PATCH 1/1 net/smc: fix invalid link access in dumping SMC-R connections

A crash was found when dumping SMC-R connections. It can be reproduced by following steps:

- environment: two RNICs on both sides.
- run SMC-R between two sides, now a SMC_LGR_SYMMETRIC type link group will be created.
- set the first RNIC down on either side and link group will turn to SMC_LGR_ASYMMETRIC_LOCAL then.
- run 'smcss -R' and the crash will be triggered.

 BUG: kernel NULL pointer dereference, address: 0000000000000010
 #PF: supervisor read access in kernel mode
 #PF: error_code(0x0000) - not-present page
 PGD 8000000101fdd067 P4D 8000000101fdd067 PUD 10ce46067 PMD 0
 Oops: 0000 [#1] PREEMPT SMP PTI
 CPU: 3 PID: 1810 Comm: smcss Kdump: loaded Tainted: G W   E      6.7.0-rc6+ #51
 RIP: 0010:__smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
 Call Trace:
  <TASK>
  ? __die+0x24/0x70
  ? page_fault_oops+0x66/0x150
  ? exc_page_fault+0x69/0x140
  ? asm_exc_page_fault+0x26/0x30
  ? __smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
  smc_diag_dump_proto+0xd0/0xf0 [smc_diag]
  smc_diag_dump+0x26/0x60 [smc_diag]
  netlink_dump+0x19f/0x320
  __netlink_dump_start+0x1dc/0x300
  smc_diag_handler_dump+0x6a/0x80 [smc_diag]
  ? __pfx_smc_diag_dump+0x10/0x10 [smc_diag]
  sock_diag_rcv_msg+0x121/0x140
  ? __pfx_sock_diag_rcv_msg+0x10/0x10
  netlink_rcv_skb+0x5a/0x110
  sock_diag_rcv+0x28/0x40
  netlink_unicast+0x22a/0x330
  netlink_sendmsg+0x240/0x4a0
  __sock_sendmsg+0xb0/0xc0
  ____sys_sendmsg+0x24e/0x300
  ? copy_msghdr_from_user+0x62/0x80
  ___sys_sendmsg+0x7c/0xd0
  ? __do_fault+0x34/0x1a0
  ? do_read_fault+0x5f/0x100
  ? do_fault+0xb0/0x110
  __sys_sendmsg+0x4d/0x80
  do_syscall_64+0x45/0xf0
  entry_SYSCALL_64_after_hwframe+0x6e/0x76

When the first RNIC is set down, the lgr->lnk[0] will be cleared and an asymmetric link will be allocated in lgr->link[SMC_LINKS_PER_LGR_MAX - 1] by smc_llc_alloc_alt_link(). Then when we try to dump SMC-R connections in __smc_diag_dump(), the invalid lgr->lnk[0] will be accessed, resulting in this issue. So fix it by accessing the right link.

Fixes f16a7dd5cf27 ("smc: netlink interface for SMC sockets")
---
 net/smc/smc_diag.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)
net/smc/smc_diag.c +1 -2
index a584613aca12..5cc376834c57 100644
@@ -153,8 +153,7 @@ static int __smc_diag_dump(struct sock *sk, struct sk_buff *skb,
 			.lnk[0].link_id = link->link_id,
 		};
 
-		memcpy(linfo.lnk[0].ibname,
-		       smc->conn.lgr->lnk[0].smcibdev->ibdev->name,
+		memcpy(linfo.lnk[0].ibname, link->smcibdev->ibdev->name,
 		       sizeof(link->smcibdev->ibdev->name));
 		smc_gid_be16_convert(linfo.lnk[0].gid, link->gid);
 		smc_gid_be16_convert(linfo.lnk[0].peer_gid, link->peer_gid);
Signature · 1 line
2.43.0
reviewer Reviewed-by on v1 1/1
#1 lore raw
Quoted 53 lines · Wen Gu

A crash was found when dumping SMC-R connections. It can be reproduced by following steps:

- environment: two RNICs on both sides.
- run SMC-R between two sides, now a SMC_LGR_SYMMETRIC type link group will be created.
- set the first RNIC down on either side and link group will turn to SMC_LGR_ASYMMETRIC_LOCAL then.
- run 'smcss -R' and the crash will be triggered.

