Skip to contentSkip to conversation

net: dsa: microchip: fix KSZ9477 set_ageing_time function

PATCH In review [email protected] 3 participants 4 messages May 28, 2024 – May 31, 2024

Subsystems (4)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 net: dsa: microchip: fix KSZ9477 set_ageing_time function

From: Tristram Ha <[email protected]>

The aging count is not a simple 11-bit value but comprises a 3-bit multiplier and an 8-bit second count. The code tries to find a set of values with result close to the specifying value.

Note LAN937X has similar operation but provides an option to use millisecond instead of second so there will be a separate fix in the future.

Fixes 2c119d9982b1 ("net: dsa: microchip: add the support for set_ageing_time")
---
 drivers/net/dsa/microchip/ksz9477.c     | 64 +++++++++++++++++++++----
 drivers/net/dsa/microchip/ksz9477_reg.h |  1 -
 2 files changed, 54 insertions(+), 11 deletions(-)
drivers/net/dsa/microchip/ksz9477.c +54 -10
index f8ad7833f5d9..1af11aee3119 100644
@@ -1099,26 +1099,70 @@ void ksz9477_get_caps(struct ksz_device *dev, int port,
 int ksz9477_set_ageing_time(struct ksz_device *dev, unsigned int msecs)
 {
 	u32 secs = msecs / 1000;
+	u8 first, last, mult, i;
+	int min, ret;
+	int diff[8];
 	u8 value;
 	u8 data;
-	int ret;
 
-	value = FIELD_GET(SW_AGE_PERIOD_7_0_M, secs);
+	/* The aging timer comprises a 3-bit multiplier and an 8-bit second
+	 * value.  Either of them cannot be zero.  The maximum timer is then
+	 * 7 * 255 = 1785.
+	 */
+	if (!secs)
+		secs = 1;
 
-	ret = ksz_write8(dev, REG_SW_LUE_CTRL_3, value);
+	ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value);
 	if (ret < 0)
 		return ret;
 
-	data = FIELD_GET(SW_AGE_PERIOD_10_8_M, secs);
+	/* Check whether there is need to update the multiplier. */
+	mult = FIELD_GET(SW_AGE_CNT_M, value);
+	if (mult > 0) {
+		/* Try to use the same multiplier already in the register. */
+		min = secs / mult;
+		if (min <= 0xff && min * mult == secs)
+			return ksz_write8(dev, REG_SW_LUE_CTRL_3, min);
+	}
 
-	ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value);
-	if (ret < 0)
-		return ret;
+	/* Return error if too large. */
+	if (secs > 7 * 0xff)
+		return -EINVAL;
+
+	/* Find out which combination of multiplier * value results in a timer
+	 * value close to the specified timer value.
+	 */
+	first = (secs + 0xfe) / 0xff;
+	for (i = first; i <= 7; i++) {
+		min = secs / i;
+		diff[i] = secs - i * min;
+		if (!diff[i]) {
+			i++;
+			break;
+		}
+	}
+
+	last = i;
+	min = 0xff;
+	for (i = last - 1; i >= first; i--) {
+		if (diff[i] < min) {
+			data = i;
+			min = diff[i];
+		}
+		if (!min)
+			break;
+	}
 
-	value &= ~SW_AGE_CNT_M;
-	value |= FIELD_PREP(SW_AGE_CNT_M, data);
+	if (mult != data) {
+		value &= ~SW_AGE_CNT_M;
+		value |= FIELD_PREP(SW_AGE_CNT_M, data);
+		ret = ksz_write8(dev, REG_SW_LUE_CTRL_0, value);
+		if (ret)
+			return ret;
+	}
 
-	return ksz_write8(dev, REG_SW_LUE_CTRL_0, value);
+	value = secs / data;
+	return ksz_write8(dev, REG_SW_LUE_CTRL_3, value);
 }
 
 void ksz9477_port_queue_split(struct ksz_device *dev, int port)
drivers/net/dsa/microchip/ksz9477_reg.h +0 -1
index f3a205ee483f..0c55a540f20d 100644
@@ -171,7 +171,6 @@
 #define SW_DROP_INVALID_VID		BIT(6)
 #define SW_AGE_CNT_M			GENMASK(5, 3)
 #define SW_AGE_CNT_S			3
-#define SW_AGE_PERIOD_10_8_M		GENMASK(10, 8)
 #define SW_RESV_MCAST_ENABLE		BIT(2)
 #define SW_HASH_OPTION_M		0x03
 #define SW_HASH_OPTION_CRC		1
Signature · 1 line
2.34.1
maintainer
#1 lore raw
Quoted 75 lines · On Tue, 2024-05-28 at 14:36 -0700, [email protected] wrote:

