Revert "mmc: sdhci: set to INT_DATA_END when there are data"
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
This reverts commit 17ea3c862865c0d704646f67dbf8412f9ff54f59.
In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)
drivers/mmc/sdhci.c +1 -2
@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc *mmc, struct mmc_cmd *cmd, flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
Signature · 1 line
2.25.1
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Best Regards
Andy Wu
Quoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Yuezhang.Mo at sony.com
Sent: Wednesday, March 17, 2021 2:45 PM
To: u-boot at lists.denx.de
Cc: peng.fan at nxp.com; panto at antoniou-consulting.com
Subject: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +1
-3@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc *mmc,struct mmc_cmd *cmd, flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ; --2.25.1
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
In reply to Yuezhang.Mo at sony.comHi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon Chung
Quoted 21 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/mmc/sdhci.c +1
-2@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc *mmc, struct mmc_cmd *cmd, flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit 17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):
U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000)
Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645
*** Warning - No block device, using default environment
And it seems the 17ea3c86 not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.
Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 1 line
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the SDHCI_QUIRK_BROKEN_R1B can be used for this case?
Best Regards
Andy Wu
Quoted 58 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon Chungdrivers/mmc/sdhci.c static int sdhci_send_command(struct mmc *mmc,
Quoted 11 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc *mmc,struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000)
Qualcomm-DragonBoard 410CDRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645
Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right, INT_DATA_END needs to set when there is a data.
If there is no data, it doesn't need to set to it. Logically, there is no problem, isn't?
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?
Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 59 lines
Best Regards
Andy WuQuoted 55 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon Chungdrivers/mmc/sdhci.c static int sdhci_send_command(struct mmc *mmc,
Quoted 10 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc *mmc,struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 3 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is no problem, isn't?
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the INT_DATA_END needs set also, refer sdhci spec explanation for INT_DATA_END bit:
Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)
So, our modification just within if (cmd->resp_type & MMC_RSP_BUSY) judgment.
Best Regards
Andy Wu
Quoted 116 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem, isn't?
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 60 lines
Best Regards
Andy WuQuoted 56 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon Chungdrivers/mmc/sdhci.c static int sdhci_send_command(struct mmc *mmc,
Quoted 10 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc *mmc,struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Quoted 18 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 2 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:
Quoted 7 lines
Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.
Jaehoon,
Do you see any issue if revert the patch?
Thanks,
Peng.
Quoted 123 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 6 lines
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Hi Peng,
Quoted 23 lines · Peng Fan
Quoted 23 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 2 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)
Quoted 6 lines
Quoted 2 lines
So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.Jaehoon,
Do you see any issue if revert the patch?
If you're ok, I will test after reverted the patch on tomorrow, and I will share result. Or I will try to reproduce timeout issue on 410c board.
Best Regards,
Jaehoon Chung
Quoted 127 lines
Thanks,
Peng.Quoted 123 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 6 lines
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
In reply to Peng FanHi Peng,
Quoted 23 lines · Peng Fan
Quoted 23 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 2 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)
Quoted 6 lines
Quoted 2 lines
So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.Jaehoon,
Do you see any issue if revert the patch?
If you're ok, I will test after reverted the patch on tomorrow, and I will share result. Or I will try to reproduce timeout issue on 410c board.
Best Regards,
Jaehoon Chung
Quoted 127 lines
Thanks,
Peng.Quoted 123 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 6 lines
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Hi Jaehoon
Quoted 3 lines
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.
Sorry, but is there any update for this comments?
Best Regards
Andy Wu
Quoted 177 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Tuesday, April 6, 2021 7:13 PM
To: Peng Fan <[email protected]>; jh80.chung at gmail.com; u-boot at lists.denx.de
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Peng,
Quoted 25 lines · Peng Fan
Quoted 25 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 3 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)Quoted 6 lines
Quoted 2 lines
So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.Jaehoon,
Do you see any issue if revert the patch?
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.Best Regards,
Jaehoon ChungQuoted 128 lines
Thanks,
Peng.Quoted 124 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 7 lines
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Dear Andy
Quoted 7 lines · Andy.Wu at sony.com
Hi Jaehoon
Quoted 3 lines
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.Sorry, but is there any update for this comments?
Sorry for replying too late. I had been doing other things.
So if you're ok, i will test on my own boards with your patch until this weekend. (If possible, i will also check 410c board.)
Best Regards,
Jaehoon Chung
Quoted 182 lines
Best Regards
Andy WuQuoted 177 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Tuesday, April 6, 2021 7:13 PM
To: Peng Fan <[email protected]>; jh80.chung at gmail.com; u-boot at lists.denx.de
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Peng,
Quoted 25 lines · Peng Fan
Quoted 25 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 3 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)Quoted 6 lines
Quoted 2 lines
So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.Jaehoon,
Do you see any issue if revert the patch?