 BUG: kernel NULL pointer dereference, address: 0000000000000010
 #PF: supervisor read access in kernel mode
 #PF: error_code(0x0000) - not-present page
 PGD 8000000101fdd067 P4D 8000000101fdd067 PUD 10ce46067 PMD 0
 Oops: 0000 [#1] PREEMPT SMP PTI
 CPU: 3 PID: 1810 Comm: smcss Kdump: loaded Tainted: G W   E      6.7.0-rc6+ #51
 RIP: 0010:__smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
 Call Trace:
  <TASK>
  ? __die+0x24/0x70
  ? page_fault_oops+0x66/0x150
  ? exc_page_fault+0x69/0x140
  ? asm_exc_page_fault+0x26/0x30
  ? __smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
  smc_diag_dump_proto+0xd0/0xf0 [smc_diag]
  smc_diag_dump+0x26/0x60 [smc_diag]
  netlink_dump+0x19f/0x320
  __netlink_dump_start+0x1dc/0x300
  smc_diag_handler_dump+0x6a/0x80 [smc_diag]
  ? __pfx_smc_diag_dump+0x10/0x10 [smc_diag]
  sock_diag_rcv_msg+0x121/0x140
  ? __pfx_sock_diag_rcv_msg+0x10/0x10
  netlink_rcv_skb+0x5a/0x110
  sock_diag_rcv+0x28/0x40
  netlink_unicast+0x22a/0x330
  netlink_sendmsg+0x240/0x4a0
  __sock_sendmsg+0xb0/0xc0
  ____sys_sendmsg+0x24e/0x300
  ? copy_msghdr_from_user+0x62/0x80
  ___sys_sendmsg+0x7c/0xd0
  ? __do_fault+0x34/0x1a0
  ? do_read_fault+0x5f/0x100
  ? do_fault+0xb0/0x110
  __sys_sendmsg+0x4d/0x80
  do_syscall_64+0x45/0xf0
  entry_SYSCALL_64_after_hwframe+0x6e/0x76

When the first RNIC is set down, the lgr->lnk[0] will be cleared and an asymmetric link will be allocated in lgr->link[SMC_LINKS_PER_LGR_MAX - 1] by smc_llc_alloc_alt_link(). Then when we try to dump SMC-R connections in __smc_diag_dump(), the invalid lgr->lnk[0] will be accessed, resulting in this issue. So fix it by accessing the right link.

Quoted 3 lines
Fixes f16a7dd5cf27 ("smc: netlink interface for SMC sockets")

What about using Link: http... here?

Quoted 1 line
Quoted 20 lines
---
 net/smc/smc_diag.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)
net/smc/smc_diag.c +1 -2
index a584613aca12..5cc376834c57 100644
@@ -153,8 +153,7 @@ static int __smc_diag_dump(struct sock *sk, struct sk_buff *skb,
 			.lnk[0].link_id = link->link_id,
 		};
 
-		memcpy(linfo.lnk[0].ibname,
-		       smc->conn.lgr->lnk[0].smcibdev->ibdev->name,
+		memcpy(linfo.lnk[0].ibname, link->smcibdev->ibdev->name,
 		       sizeof(link->smcibdev->ibdev->name));
 		smc_gid_be16_convert(linfo.lnk[0].gid, link->gid);
 		smc_gid_be16_convert(linfo.lnk[0].peer_gid, link->peer_gid);
Signature · 1 line
2.43.0
author reviewer
#2 lore raw
Quoted 54 lines · Tony Lu
Quoted 53 lines · Wen Gu

A crash was found when dumping SMC-R connections. It can be reproduced by following steps:

- environment: two RNICs on both sides.
- run SMC-R between two sides, now a SMC_LGR_SYMMETRIC type link group will be created.
- set the first RNIC down on either side and link group will turn to SMC_LGR_ASYMMETRIC_LOCAL then.
- run 'smcss -R' and the crash will be triggered.