From: Tristram Ha <[email protected]>

The aging count is not a simple 11-bit value but comprises a 3-bit multiplier and an 8-bit second count. The code tries to find a set of values with result close to the specifying value.

Note LAN937X has similar operation but provides an option to use millisecond instead of second so there will be a separate fix in the future.

Fixes 2c119d9982b1 ("net: dsa: microchip: add the support for set_ageing_time")
---
 drivers/net/dsa/microchip/ksz9477.c     | 64 +++++++++++++++++++++----
 drivers/net/dsa/microchip/ksz9477_reg.h |  1 -
 2 files changed, 54 insertions(+), 11 deletions(-)
drivers/net/dsa/microchip/ksz9477.c +35 -7
index f8ad7833f5d9..1af11aee3119 100644
@@ -1099,26 +1099,70 @@ void ksz9477_get_caps(struct ksz_device *dev, int port,
 int ksz9477_set_ageing_time(struct ksz_device *dev, unsigned int msecs)
 {
 	u32 secs = msecs / 1000;
+	u8 first, last, mult, i;
+	int min, ret;
+	int diff[8];
 	u8 value;
 	u8 data;
-	int ret;
 
-	value = FIELD_GET(SW_AGE_PERIOD_7_0_M, secs);
+	/* The aging timer comprises a 3-bit multiplier and an 8-bit second
+	 * value.  Either of them cannot be zero.  The maximum timer is then
+	 * 7 * 255 = 1785.
+	 */
+	if (!secs)
+		secs = 1;
 
-	ret = ksz_write8(dev, REG_SW_LUE_CTRL_3, value);
+	ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value);
 	if (ret < 0)
 		return ret;
 
-	data = FIELD_GET(SW_AGE_PERIOD_10_8_M, secs);
+	/* Check whether there is need to update the multiplier. */
+	mult = FIELD_GET(SW_AGE_CNT_M, value);
+	if (mult > 0) {
+		/* Try to use the same multiplier already in the register. */
+		min = secs / mult;
+		if (min <= 0xff && min * mult == secs)
+			return ksz_write8(dev, REG_SW_LUE_CTRL_3, min);
+	}
 
-	ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value);
-	if (ret < 0)
-		return ret;
+	/* Return error if too large. */
+	if (secs > 7 * 0xff)
+		return -EINVAL;
+
+	/* Find out which combination of multiplier * value results in a timer
+	 * value close to the specified timer value.
+	 */
+	first = (secs + 0xfe) / 0xff;
+	for (i = first; i <= 7; i++) {
+		min = secs / i;
+		diff[i] = secs - i * min;
+		if (!diff[i]) {
+			i++;
+			break;
+		}
+	}
+

drivers/net/dsa/microchip/ksz9477.c void ksz9477_get_caps(struct ksz_device *dev, int port, · line 1154

Quoted 10 lines
drivers/net/dsa/microchip/ksz9477.c +10 -0
+	last = i;
+	min = 0xff;
+	for (i = last - 1; i >= first; i--) {
+		if (diff[i] < min) {
+			data = i;
+			min = diff[i];
+		}
+		if (!min)
+			break;
+	}

Is the additional accuracy worthy the added complexity WRT:

	mult = DIV_ROUND_UP(secs, 0xff);

?

Paolo

#2 lore raw
Quoted 96 lines

Subject: Re: [PATCH net] net: dsa: microchip: fix KSZ9477 set_ageing_time function

EXTERNAL EMAIL: Do not click links or open attachments unless you know the content is safe

Quoted 10 lines · On Tue, 2024-05-28 at 14:36 -0700, [email protected] wrote:

From: Tristram Ha <[email protected]>

The aging count is not a simple 11-bit value but comprises a 3-bit multiplier and an 8-bit second count. The code tries to find a set of values with result close to the specifying value.