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.Best Regards,
Jaehoon ChungQuoted 128 lines
Thanks,
Peng.Quoted 124 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 7 lines
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
PATCH 1/1 Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Dear Andy,
Quoted 9 lines · Jaehoon Chung
Dear Andy
Quoted 6 lines · Andy.Wu at sony.com
Hi Jaehoon
Quoted 3 lines
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.
Quoted 5 lines
Quoted 1 line
Sorry, but is there any update for this comments?
Sorry for replying too late. I had been doing other things.
So if you're ok, i will test on my own boards with your patch until this weekend. (If possible, i will also check 410c board.)
If a problem is occurred again, I will fix again.
Best Regards,
Jaehoon Chung
Quoted 189 lines
Best Regards,
Jaehoon ChungQuoted 182 lines
Best Regards
Andy WuQuoted 177 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Tuesday, April 6, 2021 7:13 PM
To: Peng Fan <[email protected]>; jh80.chung at gmail.com; u-boot at lists.denx.de
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Peng,
Quoted 25 lines · Peng Fan
Quoted 25 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 3 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)Quoted 6 lines
Quoted 2 lines
So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.Jaehoon,
Do you see any issue if revert the patch?
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.Best Regards,
Jaehoon ChungQuoted 128 lines
Thanks,
Peng.Quoted 124 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; jh80.chung at samsung.com; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · Andy.Wu at sony.com
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci at 07824000: 0, sdhci at 07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 7 lines
Did you test on latest u-boot?? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; u-boot at lists.denx.de
Cc: peng.fan at nxp.com; cpgs at samsung.com
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · Yuezhang.Mo at sony.com
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
Hi All
Since patch also reviewed by Jaehoon, how about merge it into mainline?
Best Regards
Andy Wu
Quoted 226 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Thursday, May 20, 2021 6:03 AM
To: Wu, Andy <[email protected]>; [email protected]; [email protected]; [email protected]
Cc: CPGS <[email protected]>
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Dear Andy,
Quoted 9 lines · Jaehoon Chung
Dear Andy
Quoted 6 lines · On 5/11/21 4:39 PM, [email protected] wrote:
Hi Jaehoon
Quoted 3 lines
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.Quoted 5 lines
Quoted 1 line
Sorry, but is there any update for this comments?
Sorry for replying too late. I had been doing other things.
So if you're ok, i will test on my own boards with your patch until this weekend. (If possible, i will also check 410c board.)Reviewed-by Jaehoon Chung <[email protected]>If a problem is occurred again, I will fix again.
Best Regards,
Jaehoon ChungQuoted 191 lines
Best Regards,
Jaehoon ChungQuoted 184 lines
Best Regards
Andy WuQuoted 179 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Tuesday, April 6, 2021 7:13 PM
To: Peng Fan <[email protected]>; [email protected]; [email protected]
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Peng,
Quoted 26 lines · Peng Fan
Quoted 26 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 3 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like
CMD6) type, theINT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)Quoted 6 lines
Quoted 2 lines
So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.Jaehoon,
Do you see any issue if revert the patch?
If you're ok, I will test after reverted the patch on tomorrow, and I will share result.
Or I will try to reproduce timeout issue on 410c board.Best Regards,
Jaehoon ChungQuoted 128 lines
Thanks,
Peng.Quoted 124 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; [email protected]; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; [email protected]
Cc: [email protected]; [email protected]
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · On 3/18/21 10:59 AM, [email protected] wrote:
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000)
Qualcomm-DragonBoard 410CDRAM: 986 MiB MMC: sdhci@07824000: 0, sdhci@07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 7 lines
Did you test on latest u-boot? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; [email protected]
Cc: [email protected]; [email protected]
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · On 3/17/21 3:44 PM, [email protected] wrote:
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;
Hi Peng Fan,
Jaehoon approved this patch.
Do you have more comment for merging?
-----Original Message-----
From: Peng Fan <[email protected]>
Sent: Tuesday, April 6, 2021 6:03 PM
To: Wu, Andy <[email protected]>; [email protected]; [email protected]; Mo, Yuezhang <[email protected]>; [email protected]
Cc: [email protected]
Subject: RE: [PATCH] Revert "mmc: sdhci: set to INT_DATA_END when there are data"
Quoted 19 lines
Subject: RE: [PATCH] Revert "mmc: sdhci: set to
INT_DATA_ENDwhen there are data"Hi Jaehoon
Quoted 2 lines
Did you test on latest u-boot? v2018.01 was too old version.
Yes, we tested on v2020.04, although there is no such issue, but I think it just depends on call sequence timing.
Quoted 3 lines
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data. If there is no data, it doesn't need to set to it. Logically, there is noproblem, isn't?
Quoted 1 line
If there is no data, but current command is RESPONSE-WITH-BUSY (like CMD6) type, the
INT_DATA_ENDneeds set also, refer sdhci spec explanation forINT_DATA_ENDbit:
Quoted 7 lines
Transfer Complete
This bit indicates stop of transaction on three cases:
...
(2) Completion of a command pairing with response-with-busy (R1b, R5b)So, our modification just within if (
cmd->resp_type&MMC_RSP_BUSY) judgment.
Jaehoon,
Do you see any issue if revert the patch?
Thanks,
Peng.
Quoted 124 lines
Best Regards
Andy WuQuoted 4 lines
-----Original Message-----
From: Jaehoon Chung <[email protected]>
Sent: Monday, March 22, 2021 6:03 PM
To: Wu, Andy <[email protected]>; [email protected]; Mo,Yuezhang
Quoted 29 lines
<[email protected]>; [email protected]
Cc: [email protected]; [email protected]
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi Andy,
Quoted 13 lines · On 3/18/21 10:59 AM, [email protected] wrote:
Hi
Quoted 1 line
I don't want to revert this commit. Is there any issue without this?
Without revert commit
17ea3c86, Some board, like Dragonboard 410c will meet transfer data timeout error (we used v2018.01):U-Boot 2018.01 (Nov 26 2020 - 03:31:09 +0000) Qualcomm-DragonBoard 410C
DRAM: 986 MiB MMC: sdhci@07824000: 0, sdhci@07864000: 1 sdhci_transfer_data: Transfer data timeout mmc_init: -70, time 10645Quoted 7 lines
*** Warning - No block device, using default environment
And it seems the
17ea3c86not followed the sdhci specification as transfer complete bit should be wait for the BUSY status de-assert.Kernel side code also wait the transfer complete bit for response-with-busy command.
Quoted 7 lines
Did you test on latest u-boot? v2018.01 was too old version.
And if my understanding is right,
INT_DATA_ENDneeds to set when there is a data.If there is no data, it doesn't need to set to it. Logically, there is no problem,
isn't?
Quoted 61 lines
I will check with QC 410C board for clarifying this problem.
Quoted 7 lines
Quoted 2 lines
Without this patch, some SoCs have timeout error with stop command.
Sorry, we didn't meet this stop command timeout issue, but I guess it maybe another issue, and can be fixed with modification limited to stop command, not for all response-with-busy command.
Does the
SDHCI_QUIRK_BROKEN_R1Bcan be used for this case?Well, it can be used.
Best Regards,
Jaehoon Chung
Quoted 44 lines
Best Regards
Andy WuQuoted 40 lines
-----Original Message-----
From: U-Boot <[email protected]> On Behalf Of Jaehoon Chung
Sent: Thursday, March 18, 2021 6:44 AM
To: Mo, Yuezhang <[email protected]>; [email protected]
Cc: [email protected]; [email protected]
Subject: Re: [PATCH] Revert "mmc: sdhci: set toINT_DATA_ENDwhen there are data"Hi
Quoted 9 lines · On 3/17/21 3:44 PM, [email protected] wrote:
This reverts commit
17ea3c862865c0d704646f67dbf8412f9ff54f59.In eMMC specification, for the response-with-busy(R1b, R5b) command, the DAT0 will driven to LOW as BUSY status, and in sdhci specification, the transfer complete bit should be wait for BUSY status de-assert.
All response-with-busy commands don't contain data, the data judgement is no need.
I don't want to revert this commit. Is there any issue without this? Without this patch, some SoCs have timeout error with stop command.
To prevent it, it needs to increase timeout value at that time. (Timeout value can't fix each boards, waste time to find proper value, and be performance degradation.)
I didn't test without this patch on latest U-boot. But if there is no critical issue, keep it, plz.
Best Regards,
Jaehoon ChungQuoted 5 lines
Signed-off-by Yuezhang.Mo <[email protected]>--- drivers/mmc/sdhci.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
drivers/mmc/sdhci.c static int sdhci_send_command(struct mmc
Quoted 5 lines
drivers/mmc/sdhci.c index renamed from drivers/mmc/sdhci.c +0
-0
d9ab6a0a83..8568f65b18100644drivers/mmc/sdhci.c +0
-0@@ -258,8 +258,7 @@ static int sdhci_send_command(struct mmc*mmc,
Quoted 11 lines
Quoted 11 lines
Quoted 11 lines
struct
mmc_cmd*cmd,Quoted 10 lines
drivers/mmc/sdhci.c +1
-2flags =SDHCI_CMD_RESP_LONG ; else if (cmd->resp_type & MMC_RSP_BUSY) { flags =SDHCI_CMD_RESP_SHORT_BUSY ; -if (data) - mask |=SDHCI_INT_DATA_END ; + mask |=SDHCI_INT_DATA_END ; } else flags =SDHCI_CMD_RESP_SHORT ;