  BUG: kernel NULL pointer dereference, address: 0000000000000010
  #PF: supervisor read access in kernel mode
  #PF: error_code(0x0000) - not-present page
  PGD 8000000101fdd067 P4D 8000000101fdd067 PUD 10ce46067 PMD 0
  Oops: 0000 [#1] PREEMPT SMP PTI
  CPU: 3 PID: 1810 Comm: smcss Kdump: loaded Tainted: G W   E      6.7.0-rc6+ #51
  RIP: 0010:__smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
  Call Trace:
   <TASK>
   ? __die+0x24/0x70
   ? page_fault_oops+0x66/0x150
   ? exc_page_fault+0x69/0x140
   ? asm_exc_page_fault+0x26/0x30
   ? __smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
   smc_diag_dump_proto+0xd0/0xf0 [smc_diag]
   smc_diag_dump+0x26/0x60 [smc_diag]
   netlink_dump+0x19f/0x320
   __netlink_dump_start+0x1dc/0x300
   smc_diag_handler_dump+0x6a/0x80 [smc_diag]
   ? __pfx_smc_diag_dump+0x10/0x10 [smc_diag]
   sock_diag_rcv_msg+0x121/0x140
   ? __pfx_sock_diag_rcv_msg+0x10/0x10
   netlink_rcv_skb+0x5a/0x110
   sock_diag_rcv+0x28/0x40
   netlink_unicast+0x22a/0x330
   netlink_sendmsg+0x240/0x4a0
   __sock_sendmsg+0xb0/0xc0
   ____sys_sendmsg+0x24e/0x300
   ? copy_msghdr_from_user+0x62/0x80
   ___sys_sendmsg+0x7c/0xd0
   ? __do_fault+0x34/0x1a0
   ? do_read_fault+0x5f/0x100
   ? do_fault+0xb0/0x110
   __sys_sendmsg+0x4d/0x80
   do_syscall_64+0x45/0xf0
   entry_SYSCALL_64_after_hwframe+0x6e/0x76

When the first RNIC is set down, the lgr->lnk[0] will be cleared and an asymmetric link will be allocated in lgr->link[SMC_LINKS_PER_LGR_MAX - 1] by smc_llc_alloc_alt_link(). Then when we try to dump SMC-R connections in __smc_diag_dump(), the invalid lgr->lnk[0] will be accessed, resulting in this issue. So fix it by accessing the right link.

Quoted 6 lines
Quoted 3 lines
Fixes f16a7dd5cf27 ("smc: netlink interface for SMC sockets")

What about using Link: http... here?

Thank you, Tony.

According to [1],

"
The Reported-by tag gives credit to people who find bugs and report them and it hopefully inspires them to help us again in the future. The tag is intended for bugs; please do not use it to credit feature requests. The tag should be followed by a Closes: tag pointing to the report, unless the report is not available on the web. The Link: tag can be used instead of Closes: if the patch fixes a part of the issue(s) being reported.
"

So I guess the Closes: tag is fine here.

[1] https://docs.kernel.org/process/submitting-patches.html

Quoted 24 lines
Quoted 1 line
Quoted 20 lines
---
  net/smc/smc_diag.c | 3 +--
  1 file changed, 1 insertion(+), 2 deletions(-)
net/smc/smc_diag.c +1 -2
index a584613aca12..5cc376834c57 100644
@@ -153,8 +153,7 @@ static int __smc_diag_dump(struct sock *sk, struct sk_buff *skb,
  			.lnk[0].link_id = link->link_id,
  		};
 
-		memcpy(linfo.lnk[0].ibname,
-		       smc->conn.lgr->lnk[0].smcibdev->ibdev->name,
+		memcpy(linfo.lnk[0].ibname, link->smcibdev->ibdev->name,
  		       sizeof(link->smcibdev->ibdev->name));
  		smc_gid_be16_convert(linfo.lnk[0].gid, link->gid);
  		smc_gid_be16_convert(linfo.lnk[0].peer_gid, link->peer_gid);
Signature · 1 line
2.43.0
#3 lore raw
In reply to Wen Gu
Quoted 53 lines · Wen Gu

A crash was found when dumping SMC-R connections. It can be reproduced by following steps:

- environment: two RNICs on both sides.
- run SMC-R between two sides, now a SMC_LGR_SYMMETRIC type link group will be created.
- set the first RNIC down on either side and link group will turn to SMC_LGR_ASYMMETRIC_LOCAL then.
- run 'smcss -R' and the crash will be triggered.

