net: dsa: motorcomm: Resync SMI slave before register access

PATCH Applied David Yang 2 participants 2 messages Nov 19 – Nov 24

Subsystems (4)
lore
Share & tools
lore

David Yang

author maintainer
#0 lore raw

PATCH v3 1/1 net: dsa: motorcomm: Resync SMI slave before register access

A register access over MDIO is 4 frames: 2 address writes followed by 2 data reads or writes. The SMI slave tracks the phase in a state machine, so an access interrupted between frames, e.g. on an MDIO bus error, leaves the machine in an unknown state, and every following access fails or acts on a stale address until the machine is realigned.

The driver has so far assumed every access succeeds, and relied on manual resetting when the state machine wedged. However, without a dedicated reset line, the reset itself goes through the same SMI interface, causing a chicken-and-egg problem.

Realign the machine once at reset, before the first register access.

---
v3:
- fix transition table
- add dev_err
v2: https://lore.kernel.org/r/[email protected]
- only reset once at setup
v1: https://lore.kernel.org/r/[email protected]

 drivers/net/dsa/motorcomm/chip.c | 102 +++++++++++++++++++++++++++++++
 1 file changed, 102 insertions(+)
drivers/net/dsa/motorcomm/chip.c +102 -0
index 35e70b322608..86e14ec24abc 100644
@@ -98,6 +98,101 @@ struct yt921x_reg_mdio {
 
 /* TODO: SPI/I2C */
 
+/* Realign the SMI state machine as described below.
+ *
+ * An SMI register access is 4 MDIO frames. An interrupted access leaves the
+ * machine in an unknown state, and every following access fails or acts on a
+ * stale address.
+ *
+ * The driver used to assume every access succeeds, and relied on manual
+ * resetting when the state machine wedged. However, without a dedicated reset
+ * line, the reset itself goes through the same SMI interface, causing a
+ * chicken-and-egg problem. Furthermore, the driver verifies the chip id before
+ * firing the reset, so the reset can never be triggered reliably.
+ *
+ * (A/D: address/data, H/L: hi/lo byte, r/w: read/write, ?: the same flag within
+ * a rule)
+ *
+ * State Input Next Comment
+ * ----- ----- ---- -------
+ * AH    aw?   AL?  step #1
+ * AL?   aw?   DH?  step #2
+ * DH?   d?    DL?  step #3
+ * DL?   d?    AH   step #4
+ * A?    dr    A?   `0xdead` sentinel
+ * ALw   awr   AH   FSM reset
+ * D?r   awr   AH   abort, frame discarded
+ * DHw   awr   AH   abort, frame discarded
+ * DHw   dr    DHw  `0xdead` sentinel
+ * DLr   dw    ?    `0xdead` on following drs; next state undetermined
+ * DLw   awr   ALr  abort, frame consumed as next access's addr-hi
+ * DLw   dr    ?    `0xdead` sentinel; next state undetermined
+ *
+ * Any other REGAD/op combination is not characterized and never sent.
+ *
+ * The reset sequence is awr, dr, dr, awr, awr, dr, dr, plus one more dr
+ * as a heuristic sanity check. The sentinel cannot tell AH from AL, which is
+ * why the check is heuristic.
+ *
+ * This is bus-related, but I'm not sure whether it should go to
+ * yt921x_reg_ops - decide it later when we do have a second bus type.
+ */
+static int yt921x_reg_mdio_reset(void *context)
+{
+	struct yt921x_reg_mdio *mdio = context;
+	struct mii_bus *bus = mdio->bus;
+	int addr = mdio->addr;
+	u32 reg_addr;
+	u32 reg_data;
+	int res;
+
+	mutex_lock_nested(&bus->mdio_lock, MDIO_MUTEX_NESTED);
+
+	reg_addr = YT921X_SMI_SWITCHID(mdio->switchid) | YT921X_SMI_ADDR |
+		   YT921X_SMI_READ;
+	reg_data = YT921X_SMI_SWITCHID(mdio->switchid) | YT921X_SMI_DATA |
+		   YT921X_SMI_READ;
+
+	/* awr */
+	res = __mdiobus_write(bus, addr, reg_addr, 0);
+	if (res)
+		goto end;
+	/* dr */
+	res = __mdiobus_read(bus, addr, reg_data);
+	if (res < 0)
+		goto end;
+	/* dr */
+	res = __mdiobus_read(bus, addr, reg_data);
+	if (res < 0)
+		goto end;
+	/* awr */
+	res = __mdiobus_write(bus, addr, reg_addr, 0);
+	if (res)
+		goto end;
+	/* awr */
+	res = __mdiobus_write(bus, addr, reg_addr, 0);
+	if (res)
+		goto end;
+	/* dr */
+	res = __mdiobus_read(bus, addr, reg_data);
+	if (res < 0)
+		goto end;
+	/* dr */
+	res = __mdiobus_read(bus, addr, reg_data);
+	if (res < 0)
+		goto end;
+	/* Heuristic sanity check: expect the `0xdead` sentinel. */
+	res = __mdiobus_read(bus, addr, reg_data);
+	if (res < 0)
+		goto end;
+	res = res != 0xdead ? -EIO : 0;
+
+end:
+	mutex_unlock(&bus->mdio_lock);
+
+	return res;
+}
+
 static int yt921x_reg_mdio_read(void *context, u32 reg, u32 *valp)
 {
 	struct yt921x_reg_mdio *mdio = context;
@@ -2225,6 +2320,13 @@ static int yt921x_chip_reset(struct yt921x_priv *priv)
 	u32 val;
 	int res;
 
+	res = yt921x_reg_mdio_reset(priv->reg_ctx);
+	if (res) {
+		dev_err(dev, "Failed to realign SMI state machine: %i\n",
+			res);
+		return res;
+	}
+
 	res = yt921x_chip_detect(priv);
 	if (res)
 		return res;
Signature · 1 line
2.53.0
#1 lore raw
This patch was applied to netdev/net-next.git (main) by Willem de Bruijn <[email protected]>:

Hello:

This patch was applied to netdev/net-next.git (main) by Willem de Bruijn <[email protected]>:

Quoted 6 lines · On Fri, 20 Nov 2026 02:35:35 +0800 you wrote:

A register access over MDIO is 4 frames: 2 address writes followed by 2 data reads or writes. The SMI slave tracks the phase in a state machine, so an access interrupted between frames, e.g. on an MDIO bus error, leaves the machine in an unknown state, and every following access fails or acts on a stale address until the machine is realigned.

Quoted 6 lines

The driver has so far assumed every access succeeds, and relied on manual resetting when the state machine wedged. However, without a dedicated reset line, the reset itself goes through the same SMI interface, causing a chicken-and-egg problem.

[...]

Here is the summary with links:
- [net-next,v3] net: dsa: motorcomm: Resync SMI slave before register access

    https://git.kernel.org/netdev/net-next/c/bc686737f555

You are awesome, thank you!

Signature · 2 lines
Deet-doot-dot, I am a bot.