Note LAN937X has similar operation but provides an option to use millisecond instead of second so there will be a separate fix in the future.

Review

Quoted 8 lines
Fixes 2c119d9982b1 ("net: dsa: microchip: add the support for set_ageing_time")
---
 drivers/net/dsa/microchip/ksz9477.c     | 64 +++++++++++++++++++++----
 drivers/net/dsa/microchip/ksz9477_reg.h |  1 -
 2 files changed, 54 insertions(+), 11 deletions(-)
(quoted diff) +0 -0

b/drivers/net/dsa/microchip/ksz9477.c

drivers/net/dsa/microchip/ksz9477.c void ksz9477_get_caps(struct ksz_device *dev, int

Quoted 4 lines

index f8ad7833f5d9..1af11aee3119 100644

drivers/net/dsa/microchip/ksz9477.c +0 -0
@@ -1099,26 +1099,70 @@ void ksz9477_get_caps(struct ksz_device *dev, int

port,

Quoted 53 lines
drivers/net/dsa/microchip/ksz9477.c +35 -7
 int ksz9477_set_ageing_time(struct ksz_device *dev, unsigned int msecs)
 {
      u32 secs = msecs / 1000;
+     u8 first, last, mult, i;
+     int min, ret;
+     int diff[8];
      u8 value;
      u8 data;
-     int ret;
 
-     value = FIELD_GET(SW_AGE_PERIOD_7_0_M, secs);
+     /* The aging timer comprises a 3-bit multiplier and an 8-bit second
+      * value.  Either of them cannot be zero.  The maximum timer is then
+      * 7 * 255 = 1785.
+      */
+     if (!secs)
+             secs = 1;
 
-     ret = ksz_write8(dev, REG_SW_LUE_CTRL_3, value);
+     ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value);
      if (ret < 0)
              return ret;
 
-     data = FIELD_GET(SW_AGE_PERIOD_10_8_M, secs);
+     /* Check whether there is need to update the multiplier. */
+     mult = FIELD_GET(SW_AGE_CNT_M, value);
+     if (mult > 0) {
+             /* Try to use the same multiplier already in the register. */
+             min = secs / mult;
+             if (min <= 0xff && min * mult == secs)
+                     return ksz_write8(dev, REG_SW_LUE_CTRL_3, min);
+     }
 
-     ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value);
-     if (ret < 0)
-             return ret;
+     /* Return error if too large. */
+     if (secs > 7 * 0xff)
+             return -EINVAL;
+
+     /* Find out which combination of multiplier * value results in a timer
+      * value close to the specified timer value.
+      */
+     first = (secs + 0xfe) / 0xff;
+     for (i = first; i <= 7; i++) {
+             min = secs / i;
+             diff[i] = secs - i * min;
+             if (!diff[i]) {
+                     i++;
+                     break;
+             }
+     }
+

drivers/net/dsa/microchip/ksz9477.c void ksz9477_get_caps(struct ksz_device *dev, int port, · line 1154

Quoted 10 lines
drivers/net/dsa/microchip/ksz9477.c +10 -0
+     last = i;
+     min = 0xff;
+     for (i = last - 1; i >= first; i--) {
+             if (diff[i] < min) {
+                     data = i;
+                     min = diff[i];
+             }
+             if (!min)
+                     break;
+     }

Is the additional accuracy worthy the added complexity WRT:

Quoted 3 lines
        mult = DIV_ROUND_UP(secs, 0xff);

?

I do not know much accuracy is expected of this function. I do not know whether users can easily specify the amount, but the default is 3 seconds which is the same as the hardware default where the multiplier is 4 and the count is 75. So most of the time the rest of the code will not be executed.

maintainer
#3 lore raw
Quoted 11 lines
Quoted 5 lines

Is the additional accuracy worthy the added complexity WRT:

        mult = DIV_ROUND_UP(secs, 0xff);

?

I do not know much accuracy is expected of this function. I do not know whether users can easily specify the amount, but the default is 3 seconds which is the same as the hardware default where the multiplier is 4 and the count is 75. So most of the time the rest of the code will not be executed.

Are you sure it is 3 seconds?

#define BR_DEFAULT_AGEING_TIME (300 * HZ)

Fast ageing, after a topology change, is i think 15 seconds.

Andrew