at803x_probe(). Fix it, by just using the at803x_page_write() directly.

Also in case of an error, the regulator is not disabled and leads to a WARN_ON() when the probe fails. This couldn't happen before, because at803x_parse_dt() was the last call in at803x_probe(). It is hard to see, that the parse_dt() actually enables the regulator. Thus move the regulator_enable() to the probe function and undo it in case of an error.

Fixes c329e5afb42f ("net: phy: at803x: select correct page on config init")

---
Changes since v1:
- take the bus lock

 drivers/net/phy/at803x.c | 23 +++++++++++++++++------
 1 file changed, 17 insertions(+), 6 deletions(-)
drivers/net/phy/at803x.c +17 -6
index e0f56850edc5..32af52dd5aed 100644
@@ -554,10 +554,6 @@ static int at803x_parse_dt(struct phy_device *phydev)
 			phydev_err(phydev, "failed to get VDDIO regulator\n");
 			return PTR_ERR(priv->vddio);
 		}
-
-		ret = regulator_enable(priv->vddio);
-		if (ret < 0)
-			return ret;
 	}
 
 	return 0;
@@ -579,15 +575,30 @@ static int at803x_probe(struct phy_device *phydev)
 	if (ret)
 		return ret;
 
+	if (priv->vddio) {
+		ret = regulator_enable(priv->vddio);
+		if (ret < 0)
+			return ret;
+	}
+
 	/* Some bootloaders leave the fiber page selected.
 	 * Switch to the copper page, as otherwise we read
 	 * the PHY capabilities from the fiber side.
 	 */
 	if (at803x_match_phy_id(phydev, ATH8031_PHY_ID)) {
-		ret = phy_select_page(phydev, AT803X_PAGE_COPPER);
-		ret = phy_restore_page(phydev, AT803X_PAGE_COPPER, ret);
+		phy_lock_mdio_bus(phydev);
+		ret = at803x_write_page(phydev, AT803X_PAGE_COPPER);
+		phy_unlock_mdio_bus(phydev);
+		if (ret)
+			goto err;
 	}
 
+	return 0;
+
+err:
+	if (priv->vddio)
+		regulator_disable(priv->vddio);
+
 	return ret;
 }
 
Signature · 1 line
2.20.1
Reviewed-by on v2 1/1
#1 lore raw

Hi,

Quoted 6 lines · Michael Walle

The commit c329e5afb42f ("net: phy: at803x: select correct page on config init") selects the copper page during probe. This fails if the copper page was already selected. In this case, the value of the copper page (which is 1) is propagated through phy_restore_page() and is finally returned for at803x_probe(). Fix it, by just using the at803x_page_write() directly.

Ouch, i didn't spot that. Thanks for taking care.

Quoted 10 lines

Also in case of an error, the regulator is not disabled and leads to a WARN_ON() when the probe fails. This couldn't happen before, because at803x_parse_dt() was the last call in at803x_probe(). It is hard to see, that the parse_dt() actually enables the regulator. Thus move the regulator_enable() to the probe function and undo it in case of an error.

Fixes c329e5afb42f ("net: phy: at803x: select correct page on config init")

Best
David

Quoted 56 lines

---
Changes since v1:
- take the bus lock

 drivers/net/phy/at803x.c | 23 +++++++++++++++++------
 1 file changed, 17 insertions(+), 6 deletions(-)
drivers/net/phy/at803x.c +17 -6
index e0f56850edc5..32af52dd5aed 100644
@@ -554,10 +554,6 @@ static int at803x_parse_dt(struct phy_device *phydev)
 			phydev_err(phydev, "failed to get VDDIO regulator\n");
 			return PTR_ERR(priv->vddio);
 		}
-
-		ret = regulator_enable(priv->vddio);
-		if (ret < 0)
-			return ret;
 	}
 
 	return 0;
@@ -579,15 +575,30 @@ static int at803x_probe(struct phy_device *phydev)
 	if (ret)
 		return ret;
 
+	if (priv->vddio) {
+		ret = regulator_enable(priv->vddio);
+		if (ret < 0)
+			return ret;
+	}
+
 	/* Some bootloaders leave the fiber page selected.
 	 * Switch to the copper page, as otherwise we read
 	 * the PHY capabilities from the fiber side.
 	 */
 	if (at803x_match_phy_id(phydev, ATH8031_PHY_ID)) {
-		ret = phy_select_page(phydev, AT803X_PAGE_COPPER);
-		ret = phy_restore_page(phydev, AT803X_PAGE_COPPER, ret);
+		phy_lock_mdio_bus(phydev);
+		ret = at803x_write_page(phydev, AT803X_PAGE_COPPER);
+		phy_unlock_mdio_bus(phydev);
+		if (ret)
+			goto err;
 	}
 
+	return 0;
+
+err:
+	if (priv->vddio)
+		regulator_disable(priv->vddio);
+
 	return ret;
 }
 
#2 lore raw
In reply to Michael Walle
This patch was applied to netdev/net-next.git (refs/heads/master):

Hello:

This patch was applied to netdev/net-next.git (refs/heads/master):

Quoted 8 lines · On Tue, 20 Apr 2021 12:29:29 +0200 you wrote:

The commit c329e5afb42f ("net: phy: at803x: select correct page on config init") selects the copper page during probe. This fails if the copper page was already selected. In this case, the value of the copper page (which is 1) is propagated through phy_restore_page() and is finally returned for at803x_probe(). Fix it, by just using the at803x_page_write() directly.

[...]

Here is the summary with links:
- [net-next,v2] net: phy: at803x: fix probe error if copper page is selected

    https://git.kernel.org/netdev/net-next/c/8f7e876273e2

You are awesome, thank you!
--
Deet-doot-dot, I am a bot.
https://korg.docs.kernel.org/patchwork/pwbot.html