octeontx2-pf: mcs: Support VLAN in clear text
Subbaraya Sundeep
maintainerPATCH v2 1/1 octeontx2-pf: mcs: Support VLAN in clear text
Detect whether macsec secy is running on top of VLAN which implies transmitting VLAN tag in clear text before macsec SecTag. In this case configure hardware to insert SecTag after VLAN tag.
Signed-off-by Subbaraya Sundeep <[email protected]>
Signed-off-by Sunil Kovvuri Goutham <[email protected]>
---
v2:
Arranged variable tag_offset in reverse christmas tree order
drivers/net/ethernet/marvell/octeontx2/nic/cn10k_macsec.c | 8 ++++++-- drivers/net/ethernet/marvell/octeontx2/nic/otx2_common.h | 1 + 2 files changed, 7 insertions(+), 2 deletions(-)
drivers/net/ethernet/marvell/octeontx2/nic/cn10k_macsec.c +6 -2
@@ -426,13 +426,16 @@ static int cn10k_mcs_write_tx_secy(struct otx2_nic *pfvf,struct mcs_secy_plcy_write_req *req;struct mbox *mbox = &pfvf->mbox;struct macsec_tx_sc *sw_tx_sc; -/* Insert SecTag after 12 bytes (DA+SA)*/ -u8 tag_offset =12 ;u8 sectag_tci =0 ; +u8 tag_offset;u64 policy;u8 cipher;int ret; +/* Insert SecTag after 12 bytes (DA+SA) or 16 bytes +* if VLAN tag needs to be sent in clear text. +*/ + tag_offset = txsc->vlan_dev ?16 :12 ; sw_tx_sc = &secy->tx_sc;mutex_lock (&mbox->lock);
@@ -1163,6 +1166,7 @@ static int cn10k_mdo_add_secy(struct macsec_context *ctx) txsc->encoding_sa = secy->tx_sc.encoding_sa; txsc->last_validate_frames = secy->validate_frames; txsc->last_replay_protect = secy->replay_protect; + txsc->vlan_dev =is_vlan_dev (ctx->netdev);list_add (&txsc->entry, &cfg->txsc_list);
drivers/net/ethernet/marvell/octeontx2/nic/otx2_common.h +1 -0
@@ -419,6 +419,7 @@ struct cn10k_mcs_txsc {u8 encoding_sa;u8 salt[CN10K_MCS_SA_PER_SC ][MACSEC_SALT_LEN ];ssci_t ssci[CN10K_MCS_SA_PER_SC ]; +bool vlan_dev;/* macsec running on VLAN ? */ };struct cn10k_mcs_rxsc {
Signature · 1 line
2.7.4
This patch was applied to netdev/net-next.git (main) by David S. Miller <[email protected]>:
Hello:
This patch was applied to netdev/net-next.git (main) by David S. Miller <[email protected]>:
Quoted 9 lines · On Tue, 16 May 2023 17:10:31 +0530 you wrote:
Detect whether macsec secy is running on top of VLAN which implies transmitting VLAN tag in clear text before macsec SecTag. In this case configure hardware to insert SecTag after VLAN tag.
Signed-off-by Subbaraya Sundeep <[email protected]>Signed-off-by Sunil Kovvuri Goutham <[email protected]>[...]
Here is the summary with links:
- [net-next,v2] octeontx2-pf: mcs: Support VLAN in clear text
https://git.kernel.org/netdev/net-next/c/030d71fd93b1
You are awesome, thank you!
Signature · 2 lines
Deet-doot-dot, I am a bot. https://korg.docs.kernel.org/patchwork/pwbot.html