  BUG: kernel NULL pointer dereference, address: 0000000000000010
  #PF: supervisor read access in kernel mode
  #PF: error_code(0x0000) - not-present page
  PGD 8000000101fdd067 P4D 8000000101fdd067 PUD 10ce46067 PMD 0
  Oops: 0000 [#1] PREEMPT SMP PTI
  CPU: 3 PID: 1810 Comm: smcss Kdump: loaded Tainted: G W   E      6.7.0-rc6+ #51
  RIP: 0010:__smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
  Call Trace:
   <TASK>
   ? __die+0x24/0x70
   ? page_fault_oops+0x66/0x150
   ? exc_page_fault+0x69/0x140
   ? asm_exc_page_fault+0x26/0x30
   ? __smc_diag_dump.constprop.0+0x36e/0x620 [smc_diag]
   smc_diag_dump_proto+0xd0/0xf0 [smc_diag]
   smc_diag_dump+0x26/0x60 [smc_diag]
   netlink_dump+0x19f/0x320
   __netlink_dump_start+0x1dc/0x300
   smc_diag_handler_dump+0x6a/0x80 [smc_diag]
   ? __pfx_smc_diag_dump+0x10/0x10 [smc_diag]
   sock_diag_rcv_msg+0x121/0x140
   ? __pfx_sock_diag_rcv_msg+0x10/0x10
   netlink_rcv_skb+0x5a/0x110
   sock_diag_rcv+0x28/0x40
   netlink_unicast+0x22a/0x330
   netlink_sendmsg+0x240/0x4a0
   __sock_sendmsg+0xb0/0xc0
   ____sys_sendmsg+0x24e/0x300
   ? copy_msghdr_from_user+0x62/0x80
   ___sys_sendmsg+0x7c/0xd0
   ? __do_fault+0x34/0x1a0
   ? do_read_fault+0x5f/0x100
   ? do_fault+0xb0/0x110
   __sys_sendmsg+0x4d/0x80
   do_syscall_64+0x45/0xf0
   entry_SYSCALL_64_after_hwframe+0x6e/0x76

When the first RNIC is set down, the lgr->lnk[0] will be cleared and an asymmetric link will be allocated in lgr->link[SMC_LINKS_PER_LGR_MAX - 1] by smc_llc_alloc_alt_link(). Then when we try to dump SMC-R connections in __smc_diag_dump(), the invalid lgr->lnk[0] will be accessed, resulting in this issue. So fix it by accessing the right link.

Quoted 4 lines
Fixes f16a7dd5cf27 ("smc: netlink interface for SMC sockets")

That is really good catch and good description! Thank you, Wen Gu, for fixing it!

Reviewed-and-tested-by Wenjia Zhang <[email protected]>
#4 lore raw
In reply to Wen Gu
This patch was applied to netdev/net.git (main) by Jakub Kicinski <[email protected]>:

Hello:

This patch was applied to netdev/net.git (main)
by Jakub Kicinski <[email protected]>:

Quoted 11 lines · On Wed, 27 Dec 2023 15:40:35 +0800 you wrote:

A crash was found when dumping SMC-R connections. It can be reproduced by following steps:

- environment: two RNICs on both sides.
- run SMC-R between two sides, now a SMC_LGR_SYMMETRIC type link group will be created.
- set the first RNIC down on either side and link group will turn to SMC_LGR_ASYMMETRIC_LOCAL then.
- run 'smcss -R' and the crash will be triggered.

[...]

Here is the summary with links: