platform/x86: thinkpad_acpi: fix for incorrect fan reporting on some ThinkPad systems
PATCH v2 1/1 platform/x86: thinkpad_acpi: fix for incorrect fan reporting on some ThinkPad systems
Some ThinkPad systems ECFW use non-standard addresses for fan control and reporting. This patch adds support for such ECFW so that it can report the correct fan values.
Tested on Thinkpads L13 Yoga Gen 2 and X13 Yoga Gen 2.
---
-Improvements to comments as requested.
-Removed the usage of unlikely/likely while reading fan speed. -Improved and clearer print statements to match the current style. -Changed seq_puts to seq_printf of an unrelated section of the patch. -Improved the readability of the code.
-Added more clearer comments.
--- drivers/platform/x86/thinkpad_acpi.c | 98 ++++++++++++++++++++++++---- 1 file changed, 85 insertions(+), 13 deletions(-)
drivers/platform/x86/thinkpad_acpi.c +85 -13
@@ -7948,8 +7948,19 @@ static struct ibm_struct volume_driver_data = {* TPACPI_FAN_WR_TPEC is also available and should be used to * command the fan. The X31/X40/X41 seems to have 8 fan levels, * but the ACPI tables just mention level 7. +* +* TPACPI_FAN_RD_TPEC_NS: +* This mode is used for a few ThinkPads (L13 Yoga Gen2, X13 Yoga Gen2 etc.) +* that are using non-standard EC locations for reporting fan speeds. +* Currently these platforms only provide fan rpm reporting. +* */ +#define FAN_RPM_CAL_CONST 491520/* FAN RPM calculation offset for some non-standard ECFW */ + +#define FAN_NS_CTRL_STATUS BIT(2)/* Bit which determines control is enabled or not */ +#define FAN_NS_CTRL BIT(4)/* Bit which determines control is by host or EC */ +enum {/* Fan control constants */ fan_status_offset =0x2f ,/* EC register 0x2f */ fan_rpm_offset =0x84 ,/* EC register 0x84: LSB, 0x85 MSB (RPM)
@@ -7957,6 +7968,11 @@ enum { /* Fan control constants */ fan_select_offset =0x31 ,/* EC register 0x31 (Firmware 7M) bit 0 selects which fan is active */ + fan_status_offset_ns =0x93 ,/* Special status/control offset for non-standard EC Fan1 */ + fan2_status_offset_ns =0x96 ,/* Special status/control offset for non-standard EC Fan2 */ + fan_rpm_status_ns =0x95 ,/* Special offset for Fan1 RPM status for non-standard EC */ + fan2_rpm_status_ns =0x98 ,/* Special offset for Fan2 RPM status for non-standard EC */ +TP_EC_FAN_FULLSPEED =0x40 ,/* EC fan mode: full speed */ TP_EC_FAN_AUTO = 0x80, /* EC fan mode: auto fan control */
@@ -7967,6 +7983,7 @@ enum fan_status_access_mode {TPACPI_FAN_NONE =0 ,/* No fan status or control */ TPACPI_FAN_RD_ACPI_GFAN ,/* Use ACPI GFAN */ TPACPI_FAN_RD_TPEC ,/* Use ACPI EC regs 0x2f, 0x84-0x85 */ + TPACPI_FAN_RD_TPEC_NS, /* Use non-standard ACPI EC regs (eg: L13 Yoga gen2 etc.) */ }; enum fan_control_access_mode {
@@ -7994,6 +8011,8 @@ static u8 fan_control_desired_level;static u8 fan_control_resume_level;static int fan_watchdog_maxinterval; +static bool fan_with_ns_addr; +static struct mutex fan_mutex;static void fan_watchdog_fire (struct work_struct *ignored);
@@ -8123,6 +8142,15 @@ static int fan_get_status(u8 *status) }break ; +case TPACPI_FAN_RD_TPEC_NS : +/* Default mode is AUTO which means controlled by EC */ +if (!acpi_ec_read (fan_status_offset_ns, &s)) +return -EIO ; + +if (status) + *status = s; + +break ;default :return -ENXIO ;
@@ -8139,7 +8167,8 @@ static int fan_get_status_safe(u8 *status)if (mutex_lock_killable (&fan_mutex))return -ERESTARTSYS ; rc =fan_get_status (&s); -if (!rc) +/* NS EC doesn't have register with level settings */ +if (!rc && !fan_with_ns_addr)fan_update_desired_level (s);mutex_unlock (&fan_mutex);
@@ -8166,7 +8195,13 @@ static int fan_get_speed(unsigned int *speed)if (likely (speed)) *speed = (hi <<8 ) | lo; +break ; +case TPACPI_FAN_RD_TPEC_NS : +if (!acpi_ec_read (fan_rpm_status_ns, &lo)) +return -EIO ; +if (speed) + *speed = lo ?FAN_RPM_CAL_CONST / lo :0 ;break ;default :
@@ -8178,7 +8213,7 @@ static int fan_get_speed(unsigned int *speed)static int fan2_get_speed (unsigned int *speed) { -u8 hi, lo; +u8 hi, lo, status;bool rc;switch (fan_status_access_mode) {
@@ -8194,7 +8229,21 @@ static int fan2_get_speed(unsigned int *speed)if (likely (speed)) *speed = (hi <<8 ) | lo; +break ; +case TPACPI_FAN_RD_TPEC_NS : + rc = !acpi_ec_read (fan2_status_offset_ns, &status); +if (rc) +return -EIO ; +if (!(status &FAN_NS_CTRL_STATUS )) { +pr_info ("secondary fan control not supported\n" ); +return -EIO ; + } + rc = !acpi_ec_read (fan2_rpm_status_ns, &lo); +if (rc) +return -EIO ; +if (speed) + *speed = lo ?FAN_RPM_CAL_CONST / lo :0 ;break ;default :
@@ -8697,6 +8746,7 @@ static const struct attribute_group fan_driver_attr_group = {#define TPACPI_FAN_2FAN 0x0002/* EC 0x31 bit 0 selects fan2 */ #define TPACPI_FAN_2CTL 0x0004/* selects fan2 control */ #define TPACPI_FAN_NOFAN 0x0008/* no fan available */ +#define TPACPI_FAN_NS 0x0010/* For EC with non-Standard register addresses */ static const struct tpacpi_quirk fan_quirk_table[]__initconst = {TPACPI_QEC_IBM ('1' ,'Y' ,TPACPI_FAN_Q1 ),
@@ -8715,6 +8765,8 @@ static const struct tpacpi_quirk fan_quirk_table[] __initconst = {TPACPI_Q_LNV3 ('N' ,'2' ,'O' ,TPACPI_FAN_2CTL ),/* P1 / X1 Extreme (2nd gen) */ TPACPI_Q_LNV3 ('N' ,'3' ,'0' ,TPACPI_FAN_2CTL ),/* P15 (1st gen) / P15v (1st gen) */ TPACPI_Q_LNV3 ('N' ,'3' ,'7' ,TPACPI_FAN_2CTL ),/* T15g (2nd gen) */ +TPACPI_Q_LNV3 ('R' ,'1' ,'F' ,TPACPI_FAN_NS ),/* L13 Yoga Gen 2 */ +TPACPI_Q_LNV3 ('N' ,'2' ,'U' ,TPACPI_FAN_NS ),/* X13 Yoga Gen 2*/ TPACPI_Q_LNV3('N', '1', 'O', TPACPI_FAN_NOFAN), /* X1 Tablet (2nd gen) */ };
@@ -8749,18 +8801,27 @@ static int __init fan_init(struct ibm_init_struct *iibm)return -ENODEV ; } +if (quirks &TPACPI_FAN_NS ) { +pr_info ("ECFW with non-standard fan reg control found\n" ); + fan_with_ns_addr =1 ; +/* Fan ctrl support from host is undefined for now */ + tp_features.fan_ctrl_status_undef =1 ; + } +if (gfan_handle) {/* 570, 600e/x, 770e, 770x */ fan_status_access_mode =TPACPI_FAN_RD_ACPI_GFAN ; }else {/* all other ThinkPads: note that even old-style * ThinkPad ECs supports the fan control register */ -if (likely (acpi_ec_read (fan_status_offset, - &fan_control_initial_status))) { +if (fan_with_ns_addr || +likely (acpi_ec_read (fan_status_offset, &fan_control_initial_status))) {int res;unsigned int speed; - fan_status_access_mode =TPACPI_FAN_RD_TPEC ; + fan_status_access_mode = fan_with_ns_addr ? +TPACPI_FAN_RD_TPEC_NS :TPACPI_FAN_RD_TPEC ; +if (quirks &TPACPI_FAN_Q1 )fan_quirk1_setup ();/* Try and probe the 2nd fan */
@@ -8769,7 +8830,8 @@ static int __init fan_init(struct ibm_init_struct *iibm)if (res >=0 && speed !=FAN_NOT_PRESENT ) {/* It responded - so let's assume it's there */ tp_features.second_fan =1 ; - tp_features.second_fan_ctl =1 ; +/* fan control not currently available for ns ECFW */ + tp_features.second_fan_ctl = !fan_with_ns_addr;pr_info ("secondary fan control detected & enabled\n" ); }else {/* Fan not auto-detected */
@@ -8944,6 +9006,7 @@ static int fan_read(struct seq_file *m) str_enabled_disabled(status), status);break ; +case TPACPI_FAN_RD_TPEC_NS :case TPACPI_FAN_RD_TPEC :/* all except 570, 600e/x, 770e, 770x */ rc =fan_get_status_safe (&status);
@@ -8958,13 +9021,22 @@ static int fan_read(struct seq_file *m)seq_printf (m,"speed:\t\t%d\n" , speed); -if (status &TP_EC_FAN_FULLSPEED ) -/* Disengaged mode takes precedence */ -seq_printf (m,"level:\t\tdisengaged\n" ); -else if (status &TP_EC_FAN_AUTO ) -seq_printf (m,"level:\t\tauto\n" ); -else -seq_printf (m,"level:\t\t%d\n" , status); +if (fan_status_access_mode ==TPACPI_FAN_RD_TPEC_NS ) { +/* +* No full speed bit in NS EC +* EC Auto mode is set by default. +* No other levels settings available +*/ +seq_printf (m,"level:\t\t%s\n" , status &FAN_NS_CTRL ?"unknown" :"auto" ); + }else { +if (status &TP_EC_FAN_FULLSPEED ) +/* Disengaged mode takes precedence */ +seq_printf (m,"level:\t\tdisengaged\n" ); +else if (status &TP_EC_FAN_AUTO ) +seq_printf (m,"level:\t\tauto\n" ); +else +seq_printf (m,"level:\t\t%d\n" , status); + }break ;case TPACPI_FAN_NONE :
Signature · 1 line
2.34.1
Quoted 8 lines · Vishnu Sankar
Some ThinkPad systems ECFW use non-standard addresses for fan control and reporting. This patch adds support for such ECFW so that it can report the correct fan values.
Tested on Thinkpads L13 Yoga Gen 2 and X13 Yoga Gen 2.Suggested-by Mark Pearson <[email protected]>Signed-off-by Vishnu Sankar <[email protected]>---
Review
Quoted 6 lines
(quoted diff) +0
-6-Improvements to comments as requested. -Removed the usage of unlikely/likely while reading fan speed. -Improved and clearer print statements to match the current style. -Changed seq_puts to seq_printf of an unrelated section of the patch. -Improved the readability of the code. -Added more clearer comments.
Nice work, thanks.
Signature · 1 line
i.
Hi Ilpo,
Thank you for the review.
Vishnu
Quoted 25 lines · Ilpo Järvinen
Quoted 8 lines · Vishnu Sankar
Some ThinkPad systems ECFW use non-standard addresses for fan control and reporting. This patch adds support for such ECFW so that it can report the correct fan values.
Tested on Thinkpads L13 Yoga Gen 2 and X13 Yoga Gen 2.Suggested-by Mark Pearson <[email protected]>Signed-off-by Vishnu Sankar <[email protected]>---
Review
Quoted 6 lines
(quoted diff) +0
-6-Improvements to comments as requested. -Removed the usage of unlikely/likely while reading fan speed. -Improved and clearer print statements to match the current style. -Changed seq_puts to seq_printf of an unrelated section of the patch. -Improved the readability of the code. -Added more clearer comments.Nice work, thanks.
Reviewed-by Ilpo Järvinen <[email protected]>--
i.
Signature · 4 lines
Regards,
Vishnu Sankar
+817015150407 (Japan)Hans de Goede
Reviewed-byHi,
Quoted 19 lines · Ilpo Järvinen
Quoted 8 lines · Vishnu Sankar
Some ThinkPad systems ECFW use non-standard addresses for fan control and reporting. This patch adds support for such ECFW so that it can report the correct fan values.
Tested on Thinkpads L13 Yoga Gen 2 and X13 Yoga Gen 2.Suggested-by Mark Pearson <[email protected]>Signed-off-by Vishnu Sankar <[email protected]>---
Review
Quoted 6 lines
(quoted diff) +0
-6-Improvements to comments as requested. -Removed the usage of unlikely/likely while reading fan speed. -Improved and clearer print statements to match the current style. -Changed seq_puts to seq_printf of an unrelated section of the patch. -Improved the readability of the code. -Added more clearer comments.Nice work, thanks.
Quoted 1 line
Reviewed-by Ilpo Järvinen <[email protected]>
Ilpo, thank you for the review.
The patch looks good to me too:
Ilpo, do you plan on sending out one more fixes pull-req for 6.7 and if yes, can you add this patch to that; or shall I merge this into for-next so that it gets included in 6.8-rc1 ?
Regards,
Hans
Ilpo Järvinen
maintainerQuoted 6 lines · Vishnu Sankar
Some ThinkPad systems ECFW use non-standard addresses for fan control and reporting. This patch adds support for such ECFW so that it can report the correct fan values.
Tested on Thinkpads L13 Yoga Gen 2 and X13 Yoga Gen 2.
Thank you for your contribution, it has been applied to my local review-ilpo branch. Note it will show up in the public platform-drivers-x86/review-ilpo branch only once I've pushed my local branch there, which might take a while.
The list of commits applied:
[1/1] platform/x86: thinkpad_acpi: fix for incorrect fan reporting on some ThinkPad systems
commit: 66e92e23a72761f5b53f970aeb1badc5fd92fc74
--
i.