arm: dts: imx7d-sdb: config the max pressure for tsc2046

PATCH Applied [email protected] 2 participants 2 messages Jul 25, 2022 – Aug 21, 2022

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 arm: dts: imx7d-sdb: config the max pressure for tsc2046

From: Haibo Chen <[email protected]>

Use the general touchscreen method to config the max pressure for touch tsc2046(data sheet suggest 8 bit pressure), otherwise, for ABS_PRESSURE, when config the same max and min value, weston will meet the following issue,

[17:19:39.183] event1  - ADS7846 Touchscreen: is tagged by udev as: Touchscreen
[17:19:39.183] event1  - ADS7846 Touchscreen: kernel bug: device has min == max on ABS_PRESSURE
[17:19:39.183] event1  - ADS7846 Touchscreen: was rejected
[17:19:39.183] event1  - not using input device '/dev/input/event1'

This will then cause the APP weston-touch-calibrator can't list touch devices.

root@imx6ul7d:~# weston-touch-calibrator
could not load cursor 'dnd-move'
could not load cursor 'dnd-copy'
could not load cursor 'dnd-none'
No devices listed.

And accroding to binding Doc, "ti,x-max", "ti,y-max", "ti,pressure-max" belong to the deprecated properties, so remove them. Also for "ti,x-min", "ti,y-min", "ti,x-plate-ohms", the value set in dts equal to the default value in driver, so are redundant, also remove here.

---
 arch/arm/boot/dts/imx7d-sdb.dts | 7 +------
 1 file changed, 1 insertion(+), 6 deletions(-)
arch/arm/boot/dts/imx7d-sdb.dts +1 -6
index 78f4224a9bf4..e93b9cd9c27b 100644
@@ -206,12 +206,7 @@ tsc2046@0 {
 		interrupt-parent = <&gpio2>;
 		interrupts = <29 0>;
 		pendown-gpio = <&gpio2 29 GPIO_ACTIVE_HIGH>;
-		ti,x-min = /bits/ 16 <0>;
-		ti,x-max = /bits/ 16 <0>;
-		ti,y-min = /bits/ 16 <0>;
-		ti,y-max = /bits/ 16 <0>;
-		ti,pressure-max = /bits/ 16 <0>;
-		ti,x-plate-ohms = /bits/ 16 <400>;
+		touchscreen-max-pressure = <255>;
 		wakeup-source;
 	};
 };
Signature · 1 line
2.25.1
Applied
#1 lore raw
Quoted 20 lines · On Mon, Jul 25, 2022 at 06:16:22PM +0800, [email protected] wrote:

From: Haibo Chen <[email protected]>

Use the general touchscreen method to config the max pressure for touch tsc2046(data sheet suggest 8 bit pressure), otherwise, for ABS_PRESSURE, when config the same max and min value, weston will meet the following issue,

[17:19:39.183] event1  - ADS7846 Touchscreen: is tagged by udev as: Touchscreen
[17:19:39.183] event1  - ADS7846 Touchscreen: kernel bug: device has min == max on ABS_PRESSURE
[17:19:39.183] event1  - ADS7846 Touchscreen: was rejected
[17:19:39.183] event1  - not using input device '/dev/input/event1'

This will then cause the APP weston-touch-calibrator can't list touch devices.

root@imx6ul7d:~# weston-touch-calibrator
could not load cursor 'dnd-move'
could not load cursor 'dnd-copy'
could not load cursor 'dnd-none'
No devices listed.
Quoted 6 lines

And accroding to binding Doc, "ti,x-max", "ti,y-max", "ti,pressure-max" belong to the deprecated properties, so remove them. Also for "ti,x-min", "ti,y-min", "ti,x-plate-ohms", the value set in dts equal to the default value in driver, so are redundant, also remove here.

Applied, thanks!